Loading...
Resolution 2007-32 STATE OF ILLINOIS ) )ss COUNTY OF KENDALL ) RESOLUTION NO. 2007- RESOLUTION APPROVING THE FINAL PLAT OF SUBDIVISION FOR RUSH - COPLEY YORKVILLE HEALTHCARE CENTER WHEREAS, by petition dated March 6, 2007, Copley Ventures, Inc. filed with the United City of Yorkville a Final Plat of Subdivision for the Rush - Copley Yorkville Healthcare Center property, as described on Exhibit "A" attached hereto; and WHEREAS, said plan and plat was duly referred by the City Clerk to the City Council of the United City of Yorkville, who, in turn, referred said plan and plat to the Yorkville Plan Commission for study and recommendation, and to the Yorkville Economic Development Committee for recommendation of a final decision; and WHEREAS, said Rush Copley Health Care Center plan has been determined to be in substantial conformance with the United City of Yorkville Zoning Ordinances, being Title 10 of the Yorkville City Code; and WHEREAS, said plat has been determined to be in substantial conformance with the Yorkville Subdivision Control Ordinance, being Title 11 of the Yorkville City Code; and WHEREAS, said plan and plat has been determined to be in substantial conformance with the Planned Unit Development Agreement; and WHEREAS, said plan has been determined to be in substantial conformance with the approved preliminary plan and plat; and WHEREAS, on May 9, 2007, the Yorkville Plan Commission recommended that said plan and plat be approved, subject to the terms and conditions contained herein; and WHEREAS, on May 15, 2007, the Economic Development Committee of the Yorkville City Council reviewed said plan and plat and said recommendations and recommended that said plan and plat be approved. NOW THEREFORE, DE IT RESOLVED by the City Council of the United City of Yorkville as follows: 1. The findings of fact and conclusions contained in the aforesaid preamble recitals of this Resolution are hereby determined and accepted; 2. The said Rush Copley Health Care Center Subdivision plan and plat as described on Exhibit" A" are hereby approved subject to the following conditions: a. Address comments of April 30, 2007 staff report by Travis Miller b. Address comments of March 7, 2007 staff report by EEI c. Address comments of March 27, 2007 staff report by EEI The Yorkville City Clerk is hereby directed to file and keep on record said Rush - Copley Yorkville Healthcare Center Subdivision plan and plat and a certified copy of this Resolution, after its passage and signing by the Mayor, and file said plat after its passage and signing with the applicable County Recorders Office and the applicable County Clerk, at the earliest possible time. PASSED AND APPROVED this a a day of M A V , 2007. ROBYN SUTCLIFF y JOSEPH BESCO V i GARY GOLINSKI y ARDEN JOSEPH PLOCHER WALTER WERDERICH V MARTY MUNNS (\/ ROSE ANN SPEARS y JASON LESLIE I i Approved by me, as Mayor of the M City of Yorkville, Kendall County, Illinois, this o� o� Day of M A 7 , A.D. 2007. MAYOR Passed by the City Council of the United City of Yorkville, Kendall County, Illinois this o� oZ Day of M A 7 , A.D. 2007. ATTEST: CITY CLERK I I i EXHIBIT "A" THAT PART OF THE NORTHEAST % OF SECTION 30, TOWNSHIP 37 NORTH, RANGE 7 EAST OF THE THIRD PRINCIPAL MERIDIAN DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHEAST CORNER OF SAID NORTHEAST 1/4; THENCE SOUTH 01 DEGREES 18 MINUTES 14 SECONDS EAST ALONG THE EAST LINE OF SAID NORTHEAST 1 /4, 479.42 FEET, TO A THE SOUTH RIGHT OF WAY LINE OF U.S. ROUTE NO. 34 FOR A POINT OF BEGINNING; THENCE CONTINUING SOUTH 01 DEGREES, 18 MINUTES 14 SECONDS EAST ALONG SAID EAST LINE, 1431.68 FEET; THENCE SOUTH 88 DEGREES 33 MINUTES 00 SECONDS WEST, 1327.15 FEET, TO THE WEST LINE OF THE EAST ' / OF SAID NORTHEAST % THENCE NORTH 01 DEGREES 13 MINUTES 35 SECONDS WEST ALONG SAID WEST LINE, 1569.79 A POINT ON SAID SOUTH RIGHT OF WAY LINE; THENCE SOUTH 85 DEGREES 29 MINUTES 54 SECONDS EAST ALONG SAID SOUTH RIGHT,_. OF WAY LINE, 1331.85 FEET TO THE POINT OF BEGINNING, ALL IN