Public Works Packet 2017 09-19-17
AGENDA
PUBLIC WORKS COMMITTEE MEETING
Tuesday, September 19, 2017
6:00 p.m.
City Hall Conference Room
800 Game Farm Road, Yorkville, IL
Citizen Comments:
Minutes for Correction/Approval: July 18, 2017
New Business:
1. PW 2017-58 Water Department Reports for April, May and June 2017
2. PW 2017-59 Autumn Creek Unit 2C Acceptance
3. PW 2017-60 Kennedy Road Shared Use Path (ITEP) – Authorization Nos. 1 and 2
4. PW 2017-61 Road to Better Roads Program for 2018
5. PW 2017-62 Traffic Control Review
a. Blackberry Woods area
b. Autumn Creek area
6. PW 2017-63 Water Ordinance
7. PW 2017-64 Overview of Downtown Brownfields
8. ADM 2017-70 Building Conditions Survey Results
Old Business:
1. PW 2017-49 Selection of YBSD Liaison
Additional Business:
2017/2018 City Council Goals – Public Works Committee
Goal Priority Staff
“Municipal Building Needs and Planning” 5 Bart Olson & Eric Dhuse
“Vehicle Replacement” 6 Bart Olson & Eric Dhuse
“Water Planning” 8 Eric Dhuse & Brad Sanderson
“Capital Improvement Plan” 11 Bart Olson & Eric Dhuse
“Water Conservation Plan” 15 Eric Dhuse & Brad Sanderson
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
Telephone: 630-553-4350
www.yorkville.il.us
UNITED CITY OF YORKVILLE
WORKSHEET
PUBLIC WORKS COMMITTEE
Tuesday, September 19, 2017
6:00 PM
CITY HALL CONFERENCE ROOM
---------------------------------------------------------------------------------------------------------------------------------------
CITIZEN COMMENTS:
---------------------------------------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------------------------------------------------------
MINUTES FOR CORRECTION/APPROVAL:
---------------------------------------------------------------------------------------------------------------------------------------
1. July 18, 2017
□ Approved __________
□ As presented
□ With corrections
---------------------------------------------------------------------------------------------------------------------------------------
NEW BUSINESS:
---------------------------------------------------------------------------------------------------------------------------------------
1. PW 2017-58 Water Department Reports for April, May and June 2017
□ Moved forward to CC __________ consent agenda? Y N
□ Approved by Committee __________
□ Bring back to Committee __________
□ Informational Item
□ Notes ___________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
---------------------------------------------------------------------------------------------------------------------------------------
2. PW 2017-59 Autumn Creek Unit 2C Acceptance
□ Moved forward to CC __________ consent agenda? Y N
□ Approved by Committee __________
□ Bring back to Committee __________
□ Informational Item
□ Notes ___________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
---------------------------------------------------------------------------------------------------------------------------------------
3. PW 2017-60 Kennedy Road Shared Use Path (ITEP) – Authorization Nos. 1 and 2
□ Moved forward to CC __________ consent agenda? Y N
□ Approved by Committee __________
□ Bring back to Committee __________
□ Informational Item
□ Notes ___________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
---------------------------------------------------------------------------------------------------------------------------------------
4. PW 2017-61 Road to Better Roads Program 2018
□ Moved forward to CC __________ consent agenda? Y N
□ Approved by Committee __________
□ Bring back to Committee __________
□ Informational Item
□ Notes ___________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
---------------------------------------------------------------------------------------------------------------------------------------
5. PW 2017-62 Traffic Control Review
a. Blackberry Woods area
b. Autumn Creek area
□ Moved forward to CC __________ consent agenda? Y N
□ Approved by Committee __________
□ Bring back to Committee __________
□ Informational Item
□ Notes ___________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
---------------------------------------------------------------------------------------------------------------------------------------
6. PW 2017-63 Water Ordinance
□ Moved forward to CC __________ consent agenda? Y N
□ Approved by Committee __________
□ Bring back to Committee __________
□ Informational Item
□ Notes ___________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
---------------------------------------------------------------------------------------------------------------------------------------
7. PW 2017-64 Overview of Downtown Brownfields
□ Moved forward to CC __________ consent agenda? Y N
□ Approved by Committee __________
□ Bring back to Committee __________
□ Informational Item
□ Notes ___________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
---------------------------------------------------------------------------------------------------------------------------------------
8. ADM 2017-70 Building Conditions Survey Results
□ Moved forward to CC __________ consent agenda? Y N
□ Approved by Committee __________
□ Bring back to Committee __________
□ Informational Item
□ Notes ___________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
---------------------------------------------------------------------------------------------------------------------------------------
OLD BUSINESS:
---------------------------------------------------------------------------------------------------------------------------------------
1. PW 2017-49 Selection of YBSD Liaison
□ Moved forward to CC __________ consent agenda? Y N
□ Approved by Committee __________
□ Bring back to Committee __________
□ Informational Item
□ Notes ___________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
---------------------------------------------------------------------------------------------------------------------------------------
ADDITIONAL BUSINESS:
---------------------------------------------------------------------------------------------------------------------------------------
Have a question or comment about this agenda item?
Call us Monday-Friday, 8:00am to 4:30pm at 630-553-4350, email us at agendas@yorkville.il.us, post at www.facebook.com/CityofYorkville,
tweet us at @CityofYorkville, and/or contact any of your elected officials at http://www.yorkville.il.us/320/City-Council
Agenda Item Summary Memo
Title:
Meeting and Date:
Synopsis:
Council Action Previously Taken:
Date of Action: Action Taken:
Item Number:
Type of Vote Required:
Council Action Requested:
Submitted by:
Agenda Item Notes:
Reviewed By:
Legal
Finance
Engineer
City Administrator
Human Resources
Community Development
Police
Public Works
Parks and Recreation
Agenda Item Number
Minutes
Tracking Number
Minutes of the Public Works Committee – July 18, 2017
Public Works Committee – September 19, 2017
Majority
Committee Approval
Minute Taker
Name Department
Page 1 of 2
DRAFT
UNITED CITY OF YORKVILLE
PUBLIC WORKS COMMITTEE
Tuesday, July 18, 2017, 6:00pm
Yorkville City Hall, Conference Room
800 Game Farm Road
IN ATTENDANCE:
Committee Members
Vice-Chairman Ken Koch Alderman Jackie Milschewski
Alderman Seaver Tarulis
Absent: Alderman Joel Frieders
Other City Officials
City Administrator Bart Olson
Interim Assistant City Administrator Erin Willrett
Engineer Brad Sanderson, EEI
Other Guests: None
The meeting was called to order at 6:02pm by Vice-Chairman Ken Koch.
Citizen Comments: None
Previous Meeting Minutes: June 20, 2017
The minutes were approved as presented.
New Business:
1. PW 2017-52 Capital Improvement Project Update
Mr. Sanderson said this was the current quarterly update and the details were in the packet. No further
action.
2. PW 2017-53 Quarterly Bond/LOC Reduction Summary
This item is also a quarterly update. Alderman Koch asked if the Hamman watermain was complete. It
is finished and will be removed from the list.
3. PW 2017-54 NPDES Annual Report
This is a mandatory annual report and will be sent to the IEPA. No further action.
Page 2 of 2
4. PW 2017-55 Windett Ridge Bond Call
Mr. Sanderson said the agreement with Ryland/CalAtlantic requires that all punchlist items need to be
done by the end of August. They have requested additional time to complete the items including
grading of ponds. He said a resident has been calling regarding the washed out trail. He said another
solution will be required since it's a major waterway. The committee was OK with a 2-month
extension and this moves to the consent agenda, however, it will require a vote.
5. PW 2017-56 Water Meter Price Increase
Mr. Olson said prices have not been adjusted for a few years, even though the costs have risen. An
increase is being recommended on meters for new construction. This will not apply to replacement
meters. The committee approved and this moves to the Council agenda next week.
6. PW 2017-57 Downtown Fencing and Sidewalk
Mr. Olson said the City went to RFP for the second time for the west and east alleys. Bids were
received, research was done, but the City was not comfortable with recommending the bidder due to
their distance from the City. It was decided to split the project. It was recommended to reject the bids
at this time. This will be brought back in August.
Old Business: None
Additional Business:
Alderman Milschewski asked about the status of the large holes in the Old Second bank parking lot.
The city was preparing to resurface it, however, the storm structures were found to be in poor condition
and will be repaired first.
Alderman Tarulis showed photos of a deep hole on McHugh in the parkway. Comcast has been
working there and said it would be fixed by this time. The date has passed and staff will follow-up.
Alderman Koch addressed a sidewalk problem on Hawthorne Ct. near Walsh. There are cracks and the
sidewalk has raised up in some spots. Mr. Olson thought it was was an ADA matter and will follow up
with an email. Mr. Sanderson also said Public Works has been working on this and he will follow-up.
There was no further business and the meeting was adjourned at 6:19pm.
Minutes respectfully transcribed by
Marlys Young, Minute Taker
Have a question or comment about this agenda item?
Call us Monday-Friday, 8:00am to 4:30pm at 630-553-4350, email us at agendas@yorkville.il.us, post at www.facebook.com/CityofYorkville,
tweet us at @CityofYorkville, and/or contact any of your elected officials at http://www.yorkville.il.us/320/City-Council
Agenda Item Summary Memo
Title:
Meeting and Date:
Synopsis:
Council Action Previously Taken:
Date of Action: Action Taken:
Item Number:
Type of Vote Required:
Council Action Requested:
Submitted by:
Agenda Item Notes:
Reviewed By:
Legal
Finance
Engineer
City Administrator
Human Resources
Community Development
Police
Public Works
Parks and Recreation
Agenda Item Number
New Business #1
Tracking Number
PW 2017-58
Water Department Reports for April, May and June 2017
Public Works Committee – September 19, 2017
Majority
Approval
Monthly water reports.
Tom Konen Public Works
Name Department
Have a question or comment about this agenda item?
Call us Monday-Friday, 8:00am to 4:30pm at 630-553-4350, email us at agendas@yorkville.il.us, post at www.facebook.com/CityofYorkville,
tweet us at @CityofYorkville, and/or contact any of your elected officials at http://www.yorkville.il.us/gov_officials.php
Agenda Item Summary Memo
Title:
Meeting and Date:
Synopsis:
Council Action Previously Taken:
Date of Action: Action Taken:
Item Number:
Type of Vote Required:
Council Action Requested:
Submitted by:
Agenda Item Notes:
Reviewed By:
Legal
Finance
Engineer
City Administrator
Human Resources
Community Development
Police
Public Works
Agenda Item Number
New Business #2
Tracking Number
PW 2017-59
Autumn Creek – Unit 2C Acceptance
Public Works Committee – September 19, 2017
Consideration of Approval
Subdivision Acceptance Consideration
Brad Sanderson Engineering
Name Department
Pulte has requested that the City accept the public improvements for Autumn Creek - Unit 2C for
ownership and maintenance (see attached).
All work related to the public improvements in Unit 2C, including punch list work has been
completed. We recommend that the public improvements within the above described unit for
water main, sanitary sewer, storm sewer, paving, sidewalk, street lighting and parkway trees as
described in the attached Bill of Sale be accepted for ownership and maintenance by the City.
As required by City Code, the developer will be responsible to provide a performance guarantee
to cover the one year maintenance period. This period starts after the City formally accepts the
improvements.
Along with final acceptance, there is a bond reduction to 10% of the value of the public
improvements (Maintenance Guarantee). Accordingly, the bond reduction and guarantee value
shall be as follows:
Unit 2C Improvements
Original Value $2,400,150.50
Current Value $698,869.88
Required Value (10% of Original) $240,015.05
Net Reduction $458,854.83
Upon City Council approval of the acceptance and the receipt of the executed Bill of Sale and
maintenance guarantee, the existing security may then be released. If you have any questions or
require additional information, please call.
Memorandum
To: Bart Olson, City Administrator
From: Brad Sanderson, EEI
CC: Eric Dhuse, Director of Public Works
Krysti Barksdale-Noble, Community Dev. Dir.
Lisa Pickering, Deputy City Clerk
Date: August 30, 2017
Subject: Autumn Creek - Unit 2C
1
BILL OF SALE
Seller, _______________, in consideration of One and 00/100th Dollar ($1.00), receipt
hereby acknowledged, does hereby sell, assign, transfer and convey to the Buyer, the United City
of Yorkville, an Illinois municipal corporation, at 800 Game Farm Road, Yorkville, Illinois
60560, the following personal property to wit described in Exhibit A attached hereto for the
development know as Autumn Creek – Unit 2C, and generally shown on Exhibit B.
Seller hereby represents and warrants to Buyer that Seller is the absolute owner of said
property, that said property is free and clear of all liens, charges and encumbrances, and that
Seller has full right, power, and authority to sell said property and to make this Bill of Sale.
IN WITNESS WHEREOF, Seller has signed and sealed this Bill of Sale at
___________________________________, this _____ day of _______________, 20__.
Subscribed and Sworn to
before me this _____ day
of _____________, 20__.
_______________________
Notary Public
EXHIBIT A
AUTUMN CREEK ‐ UNIT 2C SUBDIVISION
UNITED CITY OF YORKVILLE
UNIT QUANTITY
Roadway Unit Quantity
SQ YD 60 SLATE DRIVE FOOT
380
CU YD 564 SLATE COURT FOOT
550
FOOT 387 EMERALD LANE FOOT
1,340
FOOT 864 LILAC COURT FOOT
520
FOOT 524 LILAC WAY FOOT
1,200
FOOT 684 RUBY DRIVE FOOT
605
FOOT 362 VIOLET COURT FOOT 560
FOOT 1,173
FOOT 834
FOOT 600
FOOT 263
FOOT 471
FOOT 333
FOOT 385
FOOT 45
EACH 28
EACH 36
EACH 1
EACH 1
EACH 14
EACH 18
EACH 8
EACH 75
FOOT 5,725
EACH 16
EACH 1
EACH 13
EACH 28
EACH 47
CU YD 300
CU YD 1,142
FOOT 2,210
FOOT 1,646
FOOT 190
STORM SEWERS, CLASS A, TY 2, 30"
MANHOLES, TYPE A, 6' DIAMETER
STORM SEWERS, CLASS A, TY 2, 36"
STORM SEWERS, CLASS A, TY 2, 42"
PRECAST REINFORCED CONCRETE FLARED END SECTIONS 15" W/ GRATE
PRECAST REINFORCED CONCRETE FLARED END SECTIONS 42" W/ GRATE
WATER MAIN CONSTRUCTION
1" SINGLE FAMILY WATER SERVICE INCLUDING TRENCH BACKFILL (SH
UTILITIES
STORM SEWER CONSTRUCTION
STORM SEWERS, CLASS A, TY 2, 12"
STORM SEWERS, CLASS A, TY 2, 15"
STORM SEWERS, CLASS A, TY 2, 18"
STONE RIP RAP, CLASS A3
TRENCH BACKFILL
HDPE PERF STORM SEWERS, 10"
HDPE PERF STORM SEWERS, 12"
HDPE PERF STORM SEWERS, 15"
HDPE PERF STORM SEWERS, 21"
HDPE PERF STORM SEWERS, 24"
STORM SEWERS, CLASS A, TY 2, 21"
STORM SEWERS, CLASS A, TY 2, 24"
4" PVC SUMP CONNECTION
CATCH BASINS, TYPE A 4' DIAMETER
INLETS, TYPE A 2' DIA
MANHOLES, TYPE A, 4' DIAMETER
MANHOLES, TYPE A, 5' DIAMETER
FIRE HYDRANTS
8" VALVE AND VALVE BOX
8" PVC (DR‐18) SANITARY SEWER (0'‐15' DEEP)
AUTOMATIC FLUSHING FIRE HYDRANTS
1" SINGLE FAMILY WATER SERVICE INCLUDING TRENCH BACKFILL (LO
TRENCH BACKFILL
SANITARY SEWER CONSTRUCTION
TRENCH BACKFILL
8 ‐ INCH WATER MAIN, DUCTILE IRON
8" PVC (SDR 26) SANITARY SEWER (0'‐15' DEEP)
12" PVC (C900) SANITARY SEWER (0'‐15' DEEP)
EXHIBIT A
AUTUMN CREEK ‐ UNIT 2C SUBDIVISION
UNITED CITY OF YORKVILLE
EACH 19
EACH 41
EACH 34
EACH 18
SQ FT 39,976
SQ YD 1,922
6" SANITARY SEWER SERVICE INCLUDING TRENCH BACKFILL (LONG)
6" SANITARY SEWER SERVICE INCLUDING TRENCH BACKFILL (SHORT)
MISCELLANOUS UNDERGROUND CONSTRUCTION
STREETLIGHTS
ROADWAY CONSTRUCTION
BIKE PATH 8' WIDTH (2" MA SURFACE COURSE W/ 8" AGGREGATE B
PCC SIDEWALK 5" W/ 2" AGG SUBBASE (6" THRU DRIVE W/ AGG BAS
4' SANITARY MANHOLES (0'‐15' DEEP)
KennedyLillianC a n n o n b a l l LilacBristol RidgeSlateEm eraldRubySageTitusLakeview
AndreaO v e r lo o kVioletSunset CrimsonCoralBazanRoyal OaksChristyCobaltMaddenA u tu m n C re e kEmerald
Engineering Enterprises, Inc.52 Wheeler RoadSugar Grove, Illinois 60554(630) 466-6700 / www.eeiweb.conUNIT 2CLOCATION MAPDATE:AUGUST 2017United City of Yorkville800 Game Farm RoadYorkville, IL 60560(630) 553-4350http://www.yorkville.il.usAUTUMN CREEK CONSULTING ENGINEERSNO. DATE REVISIONSPROJECT NO.:YO1327PATH:H:/GIS/PUBLIC/YORKVILLE/2013/YO1327- AUTUMN CREEK - 2C .MXDFILE:fffääNORTHUnit Boundary800 0 800400 FeetUnit 2C
Have a question or comment about this agenda item?
Call us Monday-Friday, 8:00am to 4:30pm at 630-553-4350, email us at agendas@yorkville.il.us, post at www.facebook.com/CityofYorkville,
tweet us at @CityofYorkville, and/or contact any of your elected officials at http://www.yorkville.il.us/gov_officials.php
Agenda Item Summary Memo
Title:
Meeting and Date:
Synopsis:
Council Action Previously Taken:
Date of Action: Action Taken:
Item Number:
Type of Vote Required:
Council Action Requested:
Submitted by:
Agenda Item Notes:
Reviewed By:
Legal
Finance
Engineer
City Administrator
Human Resources
Community Development
Police
Public Works
Parks and Recreation
Agenda Item Number
New Business #3
Tracking Number
PW 2017-60
Kennedy Road Shared Use Path (ITEP)
Public Works Committee – September 19, 2017
Consideration of Approval
Consideration of Authorization Nos. 1 & 2
Brad Sanderson Engineering
Name Department
The purpose of this memo is to present Authorizations 1 & 2 for the above referenced project.
An authorization, as defined by IDOT, is the written approval of a contract change and the
written directive to the contractor to perform said work. By this definition, it alters the contract
work from that awarded under the competitive bidding process. An Authorization of Contract
Changes signed by the Regional Engineer signifies completed review of and support for the
change proposed.
Background:
The State of Illinois and “D” Construction, Inc. entered into an agreement for a contract value of
$753,941.81 for the above referenced project. Construction began on July 17, 2017 and the
project is approximately 65% complete.
The construction costs are being funded by ITEP funds (federal) and local funds. The maximum
federal participation amount is $883,336.00, inclusive of all change orders (authorizations)
associated with this contract.
Questions Presented:
Should the City approve Authorizations Nos. 1 ($7,420.00) and 2 ($605.88) in the amount of
$8,025.88?
Discussion:
Authorization No. 1 covers additional labor, equipment and materials required to place
thermoplastic pavement marking symbols, including:
Railroad warning symbols in advance of the pedestrian crossing at the Burlington
Northern Santa Fe Railroad at-grade crossing.
Memorandum
To: Bart Olson, City Administrator
From: Brad Sanderson, EEI
CC: Eric Dhuse, Director of Public Works
Krysti Barksdale-Noble, Community Dev. Dir.
Lisa Pickering, Deputy City Clerk
Date: September 5, 2017
Subject: Kennedy Road Shared Use Path (ITEP)– Authorizations 1 & 2
Authorization No. 2 covers additional labor, equipment and materials required to remove and
replace unsuitable soils encountered during excavation including:
Excavation of unsuitable soils.
Replacement of excavated material with 6 inches of CA-06 aggregate.
The net change to date for authorizations is $8,025.88 which is a 1.06% increase to the original
contract value bringing a revised contract value to date of $761,967.69. The City will be
responsible for 20% of the total or $1,605.18.
We have attached IDOT form BC-22 for Authorization Nos. 1 & 2 for your information. All
authorizations have a pre-approval from the IDOT District 3 Local Agency Bureau of
Construction Engineer.
We are recommending approval of the Authorizations.
Action Required:
Consideration of approval from the City Council for Authorizations 1 & 2.
Have a question or comment about this agenda item?
Call us Monday-Friday, 8:00am to 4:30pm at 630-553-4350, email us at agendas@yorkville.il.us, post at www.facebook.com/CityofYorkville,
tweet us at @CityofYorkville, and/or contact any of your elected officials at http://www.yorkville.il.us/gov_officials.php
Agenda Item Summary Memo
Title:
Meeting and Date:
Synopsis:
Council Action Previously Taken:
Date of Action: Action Taken:
Item Number:
Type of Vote Required:
Council Action Requested:
Submitted by:
Agenda Item Notes:
Reviewed By:
Legal
Finance
Engineer
City Administrator
Human Resources
Community Development
Police
Public Works
Agenda Item Number
New Business #4
Tracking Number
PW 2017-61
2018 RTBR Program
Public Works Committee – September 19, 2017
Consideration of Approval
Review Recommended Plan
Brad Sanderson Engineering
Name Department
The recommended 2018 (FY19) RTBR program based on a $650,000 budget is noted below.
Street Operation Preliminary Cost
Spring Street (Bridge to McHugh) Mill/Overlay $190,000
Teri Lane (Spring to North End) Mill/Overlay $90,000
Walsh Drive (Barberry to North End) Mill/Overlay $110,000
Pavillion Road (Rt 71 to City Limit) Overlay $55,000
Crack Sealing Crack Sealing $15,000
Pavillion Road Streambank Stabilization (Construction) Maintenance $100,000
2018 (FY19) RTBR Construction Engineering/Testing N/A $50,000
2019 (FY 20) RTBR Design Engineering N/A $40,000
Total $650,000
For reference, the last approved five-year plan is attached.
Spring Street was planned for 2018 (FY19) construction.
Teri Lane has deteriorated faster than the program had projected and it is need of repair. It is also
adjacent to Spring Street, which will be efficient for a contractor to complete.
Walsh Drive has deteriorated faster than the program had projected and a portion of the street was
resurfaced last year. The proposed project completes the paving of that section of street.
The northern section of Pavillion Road was resurfaced in 2017 (FY18). The southern section near Rt 71
was not completed. This section has deteriorated and is in need of patching and an overlay.
Memorandum
To: Bart Olson, City Administrator
From: Brad Sanderson, EEI
CC: Eric Dhuse, Director of Public Works
Krysti Barksdale-Noble, Community Dev. Dir.
Lisa Pickering, Deputy City Clerk
Date: September 14, 2017
Subject: 2018 (FY19)Roads to Better Roads Program
Also, it is recommended that the Road Study be updated every five to seven years. The field data
gathered from the last study was completed in 2012. We are recommending that an updated
study per performed and budgeted at $65,000. The new study will include the gathering of field
data along with preparing updated exhibits and a five-year plan.
At this time we are seeking approval to move forward with the 2018 (FY19) RTBR program. If
you have any questions or require additional information, please let us know.