BRISTOL TOWNSHIP, KENDALL COUNTY, ILLINOIS. I I I , I - 0 c ip O United City of Yorkville Memo J A 800 Game Farm Road l ESL �: 1836 Yorkville, Illinois 60560 Telephone: 630 -553 -8545 0� Fax: 630 -553 -3436 IV Date: April 30, 2007 To: EDC /COW From: Travis Miller, Community Development Director Cc: Lisa Pickering, Deputy Clerk (for distribution) Subject: Rush- Copley Final Plan and Plat Request Backeround The Plan Commission is scheduled to review and make a recommendation May 9, 2007. This recommendation will be reported to you on May 15, 2007. The final plan and plat submitted is consistent with the Preliminary Plan and Plat approved by City Council February 27, 2007. The final plat includes a plat of dedication for Beecher Road right -of -way. The right -of- way includes land owned by Kendall County. The Kendall County Public Building Commission and City Council entered into a intergovernmental agreement August 15, 2006 which allows for this right -of -way dedication to the City and alleviates the County from financial participation in the Beecher/Route 34 intersection improvements. Staff Comments Lot 5 does not include accessible parking spaces. Technically, the ordinance requires 6 spaces for this parking lot. Lot 5 serves as overflow and employee parking and is not near building entrances. The proposed plan includes additional accessible parking spaces in the lots and exceeds the required quantity for accessible spaces overall. Staff recommends approving the parking plan as submitted allowing the `shift' in location of accessible spaces. Staff has requested a re- submittal of the final Landscape Plan to reflect requirements noted for Phase I Site Plan submittal and noting that all Landscape Ordinance requirements will be met at time of submittal. Staff recommends approval of the Final Plan subject to this submission. Staff recommends approval subject to addressing all com ments in the following attached reports: o EEI March 7, 2007 report regarding final engineering review o EEI March 27, 2007 report regarding plat reviews and photometric review 52 Wheeler Road • Sugar Grove, IL 60554 TEL. 630 / 466.9350 FAX 630 / 466.9380 www.eeiweb.com Engineering Enterprises, Inc. March 7, 2007 Mr. Joseph A. Wywrot, P.E. City Engineer United City of Yorkville 800 Game Farm Road Yorkville, IL 60560 Re: Rush - Copley Healthcare Center Phase 1 Final Engineering Plans United City of Yorkville, Kendall County, Illinois Dear Mr. Wywrot: We have reviewed the following on -site and off -site plans submitted as part of Phase I I of the Rush - Copley Healthcare Center: • Site Development Plans for "Rush - Copley Healthcare Center — Phase 1" prepared by Cemcon, Ltd. consisting of twenty -one (21) sheets dated February 9, 2007. • Street Pavement Improvement Plans for Rush - Copley Healthcare Center Driveway B Intersection with U.S. Route 34 consisting of 29 sheets date February 14, 2007. • Street & Sidewalk, Pavement, Street Lighting and Drainage Improvement Plans for Beecher Road consisting of 18 sheets date February 14, 2007. • Final Phase 1 Storm Sewer Sizing Calculations dated February 6, 2007, with the Final Phase 1 Engineering Plans dated February 9, 2007 for the Rush- Copley- Healthcare_Center,_as prepared by Cemcon,_LTD. _ Our review of these plans is to generally determine the plans' compliance with City of Yorkville ordinances and whether the improvements will conform to existing City Consulting Engineers Specializing in Civil Engineering and Land Surveying systems and equipment. This review and our comments do not relieve the designer from his duties to conform to all required codes, regulations, and acceptable standards of engineering practice. Engineering Enterprises, Inc.'s review is not intended as an in -depth quality assurance review. We cannot and do not assume responsibility for design errors or omissions in the plans. Our recommendations and comments are as follows: GENERAL NOTES 1. All references to the IDOT Standard Specifications for Road and Bridge Construction should reference the January 1, 2007 edition. 2. Granular trench backfill references should specify CA -7 as the allowable course aggregate gradation. Trench compaction Method 3 — JettingNVatersoaking is not an allowable methodology and should be deleted from the notes. 3. The detail for "Concrete Curb @ Walk" found on Sheet 5 does not conform to City Standards. The City has no current standard for concrete pavement or for concrete pavement poured monolithically with curb and gutter. The sidewalk thickness is deficient and lacks aggregate base as required by City Standard Specifications. 4. Typical pavement sections found on Sheet 5 should be revised with (DOT's new bituminous mixture designations (Hot Mix Asphalt). OVERALL SANITARY SEWER AND WATERMAIN PLAN 5. Additional hydrants should be provided between H5 and H1, near V2 and V3 and near V1. 6. On Sheet 13, the existing water main should be labeled as 16 -inch instead of 20 -inch. 7. All water main conflicts with sewer should be clearly identified with invert elevations of the upper pipe and top of pipe elevations for the lower pipe at all conflict locations. PARKING LOT GEOMETRIC PLAN 8. The main aisle between Driveway A and the entrance circle should be 27- feet back -to -back. 9. The southernmost aisle in the parking lot shoul also be 27 -feet back - to -back. GAPublic\Yorkville \2005\Y00528 Rush - Copley (Conover- Fisher Property) \docs\Iwywrot0a.doc PLAN AND PROFILE 10. At Valve Vault No.6 on Sheet 37, the plans call for an 8" x 10" pressure connection to be made on an 8 -inch water main. This connection cannot be accomplished. The plans should call for an 8" x 8" pressure connection and an 8" x 12" reducer. The proposed 10 -inch water main should be revised to be proposed 12 -inch water main. The City does not typically accept 10 -inch water main due to maintenance considerations. Graphically, the proposed vault should be shown slightly east of the existing 8 -inch main. 11. Fittings should be avoided where possible. All necessary fittings should be called out on the plans and should be identified as being echanical joint g 1 (MJ) fittings. I 12. Where proposed storm sewers are passing over the proposed water main, the storm sewer should have the proper callout to illustrate that it meets the standards for water main protection. 13. Water main lowerings (dips) should not be accomplished through the use of fittings but should be accomplished by allowable pipe deflection only. The Water Main Lowering Detail on Sheet 46 does not comply with this standard and should be revised. 14. The Revised Engineer's Opinion of Probable Construction Cost (EOPCC) is satisfactory. However, separate EOPCCs for the Beecher Road Improvements and the Route 34 Road Improvements were also submitted but only the Beecher Road Improvements are included with the Rush - Copley costs. Will the Route 34 Improvements be included as well or will it be separate? Also, the total amount changed and a Letter of Credit must be submitted for 110% of the total amount, which is $2,849,550.00. STORM SEWER SIZING 15. Data for pipe MH2 to MH19 should be shown in the plans on sheet 28. 16. The stub pipe sections should be labeled in the plans to correspond to the stub names found in the report. 17. Invert data for the stub (3) that flows into MH15 should be shown in the plans. 18. Pipes 46 to MH19 and stub to 46 are shown in the report, but have no data in the plans. 19. Calculations for the stub that flows into the NW of IN85 should be provided in the report. 20. The diameter (in) of the pipe stub4 to IN11 is shown in the plans as 10, but GAPublic\Yorkville120051Y00528 Rush - Copley (Conover- Fisher Property)ldocsllwywrot08.doe the report shows 12. 21. The diameter (in) of the pipe stub3 to MH15 is shown in the plans as 10, but the report shows 12. 22. MH64 is mislabeled as MH62 on Sheet 33 of the plans. 23. The slope ( %) of pipe MH74 to MH61 is shown as 0.20 in the plans, but the report shows 0.34. 