()-()-
()-()-()-()-()-()-()-()-()-()-()-()-()-()-()-()-()-)()-()-()-()-()-()-()-()-()-()-()-
()-
()-()-()-()-()-
()-()-()-()-()-()-()-()-()-()-()-()-()-()-()-()-(
)-)()-()-()-()-()-()-()-()-()-()-()-
()-
()-()-()-
Madison StMadison CtBridgeSpring
Main
MillVan Emmon
Park
Somonauk
Center
Benjamin
OrangeState TeriDeerapl e McHughElm
KingOmahaLibertyB a r b e r r y HeustisWashington WackerJackson
BruellFreemontBeaverMorganChurchAdrian Ka
BristolColonial
Madison Coltonhite Oak
Blaine
F o x b o r o
Wolf
ked CreekElizabeth
BadgerGardenGame FarmAdamsGawneWi n d s o r
Ridge
Illini
Wooden BridgeOlsenWest
Walter
Martin
Wood SaWoodworthDolph WorsleyHydraulic
Woodland AuburnSandersOakwoodTowerDydyna
R
Behrens
Marie
SpruceBellOx
f
o
r
d JohnsonBatorTomasikVictoria
Beecher
Appletree
Rodak
Buck t hor n JeffersonB u h r ma s t e r
Spicebush
Wooddale
StateRidge MainDolph MainS
c
h
o
ol
h
o
u
s
eMorganMainHydraulic
Legend
2018 RTBR PROGRAM
()-()-()-
(
)-()-()-()-TimberCreek ArcadiaPavillion
LegionHighview
Engineering Enterprises, Inc.
52 Wheeler Road
Sugar Grove, Illinois 60554
(630) 466-6700
PROPOSED 2018 RTBR PROGRAM
LOCATION MAP
www.eeiweb.com
DATE:
PROJECT NO.:
FILE:
PATH:
BY:
September 2017
YO1739
YO1739_2018 Road Program .MXD
H:\GIS\PUBLIC\YORKVILLE\2017\
MJT
United City of Yorkville
800 Game Farm Road
Yorkville, IL 60560
630-553-4350 ³IL Route 71
PROPOSED 5 YEAR RTBR PROGRAMUnited City of YorkvilleOctober 2016STREET FROM TO STRATEGYDEFLECTION CONDITIONDYNAMIC CONDITIONSURFACE CONDITIONCURRENT RANKCOSTMADISON COURTW. MADISON STREETWEST ENDMILL & OVERLAY100686573$7,700MADISON STREETWEST ENDMORGAN STREETMILL & OVERLAY100705264$24,500MAIN STREETW. VAN EMMON STEETW. HYDRAULIC AVENUEMILL & OVERLAY100756275$12,400MAIN STREETS. BRIDGE STREETW. RIDGE STREETMILL & OVERLAY100836076$123,800WASHINGTON STREETW. MORGAN STREETS. MAIN STREETMILL & OVERLAY100675764$40,100PAVILLION ROADFOX ROADCITY LIMITMILL & OVERLAY97676567$139,000E. RIDGE STREETEAST ENDMILL STREETMILL & OVERLAY100834771$32,300TOWER LANESOMONAUK STREETPUBLIC WORKSMILL & OVERLAY100416253$17,900CITY HALL PARKING LOTSMILL & OVERLAYN/AN/AN/AN/A$62,000PUBLIC WORKS PARKING LOTMILL & OVERLAYN/AN/AN/AN/A$121,000$658,700TIF ELIGIBLE PROJECTSRIVERFRONT PARKING LOTMILL & OVERLAYN/AN/AN/AN/A$29,000EAST ALLEY PARKING LOTOVERLAYN/AN/AN/AN/A$42,000ALTERNATIVE STREETS VERSUS PARKING LOT PROJECTSELIZABETH STREET WEST END S. MAIN STREET MILL & OVERLAY 100 69 72 78 $52,500RIDGE STREET JEFFERSON STREET S. MAIN STREET MILL & OVERLAY 100 82 55 76 $15,100STATE STREET W. HYDRAULIC STEET W. RIDGE STREET MILL & OVERLAY 100 80 54 73 $44,000WHEATON AVENUE N. BRIDGE STREET SHADOW WOOD DRIVE MILL & OVERLAY 86 82 71 75 $124,600$236,200TOTAL:2017 (FY18) STREET REHABILITATION LISTTOTAL:BEECHER CENTER, LIBRARY, PARKS AND RECREATION, BRIDGE PARK PARKING LOT SEAL & STRIPE$78,000N/AN/AN/AN/A
PROPOSED 5 YEAR RTBR PROGRAMUnited City of YorkvilleOctober 2016STREET FROM TO STRATEGYDEFLECTION CONDITIONDYNAMIC CONDITIONSURFACE CONDITIONCURRENT RANKCOSTELM STREET MCHUGH ROAD FREEMONT STREET MILL & OVERLAY 100 70 61 73 $59,400JACKSON STREET FREEMONT STREET MARTIN AVENUE MILL & OVERLAY 100 69 57 69 $62,700PARK STREET MCHUGH ROAD BRIDGE STREET MILL & OVERLAY 100 66 64 71 $125,000SANDERS COURT E. MAIN STREET NORTH END MILL & OVERLAY 100 46 69 62 $44,100SPRING STREET W. SPRING STREET QUINSEY ROAD MILL & OVERLAY 87 74 64 67 $268,200WHEATON AVENUE N. BRIDGE STREET SHADOW WOOD DRIVE MILL & OVERLAY 86 82 71 75 $124,600$684,0002018 (FY19) STREET REHABILITATION LISTTOTAL:
PROPOSED 5 YEAR RTBR PROGRAMUnited City of YorkvilleOctober 2016STREET FROM TO STRATEGYDEFLECTION CONDITIONDYNAMIC CONDITIONSURFACE CONDITIONCURRENT RANKCOSTALAN DALE LANE RED TAIL COURT ALICE AVE MILL & OVERLAY 81 66 80 64 $49,400ALICE AVENUE CANNONBALL TRAIL FAXON ROAD MILL & OVERLAY 85 78 77 76 $148,400ELIZABETH STREET WEST END S. MAIN STREET MILL & OVERLAY 100 69 72 78 $52,500FOX STREET EAST END MILL STREET MILL & OVERLAY 87 71 82 78 $35,200LIBERTY STREET SOUTH END E. PARK STREET MILL & OVERLAY 87 74 83 76 $79,400MCHUGH FARMSTEAD DRIVE CITY LIMIT MILL & OVERLAY 100 78 71 76 $44,300OLSEN STREET MILL STREET EAST END MILL & OVERLAY 74 61 75 64 $40,100ORANGE STREET MILL STREET EAST END MILL & OVERLAY 86 72 71 75 $36,100RIDGE STREET JEFFERSON STREET S. MAIN STREET MILL & OVERLAY 100 82 55 76 $15,100STATE STREET W. HYDRAULIC STEET W. RIDGE STREET MILL & OVERLAY 100 80 54 73 $44,100$544,6002019 (FY20) STREET REHABILITATION LISTTOTAL:
PROPOSED 5 YEAR RTBR PROGRAMUnited City of YorkvilleOctober 2016STREET FROM TO STRATEGYDEFLECTION CONDITIONDYNAMIC CONDITIONSURFACE CONDITIONCURRENT RANKCOSTAPPLETREE COURT N. BRIDGE STREET WEST END MILL & OVERLAY 73 57 80 64 $26,200BARBERRY CIRCLE - WEST WALSH DRIVE WALSH DRIVE MILL & OVERLAY 79 65 77 67 $118,600BARBERRY CIRCLE - EAST WALSH DRIVE WALSH DRIVE MILL & OVERLAY 85 69 77 76 $99,300BEAVER STREET S. BRIDGE STREET DEER STREET MILL & OVERLAY 85 79 72 67 $81,800BURNING BUSH DRIVE WALSH DRIVE WEST END MILL & OVERLAY 77 63 77 69 $44,000COLONIAL PARKWAY S. BRIDGE STREET SCHOOLHOUSE ROAD MILL & OVERLAY 85 73 74 75 $90,400DEER STREET WOLF STREET SCHOOLHOUSE ROAD MILL & OVERLAY 84 71 79 69 $100,300$560,6002020 (FY21) STREET REHABILITATION LISTTOTAL:
PROPOSED 5 YEAR RTBR PROGRAMUnited City of YorkvilleOctober 2016STREET FROM TO STRATEGYDEFLECTION CONDITIONDYNAMIC CONDITIONSURFACE CONDITIONCURRENT RANKCOSTCOTTONWOOD TRAIL JOHN STREET JOHN STREET MILL & OVERLAY 87 70 80 73 $126,700COTTONWOOD COURT COTTONWOOD TRAIL WEST END MILL & OVERLAY 100 80 75 84 $9,100DEIHL FARM ROAD JOHN STREET W. VETERANS PRKWY MILL & OVERLAY 84 67 71 64 $66,900RIVER BIRCH DR EAST END WEST END MILL & OVERLAY 89 71 80 79 $9,100RIVER BIRCH LN RIVER BIRCH DR WHITE OAK WAY MILL & OVERLAY 99 89 73 85 $19,700SPRUCE COURT WEST END WHITE OAK WAY MILL & OVERLAY 100 67 65 71 $26,500SYCAMORE ROAD W. VETERANS PRKWY CITY LIMIT MILL & OVERLAY 87 70 76 71 $88,800WHITE OAK WAY W. FOX STREET NOWAY CIRCLE MILL & OVERLAY 90 75 74 75 $263,200$610,0002021 (FY22) STREET REHABILITATION LISTTOTAL:
Have a question or comment about this agenda item?
Call us Monday-Friday, 8:00am to 4:30pm at 630-553-4350, email us at agendas@yorkville.il.us, post at www.facebook.com/CityofYorkville,
tweet us at @CityofYorkville, and/or contact any of your elected officials at http://www.yorkville.il.us/320/City-Council
Agenda Item Summary Memo
Title:
Meeting and Date:
Synopsis:
Council Action Previously Taken:
Date of Action: Action Taken:
Item Number:
Type of Vote Required:
Council Action Requested:
Submitted by:
Agenda Item Notes:
Reviewed By:
Legal
Finance
Engineer
City Administrator
Human Resources
Community Development
Police
Public Works
Parks and Recreation
Agenda Item Number
New Business #5
Tracking Number
PW 2017-62
Intersections – Sign Control
Public Works Committee – September 19, 2017
Brad Sanderson Engineering
Name Department
As requested, we investigated the possible installation of stop signs at the intersection of Cannonball Trail
and N Carly Circle/Carly Drive. Our findings were as follows:
Currently there is no signage control at the intersection.
The intersection does not appear to have any sight distance constraints.
The governing entity on traffic control signage is the Manual on Uniform Traffic Control Devices
(MUTCD). The manual states as follows in regards to stop sign installation:
Guidance:
Engineering judgment should be used to establish intersection control. The following factors
should be considered:
A. Vehicular, bicycle, and pedestrian traffic volumes on all approaches;
B. Number and angle of approaches;
C. Approach speeds;
D. Sight distance available on each approach; and
E. Reported crash experience.
YIELD or STOP signs should be used at an intersection if one or more of the following conditions
exist:
A. An intersection of a less important road with a main road where application of the normal
right-of-way rule would not be expected to provide reasonable compliance with the law;
B. A street entering a designated through highway or street; and/or
C. An unsignalized intersection in a signalized area.
In addition, the use of YIELD or STOP signs should be considered at the intersection of two
minor streets or local roads where the intersection has more than three approaches and where
one or more of the following conditions exist:
A. The combined vehicular, bicycle, and pedestrian volume entering the intersection from all
approaches averages more than 2,000 units per day;
B. The ability to see conflicting traffic on an approach is not sufficient to allow a road user to
stop or yield in compliance with the normal right-of-way rule if such stopping or yielding is
necessary; and/or
C. Crash records indicate that five or more crashes that involve the failure to yield the right-of-
way at the intersection under the normal right-of-way rule have been reported within a 3-year
period, or that three or more such crashes have been reported within a 2-year period.
Yield or Stop signs should not be used for speed control.
Since the traffic volume would appear to be below 2,000 units per day, there are no sight distance
constraints and there does not appear to be an accident history, this intersection does not appear to be a
Memorandum
To: Bart Olson, City Administrator
From: Brad Sanderson, EEI
CC: Eric Dhuse, Director of Public Works
Krysti Barksdale-Noble, Community Dev. Dir.
Lisa Pickering, Deputy City Clerk
Date: September 6, 2017
Subject: Cannonball Trail and N Carly Circle/Carly Drive Stop Sign
good candidate for a stop sign based on the above criteria. Generally, at an unsigned intersection, the
application of the normal right-of-way rules would apply.
Figure D taken from the Illinois Drivers Manual shows that the minor roadway should yield to traffic on
the major roadway at uncontrolled intersections.
It is our understanding that there may be a concern regarding speed on Cannonball Trail. This may be
more properly addressed with enforcement or if necessary traffic calming devices.
As requested, we investigated the possible installation of stop signs at the intersection of Cannonball Trail
and Cody Court/Patrick Court. Our findings were as follows:
Currently there is no signage control at the intersection.
The intersection does not appear to have any sight distance constraints.
The governing entity on traffic control signage is the Manual on Uniform Traffic Control Devices
(MUTCD). The manual states as follows in regards to stop sign installation:
Guidance:
Engineering judgment should be used to establish intersection control. The following factors
should be considered:
A. Vehicular, bicycle, and pedestrian traffic volumes on all approaches;
B. Number and angle of approaches;
C. Approach speeds;
D. Sight distance available on each approach; and
E. Reported crash experience.
YIELD or STOP signs should be used at an intersection if one or more of the following conditions
exist:
A. An intersection of a less important road with a main road where application of the normal
right-of-way rule would not be expected to provide reasonable compliance with the law;
B. A street entering a designated through highway or street; and/or
C. An unsignalized intersection in a signalized area.
In addition, the use of YIELD or STOP signs should be considered at the intersection of two
minor streets or local roads where the intersection has more than three approaches and where
one or more of the following conditions exist:
A. The combined vehicular, bicycle, and pedestrian volume entering the intersection from all
approaches averages more than 2,000 units per day;
B. The ability to see conflicting traffic on an approach is not sufficient to allow a road user to
stop or yield in compliance with the normal right-of-way rule if such stopping or yielding is
necessary; and/or
C. Crash records indicate that five or more crashes that involve the failure to yield the right-of-
way at the intersection under the normal right-of-way rule have been reported within a 3-year
period, or that three or more such crashes have been reported within a 2-year period.
Yield or Stop signs should not be used for speed control.
Since the traffic volume would appear to be below 2,000 units per day, there are no sight distance
constraints and there does not appear to be an accident history, this intersection does not appear to be a
Memorandum
To: Bart Olson, City Administrator
From: Brad Sanderson, EEI
CC: Eric Dhuse, Director of Public Works
Krysti Barksdale-Noble, Community Dev. Dir.
Lisa Pickering, Deputy City Clerk
Date: September 6, 2017
Subject: Cannonball Trail and Cody Court/Patrick Court Stop Sign
good candidate for a stop sign based on the above criteria. Generally, at an unsigned intersection, the
application of the normal right-of-way rules would apply.
Figure D taken from the Illinois Drivers Manual shows that the minor roadway should yield to traffic on
the major roadway at uncontrolled intersections.
It is our understanding that there may be a concern regarding speed on Cannonball Trail. This may be
more properly addressed with enforcement or if necessary traffic calming devices.
As requested, we investigated the possible installation of stop signs at the intersection of Cannonball Trail
and Independence Boulevard. Our findings were as follows:
Currently there are yield signs at the approaches on Independence Boulevard.
The intersection does appear to have sight distance constraints on the southeast corner of the
intersection.
The governing entity on traffic control signage is the Manual on Uniform Traffic Control Devices
(MUTCD). The manual states as follows in regards to stop sign installation:
Guidance:
Engineering judgment should be used to establish intersection control. The following factors
should be considered:
A. Vehicular, bicycle, and pedestrian traffic volumes on all approaches;
B. Number and angle of approaches;
C. Approach speeds;
D. Sight distance available on each approach; and
E. Reported crash experience.
YIELD or STOP signs should be used at an intersection if one or more of the following conditions
exist:
A. An intersection of a less important road with a main road where application of the normal
right-of-way rule would not be expected to provide reasonable compliance with the law;
B. A street entering a designated through highway or street; and/or
C. An unsignalized intersection in a signalized area.
In addition, the use of YIELD or STOP signs should be considered at the intersection of two
minor streets or local roads where the intersection has more than three approaches and where
one or more of the following conditions exist:
A. The combined vehicular, bicycle, and pedestrian volume entering the intersection from all
approaches averages more than 2,000 units per day;
B. The ability to see conflicting traffic on an approach is not sufficient to allow a road user to
stop or yield in compliance with the normal right-of-way rule if such stopping or yielding is
necessary; and/or
C. Crash records indicate that five or more crashes that involve the failure to yield the right-of-
way at the intersection under the normal right-of-way rule have been reported within a 3-year
period, or that three or more such crashes have been reported within a 2-year period.
Yield or Stop signs should not be used for speed control.
Memorandum
To: Bart Olson, City Administrator
From: Brad Sanderson, EEI
CC: Eric Dhuse, Director of Public Works
Krysti Barksdale-Noble, Community Dev. Dir.
Lisa Pickering, Deputy City Clerk
Date: September 6, 2017
Subject: Cannonball Trail and Independence Boulevard Stop Sign
The traffic volume appears to be below 2,000 units per day and there does not appear to be an accident
history at this location. However, since there are sight distance constraints on the southeast corner of the
intersection, the intersection is a good candidate for a two-way intersection control.
The MUTCD states as follows in regards to multi-way stop sign installation:
Guidance:
The decision to install multi-way stop control should be based on an engineering study.
The following criteria should be considered in the engineering study for a multi-way STOP sign
installation:
A. Where traffic control signals are justified, the multi-way stop is an interim measure that can be
installed quickly to control traffic while arrangements are being made for the installation of the
traffic control signal.
B. Five or more reported crashes in a 12-month period that are susceptible to correction by a
multi-way stop installation. Such crashes include right-turn and left-turn collisions as well as
right-angle collisions.
C. Minimum volumes:
1. The vehicular volume entering the intersection from the major street approaches (total
of both approaches) averages at least 300 vehicles per hour for any 8 hours of an
average day; and
2. The combined vehicular, pedestrian, and bicycle volume entering the intersection from
the minor street approaches (total of both approaches) averages at least 200 units per
hour for the same 8 hours, with an average delay to minor-street vehicular traffic of at
least 30 seconds per vehicle during the highest hour; but
3. If the 85th-percentile approach speed of the major-street traffic exceeds 40 mph, the
minimum vehicular volume warrants are 70 percent of the values provided in Items 1 and
2.
D. Where no single criterion is satisfied, but where Criteria B, C.1, and C.2 are all satisfied to 80
percent of the minimum values. Criterion C.3 is excluded from this condition.
Option:
Other criteria that may be considered in an engineering study include:
A. The need to control left-turn conflicts;
B. The need to control vehicle/pedestrian conflicts near locations that generate high pedestrian
volumes;
C. Locations where a road user, after stopping, cannot see conflicting traffic and is not able to
negotiate the intersection unless conflicting cross traffic is also required to stop; and
D. An intersection of two residential neighborhood collector (through) streets of similar design
and operating characteristics where multi-way stop control would improve traffic operational
characteristics of the intersection
The intersection does not appear to meet any of these criteria, so it is not a good candidate for a multi-way
stop sign installation.
To determine whether stop signs are warranted over yield signs, the MUTCD states:
Guidance:
At intersections where a full stop is not necessary at all times, consideration should first be given to using
less restrictive measures such as YIELD signs (see Sections 2B.08 and 2B.09).
The use of STOP signs on the minor-street approaches should be considered if engineering judgment
indicates that a stop is always required because of one or more of the following conditions:
A. The vehicular traffic volumes on the through street or highway exceed 6,000 vehicles per day;
B. A restricted view exists that requires road users to stop in order to adequately observe conflicting
traffic on the through street or highway; and/or
C. Crash records indicate that three or more crashes that are susceptible to correction by the installation
of a STOP sign have been reported within a 12-month period, or that five or more such crashes have been
reported within a 2-year period. Such crashes include right-angle collisions involving road users on the
minor-street approach failing to yield the right-of-way to traffic on the through street or highway.
Based on Condition B above, it is recommended that the existing yield signs on the Independence
Boulevard approaches be replaced with stop signs. As you can see in the images below, vehicles
traveling westbound on Independence Boulevard cannot see vehicles traveling northbound on Cannonball
Trail until they stop at the intersection.
Westbound Approach, Looking South 1
Westbound Approach, Looking South 2
It is our understanding that there may be a concern regarding speed on Cannonball Trail. This may be
more properly addressed with enforcement or if necessary traffic calming devices.
As requested, we investigated the possible installation of stop signs at the intersection of Cannonball Trail
and John Street. Our findings were as follows:
Currently there are yield signs at the approaches on John Street.
The intersection does appear to have sight distance constraints on the northwest corner of the
intersection.
The governing entity on traffic control signage is the Manual on Uniform Traffic Control Devices
(MUTCD). The manual states as follows in regards to stop sign installation:
Guidance:
Engineering judgment should be used to establish intersection control. The following factors
should be considered:
A. Vehicular, bicycle, and pedestrian traffic volumes on all approaches;
B. Number and angle of approaches;
C. Approach speeds;
D. Sight distance available on each approach; and
E. Reported crash experience.
YIELD or STOP signs should be used at an intersection if one or more of the following conditions
exist:
A. An intersection of a less important road with a main road where application of the normal
right-of-way rule would not be expected to provide reasonable compliance with the law;
B. A street entering a designated through highway or street; and/or
C. An unsignalized intersection in a signalized area.
In addition, the use of YIELD or STOP signs should be considered at the intersection of two
minor streets or local roads where the intersection has more than three approaches and where
one or more of the following conditions exist:
A. The combined vehicular, bicycle, and pedestrian volume entering the intersection from all
approaches averages more than 2,000 units per day;
B. The ability to see conflicting traffic on an approach is not sufficient to allow a road user to
stop or yield in compliance with the normal right-of-way rule if such stopping or yielding is
necessary; and/or
C. Crash records indicate that five or more crashes that involve the failure to yield the right-of-
way at the intersection under the normal right-of-way rule have been reported within a 3-year
period, or that three or more such crashes have been reported within a 2-year period.
Yield or Stop signs should not be used for speed control.
Memorandum
To: Bart Olson, City Administrator
From: Brad Sanderson, EEI
CC: Eric Dhuse, Director of Public Works
Krysti Barksdale-Noble, Community Dev. Dir.
Lisa Pickering, Deputy City Clerk
Date: September 6, 2017
Subject: Cannonball Trail and John Street Stop Sign
Since the traffic volume is above 2,000 units per day and there are sight distance constraints on the
northwest corner of the intersection, the intersection is a good candidate for a two-way intersection
control.
The MUTCD states as follows in regards to multi-way stop sign installation:
Guidance:
The decision to install multi-way stop control should be based on an engineering study.
The following criteria should be considered in the engineering study for a multi-way STOP sign
installation:
A. Where traffic control signals are justified, the multi-way stop is an interim measure that can be
installed quickly to control traffic while arrangements are being made for the installation of the
traffic control signal.
B. Five or more reported crashes in a 12-month period that are susceptible to correction by a
multi-way stop installation. Such crashes include right-turn and left-turn collisions as well as
right-angle collisions.
C. Minimum volumes:
1. The vehicular volume entering the intersection from the major street approaches (total
of both approaches) averages at least 300 vehicles per hour for any 8 hours of an
average day; and
2. The combined vehicular, pedestrian, and bicycle volume entering the intersection from
the minor street approaches (total of both approaches) averages at least 200 units per
hour for the same 8 hours, with an average delay to minor-street vehicular traffic of at
least 30 seconds per vehicle during the highest hour; but
3. If the 85th-percentile approach speed of the major-street traffic exceeds 40 mph, the
minimum vehicular volume warrants are 70 percent of the values provided in Items 1 and
2.
D. Where no single criterion is satisfied, but where Criteria B, C.1, and C.2 are all satisfied to 80
percent of the minimum values. Criterion C.3 is excluded from this condition.
Option:
Other criteria that may be considered in an engineering study include:
A. The need to control left-turn conflicts;
B. The need to control vehicle/pedestrian conflicts near locations that generate high pedestrian
volumes;
C. Locations where a road user, after stopping, cannot see conflicting traffic and is not able to
negotiate the intersection unless conflicting cross traffic is also required to stop; and
D. An intersection of two residential neighborhood collector (through) streets of similar design
and operating characteristics where multi-way stop control would improve traffic operational
characteristics of the intersection
The intersection does not appear to meet any of these criteria, so it is not a good candidate for a multi-way
stop sign installation.
To determine whether stop signs are warranted over yield signs, the MUTCD states:
Guidance:
At intersections where a full stop is not necessary at all times, consideration should first be given to using
less restrictive measures such as YIELD signs (see Sections 2B.08 and 2B.09).