24. The slope ( %) of pipe MH60 to CB59 is shown as 0.20 in the plans, but the report shows 0.46. 25. The length (ft) of pipe MH97 to MH94 is shown as 85 in the plans, but the report shows 100. i 26. The following storm structure invert elevations (ft) should be revised so that the plans and report are in agreement. • MH3 - SW is shown as 625.58 in the plans, but the report shows 625.10 • MH3 - N is shown as 625.10 in the plans, but the report shows 625.72 • MH61 - NW is shown as 626.34, but the report shows 626.25 • CB59 - shown as 626.08 in the plans, but the report shows 626.00 • MH94 - W is not shown in the plans, but the report shows 628.99 • MH56 - the invert data in the plans should indicate the invert directions 27. The following storm structure rim elevations (ft) should be revised so that the plans and report are in agreement. • IN104 - shown as 632.10 in the plans, but the report shows 631.90 • CB105 - shown as 632.10 in the plans, but the report shows 631.90 • MH67 - shown as 632.30 in the plans, but the report shows 628.30 • MH57 - shown as 632.40 in the plans, but the report shows 631.50 • MH56 - shown as 632.40 in the plans, but the report shows 631.50 • IN 100 - shown as 632.40 in the plans, but the report shows 632.30 • CB99 - shown as 632.40 in the plans, but the report shows 632.30 • IN96 - shown as 632.50 in the plans, but the report shows 632.30 • CB95 - shown as 632.50 in the plans, but the report shows 632.30 G: \Public \Yorkvllle\2005 \YO0528 Rush - Copley (Conover- Fisher Property) \docs \lwywrot08.doc STREET PAVEMENT IMPROVEMENT PLANS FOR ROUTE 34 GENERAL 28. The expiration date for the signing professional should be made current. EROSION AND SEDIMENTATION CONTROL PLAN 29. Inlet protection should be shown at all inlets and ditch checks should be provided as needed. PLAN AND PROFILE SHEETS 30. The following storm sewer lengths should be revised: a. Between MH 46 and existing MH: scaled as 44 feet, called out as 49 feet b. Between CB 123 and existing MH: scaled as 51 feet, called out as 37 feet. The slopes of the pipes and the inverts at each end should be checked and revised if necessary. 31. Storm sewers should be shown in the profiles, especially where pipes cross under the roadway. DETAILS 32. The erosion control blanket detail is missing from the details 33. The detail for storm sewer in paved areas lists jetting as the compaction method. Jetting is not an approved method of compaction in the City of Yorkville and should be changed to be mechanical compaction in 6 -inch lifts (Method 2). I STREET & SIDEWALK, PAVEMENT, STREET LIGHTING AND DRAINAGE IMPROVEMENT PLANS FOR BEECHER ROAD GENERAL NOTES 34. United City of Yorkville Park District requires six inches of topsoil for areas being reseeded. Note 1 under Soil Erosion Control and the Typical Details should be revised accordingly. 35. Compaction of all backfill materials should be by mechanical compaction (Method 2) only. Note 19 under Sanitary Sewer, Storm Sewer, Watermain should be revised accordingly. 36. The expiration date for the signing professional should be updated. GAPublic\Yorkville\2005\Y00528 Rush - Copley (Conover- Fisher Property) \docsUwywrot08.doc EROSION AND SEDIMENTATION CONTROL PLAN 37. Inlet protection must be shown at all inlets and ditch checks should be provided as needed. PLAN AND PROFILE SHEETS i 38. The inverts of existing storm structures and/or those structures included in the Rush - Copley Healthcare Center should be called out. i 39. All sidewalks should be 5 feet wide. 40. The sanitary anhole at Sta. 79 +80 should be adjusted or reconstructed as rY J necessary. 41. Elevations should be provided at the beginning and end stations of the improvements. 42. The profile grid on Sheet 9 is missing elevation labels. DETAILS 43. An erosion control blanket detail should be added to the details 44. The detail for storm sewer in paved areas should be changed to indicate mechanical compaction in 6 -inch lifts (Method 2) as the allowable method of trench compaction. CROSS SECTIONS 45. The cross section at Sta. 80 +00 has what appears to be an irrelevant number in the parkway. Please revise as necessary. 46. The centerline slope and the edge of pavement slope for Sta 82 +50 to Sta. 83 +89.79 are the same yet the cross section shows a constant slope across the roadway. ENGINEER'S OPINIONS OF PROBABLE COST 47. The Engineer's Opinion of Probable Construction Cost (EOPCC) should be revised to provide for 12 -inch water main in lieu of 10 -inch water main. An item for water main fittings should also be added to the water main quantities and the pressure connection pay items should be revised in accordance with review comments. There does not appear to be any consideration in the pay items or the EOPCC, in general, to cover the probable costs for dewatering during underground work. We therefore recommend that a 10% Contingency be added to the revised Total Phase I Improvement cost. The required Letter of Credit would be based on the revised total cost. We anticipate that the Route 34 Improvements will have a separate security. GAPublic1Yorkville\2005\Y00528 Rush - Copley (Conover- Fisher Property) \docs \lwywrot08.doc The EOPCC for Route 34 should also contain a 10 % contingency prior to calculating the required Letter of Credit amount for that work. We recommend that the items listed above be addressed and that revised drawings and EOPCC's be submitted for approval. If you have any questions or comments regarding the above or should you require additional information, please feel free to contact our office. Sincerely, ENGINEERING ENTERPRISES, INC. William E. Dunn, P.E. Senior Project Manager PC: Bart Olson, Assistant City Administrator Mr. Travis Miller, Community Development Director Charlie Wunder, Urban Planner Kevin Serafin, Cemcon, Ltd. Jason Xi, Cemcon, Ltd. JWF, EEI i I GAPublic \Yorkville \20051Y00528 Rush - Copley (Conover- Fisher Property) \docs \lwywrot08.doc 52 Wheeler Road • Sugar Grove, IL 60554 TEL: 630 / 466.9350 FAX: 630 / 466.9380 www.eeiweb.com Engineering Ent4grprisew, inc. March 27, 2007 Mr. Joseph A. Wywrot, P.E. City Engineer United City of Yorkville 800 Game Farm Road Yorkville, IL 60560 Re: Rush- Copley Healthcare Center Phase 1 Plat Reviews and Photometric Review United City of Yorkville, Kendall County, Illinois Dear Mr. Wywrot: We have received and reviewed the following items related to the above - referenced project: • Photometric Plans for Rush - Copley Healthcare Center prepared by Anderson Mikos Architects, Ltd. consisting of three (3) sheets dated February 16, 2007. • Various Building Elevations and Site Signage Plans prepared by Anderson Mikos Architects, Ltd. each of which are undated. • Plats of Conveyance West Veterans Parkway (U.S. Route 34) three each, each consisting of one sheet prepared by Cemcon, Ltd. dated March 5, 2007. • Plat of Dedication Beecher Road consisting of one sheet prepared by Cemcon, Ltd. dated March 5, 2007. • Plat of Dedication West Veterans Parkway (U.S. Route 34) consisting of one sheet prepared by Cemcon, Ltd. dated March 5, 2007. • Final P.U.D. for Rush - Copley Healthcare Center consisting of one sheet prepared by Cemcon, Ltd. dated March 2, 2007. • Final Plat of Subdivision Rush - Copley Healthcare Center consisting of two Consulting Engineers Specializing in Civil Engineering and Land Surveying sheets prepared by Cemcon, Ltd. dated March 5, 2007. Our review of these plans is to generally determine the plan's compliance with City of Yorkville ordinances and whether the improvements will conform to existing City systems and equipment. This review and our comments do not relieve the designer from his duties to conform to all required codes, regulations, and acceptable standards of engineering practice. Engineering Enterprises, Inc.'s review is not intended as an in -depth quality assurance review. We cannot and do not assume responsibility for design errors or omissions in the plans. We offer the following comments: PHOTOMETRIC PLAN 1. The average foot - candle intensity should fall within the range of 2.0 to 2.5 foot - candles. The averages shown on the plans do not fall within these ranges. All averages are less than 2.0 foot - candles. 