The use of STOP signs on the minor-street approaches should be considered if engineering judgment
indicates that a stop is always required because of one or more of the following conditions:
A. The vehicular traffic volumes on the through street or highway exceed 6,000 vehicles per day;
B. A restricted view exists that requires road users to stop in order to adequately observe conflicting
traffic on the through street or highway; and/or
C. Crash records indicate that three or more crashes that are susceptible to correction by the installation
of a STOP sign have been reported within a 12-month period, or that five or more such crashes have been
reported within a 2-year period. Such crashes include right-angle collisions involving road users on the
minor-street approach failing to yield the right-of-way to traffic on the through street or highway.
Based on Condition B above, it is recommended that the existing yield signs on the John Street
approaches be replaced with stop signs. As you can see in the images below, vehicles traveling eastbound
on John Street cannot see vehicles traveling southbound on Cannonball Trail until they stop at the
intersection.
Eastbound Approach, Looking North 1
Eastbound Approach, Looking North 2
It is our understanding that there may be a concern regarding speed on Cannonball Trail. This may be
more properly addressed with enforcement or if necessary traffic calming devices.
As requested, we investigated the possible installation of stop signs at all of the intersections located
within Autumn Creek Unit 2C (Emerald Lane and Lilac Way/Violet Court, Emerald Lane and Ruby
Drive, Emerald Lane and Slate Drive/Slate Court, and Slate Drive and Lilac Way/Lilac Court). Our
findings were as follows:
Currently there is no signage control at any of the intersections.
The intersections do not appear to have any sight distance constraints.
The governing entity on traffic control signage is the Manual on Uniform Traffic Control Devices
(MUTCD). The manual states as follows in regards to stop sign installation:
Guidance:
Engineering judgment should be used to establish intersection control. The following factors
should be considered:
A. Vehicular, bicycle, and pedestrian traffic volumes on all approaches;
B. Number and angle of approaches;
C. Approach speeds;
D. Sight distance available on each approach; and
E. Reported crash experience.
YIELD or STOP signs should be used at an intersection if one or more of the following conditions
exist:
A. An intersection of a less important road with a main road where application of the normal
right-of-way rule would not be expected to provide reasonable compliance with the law;
B. A street entering a designated through highway or street; and/or
C. An unsignalized intersection in a signalized area.
In addition, the use of YIELD or STOP signs should be considered at the intersection of two
minor streets or local roads where the intersection has more than three approaches and where
one or more of the following conditions exist:
A. The combined vehicular, bicycle, and pedestrian volume entering the intersection from all
approaches averages more than 2,000 units per day;
B. The ability to see conflicting traffic on an approach is not sufficient to allow a road user to
stop or yield in compliance with the normal right-of-way rule if such stopping or yielding is
necessary; and/or
C. Crash records indicate that five or more crashes that involve the failure to yield the right-of-
way at the intersection under the normal right-of-way rule have been reported within a 3-year
period, or that three or more such crashes have been reported within a 2-year period.
Yield or Stop signs should not be used for speed control.
Memorandum
To: Bart Olson, City Administrator
From: Brad Sanderson, EEI
CC: Eric Dhuse, Director of Public Works
Krysti Barksdale-Noble, Community Dev. Dir.
Lisa Pickering, Deputy City Clerk
Date: September 13, 2017
Subject: Autumn Creek Unit 2C Stop Signs
Since the traffic volumes would appear to be below 2,000 units per day, there are no sight distance
constraints and there does not appear to be an accident history, these intersections do not appear to be a
good candidate for a stop sign based on the above criteria. Generally, at an unsigned intersection, the
application of the normal right-of-way rules would apply.
Figure D taken from the Illinois Drivers Manual shows that the minor roadway should yield to traffic on
the major roadway at uncontrolled intersections.
Have a question or comment about this agenda item?
Call us Monday-Friday, 8:00am to 4:30pm at 630-553-4350, email us at agendas@yorkville.il.us, post at www.facebook.com/CityofYorkville,
tweet us at @CityofYorkville, and/or contact any of your elected officials at http://www.yorkville.il.us/320/City-Council
Agenda Item Summary Memo
Title:
Meeting and Date:
Synopsis:
Council Action Previously Taken:
Date of Action: Action Taken:
Item Number:
Type of Vote Required:
Council Action Requested:
Submitted by:
Agenda Item Notes:
Reviewed By:
Legal
Finance
Engineer
City Administrator
Human Resources
Community Development
Police
Public Works
Parks and Recreation
Agenda Item Number
New Business #6
Tracking Number
PW 2017-63
Water Ordinance
Public Works Committee – September 19, 2017
Majority
Approval
See attached memo.
Erin Willrett Administration
Name Department
Summary
Attached you will find the staff recommended revisions to the City’s Codified Ordinance Title 7
Chapter 5 Water Use and Service. Staff began meeting to revise this Chapter in the Fall of 2016 and
reviewed it section by section. Engineering and Legal has also reviewed the recommended changes.
Background
The red-lined version is attached for your reference. A lot of the changes are updates to match
the current practice of the department or to match current legislation. A few key revisions from the
Ordinance are listed below:
Throughout the document staff added a reference to the most recent City Subdivision Control
Ordinance for a specification reference.
All references to the Superintendent of Public Works have been changed to the Director of
Public Works.
All references to the City Treasurer have been changed to the Finance Director.
Bulk Water has been updated from $5.00 to $50.00 per load.
Staff updated the Residential Connection Fee table as outlined in the Master Water Study that
EEI authored. This assumes a cost calculated of $1,587.00 per PE from the previous calculation
of $1,057.00 per PE.
Changing the water meter testing threshold to meters that are at two percent accuracy, instead of
four percent so that more accurate reads can be made.
Proposed change to multi-unit buildings, mandating that each unit must be serviced by a single
meter. In the case that that is not feasible, if there are delinquent accounts in the multi-unit
building, the entire building may be shut-off, if it is attached by one meter to all units.
Updated the turn-on fee to $50.00 (currently $5.00). This is an accurate reflection of staff time
and transportation costs to turn-off/turn-on a unit that had been disconnected.
A comparison from current to proposed language is listed below for your use. Several sections have
been modified and a side-by-side comparison is used.
Memorandum
To: Public Works Committee
From: Erin Willrett, Assistant City Administrator
CC: Bart Olson, City Administrator
Date: September 19, 2017
Subject: Revision to Title 7 Chapter 5 Water Use and Service
Proposed Change 1
Section 7-5-1: Water Department:
CURRENT LANGUAGE
A. Supervision: The Water Department of the City shall be under the active supervision of the
city administrator/engineer who shall report to the Public Works Committee the water committee
of the city council. Said city administrator/engineer shall make a written report to the City
Council of all his acts and doings whenever requested by the Council and such reports shall be
placed on file with the City Clerk and shall show the kind and amount of materials used, the cost
thereof and all expenses attending the work. He shall also keep a correct map of all water mains
now or hereinafter laid in the City, with their dimensions, locations and connections, hydrants
and cutoffs; and shall keep just, true and correct books of accounts, and such book, records, maps
and other accounts shall be delivered to his successor or the City Council at any time, upon
request.
PROPOSED LANGUAGE
A. Supervision: The Water Department of the City shall be under the supervision of the
Director of Public Works who shall report to the City Council the activities of the Department
whenever requested by the Council. He shall also keep a correct map of all watermains in the
City, with their dimensions, locations and connection, hydrants and cutoffs; and shall keep such
books, records, maps and other accounts, which shall be delivered to his successor.
Proposed Change 2
Section 7-5-1: Water Department:
CURRENT LANGUAGE
B. 1. Salaries and Wages: Superintendent of Public Works: The Superintendent of Public
Works shall receive his wages from the water fund for his services in the active supervision of
said waterworks; such sum to be the current compensation policies fixed by resolution and set
forth in the annual budget ordinance.
PROPOSED LANGUAGE
B. 1. Salaries and Wages: Director of Public Works: The Director of Public Works may
receive his wages from the water fund for his services in the active supervision of said
waterworks; such sum to be determined by the current City compensation policies.
Proposed Change 3
Section 7-5-1: Water Department:
CURRENT LANGUAGE
B. 2. Department Employees: The mayor and members of the city council shall have the
authority to hire all other employees necessary for the proper operation and management of the
waterworks. The wages of all such employees shall be fixed by resolution, and all wages and
other expenses of the water department shall be paid out of the water fund through vouchers
authorized and drawn in the like manner all other vouchers; except that such amounts shall be
paid only out of the water fund.
PROPOSED LANGUAGE
B. 2. Department Employees: The Mayor, or his designee, shall have the authority to hire and
fire all other employees necessary for the proper operation and management of the waterworks,
all wages and other expenses of the water department may be paid out of the water fund in
accordance with the budget as approved by the City Council.
Proposed Change 4
Section 7-5-1: Water Department:
PROPOSED DELETION
C. Audit of Department: The City Council shall cause a proper audit to be made at least once
each year of the Water Department. The report of such audit shall be open for inspection at all
proper times to any taxpayer, water user or any holder of bonds issued by the Water
Department.
Staff note - The audit is done annually for all City accounts. This language is redundant and
therefore, proposed to be deleted.
Proposed Change 5
Section 7-5-2: Applications for Water Service and Connections
CURRENT LANGUAGE
All applications for water service connections and for water service shall be made in writing on
forms to be furnished by the City. No approval for water service connection shall be granted
unless and until said forms are filled out and signed by the applicant and until all fees for
connection and meter are submitted.
PROPOSED LANGUAGE
All applications for water service connections and for water service shall be made in writing on
forms to be furnished by the City. No approval for water service connection shall be granted
unless and until said forms are completed and signed by the applicant with all fees for
connection and meter. No connection to a water main shall be made without a permit being
issued and 24 hour notice to the Director of Public Works. No water from the city water supply
shall be turned on for service into any premises by any person until the water meter has been
installed and is registering all water used at the premises.
Staff note - This language is clear and implicit when it comes to connections and who is allowed
to turn on the water service.
Proposed Change 6
Section 7-5-3: Water Service Connections and Installation
PROPOSED DELETION
A: “Projected PE Per Residence”
Staff note - The City has already considered this within the calculation and is listed as a total in
the chart below. Therefore, staff is recommending removing the number from the chart and only
listing the Proposed Connection Fee.
Proposed Change 7
Section 7-5-3: Water Service Connections and Installation
PROPOSED AMENDED RESIDENTIAL CONNECTION FEE TABLE:
Staff updated Residential Connection Fee table as outlined in the Master Water Study that EEI
authored. This assumes a cost calculated of $1,587.00 per PE from the previous calculation of
$1,057.00 per PE. The columns in the table below in black are proposed to be deleted to show
the new PROPOSED cost calculated. The study recommends the new calculation shown, which
is based on a portion of total cost based off of Average Daily Demand. See image below of the
calculations and assumption from the Master Water Study.
For example, a Single Family Home is CURRENTLY calculated by 3.5 PE multiplied by the
Current Fee of $1,057.00 which would equal a Connection Fee of $3,700.00. Staff is
PROPOSING the calculation for a Single Family Home by calculating the same 3.5 PE
multiplied by the Proposed Connection Fee of $1,587.00 which would equal a Connection Fee of
$5,554.00. The proposed increase is $1,854.00 (33.3%) for a Single Family Home.
RESIDENTIAL CONNECTION FEES
Residence Type
PE/Type Current Fee
* PE
Current
Connection Fee
PROPOSED
Fee * PE
PROPOSED
Connection
Fee
Efficiency or studio
apartment
1 $1,057.00 $1,057.00 $1,587.00 $1,587.00
1 bedroom
apartment/condominium
1.5 $1,057.00 $1,586.00 $1,587.00 $2,380.00
2 plus bedroom
apartment/condominium
3 $1,057.00 $3,171.00 $1,587.00 $4,761.00
1 bedroom townhome 1.5 $1,057.00 $1,586.00 $1,587.00 $2,380.00
2 plus bedroom
townhome
3 $1,057.00 $3,171.00 $1,587.00 $4,761.00
Duplex home 3 $1,057.00 $3,700.00 $1,587.00 $4,761.00
Single-family home 3.5 $1,057.00 $3,700.00 $1,587.00 $5,554.00
Proposed Change 8
Section7-5-3: Water Service Connections and Installation
CURRENT LANGUAGE
Item B Materials, Equipment and Labor 1. If the superintendent of public works so desires, he
may request the applicant furnish materials, equipment and labor to install the service
connection. Where such the request is made the materials used shall be approved by the
Superintendent of public works and the installer shall be bonded, qualified and approved by the
Superintendent of Public Works before installation. If the Superintendent of Public Works
provides any materials, equipment and labor to install the service connection, the cost of such
equipment, materials and labor for this installation of such connections shall be in additional to
the above charges.
PROPOSED LANGUAGE
Item B Materials, Equipment and Labor 1. The applicant shall furnish materials, equipment and
labor to install the service connection. The materials used shall be in compliance with this
Chapter and approved by the Director of Public Works and the installer shall be bonded,
qualified as a licensed plumber and approved by the Director of Public Works before
installation. If the Director of Public Works provides any materials, equipment and labor to
install the service connection, the cost of such equipment, materials and labor for the installation
of such connections shall be in addition to the above charges.
Proposed Change 9
Section 7-5-3: Water Service Connections and Installation
PROPOSED DELETION
Item B Materials, Equipment and Labor 2. “The installation of the service connection by
applicant shall be allowed only where connection will be made to the new watermains that are
not yet in service. Where connection is made to existing city owned watermains, the installation
of the service connection shall be made by the superintendent.”
Staff Note - That language does not represent current practice as the connection is not made by
the Superintendent. This language was deleted in its entirety.
Proposed Change 9
Section 7-5-4: Water Meters
CURRENT LANGUAGE
All water furnished consumers shall be metered, and all meters shall be of a standard and
approved make and shall be furnished by the City and set by the Water Department. Meters shall
remain the property of the City and are subject to removal any time.
PROPOSED LANGUAGE
All water furnished consumers shall be metered, and all meters shall be in compliance with this
Chapter, and shall be furnished by the City and set by the Water Department or licensed
plumber. Meters shall remain the property of the City and are subject to removal any time. It
shall be the responsibility of the property owner to furnish protection to the water meter from
theft, vandalism, breakage due to weather conditions or any other damages which may occur.
The property owner will be required to pay for any repair to or replacement costs of the water
meter if such is necessary (for other than normal maintenance); otherwise, the water meter is the
responsibility of the Department of Public Works for accuracy and maintenance, and/or
replacement.”
Staff Note - This language clearly defines who is monetarily responsible for repair or
replacement of the meter.
Proposed Change 10
Section 7-5-4-5: Meter Testing
PROPOSED LANGUAGE
A. Tests May be Made: “In case of doubt as to the accuracy of a meter, the consumer may
request a text to be made….and if the meter is found to measure more than TWO (2%)
incorrectly, no charge shall be made; and if an over-register of more than TWO percent (2%) is
found….If said meter registers within TWO percent (2%) of accuracy, then all expense of testing
shall be borne of the person making the request.”
Staff Note – The proposed language above is the same as the current language, except that staff
recommends the percentage change from FOUR to TWO percent to gain more accuracy to meter
reads.
Proposed Change 11
Section 7-5-4-7: Service to More than One Customer Through Single Meter:
CURRENT LANGUAGE
If, at the request of and for the convenience of the owner of a premises containing more than one
customer, water is furnished to said premises through a single meter for the purpose of
redistribution to the several customers, the charged set forth for service for a single family meter
shall be multiplied by the number of customers served and the product there from shall be the
water service connection charge.
PROPOSED LANGUAGE
SERVICE TO MULTI-FAMILY RESIDENTIAL BUILDINGS WITH ONLY A SINGLE METER
OR SHUT-OFF:
A. If water is furnished to a multi-family building through a single meter for the purpose of
redistribution to the several customers, the water service connection charge shall be the charge
for a single-family meter multiplied by the number of customers served.
B. No new water service shall be provided by the City to a multi-family building unless each
single-family dwelling unit has a separate meter and shutoff box. It is the expressed policy of the
City to prevent the establishment of and to encourage the elimination of all multi-family
buildings with only a single meter or shutoff box except as allowed in this section.
C. Effective August 1, 2018, service to a multi-family building with a single meter or shutoff
box shall be billed only in the name of the landlord/owner or his or her duly appointed agent
until such water service is exclusive to each single-family dwelling unit with meter and shutoff
box. Agents appointed to act for the landlord/owner must be identified and authorized in writing
to the City by the landlord/owner. The landlord/owner may also be a person, partnership or
corporate entity lawfully designated as being solely responsible for the payment of water service
to the City.
D. Whenever a disconnection is authorized for a multi-family building with a single meter or
shutoff box, water service shall not be reconnected until a separate shutoff box and meter is
installed for each single-family dwelling unit at the landlord/owner’s expense.
Staff Note - This language allows the City to have access to shut-off and/or turn-on in individual
residences in a multi-family dwelling unit.
Proposed Change 12
Section 7-5-5-1: Water Service Rates and Charges:
Staff Note – We changed the location of bulk water rates by moving those charges to this section
of the ordinance under a new Section D, and stipulated that the bulk water rate is $50 per load.
Proposed Change 13
Section 7-5-5-1: Water Service Rates and Charges:
PROPOSED DELETION
D. Temporary Water use; Unmetered Rates: The flat rate for water services supplied on a
temporary basis without meters shall be as follow.
Staff Note - This was removed because the practice is no longer in place, allowing all to
purchase a bulk water rate.
Proposed Change 14
Section 7-5-5-1: Water Service Rates and Charges:
PROPOSED DELETION
E. “Private Sprinkler and Fire Suppression Systems”
Staff Note - This is an old practice and is no longer in use.
Proposed Changes 15. 16, 17 & 18
Section 7-5-5-2: Bills for Service; Delinquencies:
PROPOSED LANGUAGE
A. First notice bills for water furnished shall be mailed on or about January 1, March 1, July 1,
September 1, and November 1 of each year.
Staff Note – This language reflects current practice, outlining the notice for bill dates (every
other month starting in January).
PROPOSED LANGUAGE
B. After 30 days from the mailing of the first bill and the bill not being paid a delinquent second
notice bill shall be mailed.
Staff Note – This will allow the second notice to be mailed 30 days from the mailing of the first
bill not being paid.
PROPOSED MODIFICATION
C. Turn-on fee increase from a $5.00 to a $50.00 fee.
Staff Note - Staff believes this accurately reflects the charge for administration and labor time for
the turn on.
PROPOSED DELETION
Section D. “Additional Deposit Required”
Staff Note - It is not the current practice to require an additional deposit for a delinquent user.
Proposed Change 19
Section 7-5-5-3: Responsibility of Water Service Customer:
PROPOSED ADDITIONAL LANGUAGE:
If the bill for a building with multiple units and a single meter with one owner who pays the bill
for all of the units is delinquent, the City may shut-off the entire building as provided in Section
7-5-5-2C.
Staff Note - This would only affect a multiple-unit building, as it would provide a way for the
staff to shut-off the building for delinquent payment. And also links to the shut-off access
described in Section 7-5-4-7.
Proposed Change 20
Section 7-5-6: Waterworks Revenue:
PROPOSED DELETION
C. – “Water Surplus Account and Water Bond Redemption Account”
Staff Note - These accounts are no longer active and do not apply.
Proposed Change 21
Section 7-5-7: Change of Residence By Water Service Customers:
PROPOSED MODIFICATION
Turn-on fee increase from a $5.00 to a $50.00 fee.
Staff Note - Staff believes this accurately reflects the charge for administration and labor time for
the turn on.
Proposed Change 22
Section 7-5-9: Prohibited Acts and Conditions:
CURRENT LANGUAGE
B. Unnecessary Waste of Water: Consumers shall prevent unnecessary waste of water and keep
all water outlets closed when not in actual use. If unnecessary waste of water takes place, the
City Council reserves the right to cut-off the supply, and City further reserves the right to
prohibit the use of water for yard sprinklers, elevators and large consumers of water when, in the
judgment of the Council, it shall be necessary to do so.
PROPOSED LANGUAGE
B. It shall be the duty of all consumers of city water, at any times, to exercise due diligence to
prevent waste of the water supply and to this end shall stop any leaks on their premises. The city
water supply will be shut-off from any and all premises until such violation of this rule is
corrected.
Proposed Change 23
Section 7-5-9: Prohibited Acts and Conditions:
PROPOSED ADDITIONAL LANGUAGE
C. 5.: Resale of Water Prohibited: No water shall be resold or distributed by the recipient
thereof from the City supply to any premises at a rate other than that charged by the City. A
person who resells water from the City supply shall not add any additional costs or charges to
the rate charged by the City, other than any applicable administrative fee. The billing statement
shall include any applicable administrative fee as a separate line item on the bill. The line item
for the administrative fee shall also include the name of the entity that is charging the fee. Any
billing statement for water resale shall solely be in the name of the reseller or his or her assigns.
The billing statement shall not include any references to the City or the City’s logo.
Proposed Change 24
Section 7-5-9: Prohibited Acts and Conditions:
PROPOSED ADDITIONAL LANGUAGE
C. 6.: Damage to or Tampering with System: It is unlawful for any person not authorized by the
Director of Public Works to tamper with, alter, or injure any part of the City’s waterworks or
supply system or any meter.
Recommendation
Staff recommends approval of the attached revision to Title 7 Chapter 5 Water Use and Service
to the City’s Codified Ordinances.
Title 7
Chapter 5
WATER USE AND SERVICE
7-5-1: WATER DEPARTMENT:
7-5-2: APPLICATIONS FOR WATER SERVICE AND CONNECTIONS:
7-5-3: WATER SERVICE CONNECTIONS AND INSTALLATIONS:
7-5-4: WATER METERS:
7-5-4-1: METER COSTS:
7-5-4-2: METER LOCATIONS:
7-5-4-3: SIZE OF METERS:
7-5-4-4: MAINTENANCE AND REPAIR:
7-5-4-5: METER TESTING:
7-5-4-6: READING METERS:
7-5-4-7: SERVICE TO MORE THAN ONE CUSTOMER THROUGH SINGLE METER:
7-5-5: WATER SERVICE RATES; BILLING PROCEDURES:
7-5-5-1: WATER SERVICE RATES AND CHARGES:
7-5-5-2: BILLS FOR SERVICE; DELINQUENCIES:
7-5-5-3: RESPONSIBILITY OF WATER SERVICE CUSTOMER; DEPOSIT:
7-5-6: WATERWORKS REVENUE:
7-5-7: CHANGE OF RESIDENCE BY WATER SERVICE CUSTOMERS:
7-5-8: WATER SHUTOFFS AND TURNONS:
7-5-9: PROHIBITED ACTS AND CONDITIONS:
7-5-10: TEMPORARY SERVICE TO CONTRACTORS:
7-5-11: REGULATIONS FOR DEVELOPERS:
7-5-12: PRIVATE SPRINKLER AND FIRE PROTECTION SYSTEMS:
7-5-13: WATER CUSTOMER CONTRACTUAL AGREEMENT:
7-5-14: VIOLATION AND PENALTY (REP. BY ORD. 2008-74, 8-26-2008):
7-5-15: WATER CONSERVATION REGULATIONS:
7-5-16: INSPECTION; AUDIT; APPEAL:
7-5-1: WATER DEPARTMENT:
A. Supervision: The Water Department of the City shall be under the active supervision of the
the city administrator/engineer Director of Public Works who shall report to the PUlic Works
Committee the water committee of the city council. who.Said city administrator/engineer Said
Director shall make a written report to the City Council the activities of the Departmentof all
his acts and doings whenever requested by the Council, and such reports shall be placed on
file with the City Clerk and shall show the kind and amount of materials used, the cost thereof
and all expenses attending the work. He shall also keep a correct map of all water mains now
or hereinafter laid in the City, with their dimensions, locations and connections, hydrants and
cutoffs; and shall keep just, true and correct books of accounts, and such books, records, maps
and other accounts which shall be delivered to his successor or the City Council at any time,
upon request.
B. Salaries And Wages:
1. Superintendent Director Oof Public Works: The Superintendent Director of Public
Works shall may receive his wages from the water fund for his services in the active
supervision of said waterworks; such sum to be determined by the current City
compensation policies. compensation policies fixed by resolution and set forth in the
annual budget ordinance. (Ord 1974, 69, 10 24 1974; and 19953 Code).
2. Department Employees: The mayor and members of the city council The Mayor, or his
designee, shall have the authority to hire and fire all other employees necessary for the
proper operation and management of the waterworks, The wages of all such employees
shall be fixed by resolution, and all wages and other expenses of the water department
mayshall be paid out of the water fund through vouchers authorized and drawn in the
like manner s all other vouchers; except that such amounts shall be paid only out of the
water fund. in accordance with the budget as approved by the City Council.
C. Audit Of Department: The City Council shall cause a proper audit to be made at least once
each year of the Water Department. The report of such audit shall be open for inspection at all
proper times to any taxpayer, water user or any holder of bonds issued by the Water
Department. (Ord. 1974-69, 10-24-1974)
7-5-2: APPLICATIONS FOR WATER SERVICE AND CONNECTIONS:
All applications for water service connections and for water service shall be made in writing on
forms to be furnished by the City. No approval for water service connection shall be granted
unless and until said forms are completedfilled out and signed by the applicant withand until all
fees for connection and meter are submitted. No connection to a water main shall be made
without a permit being issued and twenty-four (24) hours notice to the Director of Public Works.
No water from the City water supply shall be turned on for service into any premises by any
person until the water meter has been installed and is registering all water used at the premises.
(Ord. 1974-69, 10-24-1974)
7-5-3: WATER SERVICE CONNECTIONS AND INSTALLATIONS:
A. Location Of Connections And Installations Charge: All connections and installations of water
service shall, upon application, be made from the existing main upon applicant's street to the
street side of applicant's sidewalk or to a point four feet (4') within the curb line, whichever
point the Superintendent Director of Public Works shall determineso elect. Said connections
and installations shall be witnessed by authorized employees of the City and only after
payment by the user or property owner at the time of application for water to the Finance
DirectorCity Treasurer or collector of a connection fee as outlined below: (Ord. 1982-9, 3-25-
1982; amd. 1994 Code)
RESIDENTIAL CONNECTION FEES1
Residence Type
Projected
PE Per
Residence
Connection Fee Based On $ 1,057.00/PE
Efficiency or studio apartment 1.00 $ 1,057.001,587.00
1 bedroom apartment/condominium 1.50 $1,586.002,380.00
Formatted: Font: 12 pt
2 plus bedroom apartment/condominium
3.00 $4,761.003,171.00
1 bedroom townhome 1.50 $1,586.002,380.00
2 plus bedroom townhome 3.00 $3,171.004,761.00
Duplex home 3.50 $3,700.004,761.00
Single-family home 3.50 $3,700.005,554.00
NON-RESIDENTIAL CONNECTION FEES2
Water Meter Size Water Connection Fee
Less than or equal to 1 inch $ 3,700.00
11/2 inch 4,000.00
2 inch 5,000.00
3 inch 8,000.00
4 inch 15,000.00
6 inch and larger TBD
Notes:
The above connection fees shall not include the connection only for supplying water for fire
suppression.
Non-residential land use shall be considered all land uses other than those defined in the
residential connection fees table.
TBD = Connection fee to be determined by City Council on a case by case basis.
(Ord. 2006-32, 4-25-2006)
B. Materials, Equipment And Labor:
1. If the superintendent of public works so desires, he may request The applicant will
shall furnish materials, equipment and labor to install the service connection. Where such
request is made the The materials used shall be in compliance with this Chapter and
approved by the Superintendent Director of public Public Wworks and the installer shall
be bonded, qualified as a licensed andplumber and approved by the Superintendent
Director of Public Works before installation. If the Superintendent Director of Public
Works provides any materials, equipment and labor to install the service connection, the
cost of such equipment, materials and labor for the installation of such connections shall
be in addition to the above charges.
2. The installation of the service connection by applicant shall be allowed only where
connection will be made to the new watermains that are not yet in service. Where
connection is made to existing city owned water mains, the installation of the service
connection shall be made by the superintendent.
C. Construction Specifications: All service connections and installations shall be in compliance
with the City’s then effective Standard Specifications For Improvements adopted by the City
Council provided with corporation cock, curb stopcock, shutoff and curb box and of a
standard and approved type, and shall be subject to approval by the Superintendent Director of
Public Works. All materials, including pipe, stopcock and valves shall be of a standard and
approved type and placed and located under the direction of the Superintendent Director of
Public Works. (Ord. 1982-9, 3-25-1982; amd. 1994 2016 Code)
7-5-4: WATER METERS:
All water furnished consumers shall be metered, and all meters shall be in compliance with this
Chapterof a standard and approved make, and shall be furnished by the City and set by the Water
Department or licensed plumber. Meters shall remain the property of the City and are subject to
removal any time. It shall be the responsibility of the property owner to furnish protection to the
water meter from theft, vandalism, breakage due to weather conditions or any other damages
which may occur. The property owner will be required to pay for any repair to or replacement
costs of the water meter if such is necessary (for other than normal maintenance); otherwise, the
water meter is the responsibility of the Department of Public Works for accuracy and
maintenance, and/or replacement. (Ord. 1974-69, 10-24-1974)
7-5-4-1: METER COSTS:
All meters and shall be purchased fromthrough the City at the then current prices as established
by the City Council and will include the meter, couplers, gaskets, back flow prevention device
(for residential units only) meter wire and outside reader.
Applicants purchasing non-residential meters will be required to purchase an approved back flow
prevention device separately. Prices of water meters will be reviewed from time-to-time by the
City Council and set by ordinance.
Residential Meter Costs
5/8”x3/4” - $435.00
¾”x3/4” - $460.00
* 1” - $590.00
* used only when necessitated by plumbing code
Non-Residential Meter Costs
1 ½” - $1900.00
2” - $2110.00
3” - $2600.00
The costs involved in furnishing and installing the meter shall be borne by the applicant. Costs
to be reimbursed to the city shall include the meter, remote readers, valves, checkvalves, meter
setting hardware and labor. The charges shall be actual cost for materials and labor including
fringe benefits, but excluding any fees for overhead, profit or similar marginal costs. (Ord. 1974
69, 10 24 1974)
7-5-4-2: METER LOCATIONS:
The owners must shall provide suitable locations in the water piping systems for the metersame
and meters shall be placed on a service pipe not to exceed two feet (2') from the wall where such
pipe enters the premises. The owner shall provide a shutoff valve on the inlet side of the meter
and a shutoff valve on the outlet side of the meter. The City shall provide a suitable check valve
on the outlet side of the meter. The City shall provide a suitable check valve on the outlet side of
the meter. There shall be provided a suitable place for the meter so as to keep it dry and clean,
and readily accessible at all times to the meter reader and inspector of the Water Department.
(Ord. 1974-69, 10-24-1974)
7-5-4-3: SIZE OF METERS:
A. The size of meter required for any metered water supply shall be governed by the size and
character of the premises served or to be served, as determined by the Building Code Official,
in accordance with City Building Codes. The size of meters so specified shall be subject to
change from time to time as demand or other condition may require.
B. The City mayright is reserved to require an increase or decrease in the size of a meter in any
case where, in the discretion of the City, the use of water exceeds the capacity of the meter or
the use is not accurately measured. (Ord. 1974-69, 10-24-74)
7-5-4-4: MAINTENANCE AND REPAIR:
Owners or occupants shall be responsible for the care and protection of a meter, but a meterthe
same shall be subject to inspection and test at any reasonable time by the Water Department;
however, meters may be repaired by the City at no cost to the owner and no oneDepartment. No
person shall interfere with the registration of or break a seal on any meter; providing, however,
that the Superintendent Director of Public Works may grant permission to break a seal for
draining pipe or stopping leaks. (Ord. 1974-69, 10-24-74; 1994 Code)
7-5-4-5: METER TESTING:
A. Tests May be Made: In case of doubt as to the accuracy of a meter, the consumer may request
acomplain and tests tomay be made by the Superintendent Director of Public Works and if the
meter is found to measure more than four two percent (42%) incorrectly, no charge shall be
made; and if an over-register of more than four two percent (42%) is found, a proportional
deduction shall be made from the previous water bill. If said meter registers within four two
percent (42%) of accuracy, then all expense of testing shall be borne by the person making the
requestcomplaint. (Ord. 1974-69, 10-24-74; amd. Ord. 1983-15, 9-22-83; 1994 Code)
B. Entry Powers: The Superintendent Director of Public Works or his designated employees in
the City Water Department,Department shall be allowed access at any reasonable time to the
residences of all City water users for the purposes of checking the accuracy of the water meter
located in the home when the home is equipped with a remote water meter indicator on the
outside of the residence at all reasonable times. (Ord. 1984-1, 3-22-84)
7-5-4-6: READING METERS:
The Superintendent Director of Public Works shall determine the amount of water usage by each
individual customer of the City pursuant to any of the following three methodsfollowing
methods to be selected by him in his absolute and sole discretion:
A. An actual meter reading done by physical examination of the water meter or remote radio
read, by employees of the City Water Department on a quarterly basis, but no less than one
time a year on a bi-monthly basis; or
B. A customer meter reading returned to the City Water Department at the request of the
Superintendent of Public Works by the customer; or
B. An estimated reading based on customer's usage. during the quarter being estimated from the
last one year of the customer’s usage. In the event any specific customer has less than a one
year history of water usage with the City, said estimates Estimates shall be based on the most
recently ascertainable data on individual usage available to the Superintendent Director of
Public Works. In no event shall estimated water billings be made for more than three (3)
calendar quarters consecutive billing periods in any one year. (Ord. 1984-1, 3-22-84)
7-5-4-7: SERVICE TO MORE THAN ONE CUSTOMER THROUGH SINGLE METER:
If, at the request of and for the convenience of the owner of a premises containing more than one
customer, water is furnished to said premises through a single meter for the purpose of
redistribution to the several customers, the charges set forth for service for a single family
meter shall be multiplied by the number of customers served and the product there from shall
be the water service connection charge. (Ord. 1974 69 10 24 74; 1994 Code)
7-5-5: WATER SERVICE RATES; BILLING PROCEDURES:
7-5-4-7: SERVICE TO MULTI-FAMILY RESIDENTIAL BUILDINGS WITH ONLY A
SINGLE METER OR SHUTOFF
A. If water is furnished to a multi-family building through a single meter for the purpose of
redistribution to the several customers, the water service connection charge shall be the charge
for a single-family meter multiplied by the number of customers served.
B. No new water service shall be provided by the City to a multi-family building unless each
single-family dwelling unit has a separate meter and shutoff box. It is the expressed policy of the
City to prevent the establishment of and to encourage the elimination of all multi-family
buildings with only a single meter or shutoff box except as allowed in this section.
C. Effective August 1, 2018, service to a multi-family building with a single meter or
shutoff box shall be billed only in the name of the landlord/owner or his or her duly appointed
agent until such water service is exclusive to each single-family dwelling unit with meter and
shutoff box. Agents appointed to act for the landlord/owner must be identified and authorized in
writing to the City by the landlord/owner. The landlord/owner may also be a person, partnership
or corporate entity lawfully designated as being solely responsible for the payment of water
service to the City.
D. Whenever a disconnection is authorized for a multi-family building with a single meter or
shutoff box, water service shall not be reconnected until a separate shutoff box and meter is
installed for each single-family dwelling unit at the landlord/owner’s expense.”
7-5-5-1: WATER SERVICE RATES AND CHARGES:
A. Water Infrastructure Improvement And Maintenance Fee; Water Service Rates Established:
1. All water users shall be charged a water infrastructure improvement and maintenance fee
of four dollars eight dollars twenty five cents ($8.254.00) per month through April 30,
20137. (Ord. 2012-18, 6-26-2012, 2016 Code)
2. Water service rates shall be as follows:
a. Effective May 1, 2014, the water rates shall be:
$14.00 up to 350 cubic feet of usage
$2.97 per 100 cubic feet of usage over 350 cubic feet (Ord. 2014-14, 4-22-2014)
b. Effective May 1, 2015, the water rates shall be:
$16.00 up to 350 cubic feet of usage
$3.65 per 100 cubic feet of usage over 350 cubic feet (Ord. 2015-22, 4-28-2015)
c. Effective May 1, 2016, the water rates shall be:
$17.00 up to 350 cubic feet of usage
$4.30 per 100 cubic feet of usage over 350 cubic feet
d. Effective May 1, 2017, the water rates shall be:
$17.00 up to 350 cubic feet of usage
$4.30 per 100 cubic feet of usage over 350 cubic feet
e. Effective May 1, 2018, the water rates shall be:
$17.00 up to 350 cubic feet of usage
$4.30 per 100 cubic feet of usage over 350 cubic feet (Ord. 2014-14, 4-22-2014)
3. In determining the quantity used for billing purposes, one hundred (100) cubic feet shall
include any fractional amount of cubic feet used. (Ord. 2010-21, 5-25-2010)
B. More Than One Water Customer Through A Single Meter: After the effective date hereof,
Eeach residential dwellinghousing unit or individual multi-tenant commercial tenant
unitdevelopments will be charged for water as outlined in this section, regardless of the
number of housing or commercial units that are served through a single meter. (Ord. 1982-9,
3-25-1982; amd. 1994 Code)
C. Users Outside City Limits:
1. Water Rates: For all water consumption and water services rendered beyond the city
limits for which each service shall be by meter registration, charges shall now be at the
normal in city water rates and no further double charge shall be made.
1. Water Line And Plant Maintenance Fee: From January 1, 1984, forward, a water line and
plant maintenance fee shall be charged at the rate of six dollars and seventy cents ($6.70)
per month to be paid with each water bill, and upon the same terms, conditions and
enforcements for each water service meter registration outside of the City; with said water
line and plant maintenance fee being established herein by reason of the additional costs,
which may vary from time to time, incurred by the City in maintaining and servicing a
water delivery system not within its boundaries. (Ord. 1983-17, 12-15-1983)
D. Bulk Water Rates: Bulk water rates are $50.00 per load.
D. Temporary Water Use; Unmetered Rates: The flat rate for water services supplied on a
temporary basis without meters shall be as follows:
Filling outdoor swimming pools $ 75 .00
Outdoor shows, including carnivals, circuses and wild west shows, per day 105 .00
Unmetered service generally, per day 30 .00
(Ord. 1982-9, 3-25-1982)
E. Private Sprinkler And Fire Protection Systems: The following rates and charges shall apply to
all sprinkler and fire protection services connected with the water mains of the city:
1. Sprinkler system service:
For each connection serving 500 sprinkler heads or less, semiannually $12 .50
For each additional sprinkler head on any connection, over 500 heads,
semiannually
$0.015 each
2. Fire protection service:
For each fire hydrant located on private property, semi-annually $5 .00
For each wet hose connection on private property, semi-annually 1 .00
Sprinkler and fire protection service rates and charges shall not be subject to any discount. Such
rates and charges shall be considered as payment only for such water as may be necessary to use
in making the usual and ordinary tests of such systems under the underwriters' rules, or for actual
fires. Sprinkler and fire protection service shall not be required to be metered unless it shall be
found that water is used from same for purposes other than for the usual tests or for firefighting,
in which case the city is empowered to require the installation of a meter. (Ord. 1974-69, 10-24-
1974)
7-5-5-2: BILLS FOR SERVICE; DELINQUENCIES:
A. Rendition Of Bills; Payment, First Notice: First notice bills for water furnished shall be
mailed on or about July 1, October 1, January 1 and April 11 January 1, March 1, May 1, July
1, September 1, and November 1of1 of each year, and all first notice bills and charges for
water usagerents and other services are payable at the office of the Finance Director within 30
days of the date of mailingCity Treasurer or collector. (Ord. 1982-9, 3-25-1982)
B. Delinquent Bills, Second Notice: After 30 days from the mailing of the first bill and the bill
not being paid a delinquent second notice bill shall be mailed. All charges for water shall be
due and payable on rendition by mail of first notice of amount to the owner or tenant and shall
become delinquent at the expiration of thirty (30) days from the respective rendition of first
notice bills date in section 7-5-5-2A above, or from the actual date of mailing of first notice
bills if the rendition by mail date occurs later than the respective rendition of bills date in
Section 7-5-5-2 A. above. The delinquent second notice bill amount shall be ten percent
(10%) greater than the first notice bill amount. The second notice bill shall be due ten (10)
days from its date ofthe respective mailing date. For purposes of enforcing a lien as provided
by statutes, the date of delinquency on the second notice bill is the first eligible lien date.
C. Shut-off Of Water Service For Nonpayment; Turn-on Fee; Payment Plan: Ten (10) daysIf a
delinquent after a bill is not paid before its due dateshall become delinquent, the water service
may be shut off from the premises, and shall not be turned on until all back rentals and
charges are paid, together with a five fifty dollar ($50.00) fee for turning on the water when
service is located within the City limits; said fee shall be ten fifty dollars ($1050.00) plus all
back rentals and charges when service is located beyond the City limits; provided however, at
the discretion of the City Finance Director, a water service customer may enter into a payment
plan with the City in order to avoid water shutoff. In this event the customer does not have a
prior history of delinquent bills and , the water service customer shall pays the entirety of the
current monthly charges, plus a portion of the delinquent charges as determined by the City
Finance Director and the customer does not have a prior history of delinquent bills, so long as
all delinquent sums are paid in full within not more than eighteen (18) months, the City shall
charge a ten (10%) percent penalty every two months on the past due balance. Nothing in this
section shall obligate the City to enter into a payment plan with a water service customer.
(Ord. 2010-14, 3-9-2010)
D. Additional Deposit Required: In the event a water user becomes more than ten (10) days
delinquent on two (2) or more separate occasions, the user may be required to furnish an
additional deposit to the city in an amount equal to one estimated bill or not less than twenty five
dollars ($25.00), and twenty five dollars ($25.00) in the case of all other property, and the city
may refuse to turn said water on again until the aforesaid deposit has been received. (Ord. 1982-
9, 3-25-1982)
7-5-5-3: RESPONSIBILITY OF WATER SERVICE CUSTOMER:
Water service accounts and charges shall be kept in the name of the owner of the property
served, except as to property owned by the state of Illinois. Only such owner shall be recognized
as the consumer, except where the tenant has the account in his/her name . When the account is
in the name of the tenant makes and maintains a deposit of an amount of money with the city
treasurer equal to the estimated water bills for the premises to be served to guarantee payment for
water service, but in no case shall such deposit be less than twenty-five dollars ($25.00). The
deposit shall accompany the application for service. Where no deposits are made or where the
deposit is not maintained, the owner of the premises served shall be held responsible for the
payment of all water rentals and all other proper charges in connection with water services to
said premises. Such payments shall be accepted from tenants if tendered by them, but accepting
payments from tenants shall not subsequently relieve the owner of the premises from the
responsibility of paying water rentals or other service charges when due or relieve the real estate
from the lien hereinbefore provided. Any deposit made upon application for service shall be
returned to consumer upon termination of service. If the bill for a building with multiple units
and a single meter with oneis owned by one common owner who pays the bill for all of the
unitsand has multiple units, with one shut-off location is delinquent, the City may shut-off the
entire building as provided in Section 7-5-5-2C4-7. until the entire building is up-to-date on
billing. (Ord. 1974-69, 10-24-1974)
7-5-6: WATERWORKS REVENUE:
A. Duties Of Finance DirectorCity Treasurer:
1. Monies To: All money due the water department from all purposes and sources,
including the collection of water usage chargesrents or rates, shall be paid to the Finance
directorCity Treasurer.
2. Custodian Of Funds: The Finance DirectorCity Treasurer shall be custodian of the funds
derived from income received from the waterworks system, and shall begive proper bonded
for the faithful discharge of his duties. The Finance DirectorTreasurer shall maintain
separate accounts as is necessary or required by law. in which shall be placed the interest
and sinking fund monies and another account in which shall be placed the depreciation
funds and all other funds necessary to provide for refunding outstanding certificates or
bonds payable out of water revenue.
B. Water Fund: All revenue derived from the sale of water as herein provided shall be kept
separate and apart by the Finance DirectorCity Treasurer from the other revenue of the City.
Said money shall be known as the water fund and shall be used exclusively for waterworks
purposes; that is, for the maintenance, extension, improvement and operation of said
waterworks, the retirement of waterworks bonds and certificates, and under no circumstances
shall this revenue be diverted to any other purpose unless authorized by City Council at any
time. (Ord. 1974-69, 10-24-1974)
C. Water Surplus Account And Water Bond Redemption Account: The city council deems that
in its best interest and required pursuant to the terms of an ordinance passed on May 8, 1969,
authorizing the issuance of revenue bonds for the purpose of improving its water system, to
create two (2) accounts, one designated as a surplus account in which any surplus monies
remaining after payment of those monies required to be paid into special accounts created under
section 8, subparagraphs (a) through (d) of said ordinance of May 8, 1969, and said account shall
be designated as a surplus account and bond redemption account upon the following terms and
conditions:
1. Surplus Account: A surplus account shall hereby be established pursuant to the terms of the
city ordinance passed May 8, 1969, providing that all monies remaining in the water fund of the
city established by said ordinance after all previously described payments shall be placed into the
surplus account at the close of each billing quarter. At the end of each fiscal year, a sum of not
less than fifty percent (50%) of the amount paid into said surplus account shall be transferred to a
bond redemption account created hereafter. The remaining balance contained in said surplus
account may be used for the improvement, extension or maintenance of the city water system.
2. Bond Redemption Account: The city hereby creates a bond redemption account which shall be
established at the close of the next fiscal year occurring upon the effective date hereof. Fifty
percent (50%) of those monies transferred at the close of each fiscal year from the surplus
account of the water fund of the city shall be placed in said bond redemption account so as to
provide funds with which to retire water bond obligations of the city. (Ord. 1985-16, 10-24-
1985)
7-5-7: CHANGE OF RESIDENCE BY WATER SERVICE CUSTOMERS:
No person, either owner or tenant, who, in changing his residence from one location to any other
location served by the water department, shall be given water service until any and all delinquent
water usage feesrentals which are charged against him at his former place of residence shall have
been paid in full, and no water at the new location shall be turned on and, if so, the same shall be
turned off until settlement of such delinquent water rental at the former location is made. A
charge of five fifty dollars ($50.00) for turning on water and renewing service shall be made, in
addition to the payment of the delinquent water usagerental or charges. (Ord. 1974-69, 10-24-
1974)
7-5-8: WATER SHUTOFFS AND TURNONS:
A. Authority To Shut-Off Water; Non-liability: The City shall not be held responsible by reason
of the breaking of any service pipe or apparatus, or for failure toin the supply of water. The
City, when necessary, without notice, may shut the water off in its mains for the purpose of
making repairs or extensions or for other purposes. No claims shall be made against tThe City
shall not be liable by reason of the breakage of any service pipe or service cock, or from other
damage that may result from the shutting off of water for repairing, laying or relaying mains,
hydrants or other connections. (Ord. 1974-69, 10-24-1974)
B. Requests For Water Shut-off And Turn-on:
1. Water Shut-off: Owners or consumers when they pay for water service desiring to
discontinue the use of water shall give notice thereof, in writing, to the superintendent
Director of Public Works, or his designee, who shall then cause the water to be turned off.
Water usagerents or charges for services shall continuebe made until such notice is given.
When water service is discontinued, all water rentals for such service shall become due and
payable. When water service is again desired after having been discontinued, a charge of
five dollars ($5.00) shall be made and collected before turning on water and renewing
service.
2. Water Turn-on: In turning on water, the City Council or the water department shall not
be responsible for any damage that may occur by reason of improper fixtures, open or
improper connections, or for any other causes. (Ord. 1974-69, 10-24-1974; amd. 1994
Code)
7-5-9: PROHIBITED ACTS AND CONDITIONS:
A. Electrical Grounding To Water System: No part of any water service, including the portion
owned or used by any user of water, shall be used as a ground for a radio, telephone and other
electrical system or appliance It shall be unlawful for any person to ground an electrical
system toBonding of the water supply system shall not be considered to be a ground.
B. Unnecessary Waste Of Water: Consumers shall prevent unnecessary waste of water and keep
all water outlets closed when not in actual use. If unnecessary waste of water takes place, the
City Council reserves the right to cut off the supply, and the City further reserves the right to
prohibit the use of water for yard sprinklers, elevators and large consumers of water when, in
the judgment of the Council, it shall be necessary to do so. (Ord. 1974-69, 10-24-1974)
B. It shall be the duty of all consumers of city water at any and all times to exercise due diligence
to prevent waste of the water supply and to this end shall stop any leaks on their premises. The
city water supply will be shut off from any and all premises until such violation of this rule is
corrected.
C. Use Of Ground Water Prohibited:
1. Prohibited: The use or attempt to use as a water supply, ground water from within the
corporate limits of the United City of Yorkville by the installation or drilling of wells or
by any other method is hereby prohibited within the City. (Ord. 2008-78, 8-26-2008)
2. Penalties: (Rep. by Ord. 2008-74, 8-26-2008)
3. Definitions:
PERSON: Any individual, partnership, firm, company, limited liability company,
corporation, association, joint stock company, trust, estate, political subdivision, or any
other legal entity, or their legal representative, agents, or assigns.