2. The average to minimum average ratio meets the City standard (less or equal to 6:1). 3. The maximum to minimum average ratio meets the City standard (less or equal to 20:1). 4. The maximum veiling luminance to average pavement luminance ratio should be provided and should not exceed a value of 0.3:1. 5. The photometric plan should illustrate lighting intensity values along all property lines and should uniformly show the attainment of zero foot- candles along all property lines. SITE SIGNAGE 6. The retaining wall on which the main entry signage is located should bear a structural engineer's seal either on the plans or as a supplemental document. FINAL PLAT OF SUBDIVISION 7. The bearing and distance from the point of beginning to the point of commencement should be labeled. 8. The legal description does not match the boundary shown on the plat. The legal should be written to follow the measured boundary of the subdivision. 9. An Illinois Department of Transportation certificate should be provided. GAPublic\YorkvillM2005W00528 Rush - Copley (Conover- Fisher Propeity)Idocsllwywrot10.doc 10. The Surveyors Certificate approved by the City should be used. 11. The City Clerk certificate is required. 12. The City Administrator certificate is required. 13. The width of the existing John Street right of way should be shown. 14. The 15 -foot easement line should be shown and labeled along the west line of lot 1 near lot 2. 15.The total area of the subdivision does not equal the 3 lots totaled. If right of way is included in the total it should be indicated in the table. 16. The west lines of lots 1 and 2 are transitional yards and therefore should have 20' building setbacks unless otherwise provided for in the P.U.D. agreement. 17. The minimum side yard setback for lot 2 is 20 feet unless otherwise provided for in the P.U.D. agreement. 18. Access Easement Provisions are should be provided. 19.The 30'X12' Access Easement should also be described as a P.U. &D.E. 20.The width of the P.U. &D.E., on the west side of Beecher road with a centerline bearing of N83 0 56'59' W should be dimensioned. 21.All storm sewer should be located within a P.U. &D.E. 22.The Interim HWL should be placed in a temporary S.W.M.E. Easement language should be developed that indicates that this easement will expire upon the development of Phase II of the Rush- Copley Healthcare Center. 23. Blackberry Woods Subdivision is incorrectly described as Blackberry Creek, LLC and should be corrected. Plat of Dedication for Beecher Road 24.The name of the Plat should be corrected in the title block to read "Beecher Road ". 25.The County Engineers Certificate is not needed, however; the City Clerk and the City Council certificates should be provided since this is going to be dedicated to the City. i GAPubliclYorkville120051YO0528 Rush - Copley (Conover - Fisher Property)\docs \lwywrot1 0.doc 26.An Illinois Department of Transportation certificate should be provided. CONCLUSION In light of the meeting that was held with the City staff, Rush - Copley representatives and the design team on March 21 we anticipate that revised plans will be submitted to the City. We ask that the comments issued above be incorporated into this next set of revisions for review and approval. If you have any questions or comments regarding the above or should you require additional . information, please feel free to contact our office. Sincerely, ENG EERING ENTERPRISES, INC. William E. Dunn, P.E. Senior Project Manager .0I / / ��j / ^i Mark G eller, P.L.S. Project Manager pc: Bart Olson, Assistant City Administrator Mr. Travis Miller, Community Development Director Charlie Wunder, Urban Planner Kevin Serafin, Cemcon, Ltd. Jason Xi, Cemcon, Ltd. JWF, EEI I GAPubliclYorkville120051Y00528 Rush - Copley (Conover- Fisher Property)ldocsllwywrotl0.doc