POTABLE WATER: Any water used for human or domestic consumption, including,
but not limited to, water used for drinking, bathing, swimming, washing dishes, or
preparing foods.
4. Memorandum Of Understanding: The Mayor of the United City of Yorkville is hereby
authorized and directed to enter into a memorandum of understanding with the Illinois
environmental protection agency ("Illinois EPA") in which the United City of Yorkville
assumes responsibility for tracking the remediation sites, notifying the Illinois EPA of
changes to the ordinances, and taking certain precautions when siting public potable
water supply wells. (Ord. 2005-50, 6-14-2005)
5. Resale of Water Prohibited: No water shall be resold or distributed by the recipient
thereof from the City supply to any premises at a rate other than that charged by the City.
A person who resells water from the City supply shall not add any additional costs or
charges to the rate charged by the City, other than any applicable administrative fee. The
billing statement shall include any applicable administrative fee as a separate line item on
the bill. The line item for the administrative fee shall also include the name of the entity
that is charging the fee. Any billing statement for water resale shall solely be in the name
of the reseller or his or her assigns. The billing statement shall not include any references
to the City or the City’s logo.
4. Damage to or Tampering with System: It is unlawful for any person not authorized by
the Director of Public Works to tamper with, alter, or injure any part of the City’s
waterworks or supply system or any meter.
Formatted: Font: (Default) Times New Roman,
12 pt
Formatted: Font: (Default) Times New Roman,
12 pt
Formatted: Font: (Default) Times New Roman,
12 pt
Formatted: Indent: Left: 0.25", No bullets or
numbering
Formatted: Font: (Default) Times New Roman,
12 pt
Formatted: Indent: First line: 0", Space
Before: 0 pt, After: 0 pt
7-5-10: TEMPORARY SERVICE TO CONTRACTORS:
A. If, during construction of a service installation on a three-quarter inch (3/4") or one inch (1")
tap, it is temporarily impossible to install a meter as required, the superintendent of public works
or the city council may, upon receipt of application, issue a temporary bulk water permit, and
turn on the service and allow use of unmetered water for normal construction purposes. Such
permit shall not exceed sixty (60) days after the date of issuance of the permit for construction of
said service installation.
B. The charges for temporary bulk water permit shall be ten dollars ($10.00) for each thirty (30)
days or less that a meter is not installed after issuance of a plumbing permit, and not to exceed a
total of sixty (60) days. Said charges shall be paid in advance of each period requested and
before water is turned on by the Department. (Ord. 1974-69, 10-24-74; 1994 Code)
7-5-10: REGULATIONS FOR DEVELOPERS:
A. Public Water Supply for Subdivisions: No subdivision of land in the corporate limits shall be
approved by the City Council unless the lots therein are provided with adequate water
connectionsng with the City water system, if at all practical. Water connections and City
water main extensions, if necessary in order to connect to the City water system, shall be at
the subdivider's expense but under the direct supervision and control of the Director of Public
WorksCity Council or its authorized agents. Prior to the time said extension is undertaken, the
subdividers shall pay the cost of said extension. Upon completion, any extension shall be
dedicated to the City and become property of the City who shall then assume full
responsibility for maintenance and repairs of the same.
B. Water System Improvements:
Use The standards and specifications from Title 11, subdivision control ordinance, of this
Code shall be used for contiguity and construction.
1. Where improvements and extensions to the water distribution system are required in
order to serve the needs of a development, the developer shall bear all costs ofin the
water main installation3. (Ord. 1974-69, 10-24-74)
2. Prior to proceeding with construction, the developer shall prepare and submit plans and
specifications to all Federal, State, County, Township and other governmental agencies
as required by law for p. Permits or approvals. shall be received from all appropriate
agencies. The contractor shall also submit plans and specifications to the Director of
Public Works and shall obtain written approval and a permit from the City Council
before proceeding with construction. The following requirements shall be met:
a. Plans and specifications submitted shall bear the seal of a current registered
Professional Engineer.
b. Water mains shall be not less than six eight inches (68") in diameter.
c. Fire hydrants shall be set at each intersection and at intervals not to exceed four
hundred feet (400') (whichever results in closer spacing). (Ord. 1974-69, 10-24-74)
(Ord. 1974-69, 10-24-74; 1994 Code)
d. All future water mains shall be constructed of ductile iron. Ductile iron valves and
appurtenances shall be used whenever possible; however, the Superintendent
Director of Public Works may, at his discretion, allow the use of cast iron valves and
other cast iron appurtenances to the actual water pipe upon his written consent to the
installer. (Ord. 1983-15, 9-22-83; 1994 Code)
e. Water mains shall be buried such that finished grade will provide not less than five
and one-half feet (51/2') of cover and not greater than eight and one-half feet (81/2') of
cover over the main.
f. All water main extensions shall be designed, installed and tested in accordance with
the the most current edition of the "Standard Specifications for Water and Sewer
Main Construction in Illinois". (Ord. 1974-69, 10-24-74)
g. The contractor shall pay all expenses incurred by the City to provide field inspections
and approval of water mains before, during and after construction. At the sole option
of the City, the following procedures shall be followed:
(1) Complete field inspection by the SuperintendentDirector of Public Works or his
agent, with free advice and consulting on the project by the design engineer;
(2) Complete field inspection by the design engineer for the developer with periodic
field checking by the Superintendent Director of Public Works or his agent;
(3) Complete field inspection by the design engineer for the developer. If the City
selects this option, there shall be submitted to the City a sworn statement
carrying the design engineer's signature and seal stating that the water system
was installed in strict accordance with the plans and specifications as approved,
except as shown in the as-built drawings. (Ord. 1974-69, 10-24-74; 1994 Code)
h. Mylar or cloth reproducible drawings shall be submitted to the City after
construction showing the system as-built. (Ord. 1974-69, 10-24-74; 2016 Codified)
C. Installation of Oversize Mains:
1. Notice Requiring Oversized Mains; Compliance:
a. When, in any subdivision now within the City or within one and one-half (11/2) miles
of the City limits which normally would require an eight inch (8") size water main but
which, for the purpose of complying with the plan of development of the City's water
system to provide an adequate water supply, not only to the particular subdivision but
also to subdivisions which in the future may become a part of the City, and where the
City Engineer and Superintendent Director of Public Works have determined that water
mains of a larger diameter than eight inches (8") and the size thereof, shall be installed,
then the City Engineer or the Superintendent Director of Public Works shall inform the
subdividers, builders and developers of the subdivision by a written notice of that fact
and require them to install such oversized water mains and at the same time, in said
notice, inform them of the size to be installed. (Ord. 1974-69, 10-24-74; 1994 Code)
b. Upon being so notified as provided for in this subsection, no subdivider, builder or
developer shall install any water main in such subdivision of any size other than that
specified to him by the aforesaid notice.
2. Costs: At such time as the installation of said oversized water main pipe shall have been
completed in accordance with the plans and specifications submitted to the City for such
installation, and also in accordance with the notice specified in this subsection, and all such
installations shall have been inspected and approved by the City as provided for by ordinance
of the City, then the City will pay any such subdivider, builder or developer who has installed
oversized water main pipe as above provided or approve a recapture ordinance, the difference
of the cost at current prices, as of the time of said installation, between the eight inch (8")
main pipe which was originally planned to be used and the cost of the oversized pipe which
the City directed to be used. (Ord. 1974-69, 10-24-74)
7-5-12: PRIVATE SPRINKLER AND FIRE PROTECTION SYSTEMS:
Private sprinkler and fire protection water systems may be connected with the City water mains
subject to the following provisions and regulations and provided the applicant is a consumer
taking water supply for other uses from the City at regular rates for such uses:
A. Application for Service; Approval: Whenever sprinkler or fire protection services are desired,
application shall be made for the privilege of installing such service, which application shall
include complete specifications, adherence to the current CityICC Codes and plans of the
installation contemplated. If said application is approved by the City Council, the applicant shall
enter into an agreement with the City for connection to City mains, subject to the provisions of
this Chapter. (Ord. 1974-69, 10-24-74)
B. Inspection of System:
1. City water will be turned into any sprinkler or fire protection system only when such
installation shall have been subjected to and passed such inspection and pressure tests as may be
required by the Superintendent Director of Public Works. All pipes in connection with such
system shall be left exposed until such tests have been made and the system approved. No cross-
connections between private water supplies and services connected to City mains shall be
permitted.
2. Any and all premises connected to City water mains for sprinkler or fire protection services
shall be subject to inspection by the Superintendent Director of Public Works at any time for
count and conformity to the City regulations.
C. Rates and Charges: Rates and charges shall be as provided in Section 7-5-5-1 of this Chapter.
(Ord. 1974-69, 10-24-74; 1994 Code)
7-5-13: WATER CUSTOMER CONTRACTUAL AGREEMENT:
The rules and regulations as set forth in this chapter shall be considered a part of the contract of
every person who takes water supplied by the City through the City Waterworks. Every such
person who takes water shall be considered as having expressly agreed to be bound by the
provisions of this chapter upon his acceptance of water service from the City. (Ord. 1974-69, 10-
24-1974)
7-5-14: VIOLATION AND PENALTY:
(Rep. by Ord. 2008-74, 8-26-2008)
7-5-15: WATER CONSERVATION REGULATIONS:
A. Definitions: The following words and phrases when used in this section shall, for the purpose
of this section, have the following meanings:
CITY: The United City of Yorkville.
DRIP IRRIGATION SYSTEM: A soaking hose that when in use does not result in an actual
dissipation of water.
DRIP LINE: Pertaining to a tree or shrub, the ground area immediately beneath the branches
of the tree or shrub.
LANDSCAPE/LANDSCAPING: Sod and seeded turf lawns, gardens, trees, shrubs, and other
living plants.
PERMITTED HOURS OF WATER USE: A time period between five o'clock (5:00) A.M.
and nine o'clock (9:00) A.M., and between nine o'clock (9:00) P.M. and twelve o'clock
(12:00) midnight, each day.
PERSON: Any individual, firm, partnership, association, corporation, company, organization,
or entity of any kind.
WATER: The water provided by and obtained by a person from the City water supply and
distribution system.
B. Application:
1. The provisions of this section shall apply to all persons using water, and to all properties
within the City or unincorporated areas which are connected to the City's water supply and
distribution system, regardless of whether any person using the water has a contract for
service with the City.
2. The provisions of this section shall apply annually from May 1 through September 30,
subject to any modifications thereof, including application of these or other regulations
during this or any other time, by an emergency proclamation issued pursuant to subsection
C of this section.
C. Restricted Hours And Days For Specified Uses:
1. Water may be used for landscape watering or the filling of swimming pools only as
follows:
a. All properties with even numbered street numbers (i.e., numbers ending in 0, 2, 4, 6
or 8) may use water for landscape watering or for pool filling, only on even numbered
calendar dates during permitted hours of water use.
c. All properties with odd numbered street numbers (i.e., numbers ending in 1, 3, 5, 7,
and 9) may use water for landscape watering or for pool filling only on odd
numbered calendar dates during permitted hours of water use.
d. There shall be no restrictions as to hours or days when water may be used for any of
the following:
(1) Landscape watering or sprinkling where such watering or sprinkling is done
by a person using a handheld watering device;
(2) Filling swimming pools with a volume of fifty (50) gallons or less;
(3) The automatic watering of trees and shrubs by means of automatic root feed
or drip irrigation systems within the drip line of the tree or shrub; or
(4) Vehicle and equipment washing; or
(5) Any other lawful use of water such as bathing, clothes washing, and other
normal household uses not otherwise specifically restricted by the provisions of
this section.
D. Restrictions For Sod Laying And Lawn Seeding For New Lawns: Notwithstanding the
provisions of subsection C of this section, the following special regulations shall apply:
1. Sod laying, lawn seeding, and the planting of other landscaping for the establishment of
a new lawn or new landscaping is prohibited from July 1 through August 31 each year
unless the source of watering for said sod, lawn seeding and/or planting of landscaping is
derived from a private well, imported water source or means other than any municipal
water source.
2. From May 1 through June 30 and from September 1 through September 30, water may
be used on new lawns (sod or seed), only as follows:
a. Priora. Prior to sod laying or lawn seeding, a sod watering permit, attached as
exhibit A to the ordinance codified herein, must be shall be obtained from the Director
of Public WorksUnited City of Yorkville.
b. On the day new sod or seed has been placed on a property, a person may use an
automatic sprinkling device to apply water to the sod or seed for a total period of time
not to exceed eight (8) hours.
c. For the next nine (9) days thereafter, a person may apply water to said sod or seed
each day during permitted hours of water use.
d. Following the first ten (10) days after the sod or seed is placed, the provisions of
subsection C of this section shall apply.
3. Prior to the execution of any real estate contract for the sale of newly constructed
property, the builder or owner of such new construction shall:
a. Inform prospective purchasers of the restrictions upon the installation of new lawns
set forth in this section;
b. Attach a copy of these regulations to the contract; and
d. Obtain the signature of the purchaser(s) on a statement that he/she or they has /have
been informed of the new lawn installation restrictions set forth in this section.
4. The applicant for a certificate of occupancy for any newly constructed property shall
submit as a part of his application, and as a condition of issuance of such certificate, a copy
of said signed statement. When an application for certificate of occupancy is submitted
prior to sale of the property, and the future occupant is unknown, the applicant shall submit
his signed statement that he shall comply with the requirements of this section at the time
the real estate contract is executed.
E. Waste Of Water Prohibited: No person shall allow a continuous stream of water to run off into
any gutter, ditch, drain, or street inlet while using water for restricted purposes during the
permitted hours of water use.
F. Exceptions: The provisions of this section shall not apply to any commercial or industrial
entity for which use of water is necessary to continue normal business operations, or to
maintain stock or inventory. Provided, however, this exception shall not apply to any and all
uses of water not essential to normal business operations or maintenance of inventory or
stock, and specifically shall not apply to landscape watering or pool filling.
G. Bulk Water Rates: Bulk water rates shall be increased to three (3) times the nonresident water
rate during the time described in subsection B of this section.
H. Hydrant Use Prohibited: Hydrants connected to the City water supply and distribution system
for the purpose of providing water for firefighting purposes shall not be opened by any
person, other than authorized City or Fire District personnel, except for the purpose of
fighting a fire.
I. Emergency Proclamation:
1. Whenever the water supply of the City is diminished from any cause, including, but not
limited to, prolonged dry period, increased water demand, equipment failure, or water
quality concerns, to an amount which in the opinion of the City Engineer or Director of
Public Works is or is likely to become dangerous to the health and safety of the public,
the City Mayor is hereby authorized and empowered to issue an emergency
proclamation specifying different or additional regulations on the use of water.
2. Such regulations may provide for limitations on the usage of water, limitations on days
and hours of use of water for some or all purposes, and the prohibition of specified uses
of water.
3. Upon issuing such proclamation, the City Mayor shall make the contents thereof known
to the public by posting a copy at the City Hall, and by news release to local
newspapers and radio media, and may also endeavor to notify the City residents and
other persons in any other practical manner that he or she shall devise. Further, the City
Mayor shall immediately deliver notice of such proclamation, and the regulations that
have been imposed by such proclamation, to all members of the City Council.
4. The emergency proclamation of the City Mayor, and the regulations imposed thereby,
shall remain in full force and effect until any one of the following shall first occur:
a. The City Mayor determines that the emergency no longer exists and that the
emergency proclamation, and the regulations imposed thereby, shall no longer continue
in effect.
b. The City Council modifies or repeals the emergency proclamation, and the
regulations imposed thereby, by means of an ordinance enacted at any regular or
special meeting of the City Council.
c. The first regular meeting of the City Council occurring more than thirty (30) days
after the date of the emergency proclamation of the City Mayor.
5. Any City employee or officer may, at the direction of the City Mayor, notify and warn
any person of the effect of said emergency proclamation and direct said person to
comply with said watering or sprinkling restrictions. If any said person, after having
first been warned about said restrictions of the emergency proclamation, fails to comply
with the water restrictions, the person shall be deemed to be in violation of this section.
(Ord. 2004-17, 3-23-2004)
J. Restriction On Permanent Landscape Watering Systems Of Nonresidential Properties:
1. This subsection J shall apply only to nonresidential properties, and common and/or open
space areas of residential developments.
2. For this subsection J, a "permanent landscape watering system" shall be defined as any
system of pipes, sprinkler heads or similar devices installed underground to be used to
provide landscape watering.
3. Landscape watering upon nonresidential properties shall be limited as follows:
a. For properties with one building, a total area within the property not to exceed one
acre may be watered by a permanent landscape watering system using the City's
potable water. This area shall be measured by the amount of nonimpervious surface on
the property including all landscaped areas, lawn areas and green space regardless of
the size of the area initially planned to be irrigated.
b. For properties with more than one building, a total area within the property not to
exceed three (3) acres may be watered by a permanent landscape watering system using
the City's potable water. This area shall be measured by the amount of nonimpervious
surface on the property including all landscaped areas, lawn areas and green space
regardless of the size of the area initially planned to be irrigated.
c. For the common space and/or open space of a primarily residential development, no
permanent landscape watering system shall be allowed using the City's potable water.
d. All permanent landscape watering systems permitted to use the City's potable
water shall be metered the same as domestic water service. No special meters will be
permitted.
4. The total area to be watered shall be measured as the area within reach of any
permanent device used to water landscape including, but not limited to, sprinkler heads,
hoses, trenches or similar devices to water landscape. (Ord. 2006-123, 10-24-2006)
7-5-16: INSPECTION; AUDIT; APPEAL:
A. Right Of Access; Use Inspection: The United City of Yorkville and its employees and the
Illinois environmental protection agency shall have ready access at all reasonable times to the
premises, places or buildings where water service is supplied for the purpose of inspecting,
examining and testing the consumption, use and flow of water, and it shall be unlawful for
any person to interfere with, prevent or obstruct the United City of Yorkville or its duly
authorized agent or the Illinois environmental protection agency in its duties hereunder. Every
user of the system shall take the same upon the conditions prescribed in this section.
B. Powers And Authority Of Inspectors:
1. The Director of Public Works and other duly authorized employees of the United City of
Yorkville and the Illinois Environmental Protection Agency, bearing proper credentials and
identification shall be permitted to enter all properties for the purposes of inspection,
observation, measurement, sampling, and testing in accordance with the provisions of this
section. The United City of Yorkville or its representative shall have no authority to inquire
into any processes, including metallurgical, chemical, oil refining, ceramic, paper, or other
industries beyond that point having a direct bearing on the kind and source of discharge to
the sewers or waterway or facilities for waste treatment.
2. While performing the necessary work on private properties referred to above the director
of public works or duly authorized employees of the United City of Yorkville and the
Illinois environmental protection agency shall observe all safety rules applicable to the
premises established by the property owner or its agent, and the property owner or its agent
shall be held harmless for injury or death to the United City of Yorkville employees, and
the United City of Yorkville shall indemnify the company against liability claims and
demands for personal injury or property damage asserted against the property owner and
growing out of the gauging and sampling operation, except as such may be caused by
negligence or failure of the property owner or its agent to maintain conditions as required
in this chapter.
3. The Director of Public Works and other duly authorized employees of the United City of
Yorkville bearing proper credentials and identification shall be permitted to enter all
private properties through which the United City of Yorkville holds a duly negotiated
easement for the purposes of, but not limited to, inspection, observation, measurement,
sampling, repair, and maintenance of any portion of the waterworks lying within said
easement. All entry and subsequent work, if any, on said easement, shall be done in full
accordance with the terms of the duly negotiated easement pertaining to the private
property involved.
C. Access To Records: The IEPA or its authorized representative shall have access to any books,
documents, papers and records of the United City of Yorkville, which are applicable to the
water system, of user charges for the purpose of making audit, examination, excerpts and
transcriptions thereof to ensure compliance with the terms of any loan obtained from the IEPA
under its Public Water Supply (PWS) loan program.
D. Annual Review Of Charges: The adequacy of the water service charge shall be reviewed, not
less often than annually, by certified public accountants for the United City of Yorkville in
their annual audit report. The water service charge shall be revised periodically to reflect a
change in the local capital costs or overhead, maintenance and repair costs.
E. Appeals: Users shall be provided the method for computing rates and service charges within
fourteen (14) days of written request. City shall make best efforts to remedy any disagreement
with the method used or the computations made within thirty (30) days of a formal written
appeal outlining the discrepancies. (Ord. 2005-19, 3-8-2005)
Have a question or comment about this agenda item?
Call us Monday-Friday, 8:00am to 4:30pm at 630-553-4350, email us at agendas@yorkville.il.us, post at www.facebook.com/CityofYorkville,
tweet us at @CityofYorkville, and/or contact any of your elected officials at http://www.yorkville.il.us/320/City-Council
Agenda Item Summary Memo
Title:
Meeting and Date:
Synopsis:
Council Action Previously Taken:
Date of Action: Action Taken:
Item Number:
Type of Vote Required:
Council Action Requested:
Submitted by:
Agenda Item Notes:
Reviewed By:
Legal
Finance
Engineer
City Administrator
Human Resources
Community Development
Police
Public Works
Parks and Recreation
Agenda Item Number
New Business #7
Tracking Number
PW 2017-64
Overview of Downtown Brownfields
Public Works Committee – September 19, 2017
N/A
N/A
Discussion
Review of brownfield study and process for downtown/east alley properties.
Bart Olson Administration
Name Department
Responsive ■Resourceful ■Reliable 1
Site Summary
City of Yorkville
Former Grainco FS, Kendall County Farm Bureau, and City Parking Lot
I.Site Introduction and History
§The site is comprised of three contiguous parcels consisting of a municipal parking
lot owned by the City, a parcel owned by the Kendall County Farm Bureau and a
former service station and farm supply depot historically owned by Grainco FS
§Prior Investigation conducted:
o 2003 by Terracon
§ Phase I Environmental Site Assessment – Kendall Grundy FS, Inc.
§ Phase II Environmental Site Assessment – Kendall Grundy FS, Inc.
o 2005 by Civil & Environmental Consultants, Inc. (CEC)
§ Phase I Environmental Site Assessment
§ Comprehensive Site Investigation
o 2012-2013 by Terracon
§ Phase I Environmental Site Assessment
§ Site Investigation Update
§Recognized Environmental Conditions (Terracon 2012)
o The historical heating oil UST on the east side of the Kendall County Farm
Bureau building
o The suspect UST fill pipe on the north side of the office/warehouse building
o The historical operation of gasoline UST system on the east side of the
historical automobile fuel and service station on the Grainco FS portion of
the site
o The suspect oil/water separator located inside the historical automobile
service station
o Prior Phase I ESA, Limited Site Investigation, and Comprehensive Site
Investigation reports identified RECs and confirmed soil and groundwater
impacts on-site above the Illinois Environmental Protection Agency (IEPA)
Site Remediation Program (SRP) default remediation objectives
II. Summary of Historical Investigation Results
Site Subsurface Conditions
§Approximately 5-10 feet of soil overlying bedrock
§Groundwater depth of approximately 4-10 feet below ground surface
§Groundwater flow through bedrock
United City of Yorkville – Site Summary
September 12, 2017 ■Terracon Project 11127052
Responsive ■Resourceful ■Reliable 2
Soil
§Petroleum indicator contaminants above the Illinois Environmental Protection
Agency (IEPA) Residential Tier 1 Remediation Objectives (ROs) at the former
fueling station on former Grainco property (BTEX, PNAs)
§Lead above the Tier 1 RO in the City parking lot
Groundwater
§Metals (arsenic, iron, manganese) above the Class I ROs
Regulatory Status
§Site is actively enrolled in voluntary IEPA Site Remediation Program (enrolled in 2005)
§Comprehensive Site Investigation Report (CEC 2007) approved by IEPA
§Site Investigation Work Plan (Terracon 2012) approved by IEPA
III. Moving Forward to No Further Remediation Letter
§New IEPA regulations regarding indoor inhalation (Vapor Intrusion) will need to be
evaluated at the site
§Update site soil and groundwater conditions may be warranted based on IEPA’s
input
§Develop Remediation Objectives and Remedial Action Plan incorporating property
owner’s development plans as appropriate
Project Status
Former Grainco FS,
Kendall County Farm
Bureau, and
City Parking Lot
Illinois Route 47 and East Van Emmon St
Yorkville, IL
Site Location
Historical Site Diagram
Cross Section Location
From CEC (2005)
Soil Boring Results
Extent of Soil Impacts
Extent of Ingestion/Inhalation Impacts
Have a question or comment about this agenda item?
Call us Monday-Friday, 8:00am to 4:30pm at 630-553-4350, email us at agendas@yorkville.il.us, post at www.facebook.com/CityofYorkville,
tweet us at @CityofYorkville, and/or contact any of your elected officials at http://www.yorkville.il.us/320/City-Council
Agenda Item Summary Memo
Title:
Meeting and Date:
Synopsis:
Council Action Previously Taken:
Date of Action: Action Taken:
Item Number:
Type of Vote Required:
Council Action Requested:
Submitted by:
Agenda Item Notes:
Reviewed By:
Legal
Finance
Engineer
City Administrator
Human Resources
Community Development
Police
Public Works
Parks and Recreation
Agenda Item Number
New Business #8
Tracking Number
ADM 2017-70
Building Condition Reports 2017
Public Works Committee - September 19, 2017
N/A
N/A
N/A
Discussion of the Preliminary Reports from the Building Condition Survey that
EMG performed on City-owned structures and facilities.
Erin Willrett Administration
Name Department
Summary
Discussion of the Preliminary Reports from the Building Condition Survey that EMG performed
on City-owned structures and facilities.
Background
The City went out for qualifications on November 2, 2016. The City contracted with EMG on
March 28, 2017. The project was kicked-off on May 10, 2017 and the field work took place during May
15 – June 8th. Three structures were added to the study after the original contract had been approved.
Those structures are 102 E. Van Emmon, 609 N. Bridge Street and Prestwick Lift Station.
EMG’s reports include an assessment of all City-owned buildings, structures and parking
facilities (structural frame and building envelope, curtain wall, roofing, plumbing, heating, air
conditioning and ventilation, electrical, vertical transportation, life safety/fire protection, interior
elements, code inquiries, ADA, and mold). An equipment inventory was also completed. Bar-coding of
the equipment and start-up with facility dude, which is an online portal that will hold the database
information, will not be initiated until the reports are finalized.
The preliminary Building Conditions Reports are attached for your review. Also attached are 3
spreadsheets breaking down the reports. One is an overall list of structures/facilities reviewed. The
second is the structures/facilities reviewed ranked by an immediate repair Facilities Condition Index
(FCI) rating from very poor to good. The third is a breakdown of structure/facilities reviewed ranked by
a 10 year FCI rating, this is the ratio of anticipated capital reserve needs over the next ten years to the
current replacement value. One of the major goals of the reports was to calculate the FCI, which gives
an indication of a building’s overall condition. There are a few outstanding items that still need to be
addressed between the consultant and the written reports. Staff expects minor updates to the reports to
be forthcoming.
Recommendation
There is no formal staff recommendation during this time of review. Please read the documents
provided and let staff know if you have any questions.
Memorandum
To: Public Works Committee
From: Erin Willrett, Assistant City Administrator
CC: Bart Olson, City Administrator
Date: September 14, 2017
Subject: EMG Building Condition Reports 2017
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
New City Hall
102 East Van Emmon Street
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-001.322 June 13, 2017 May 16, 2017
FACILITY CONDITION ASSESSMENT
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1. Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
1.3. Special Issues and Follow-Up Recommendations ...................................................................... 3
1.4. Opinions of Probable Cost .......................................................................................................... 3
1.4.1. Methodology ................................................................................................................................ 4
1.4.2. Immediate Repairs ...................................................................................................................... 4
1.4.3. Replacement Reserves ............................................................................................................... 4
2. Purpose and Scope .............................................................................................................................. 5
2.1. Purpose ....................................................................................................................................... 5
2.2. Scope .......................................................................................................................................... 6
2.3. Personnel Interviewed ................................................................................................................. 6
2.4. Documentation Reviewed ........................................................................................................... 7
2.5. Pre-Survey Questionnaire ........................................................................................................... 7
2.6. Weather Conditions ..................................................................................................................... 7
3. Accessibility and Property Research ................................................................................................. 8
3.1. ADA Accessibility ........................................................................................................................ 8
4. Existing Building Assessment ............................................................................................................ 9
4.1. Unit or Space Types .................................................................................................................... 9
4.2. Inaccessible Areas or Key Spaces Not Observed ...................................................................... 9
5. Site Improvements ............................................................................................................................. 10
5.1. Utilities ....................................................................................................................................... 10
5.2. Parking, Paving, and Sidewalks ................................................................................................ 10
5.3. Drainage Systems and Erosion Control .................................................................................... 11
5.4. Topography and Landscaping ................................................................................................... 12
5.5. General Site Improvements ....................................................................................................... 13
6. Building Architectural and Structural Systems ............................................................................... 15
6.1. Foundations ............................................................................................................................... 15
6.2. Superstructure ........................................................................................................................... 15
6.3. Roofing ...................................................................................................................................... 16
6.4. Exterior Walls ............................................................................................................................ 17
6.5. Exterior and Interior Stairs ......................................................................................................... 17
6.6. Exterior Windows and Doors ..................................................................................................... 18
6.7. Patio, Terrace, and Balcony ...................................................................................................... 18
7. Building Mechanical and Plumbing Systems .................................................................................. 19
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC) ..................................................... 19
7.2. Building Plumbing and Domestic Hot Water ............................................................................. 21
7.3. Building Gas Distribution ........................................................................................................... 22
7.4. Building Electrical ...................................................................................................................... 22
7.5. Building Elevators and Conveying Systems .............................................................................. 23
7.6. Fire Protection and Security Systems ....................................................................................... 24
8. Interior Spaces .................................................................................................................................... 25
8.1. Interior Finishes ......................................................................................................................... 25
9. Other Structures ................................................................................................................................. 27
10. Certification ......................................................................................................................................... 28
11. Appendices ......................................................................................................................................... 29
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
1
www.EMGcorp.com p 800.733.0660
1. Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 102 East Van Emmon Street, Yorkville, Illinois 60560
Year Constructed/Renovated:
Originally constructed 1930s
Addition 2002
Partially renovated 2012 to 2014
Current Occupants: None
Percent Utilization: 0%
Management Point of Contact: Mr. Peter Ratos, Building Code Official, City of Yorkville
630.553.8574 phone
Property Type: Municipal
Site Area: 3.43 acres
Building Area: 14,000 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of
Spaces: 41 spaces in open lots
Building Construction: Masonry bearing walls and metal-framed roofs.
Roof Construction: Flat roofs with built-up membrane.
Exterior Finishes: Brick Veneer
Heating, Ventilation and Air
Conditioning:
Central system with boilers, air handlers, and split system units.
Individual package unit.
Fire and Life/Safety:
Fire sprinklers, hydrants, smoke detectors, alarms, strobes,
extinguishers, pull stations, alarm panel, exit signs, and backup light
fixtures.
Dates of Visit: 5/16/2017
On-Site Point of Contact (POC): Peter Ratos
Assessment and Report
Prepared by: Kevin Koranda
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair to Poor HVAC Fair
Structure Fair Plumbing Fair
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
2
www.EMGcorp.com p 800.733.0660
Systemic Condition Summary
Roof Fair to Poor Electrical Fair
Vertical Envelope Fair Elevators Fair
Interiors Poor Fire Fair
The following bullet points highlight the most significant short term and modernization recommendations:
Replace asphalt parking area
Replace site lighting fixtures
Renovate interior spaces
Upgrade building automation system
Upgrade lighting system
Replace main switchgear
Replace air handlers
Upgrade sump pumps and perimeter drainage tile
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained in recent years and is in fair overall condition.
According to property management personnel, the property has had an active capital improvement expenditure program over the past
three years. Capital expenditures include, but are not limited to: roof membrane replacement. The building was newly purchased and
the scope of renovations that occurred within the last three years was not clear. Supporting documentation was not provided in support
of these claims but some of the work is evident.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
3
www.EMGcorp.com p 800.733.0660
Fci Condition
Rating Definition Percentage
Value
Good In new or well-maintained condition, with no visual evidence
of wear, soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and
functioning condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its
useful or serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal
is now necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 115% VERY POOR
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 49.1% Poor
Current Replacement Value (CRV) 14,000 SF * 78.57 / SF = $1,100,000
Year 0 (Current Year) - Immediate Repairs (IR) $1,268,442
Years 1-10 – Replacement Reserves (RR) $540,971
Total Capital Needs $1,809,413
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Replace asphalt parking area
Replace site lighting fixtures
Renovate interior spaces
Upgrade building automation system
Upgrade lighting system
Replace main switchgear
Replace air handlers
Upgrade sump pumps and perimeter drainage tile
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
1.3. Special Issues and Follow-Up Recommendations
As part of the FCA, a limited assessment of accessible areas of the building(s) was performed to determine the presence of fungal
growth, conditions conducive to fungal growth, and/or evidence of moisture. Property personnel were interviewed concerning any
known or suspected fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Sampling is not a part of this
assessment.
There are no visual indications of the presence of fungal growth, conditions conducive to fungal growth, or evidence of moisture in
representative readily accessible areas of the property.
1.4. Opinions of Probable Cost
Cost estimates are attached at the front of this report (following the cover page).
These estimates are based on Invoice or Bid Document/s provided either by the Owner/facility and construction costs developed by
construction resources such as R.S. Means and Marshall & Swift, EMG’s experience with past costs for similar properties, city cost
indexes, and assumptions regarding future economic conditions.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
4
www.EMGcorp.com p 800.733.0660
Opinions of probable costs should only be construed as preliminary, order of magnitude budgets. Actual costs most probably will vary
from the consultant’s opinions of probable costs depending on such matters as type and design of suggested remedy, quality of
materials and installation, manufacturer and type of equipment or system selected, field conditions, whether a physical deficiency is
repaired or replaced in whole, phasing of the work (if applicable), quality of contractor, quality of project management exercised, market
conditions, and whether competitive pricing is solicited, etc. ASTM E2018-08 recognizes that certain opinions of probable costs cannot
be developed within the scope of this guide without further study. Opinions of probable cost for further study should be included in the
FCA.
1.4.1. Methodology
Based upon site observations, research, and judgment, along with referencing Expected Useful Life (EUL) tables from various industry
sources, EMG opines as to when a system or component will most probably necessitate replacement. Accurate historical replacement
records, if provided, are typically the best source of information. Exposure to the elements, initial quality and installation, extent of use,
the quality and amount of preventive maintenance exercised, etc., are all factors that impact the effective age of a system or
component. As a result, a system or component may have an effective age that is greater or less than its actual chronological age.
The Remaining Useful Life (RUL) of a component or system equals the EUL less its effective age. Projections of Remaining Useful Life
(RUL) are based on continued use of the Property similar to the reported past use. Significant changes in occupants and/or usage may
affect the service life of some systems or components.
Where quantities could not be derived from an actual take-off, lump sum costs or allowances are used. Estimated costs are based on
professional judgment and the probable or actual extent of the observed defect, inclusive of the cost to design, procure, construct and
manage the corrections.
1.4.2. Immediate Repairs
Immediate repairs are opinions of probable costs that require immediate action as a result of: (1) material existing or potential unsafe
conditions, (2) material building or fire code violations, or (3) conditions that, if not addressed, have the potential to result in, or
contribute to, critical element or system failure within one year or will most probably result in a significant escalation of its remedial cost.
1.4.3. Replacement Reserves
Replacement Reserves are for recurring probable expenditures, which are not classified as operation or maintenance expenses. The
replacement reserves should be budgeted for in advance on an annual basis. Replacement Reserves are reasonably predictable both
in terms of frequency and cost. However, Replacement Reserves may also include components or systems that have an
indeterminable life but, nonetheless, have a potential for failure within an estimated time period.
Replacement Reserves exclude systems or components that are estimated to expire after the reserve term and are not considered
material to the structural and mechanical integrity of the subject property. Furthermore, systems and components that are not deemed
to have a material effect on the use of the Property are also excluded. Costs that are caused by acts of God, accidents, or other
occurrences that are typically covered by insurance, rather than reserved for, are also excluded.
Replacement costs are solicited from ownership/property management, EMG’s discussions with service companies, manufacturers'
representatives, and previous experience in preparing such schedules for other similar facilities. Costs for work performed by the
ownership’s or property management’s maintenance staff are also considered.
EMG’s reserve methodology involves identification and quantification of those systems or components requiring capital reserve funds
within the assessment period. The assessment period is defined as the effective age plus the reserve term. Additional information
concerning system’s or component’s respective replacement costs (in today's dollars), typical expected useful lives, and remaining
useful lives were estimated so that a funding schedule could be prepared. The Replacement Reserves Schedule presupposes that all
required remedial work has been performed or that monies for remediation have been budgeted for items defined in the Immediate
Repair Cost Estimate.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
5
www.EMGcorp.com p 800.733.0660
2. Purpose and Scope
2.1. Purpose
EMG was retained by the client to render an opinion as to the Property’s current general physical condition on the day of the site visit.
Based on the observations, interviews and document review outlined below, this report identifies significant deferred maintenance
issues, existing deficiencies, and material code violations of record at municipal offices, which affect the Property’s use. Opinions are
rendered as to its structural integrity, building system condition and the Property’s overall condition. The report also notes building
systems or components that have realized or exceeded their typical expected useful lives.
CONDITIONS:
The physical condition of building systems and related components are typically defined as being in one of five conditions: Excellent,
Good, Fair, Poor, Failed or a combination thereof. For the purposes of this report, the following definitions are used:
Excellent = New or very close to new; component or system typically has been installed within the past year, sound and
performing its function. Eventual repair or replacement will be required when the component or system either
reaches the end of its useful life or fails in service.
Good = Satisfactory as-is. Component or system is sound and performing its function, typically within the first third of its
lifecycle. However, it may show minor signs of normal wear and tear. Repair or replacement will be required
when the component or system either reaches the end of its useful life or fails in service.
Fair = Showing signs of wear and use but still satisfactory as-is, typically near the median of its estimated useful life.
Component or system is performing adequately at this time but may exhibit some signs of wear, deferred
maintenance, or evidence of previous repairs. Repair or replacement will be required due to the component or
system’s condition and/or its estimated remaining useful life.
Poor = Component or system is significantly aged, flawed, functioning intermittently or unreliably; displays obvious
signs of deferred maintenance; shows evidence of previous repair or workmanship not in compliance with
commonly accepted standards; has become obsolete; or exhibits an inherent deficiency. The present condition
could contribute to or cause the deterioration of contiguous elements or systems. Either full component
replacement is needed or repairs are required to restore to good condition, prevent premature failure, and/or
prolong useful life.
Failed
= Component or system has ceased functioning or performing as intended. Replacement, repair, or other
significant corrective action is recommended or required.
Not Applicable
= Assigning a condition does not apply or make logical sense, most commonly due to the item in question not
being present.
FORMAT OF THE BODY OF THE REPORT:
Throughout sections 5 through 9 of this report, each report section will typically contain three subsections organized in the following
sequence:
A descriptive table (and/or narrative), which identifies the components assessed, their condition, and other key data points.
A simple bulleted list of Anticipated Lifecycle Replacements, which lists components and assets typically in Excellent, Good, or Fair
condition at the time of the assessment but that will require replacement or some other attention once aged past their estimated
useful life. These listed components are typically included in the associated inventory database with costs identified and budgeted
beyond the first several years.
A bulleted cluster of Actions/Comments, which include more detailed narratives describing deficiencies, recommended repairs, and
short term replacements. The assets and components associated with these bullets are/were typically problematic and in Poor or
Failed condition at the time of the assessment, with corresponding costs included within the first few years.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
6
www.EMGcorp.com p 800.733.0660
PLAN TYPES:
Each line item in the cost database is assigned a Plan Type, which is the primary reason or rationale for the recommended
replacement, repair, or other corrective action. This is the “why” part of the equation. A cost or line item may commonly have more
than one applicable Plan Type; however, only one Plan Type will be assigned based on the “best” fit, typically the one with the greatest
significance. The following Plan Types are listed in general weighted order of importance:
Safety = An observed or reported unsafe condition that if left unaddressed could result in an injury; a system
or component that presents a potential liability risk.
Performance/Integrity = Component or system has failed, is almost failing, performs unreliably, does not perform as
intended, and/or poses a risk to overall system stability.
Accessibility = Does not meet ADA, UFAS, and/or other handicap accessibility requirements.
Environmental = Improvements to air or water quality, including removal of hazardous materials from the building or
site.
Modernization/Adaptation
= Conditions, systems, or spaces that need to be upgraded in appearance or function to meet current
standards, facility usage, or client/occupant needs.
Lifecycle/Renewal
= Any component or system in which future repair or replacement is anticipated beyond the next
several years and/or is of minimal substantial early-term consequence.
2.2. Scope
The standard scope of the Facility Condition Assessment includes the following:
Visit the Property to evaluate the general condition of the building and site improvements, review available construction documents in
order to familiarize ourselves with, and be able to comment on, the in-place construction systems, life safety, mechanical, electrical,
and plumbing systems, and the general built environment.
Identify those components that are exhibiting deferred maintenance issues and provide cost estimates for Immediate Costs and
Replacement Reserves based on observed conditions, maintenance history and industry standard useful life estimates. This will
include the review of documented capital improvements completed within the last five-year period and work currently contracted for, if
applicable.
Provide a full description of the Property with descriptions of in-place systems and commentary on observed conditions.
Provide a general statement of the subject Property’s compliance to Title III of the Americans with Disabilities Act. This will not
constitute a full ADA survey, but will help identify exposure to issues and the need for further review.
Perform a limited assessment of accessible areas of the building(s) for the presence of fungal growth, conditions conducive to fungal
growth, and/or evidence of moisture. EMG will also interview Project personnel regarding the presence of any known or suspected
fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Potentially affected areas will be photographed.
Sampling will not be considered in routine assessments.
List the current utility service providers.
Review maintenance records and procedures with the in-place maintenance personnel.
Observe a representative sample of the interior spaces/units, including vacant spaces/units, in order to gain a clear understanding of
the property’s overall condition. Other areas to be observed include the exterior of the property, the roofs, interior common areas,
and the significant mechanical, electrical and elevator equipment rooms.
Provide recommendations for additional studies, if required, with related budgetary information.
Provide an Executive Summary at the beginning of this report.
Prepare a mechanical equipment inventory list.
2.3. Personnel Interviewed
The management staff was interviewed for specific information relating to the physical property, available maintenance procedures,
historical performance of key building systems and components, available drawings and other documentation. The following personnel
from the facility and government agencies were interviewed in the process of conducting the FCA:
Name and Title Organization Phone Number
Peter Ratos
Building Code Official City of Yorkville 630.553.8574
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
7
www.EMGcorp.com p 800.733.0660
The FCA was performed with the assistance of Peter Ratos, Building Code Official, City of Yorkville, the onsite Point of Contact (POC),
who was cooperative and provided information that appeared to be accurate based upon subsequent site observations. The onsite
contact is completely knowledgeable about the subject property and answered most questions posed during the interview process. The
property has only been owned by the city for a very short period of time and the POC was relatively unfamiliar with the facility.
2.4. Documentation Reviewed
Prior to the FCA, relevant documentation was requested that could aid in the knowledge of the subject property’s physical
improvements, extent and type of use, and/or assist in identifying material discrepancies between reported information and observed
conditions. The review of submitted documents does not include comment on the accuracy of such documents or their preparation,
methodology, or protocol. The Documentation Request Form is provided in Appendix E.
2.5. Pre-Survey Questionnaire
A Pre-Survey Questionnaire was sent to the POC prior to the site visit. The questionnaire is included in Appendix E. Information
obtained from the questionnaire has been used in preparation of this report.
2.6. Weather Conditions
5/16/17: Clear, with temperatures in the 60s (°F) and light winds.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
8
www.EMGcorp.com p 800.733.0660
3. Accessibility and Property Research
3.1. ADA Accessibility
Generally, Title III of the Americans with Disabilities Act (ADA) prohibits discrimination by entities to access and use of “areas of public
accommodations” and “commercial facilities” on the basis of disability. Regardless of its age, these areas and facilities must be
maintained and operated to comply with the Americans with Disabilities Act Accessibility Guidelines (ADAAG).
Buildings completed and occupied after January 26, 1992 are required to comply fully with the ADAAG. Existing facilities constructed
prior to this date are held to the lesser standard of compliance to the extent allowed by structural feasibility and the financial resources
available. As an alternative, a reasonable accommodation pertaining to the deficiency must be made.
During the FCA, a limited visual observation for ADA accessibility compliance was conducted. The scope of the visual observation was
limited to those areas set forth in EMG’s Abbreviated Accessibility Checklist provided in Appendix D of this report. It is understood by
the Client that the limited observations described herein does not comprise a full ADA Compliance Survey, and that such a survey is
beyond the scope of EMG’s undertaking. Only a representative sample of areas was observed and, other than as shown on the
Abbreviated Accessibility Checklist, actual measurements were not taken to verify compliance.
The facility does not appear to be accessible with Title III of the Americans with Disabilities Act. Elements as defined by the ADAAG
that are not accessible as stated within the priorities of Title III, are as follows:
Parking
Adequate number of designated parking stalls and signage for cars are not provided.
Adequate number of designated parking stalls and signage for vans are not provided.
Signage indicating accessible parking spaces for cars and vans are not provided.
Curb ramps are required from the parking area to the sidewalks providing access to the building.
Paths of Travel
Stair handrails do not extend beyond the top and bottom risers.
Elevators
Raised elevator markings at control panel and hall buttons are not provided in Braille and Standard Alphabet.
Audible signals are not provided at floor level changes or elevator lobbies indicating car arrival.
Restrooms.
Wrap drain pipes below lavatory with insulation; protect against contact with hot, sharp, or abrasive surfaces.
Add pull station alarm in unisex bathroom.
A full ADA Compliance Survey may reveal additional aspects of the property that are not in compliance.
Corrections of these conditions should be addressed from a liability standpoint, but are not necessarily code violations. The Americans
with Disabilities Act Accessibility Guidelines concern civil rights issues as they pertain to the disabled and are not a construction code,
although many local jurisdictions have adopted the Guidelines as such. The cost to address the achievable items noted above is
included in the cost tables.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
9
www.EMGcorp.com p 800.733.0660
4. Existing Building Assessment
4.1. Unit or Space Types
All 14,000 square feet of the building are currently unoccupied but are planned to be renovated to accommodate the City of Yorkville’s
new City Hall. The spaces are mostly vacant. Some leftover finishes from previous occupants, including an office/spa area in the
basement, bank vaults on the Second Floor, and restrooms, are still in place. Other spaces include a combination of mechanical and
other utility spaces.
4.2. Inaccessible Areas or Key Spaces Not Observed
All of the interior spaces were observed in order to gain a clear understanding of the property’s overall condition. Other areas accessed
included the site within the property boundaries, exterior of the property and the roof. Areas of note that were either inaccessible or not
observed for other reasons are listed in the table below:
Key Spaces Not Observed
Room Number Area Access Issues
NA Basement vault Locked bank vault room and no combination
A “down unit” or area is a term used to describe a unit or space that cannot be occupied due to poor conditions such as fire damage,
water damage, missing equipment, damaged floor, wall or ceiling surfaces, or other significant deficiencies. There are no down units or
areas.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
10
www.EMGcorp.com p 800.733.0660
5. Site Improvements
5.1. Utilities
The following table identifies the utility suppliers and the condition and adequacy of the services.
Site Utilities
Utility Supplier Condition and Adequacy
Sanitary sewer City of Yorkville Good and Adequate
Storm sewer City of Yorkville Good and Adequate
Domestic water City of Yorkville Good and Adequate
Electric service Commonwealth Edison Good and Adequate
Natural gas service Nicor Gas Good and Adequate
Actions/Comments:
According to the POC, the utilities provided are adequate for the property. There are no unique, onsite utility systems such as septic
systems, water or waste water treatment plants, or propane gas tanks. An emergency electrical generator is located on the site.
5.2. Parking, Paving, and Sidewalks
Item Description
Main Ingress and Egress East Van Emmon
Access from North
Additional Entrances Briggs Street
Additional Access from West
Paving and Flatwork
Item Material Last Work Done Condition
Entrance Driveway Apron Concrete 2000 Fair
Parking Lot Asphalt 1995 Poor
Drive Aisles Asphalt 1995 Poor
Service Aisles None NA --
Sidewalks Concrete 1995 Fair
Curbs Concrete 1995 Fair
Site Stairs Concrete 1995 Poor
Pedestrian Ramps None NA --
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
11
www.EMGcorp.com p 800.733.0660
Parking Count
Open Lot Carport Private Garage Subterranean
Garage
Freestanding Parking
Structure
41 - - - -
Total Number of ADA Compliant Spaces 1
Number of ADA Compliant Spaces for Vans 0
Total Parking Spaces 41
Parking Ratio (Spaces/Apartments) NA
Method of Obtaining Parking Count Physical count
Exterior Stairs
Location Material Handrails Condition
Northwest corner Concrete stairs Metal Poor
Anticipated Lifecycle Replacements:
Asphalt seal coating
Asphalt pavement
Sidewalks
Site stairs
Actions/Comments:
The asphalt pavement exhibits significant areas of deterioration in the form of alligator cracking, raveling, large depressions, and
displaced pavement surfaces across the entire lot. Much of the lot is in a state of complete failure requiring full-depth replacement.
In order to restore an effective and usable pavement system, the paving must be completely replaced, with the sub-base re-graded
and compacted.
The concrete sidewalks have isolated areas of cracking and spalling concrete sidewalks. These areas occur along the sidewalk
leading to the main entrance at the south side of the facility. The damaged areas of concrete sidewalks will require lifecycle
replacement.
The concrete site stairs at the northeast corner of the facility are in poor condition. The steps are uneven and subsiding. Replacement
of these concrete stairs is recommended.
5.3. Drainage Systems and Erosion Control
Drainage System and Erosion Control
System Exists At Site Condition
Surface Flow ☐ --
Inlets ☒ Fair
Swales ☒ Fair
Detention pond ☐ --
Lagoons ☐ --
Ponds ☐ --
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
12
www.EMGcorp.com p 800.733.0660
Drainage System and Erosion Control
System Exists At Site Condition
Underground Piping ☒ Fair
Pits ☐ --
Municipal System ☒ Fair
Dry Well ☐ --
Anticipated Lifecycle Replacements:
Sump pumps
Actions/Comments:
There is no evidence of storm water runoff from adjacent properties.
The facility is reportedly located atop a natural spring. Water damage is evident in the old area of the basement and is presumably a
result of this spring. The existing sump pumps are undersized and will require replacement with larger units. The excavation of a
larger sump pit and installation of a new larger sump basin will also be required. The approximate cost for this work is included in the
cost for the replacement of the two sump pumps.
Additionally, an upgrade of the perimeter drainage tile system is recommended. A budgetary cost for this work is included in the
report.
5.4. Topography and Landscaping
Item Description
Site Topography Slopes steeply down from the east side of the property to the west property line.
Landscaping
Trees Grass Flower
Beds Planters
Drought
Tolerant
Plants
Decorative
Stone None
☒ ☒ ☒ ☐ ☐ ☐ ☐
Landscaping
Condition Fair
Irrigation
Automatic
Underground Drip Hand Watering None
☐ ☐ ☐ ☒
Irrigation Condition --
Retaining Walls
Type Location Condition
Concrete Adjacent south entrance Fair
Concrete Adjacent northeast entrance Fair
Concrete South perimeter of parking lot Fair
Anticipated Lifecycle Replacements:
No components of significance
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
13
www.EMGcorp.com p 800.733.0660
Actions/Comments:
The topography and adjacent uses do not appear to present conditions detrimental to the property. There are no significant areas of
erosion.
Some erosion-control gravel from the sloped area of the site has fallen down onto the curb and asphalt parking area at the east side
of the site. This stone should be cleared from the parking area and returned to the adjacent slope. The cost for this work is relatively
insignificant and can be accomplished through the city’s routine maintenance program.
5.5. General Site Improvements
Property Signage
Property Signage Building mounted
Street Address Displayed? Yes
Site and Building Lighting
Site Lighting
None Pole Mounted Bollard Lights Ground
Mounted
Parking Lot
Pole Type
☐ ☒ ☐ ☐ ☐
Fair
Building Lighting
None Wall Mounted Recessed Soffit
☐ ☒ ☒
Fair
REFUSE DISPOSAL
Refuse Disposal Individual garbage bins
Dumpster Locations Mounting Enclosure Contracted? Condition
Trash room Concrete
pad None Yes Fair
Other Site Amenities
Description Location Condition
Playground Equipment None -- --
Tennis Courts None -- --
Basketball Court None -- --
Swimming Pool None -- --
Anticipated Lifecycle Replacements:
Exterior lighting
Site lighting
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
14
www.EMGcorp.com p 800.733.0660
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
15
www.EMGcorp.com p 800.733.0660
6. Building Architectural and Structural Systems
6.1. Foundations
Building Foundation
Item Description Condition
Foundation Concrete foundation walls Fair
Basement and Crawl Space None Fair
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
Isolated areas of the foundation systems are exposed, which allows for limited observation. The foundation systems are concealed.
There are no significant signs of settlement, deflection, or movement. The basement walls appear intact and structurally sound.
There is no evidence of movement or water infiltration.
6.2. Superstructure
Building Superstructure
Item Description Condition
Framing / Load-Bearing Walls Masonry walls Fair
Ground Floor Concrete slab Fair
Upper Floor Framing Concrete beams Fair
Upper Floor Decking Concrete, cast-in-place Fair
Roof Framing Open-web steel joists Fair
Roof Decking Metal decking Fair to Poor
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The superstructure is exposed in some locations, which allows for limited observation. There is isolated evidence of structural
damage due to water intrusion in the older section of the basement. This condition appears to affect the concrete floor decking
immediately above the exterior perimeter walls on the west and south side of the basement. The concrete is cracked and
deteriorating and several pieces have cracked and come loose. The affected area is approximately 20 SF. The property is reportedly
situated near a natural spring and this degradation is presumably due to water from this spring. This concrete will require repairs.
Additional repair work will be necessary to divert water from the perimeter of the facility and prevent future damage. This work is
discussed in section 5.3.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
16
www.EMGcorp.com p 800.733.0660
6.3. Roofing
Primary Roof
Type / Geometry Flat Finish Built-up membrane
Maintenance In-house Staff Roof Age 3 Yrs
Flashing Built-up base and Edge flashing Warranties Unknown
Parapet Copings Exposed copings Roof Drains Internal drains
Fascia Metal Panel Insulation Rigid Board
Soffits None Skylights No
Attics None Ponding Yes
Ventilation Source-1 Power Vents Leaks Observed No
Ventilation Source-2 None Roof Condition Good
The primary roof is located over the majority of the building at the newer sections of the facility.
Secondary Roof
Type / Geometry Flat Finish Built-up membrane
Maintenance In-house Staff Roof Age 25 Yrs
Flashing Built-up base and Edge flashing Warranties Unknown
Parapet Copings Exposed copings Roof Drains Internal drains
Fascia Metal Panel Insulation Rigid Board
Soffits None Skylights No
Attics None Ponding Yes
Ventilation Source-1 Power Vents Leaks Observed No
Ventilation Source-2 None Roof Condition Poor
The secondary roof is located at the older portion of the building at the northwest corner of the facility.
Anticipated Lifecycle Replacements:
TPO roof membrane
Modified bituminous roof membrane
Actions/Comments:
The roof finishes were reportedly installed in 2014 and 1992 respectively. Information regarding roof warranties or bonds was not
available. The roofs are maintained by the in-house maintenance staff.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
17
www.EMGcorp.com p 800.733.0660
According to the POC, it is unknown whether there are active roof leaks. Isolated evidence of roof leaks was observed in several
locations. Water damaged ceiling finishes were observed: at the interface between the newer and older sections of the building on
the upper floor, in the room outside of the main vault at the southwest corner of the building, and in the small coat room adjacent to
the narrow stairwell. Additionally, corrosion was observed on the underside of the metal roof decking throughout the upper floor of the
facility. It is unclear whether these roof leaks are still active and they are assumed to have been repaired during the most recent roof
replacement. All active roof leaks must be repaired.
There is no significant evidence of roof deck or insulation deterioration. The roof substrate and insulation should be inspected during
any future roof repair or replacement work.
The field of the older roof has significant areas of cracking, and seam deterioration across the entire roof surface. The roof membrane
requires replacement.
Roof drainage appears to be inadequate. Significant areas of ponding are evident across many areas of the roof, including: the
center of the facility, the lower potion over the bank vault, and the south of the facility near the package unit.
There are ponding stains and a moderate build-up of debris at some of the drain locations. The affected drains must be cleaned and
cleared and debris must be removed from the roof surfaces.
6.4. Exterior Walls
Building Exterior Walls
Type Location Condition
Primary Finish Brick veneer Fair
Secondary Finish None --
Accented with None --
Soffits Not Applicable --
Building sealants (caulking) are located between dissimilar materials, at joints, and around window and door openings.
Anticipated Lifecycle Replacements:
Caulking
Masonry re-pointing
Actions/Comments:
Isolated portions of the mortar joints along the brick veneer are cracked along the East Van Emmon elevation. The damaged mortar
joints must be cleaned and re-pointed.
There are isolated areas of brittle and deteriorated sealant along the west elevation of the facility. The damaged sealant must be
replaced.
6.5. Exterior and Interior Stairs
Building Exterior and Interior Stairs
Type Description Riser Handrail Balusters Condition
Building Exterior Stairs None None None None --
Building Interior Stairs Steel-framed with pre-cast
treads Open Wood Metal Fair
Building Interior Stairs Steel-framed with pre-cast
treads Closed Wood None Fair
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
18
www.EMGcorp.com p 800.733.0660
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended.
6.6. Exterior Windows and Doors
Building Windows
Window Framing Glazing Location Window
Screen Condition
Aluminum framed storefront Double glaze Building exterior ☐ Fair
Building Doors
Main Entrance Doors Door Type Condition
Fully glazed, metal framed Fair
Secondary Entrance Doors None --
Service Doors None --
Overhead Doors Vinyl Fair
Anticipated Lifecycle Replacements:
Storefront glazing
Exterior storefront doors
Overhead doors
Actions/Comments:
The windows display isolated evidence of damaged frames at the center of the east elevation of the building. The damaged window
frames must be repaired.
The glazing system has isolated areas of missing or loose gaskets at the east elevation of the building. Several windows were
observed to have loose thermal glass, with the most notable example being the windows at the southeast corner of the facility. The
damaged or loose gaskets must be replaced.
6.7. Patio, Terrace, and Balcony
Not applicable. There are no patios, terraces, or balconies.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
19
www.EMGcorp.com p 800.733.0660
7. Building Mechanical and Plumbing Systems
See the Mechanical Equipment List in the Appendices for the quantity, manufacturer’s name, model number, capacity and year of
manufacturer of the major mechanical equipment, if available.
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC)
Building Central Heating System
Primary Heating System Type Hot water boilers
Quantity and Capacity of Major Components 1 boiler at 150 MBH
1 boiler at 900 MBH
Total Heating Capacity 1150 MBH
Heating Fuel Natural gas
Location of Major Equipment Mechanical rooms
Space Served by System Entire building
Age Ranges Vary from 1980 to 2002
Boiler Condition Fair
Heat Exchanger Condition --
Distribution System
HVAC Water Distribution System Two-pipe
Heating Water Circulation Pump Size and Quantity 2 pumps at 1/6th HP each
Pump Condition Fair
Air Distribution System Variable volume
Quantity and Capacity of Air Handlers 2 air handlers ranging from 6000 to 15000 CFM each
Location of Air Handlers Mechanical rooms
Large Spaces the Larger Dedicated AHU’s Serve Entire building
Age of Air Handlers All units dated 1976
Air Handler Condition Fair
Terminal Units None
Quantity and Capacity of Terminal Units One hydronic radiator
Location of Terminal Units Basement storage room
Spaces Served by Terminal Units Storage room
Terminal Unit Condition Fair
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
20
www.EMGcorp.com p 800.733.0660
Supplemental Components
Supplemental Component #1 Package unit
Location / Space Served Rooftop / First Floor, main area
Condition Fair
Supplemental Component #2 Split system condensing unit
Location / Space Served Rooftop / Air handler 1
Condition Fair
Supplemental Component #3 Split system condensing unit
Location / Space Served Rooftop / Air handler 2
Condition Fair
Controls and Ventilation
HVAC Control System BAS, pneumatic controls
HVAC Control System Condition Poor
Building Ventilation Roof top exhaust fans
Ventilation System Condition Fair
Anticipated Lifecycle Replacements:
Boilers
Air handling units
Air handler fan motors
Duct fans and motors
Distribution pumps and motors
Fan coil units
Package units
Condensing units
Electric wall heaters
Rooftop exhaust fans
Building automation system
Expansion tank
Actions/Comments:
The HVAC systems are maintained by an outside contractor. It is unknown whether records of the installation, maintenance,
upgrades, and replacement of the HVAC equipment at the property have been maintained.
Approximately 15 percent of the HVAC equipment is original. The HVAC equipment varies in age. HVAC equipment is replaced on
an "as needed" basis.
The HVAC equipment appears to be functioning adequately overall. The property management staff was interviewed about the
historical and recent performance of the equipment and systems. No chronic problems were reported and an overall sense of
satisfaction with the systems was conveyed. However, due to the inevitable failure of parts and components over time, some of the
equipment will require replacement.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
21
www.EMGcorp.com p 800.733.0660
The air handler fan motors lack variable frequency drives (VFD’s). As the motors are fairly substantial in size, the overall system
would benefit from the utilization of VFD’s to reduce full-speed usage and improve efficiency. Installation of VFD’s is highly
recommended.
The facility HVAC is controlled using an outdated pneumatic system supplied by an air compressor. For modernization, reliability,
and increased control, full conversion to a web-based direct digital control (DDC) platform is highly recommended.
7.2. Building Plumbing and Domestic Hot Water
Building Plumbing System
Type Description Condition
Water Supply Piping Copper Fair
Waste/Sewer Piping Cast iron Fair
Vent Piping Cast iron Fair
Water Meter Location Basement riser room
Domestic Water Heaters or Boilers
Components Water Heaters
Fuel Natural gas
Quantity and Input Capacity 1 unit at 129,999 BTU/h
Storage Capacity 80 gallons
Boiler or Water Heater Condition Fair
Supplementary Storage Tanks? No
Storage Tank Quantity and Volume None
Quantity of Storage Tanks 0
Storage Tank Condition --
Domestic Hot Water Circulation Pumps (3 HP and over) No
Adequacy of Hot Water Adequate
Adequacy of Water Pressure Adequate
Plumbing Fixtures
Water Closets Commercial
Toilet (Water Closet) Flush Rating 1.6 GPF
Common Area Faucet Nominal Flow Rate 2.0 GPM
Condition Fair
Anticipated Lifecycle Replacements:
Water heaters
Toilets
Urinals
Sinks
Ejector pumps
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
22
www.EMGcorp.com p 800.733.0660
Actions/Comments:
The plumbing systems appear to be well maintained and functioning adequately. The water pressure appears to be sufficient. No
significant repair actions or short term replacement costs are required. Routine and periodic maintenance is recommended. Future
lifecycle replacements of the components or systems listed above will be required.
7.3. Building Gas Distribution
Gas service is supplied from the gas main on the adjacent public street. The gas meter and regulator is located along the exterior wall
of the building. The gas distribution piping within the building is malleable steel (black iron).
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The pressure and quantity of gas appear to be adequate.
The gas meter and regulator appear to be functioning adequately and will require routine maintenance.
Only limited observation of the gas distribution piping can be made due to hidden conditions.
7.4. Building Electrical
Building Electrical Systems
Electrical Lines Underground Transformer Pad-mounted
Main Service Size 800 Amps Volts 120/208 Volt, three-phase
Meter and Panel Location
Basement mechanical
room Branch Wiring Copper
Conduit Metallic Step-Down
Transformers? No
Security / Surveillance
System? No Building Intercom
System? No
Lighting Fixtures T-12
Main Distribution Condition Fair
Secondary Panel and
Transformer Condition Fair
Lighting Condition Fair
Building Emergency System
Size 26 kW Fuel Natural gas
Generator / UPS Serves
Emergency lights,
elevators Tank Location NA
Testing Frequency Bi-Weekly Tank Type None
Generator / UPS Condition Fair
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
23
www.EMGcorp.com p 800.733.0660
Anticipated Lifecycle Replacements:
Circuit breaker panels
Main switchgear
Interior light fixtures
Emergency generator
Actions/Comments:
The onsite electrical systems up to the meters are owned and maintained by the respective utility company.
The electrical service and capacity appear to be adequate for the property’s demands.
The switchgear and some panels are original 1976 components. The electrical service is reportedly adequate for the facility’s needs.
However, due to the age of the panels and switchgear and increasing difficulty of obtaining replacement parts over time, lifecycle
replacements are recommended per above.
The light fixtures throughout most of the facility utilize older, inefficient T-12 lamps. Replacement with newer fixtures with electronic
ballasts and T-8 lamps is highly recommended to save substantial amounts of energy.
7.5. Building Elevators and Conveying Systems
Building Elevators
Manufacturer Dover Machinery Location Ground floor or basement
adjacent to shaft
Safety Stops Mechanical Emergency Equipment Yes
Cab Floor Finish Vinyl-tiled Cab Wall Finish Plastic-laminated wood
Hydraulic Elevators 1 car at 2500 lbs
Overhead Traction Elevators None
Freight Elevators None
Machinery Condition Fair
Controls Condition Fair
Cab Finish Condition Fair
Other Conveyances Dumb-waiter (non-functional, not inventoried)
Other Conveyance Condition Failed
Anticipated Lifecycle Replacements:
Elevator controls
Hydraulic machinery
Actions/Comments:
The elevators are serviced by Schindler Elevator Corp on a routine basis. The elevator machinery and controls are the originally
installed system. The elevators are utilizing outdated controls and equipment. Full modernization is recommended. A budgetary
cost for this work is included.
The elevators are inspected on an annual basis by the municipality, and a certificate of inspection is displayed in the elevator cab.
The inspection certificates have expired. It is common for inspections to occur behind schedule. A new inspection should be
scheduled as soon as possible.
The emergency communication equipment in the elevator cabs appears to be functional. Equipment testing is not within the scope of
the work.
The finishes in the elevator cabs will require replacement. The cost to replace the finishes is relatively insignificant and the work can
be performed as part of the property management’s operations program.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
24
www.EMGcorp.com p 800.733.0660
7.6. Fire Protection and Security Systems
Item Description
Type Wet pipe
Fire Alarm System
Central Alarm Panel ☒ Battery-Operated Smoke
Detectors ☐ Alarm Horns ☒
Annunciator Panels ☒ Hard-Wired Smoke
Detectors ☒ Strobe Light Alarms ☒
Pull Stations ☒ Emergency Battery-Pack
Lighting ☒ Illuminated EXIT Signs ☒
Alarm System
Condition Fair
Sprinkler System
None ☐ Standpipes ☒ Backflow Preventer ☒
Hose Cabinets ☐ Fire Pumps ☐ Siamese Connections ☐
Suppression
Condition Fair
Central Alarm Panel
System
Location of Alarm Panel Installation Date of Alarm Panel
Water meter room 2013
Fire Extinguishers
Last Service Date Servicing Current?
January, 2016 Yes
Hydrant Location Adjacent to building
Siamese Location None
Special Systems Kitchen Suppression System ☐Computer Room Suppression System ☐
Anticipated Lifecycle Replacements:
Central alarm panel
Alarm devices and system
Actions/Comments:
Some of the ceiling mounted brackets which hold an area of fire suppression piping in the old storage area were observed to have
become detached. The piping is resting on wooden shelving. This condition increases the likelihood of a pipe leak or an inadvertent
triggering of the suppression system. This condition must be repaired.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
25
www.EMGcorp.com p 800.733.0660
8. Interior Spaces
8.1. Interior Finishes
The facility is currently vacant. Previously it was used as a bank, and then concurrently as an exercise gym and a massage therapy
facility. Planned renovations will result in all 14,000 square feet of the facility being used for municipal offices for the City of Yorkville.
The most significant interior spaces include open spaces, offices, and bank vaults. Supporting areas include hallways, stairs, restrooms
mechanical rooms, utility closets, and back-of-house areas.
The following table generally describes the locations and typical conditions of the interior finishes within the facility:
Typical Floor Finishes
Floor Finish Locations General Condition
Rubber flooring Basement exercise area, small area in upper area Poor
Vinyl plank Renovated area of basement Fair
Carpet Basement hallways, upper floor vaults and office
areas Poor
Quarry tile Entry vestibules Fair
Ceramic tile Restrooms Fair
Concrete Mechanical/utility areas, storage area Fair
Typical Wall Finishes
Wall Finish Locations General Condition
Painted drywall Throughout building Fair
Ceramic tile Restrooms Fair
Exposed CMU/masonry Mechanical/utility areas, storage area Fair
Typical Ceiling Finishes
Ceiling Finish Locations General Condition
Suspended T-bar (Acoustic) Some areas of basement, upper floor restrooms,
stairwells Fair
Hard glued tiles Small vault, upper floor Fair
Exposed structure Throughout building Fair
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
26
www.EMGcorp.com p 800.733.0660
Interior Doors
Item Type Condition
Interior Doors
Hollow core
Solid core
Bank vault (solid metal)
Fair
Door Framing Wood
Metal
Fair
Fire Doors Yes Fair
Anticipated Lifecycle Replacements:
Carpet
Vinyl plank
Ceramic tile
Interior paint
Suspended acoustic ceiling tile
Hard tile ceilings
Interior doors
Actions/Comments:
The interior areas were last partially renovated around 2012.
The interior finishes have mostly been removed from the facility. Some of the remaining fixtures are in fair condition, however
comprehensive renovations are planned for the facility are in order to render it compatible with the planned facility uses. A general
cost for this work has been included in the report.
The ceiling tiles have isolated areas of water-damage in several areas, including the basement coat room, the area immediately
outside of the main bank vault, and the older section of the facility. The damaged ceiling tiles need to be replaced. This work can be
accomplished as part of the planned renovations.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
27
www.EMGcorp.com p 800.733.0660
9. Other Structures
A storage building is located at the northeast corner of the parking area. The maintenance building is a cast-in-place concrete structure
set on a concrete slab. The building is integrated into the retaining wall.
Anticipated Lifecycle Replacements:
Storage shed doors
Actions/Comments:
The door weather strip and threshold are deteriorated and damaged. The threshold is splintering and portions of the weather strip are
missing. Replacement of these components is recommended. The cost for this work is relatively insignificant and can be
accomplished through the City’s routine maintenance program.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
28
www.EMGcorp.com p 800.733.0660
10. Certification
The City of Yorkville retained EMG to perform this Facility Condition Assessment in connection with its continued operation of New City
Hall, 102 East Van Emmon Street, Yorkville, Illinois, the “Property”. It is our understanding that the primary interest of the City of
Yorkville is to locate and evaluate materials and building system defects that might significantly affect the value of the property and to
determine if the present Property has conditions that will have a significant impact on its continued operations.
The conclusions and recommendations presented in this report are based on the brief review of the plans and records made available
to our Project Manager during the site visit, interviews of available property management personnel and maintenance contractors
familiar with the Property, appropriate inquiry of municipal authorities, our Project Manager’s walk-through observations during the site
visit, and our experience with similar properties.
No testing, exploratory probing, dismantling or operating of equipment or in depth studies were performed unless specifically required
under Section 2 of this report. This assessment did not include engineering calculations to determine the adequacy of the Property’s
original design or existing systems. Although walk-through observations were performed, not all areas were observed (See Section 4.2
for areas observed). There may be defects in the Property, which were in areas not observed or readily accessible, may not have been
visible, or were not disclosed by management personnel when questioned. The report describes property conditions at the time that
the observations and research were conducted.
This report has been prepared on behalf of and exclusively for the use of the City of Yorkville for the purpose stated within Section 2 of
this report. The report, or any excerpt thereof, shall not be used by any party other than the City of Yorkville or for any other purpose
than that specifically stated in our agreement or within Section 2 of this report without the express written consent of EMG.
Any reuse or distribution of this report without such consent shall be at the City of Yorkville and the recipient’s sole risk, without liability
to EMG.
Prepared by: Kevin Koranda,
Project Manager
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
29
www.EMGcorp.com p 800.733.0660
11. Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: EMG Accessibility Checklist
Appendix D: Pre-Survey Questionnaire
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
NEW CITY HALL EMG PROJECT NO: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
PHOTO
#1:
EAST ELEVATION PHOTO
#2:
SOUTH ELEVATION
PHOTO
#3:
EAST ELEVATION PHOTO
#4:
NORTH ELEVATION
PHOTO
#5:
NORTH ELEVATION PHOTO
#6:
WEST ELEVATION
NEW CITY HALL EMG PROJECT NO: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
PHOTO
#7:
SOUTH ELEVATION PHOTO
#8:
PARKING AREA
PHOTO
#9:
DAMAGED ASPHALT PHOTO
#10:
DAAMGED ASPHALT
PHOTO
#11:
HILL ADJACENT PARKING AREA PHOTO
#12:
SIDEWALK
NEW CITY HALL EMG PROJECT NO: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
PHOTO
#13:
SITE LIGHTING PHOTO
#14:
PARKING AREA RETAINING WALL
PHOTO
#15:
SIDEWALK RETAINING WALL PHOTO
#16:
PARKING LOT
PHOTO
#17:
SIDEWALK, EAST END OF SITE PHOTO
#18:
STAIRS, EAST EDGE OF SITE
NEW CITY HALL EMG PROJECT NO: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
PHOTO
#19:
STORAGE ROOM PHOTO
#20:
BUILDING SOFFIT
PHOTO
#21:
STOREFRONT WINDOWS PHOTO
#22:
MISSING AREA OF WINDOW GASKET
PHOTO
#23:
DAMAGED WINDOW FRAME PHOTO
#24:
EFFLORESCENCE ON BRICK
NEW CITY HALL EMG PROJECT NO: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
PHOTO
#25:
RECESSED LIGHT FIXTURE PHOTO
#26:
ROOF, WATER STAINING
PHOTO
#27:
ROOF, CLOGGED DRAIN PHOTO
#28:
ROOF, TPO MEMBRANE
PHOTO
#29:
ROOF, MODIFIED BITUMINOUS
MEMBRANE
PHOTO
#30:
PACKAGE UNIT
NEW CITY HALL EMG PROJECT NO: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
PHOTO
#31:
EXHAUST FAN PHOTO
#32:
CONDENSING UNIT
PHOTO
#33:
MAIN DISTRIBUTION PANEL PHOTO
#34:
BOILER ROOM
PHOTO
#35:
BOILER PHOTO
#36:
ELECTRICAL/SUMP PUMP ROOM
NEW CITY HALL EMG PROJECT NO: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
PHOTO
#37:
COLD WATER ENTRY PHOTO
#38:
GENERATOR
PHOTO
#39:
MAIN ENTRY DOORS PHOTO
#40:
UPPER FLOOR, MAIN SPACE
PHOTO
#41:
UPPER FLOOR, EAST WALL PHOTO
#42:
ROOF DECK, CORROSION
NEW CITY HALL EMG PROJECT NO: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
PHOTO
#43:
OLD BUILDING AREA, UPPER FLOOR PHOTO
#44:
WATER STAIN ADJACENT TO EAST
WALL
PHOTO
#45:
CEILING, OLDER AREA PHOTO
#46:
BRICK INTERIOR WALL
PHOTO
#47:
STEEL STRUCTURAL BEAM PHOTO
#48:
WATER DAMAGE
NEW CITY HALL EMG PROJECT NO: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
PHOTO
#49:
FIRE ALARM STROBE AND
SPRINKLER HEAD
PHOTO
#50:
EXIT SIGN AND EMERGENCY LIGHT
FIXTURE
PHOTO
#51:
ELEVATOR CAB INTERIOR PHOTO
#52:
WATER DAMAGED CEILING TILE
PHOTO
#53:
UPPER FLOOR BANK VAULT ROOM PHOTO
#54:
WATER DAMAGED CEILING TILE
NEW CITY HALL EMG PROJECT NO: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
PHOTO
#55:
MAIN ENTRY VESTIBULE, QUARRY
TILE
PHOTO
#56:
STAIRWELL
PHOTO
#57:
CENTRAL STAIRWELL PHOTO
#58:
BASEMENT, VACANT AREA
PHOTO
#59:
RENOVATED BASEMENT AREA PHOTO
#60:
OLD STORAGE ROOM
NEW CITY HALL EMG PROJECT NO: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
PHOTO
#61:
DETERIORATING CONCRETE PHOTO
#62:
DETERIORATING CONCRETE
PHOTO
#63:
DETERIORATING CONCRETE PHOTO
#64:
SHOWERS
PHOTO
#65:
TOILET STALLS PHOTO
#66:
SINKS
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
New City Hall
Project Number:
122700.17R000-001.322
Source:
Google Earth Pro
On-Site Date:
May 16, 2017
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
Appendix C:
EMG Accessibility Checklist
Page 1 of 4
Date Completed: May 16, 2017
Property Name: New City Hall
EMG Project Number: 122700.17R000-001.322
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? ✓
2
Have any ADA improvements been made
to the property? ✓
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? ✓
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
✓
5
Is any litigation pending related to ADA
issues? ✓
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
✓ 1 accessible space, no signage
2
Are there sufficient van-accessible parking
spaces available? ✓ None
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
✓
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
✓
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
✓ No depression, only a slope
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
✓
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) ✓
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? ✓
3
Does the width between railings appear at
least 36 inches? ✓
Page 2 of 4
Ramps (cont.) Yes No NA Comments
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
✓
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? ✓
2
If the main entrance is inaccessible, are
there alternate accessible entrances? ✓
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
✓
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? ✓
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? ✓ Signs removed from doors
3
Is there a path of travel that does not
require the use of stairs? ✓ Elevator
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? ✓
2
Are there visual and audible signals inside
cars indicating floor change? ✓ Indicator not functional
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? ✓
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? ✓
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? ✓
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? ✓
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? ✓ Route is clear to one restroom, threshold
renders room inaccessible
2
Are pull handles push/pull or lever type?
✓
3
Are there audible and visual fire alarm
devices in the toilet rooms? ✓
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? ✓
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? ✓ All but one at older area of upper floor
6
In unisex toilet rooms, are there safety
alarms with pull cords? ✓
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? ✓
8
Are grab bars provided in toilet stalls?
✓
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? ✓
10
Are sink handles operable with one hand
without grasping, pinching or twisting? ✓
11
Are exposed pipes under sink sufficiently
insulated against contact? ✓
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
✓
Page 4 of 4
Guest Rooms (cont.) Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
✓
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
✓
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. ✓
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
✓
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
✓
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
✓
*Based on visual observation only. The slope was not confirmed through measurements.
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
Appendix D:
Pre-Survey Questionnaire
NEW CITY HALL EMG PROJECT NO.: 122700.17R000-001.322
www.EMGcorp.com p 800.733.0660
On the day of the site visit, provide EMG's Field Observer access to all of the available documents listed below.
Provide copies if possible.
INFORMATION REQUIRED
1. All available construction documents (blueprints) for
the original construction of the building or for any tenant
improvement work or other recent construction work.
2. A site plan, preferably 8 1/2" X 11", which depicts the
arrangement of buildings, roads, parking stalls, and other
site features.
3. For commercial properties, provide a tenant list which
identifies the names of each tenant, vacant tenant units,
the floor area of each tenant space, and the gross and
net leasable area of the building(s).
4. For apartment properties, provide a summary of the
apartment unit types and apartment unit type quantities,
including the floor area of each apartment unit as
measured in square feet.
5. For hotel or nursing home properties, provide a
summary of the room types and room type quantities.
6. Copies of Certificates of Occupancy, building permits,
fire or health department inspection reports, elevator
inspection certificates, roof or HVAC warranties, or any
other similar, relevant documents.
7. The names of the local utility companies which serve
the property, including the water, sewer, electric, gas,
and phone companies.
8. The company name, phone number, and contact
person of all outside vendors who serve the property,
such as mechanical contractors, roof contractors, fire
sprinkler or fire extinguisher testing contractors, and
elevator contractors.
9. A summary of recent (over the last 5 years) capital
improvement work which describes the scope of the
work and the estimated cost of the improvements.
Executed contracts or proposals for improvements.
Historical costs for repairs, improvements, and
replacements.
10. Records of system and material ages (roof, MEP,
paving, finishes, furnishings).
11. Any brochures or marketing information.
12. Appraisal, either current or previously prepared.
13. Current occupancy percentage and typical turnover
rate records (for commercial and apartment properties).
14. Previous reports pertaining to the physical condition
of property.
15. ADA survey and status of improvements
implemented.
16. Current / pending litigation related to property
condition.
Your timely compliance with this request is greatly appreciated.
Report#Name/Address Immediate RepairsImmediate FCIImmediate Rating 10 year repair10 year FCI10 yearratingItemsofNoteReport #Name/AddressRepairs FCIRatingrepair FCIratingItems of Note001102 E. Van Emmon Street $ 1,093,997 99.0% Very Poor $ 540,971 49.1% PoorRoof, Parking Lot, Sump Pump Drainage, Lighting, elevator, monitoring system002609 Bridge Street $ 449,683 49.0% Poor $ 118,443 12.9% PoorSiding, Electrical/Plumbing/Lighting Upgrades, Fire/Sprinkler, Garage Demo003Old Jail $ 132,443 14.4% Poor$ 2,823 3.0% GoodStructural, Roof, Repointing.004CityHall‐800GameFarmRoad$271 02377%Fair$860 87724 7%PoorRoofHVAC/FurnaceParkingLotLightingSprinklerSystemRetrofit004City Hall ‐ 800 Game Farm Road $ 271,023 7.7%Fair$ 860,877 24.7%PoorRoof, HVAC/Furnace, Parking Lot, Lighting, Sprinkler System Retrofit005Beecher Center 908 Game Farm Rd $ 43,159 2.6% Good$ 1,068,339 61.8% Very PoorSidewalks, parking lot, fire alarm system, ADA upgrades006Beecher Storage Shed $ ‐ 0.0% Good$ 2,925 31.9% Poor007BeecherConcessionStand$6 52414 2%Poor$56 084122 0%VeryPoorSprinklerSystem;ADAupdgrades007Beecher Concession Stand $ 6,524 14.2%Poor$ 56,084 122.0%Very PoorSprinkler System; ADA updgrades008Library $ 1,543 0.0% Good$ 2,042,965 27.8% PoorADA upgrades009Non‐Kiwanis Park Shelter $ 31 0.0% Good$ 37,070 40.4% PoorRoof010131EHydraulic$21 62554%Fair$81 56620 6%PoorSprinklerSystemFireAlarmSystemADAFurnaceWaterheater010131 E. Hydraulic $ 21,625 5.4%Fair$ 81,566 20.6%PoorSprinkler System, Fire Alarm System, ADA, Furnace, Water heater013Yak Shack $ 41,907 28.7% Poor$ 99,325 44.2% PoorParking (gravel replacement) Fire Alarm System, Sprinkler System016Stepping Stone Park $ ‐ 0.0% Good$ 4,597 5.0% Good017StBidPkCi$9 18610 0%Fi$44 02648 1%PPkiWlkLd iFiSt017Stevens Bridge Park Concession $ 9,186 10.0% Fair$ 44,026 48.1% PoorParking, Walkway, Landscaping, Fire System018Parks Storage Shed $ ‐ 0.0% Good$ 3,490 38.1% PoorPainting019Non Park Tin Storage Shed $ ‐ 0.0% Good$ 23,619 25.8% Poorkb$d$kd(k)020Town Square Park Gazebo $ 281 0.1% Good$ 44,883 100.0% Very PoorParking, Landscaping, ADA Signage (parking)023Countryside Lift Station $ ‐ 0.0% Good$ 133,788 52.2% PoorPublic Works, garage building024610 Tower Lane $ 22,328 7.2% Fair$ 61,871 19.9% PoorSprinkler System, Fire Alarm System, Floor Repair025Lift Station Bruell $ ‐ 0.0% Good$ 115,015 52.3% Poor034Treatment Facility Well 3 and 4 $ 31,195 4.4% Good$ 215,662 30.2% PoorSprinkler System035Treatment Facility Well 7 $ 25,596 4.4% Good$ 157,269 26.8% PoorFire System036Parks Facility 185 Wolf Street $ 109,797 5.9% Fair$ 53,136 2.8% GoodSprinkler System, Fire Alarm sytem037ARC 201 W Hydraulic $ 51,805 14.1% Poor$ 228,750 61.6% Very PoorFire System, Fire Alarm System, Asphalt pavement mill and overlayyyyyppy038Non‐Rice Park Shelter 545 Poplar Drive $ ‐ 0.0% Good $ 101,565 216.0% Very Poor039River Front Park Pavillion $ 78 0.0% Good$ 1,478 1.6% GoodRepair loose and missing stones$$,pg040River Front Park $ 41,907 45.7% Poor$ 147,516 161.0% Very PoorParking lot seal and stripe, repair of concrete retaining wall041Booster PRV Station $ ‐ 0.0% Good$ 192,050 84.2% Very PoorNon Central Booster Pump 042Non Central Booster Pump 101 E Beaver $ ‐ 0.0% Good $ 81,774 81.8% Very Poor043Public Works Office and Garage ‐ 610 Tower $ 97,079 6.0% Fair$ 953,792 59.0% PoorRepair damage to right elevation exterior wall, fire alarm system, mill /overlay parking lot, fire supression system043Tower $ 97,079 6.0%Fair$ 953,792 59.0%Poor/overlay parking lot, fire supression system044Salt Storage Building $ 21,687 7.4% Fair$ 59,722 20.3% PoorFull replacement of exterior metal siding045Treatment Facility Well 8 and 9 $ 25,596 4.4% Good$ 253,760 43.3% PoorFire Supression System046Wellno.3$16,57890.5%VeryPoor$‐N/AN/ASoilSampling(PostDemo),BuildingDemo046Well no. 3 $ 16,578 90.5%Very Poor$ ‐ N / AN / ASoil Sampling (Post Demo), Building Demo047Well 4 $ ‐ 0.0% Good$ 1,913 9.1% Fair
Report#Name/Address Immediate RepairsImmediate FCIImmediate Rating 10 year repair10 year FCI10 yearratingItemsofNoteReport #Name/AddressRepairs FCIRatingrepair FCIratingItems of Note001102 E. Van Emmon Street $ 1,093,997 99.0% Very Poor $ 540,971 49.1% PoorRoof, Parking Lot, Sump Pump Drainage, Lighting, elevator, monitoring system046Wellno3$16,57890.5%VeryPoor$‐N/AN/ASoilSampling(PostDemo)BuildingDemo046Well no. 3 $ 16,578 90.5%Very Poor$ ‐ N / AN / ASoil Sampling (Post Demo), Building Demo002609 Bridge Street $ 449,683 49.0% Poor $ 118,443 12.9% PoorSiding, Electrical/Plumbing/Lighting Upgrades, Fire/Sprinkler, Garage Demo040RiverFrontPark$41 90745 7%Poor$147 516161 0%VeryPoorParkinglotsealandstriperepairofconcreteretainingwall040River Front Park $ 41,907 45.7%Poor$ 147,516 161.0%Very PoorParking lot seal and stripe, repair of concrete retaining wall013Yak Shack $ 41,907 28.7% Poor$ 99,325 44.2% PoorParking (gravel replacement) Fire Alarm System, Sprinkler System003Old Jail $ 132,443 14.4% Poor$ 2,823 3.0% GoodStructural, Roof, Repointing.007BeecherConcessionStand$6 52414 2%Poor$56 084122 0%VeryPoorSprinklerSystem;ADAupdgrades007Beecher Concession Stand $ 6,524 14.2%Poor$ 56,084 122.0%Very PoorSprinkler System; ADA updgrades037ARC 201 W Hydraulic $ 51,805 14.1% Poor$ 228,750 61.6% Very PoorFire System, Fire Alarm System, Asphalt pavement mill and overlay017Stevens Bridge Park Concession $ 9,186 10.0% Fair$ 44,026 48.1% PoorParking, Walkway, Landscaping, Fire System004City Hall ‐ 800 Game Farm Road $ 271,023 7.7% Fair $ 860,877 24.7% PoorRoof, HVAC/Furnace, Parking Lot, Lighting, Sprinkler System Retrofit044Salt Storage Building $ 21,687 7.4% Fair$ 59,722 20.3% PoorFull replacement of exterior metal sidingP bliWkb ildi024Public Works, garage building610 Tower Lane $ 22,328 7.2% Fair $ 61,871 19.9% PoorSprinkler System, Fire Alarm System, Floor RepairPublic Works Office and Garage ‐ 610 $i$Repair damage to right elevation exterior wall, fire alarm system, mill /lklf043Tower $ 97,079 6.0% Fair$ 953,792 59.0% Poor/overlay parking lot, fire supression system036Parks Facility 185 Wolf Street $ 109,797 5.9% Fair$ 53,136 2.8% GoodSprinkler System, Fire Alarm sytem010131 E. Hydraulic $ 21,625 5.4% Fair$ 81,566 20.6% PoorSprinkler System, Fire Alarm System, ADA, Furnace, Water heater034Treatment Facility Well 3 and 4 $ 31,195 4.4% Good$ 215,662 30.2% PoorSprinkler System035Treatment Facility Well 7 $ 25,596 4.4% Good$ 157,269 26.8% PoorFire System045Treatment Facility Well 8 and 9 $ 25,596 4.4% Good$ 253,760 43.3% PoorFire Supression System005Beecher Center 908 Game Farm Rd $ 43,159 2.6% Good$ 1,068,339 61.8% Very PoorSidewalks, parking lot, fire alarm system, ADA upgrades020Town Square Park Gazebo $ 281 0.1% Good$ 44,883 100.0% Very PoorParking, Landscaping, ADA Signage (parking)006Beecher Storage Shed $ ‐ 0.0% Good$ 2,925 31.9% Poorg008Library $ 1,543 0.0% Good$ 2,042,965 27.8% PoorADA upgrades009Non‐Kiwanis Park Shelter $ 31 0.0% Good$ 37,070 40.4% PoorRoof016Stepping Stone Park $ ‐ 0.0% Good$ 4,597 5.0% Goodpp g$$,018Parks Storage Shed $ ‐ 0.0% Good$ 3,490 38.1% PoorPainting019Non Park Tin Storage Shed $ ‐ 0.0% Good$ 23,619 25.8% Poor023Countryside Lift Station $ ‐ 0.0% Good$ 133,788 52.2% Poor023Countryside Lift Station $ 0.0%Good$ 133,788 52.2%Poor025Lift Station Bruell $ ‐ 0.0% Good$ 115,015 52.3% Poor038Non‐Rice Park Shelter 545 Poplar Drive $ ‐ 0.0% Good$ 101,565 216.0% Very Poor038545 Poplar Drive $ 0.0%Good$ 101,565 216.0%Very Poor039River Front Park Pavillion $ 78 0.0% Good$ 1,478 1.6% GoodRepair loose and missing stones041Booster PRV Station $ ‐ 0.0% Good$ 192,050 84.2% Very PoorNonCentralBoosterPump042Non Central Booster Pump 101 E Beaver $ ‐ 0.0% Good $ 81,774 81.8% Very Poor047Well 4 $ ‐ 0.0% Good$ 1,913 9.1% Fair
Report#Name/Address Immediate RepairsImmediate FCIImmediate Rating 10 year repair10 year FCI10 yearratingItemsofNoteReport #Name/AddressRepairs FCIRatingrepair FCIratingItems of Note046Well no. 3 $ 16,578 90.5% Very Poor$ ‐ N / AN / ASoil Sampling (Post Demo), Building Demo038Non‐Rice Park Shelter 545PoplarDrive$‐0.0%Good$101,565216.0%VeryPoor038545 Poplar Drive $ ‐ 0.0%Good$ 101,565 216.0%Very Poor040River Front Park $ 41,907 45.7% Poor$ 147,516 161.0% Very PoorParking lot seal and stripe, repair of concrete retaining wall007Beecher Concession Stand $ 6,524 14.2% Poor$ 56,084 122.0% Very PoorSprinkler System; ADA updgrades020TownSquareParkGazebo$28101%Good$44 883100 0%VeryPoorParkingLandscapingADASignage(parking)020Town Square Park Gazebo $ 281 0.1%Good$ 44,883 100.0%Very PoorParking, Landscaping, ADA Signage (parking)041Booster PRV Station $ ‐ 0.0% Good$ 192,050 84.2% Very Poor042Non Central Booster Pump 101EBeaver$00%Good$81 77481 8%VeryPoor042101 E Beaver $ ‐ 0.0%Good$ 81,774 81.8%Very Poor005Beecher Center 908 Game Farm Rd $ 43,159 2.6% Good$ 1,068,339 61.8% Very PoorSidewalks, parking lot, fire alarm system, ADA upgrades037ARC 201 W Hydraulic $ 51,805 14.1% Poor$ 228,750 61.6% Very PoorFire System, Fire Alarm System, Asphalt pavement mill and overlayPublicWorksOfficeandGarage610Repairdamagetorightelevationexteriorwallfirealarmsystemmill043Public Works Office and Garage ‐ 610 Tower $ 97,079 6.0% Fair $ 953,792 59.0% PoorRepair damage to right elevation exterior wall, fire alarm system, mill /overlay parking lot, fire supression system025Lift Station Bruell $ ‐ 0.0% Good$ 115,015 52.3% Poor023CtidLiftSt ti$00%Gd$133 78852 2%P023Countryside Lift Station $ ‐ 0.0% Good$ 133,788 52.2% Poor001102 E. Van Emmon Street $ 1,093,997 99.0% Very Poor $ 540,971 49.1% PoorRoof, Parking Lot, Sump Pump Drainage, Lighting, elevator, monitoring systemdk$i$klkd017Stevens Bridge Park Concession $ 9,186 10.0% Fair$ 44,026 48.1% PoorParking, Walkway, Landscaping, Fire System013Yak Shack $ 41,907 28.7% Poor$ 99,325 44.2% PoorParking (gravel replacement) Fire Alarm System, Sprinkler System045Treatment Facility Well 8 and 9 $ 25,596 4.4% Good$ 253,760 43.3% PoorFire Supression System009Non‐Kiwanis Park Shelter $ 31 0.0% Good$ 37,070 40.4% PoorRoof018Parks Storage Shed $ ‐ 0.0% Good$ 3,490 38.1% PoorPainting006Beecher Storage Shed $ ‐ 0.0% Good$ 2,925 31.9% Poor034Treatment Facility Well 3 and 4 $ 31,195 4.4% Good$ 215,662 30.2% PoorSprinkler System008Library $ 1,543 0.0% Good$ 2,042,965 27.8% PoorADA upgrades035Treatment Facility Well 7 $ 25,596 4.4% Good$ 157,269 26.8% PoorFire Systemyy019Non Park Tin Storage Shed $ ‐ 0.0% Good$ 23,619 25.8% Poor004City Hall ‐ 800 Game Farm Road $ 271,023 7.7% Fair$ 860,877 24.7% PoorRoof, HVAC/Furnace, Parking Lot, Lighting, Sprinkler System Retrofity$,$,f,/,g,gg,pyf010131 E. Hydraulic $ 21,625 5.4% Fair$ 81,566 20.6% PoorSprinkler System, Fire Alarm System, ADA, Furnace, Water heater044Salt Storage Building $ 21,687 7.4% Fair$ 59,722 20.3% PoorFull replacement of exterior metal sidingPublic Works, garage building024Public Works, garage building610 Tower Lane $ 22,328 7.2% Fair $ 61,871 19.9% PoorSprinkler System, Fire Alarm System, Floor Repair002609 Bridge Street $ 449,683 49.0% Poor$ 118,443 12.9% PoorSiding, Electrical/Plumbing/Lighting Upgrades, Fire/Sprinkler, Garage Demo002609 Bridge Street $ 449,683 49.0%Poor$ 118,443 12.9%PoorSiding, Electrical/Plumbing/Lighting Upgrades, Fire/Sprinkler, Garage Demo047Well 4 $ ‐ 0.0% Good$ 1,913 9.1% Fair016Stepping Stone Park $ ‐ 0.0% Good$ 4,597 5.0% Good003OldJail$132,44314.4%Poor$2,8233.0%GoodStructural,Roof,Repointing.003Old Jail $ 132,443 14.4%Poor$ 2,823 3.0%GoodStructural, Roof, Repointing.036Parks Facility 185 Wolf Street $ 109,797 5.9% Fair$ 53,136 2.8% GoodSprinkler System, Fire Alarm sytem039River Front Park Pavillion $ 78 0.0% Good$ 1,478 1.6% GoodRepair loose and missing stones
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
New Public Works
609 North Bridge Street
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-002.322 September 13, 2017 May 19, 2017
FACILITY CONDITION ASSESSMENT
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1. Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
1.3. Special Issues and Follow-Up Recommendations ...................................................................... 3
1.4. Opinions of Probable Cost .......................................................................................................... 4
1.4.1. Methodology ................................................................................................................................ 4
1.4.2. Immediate Repairs ...................................................................................................................... 4
1.4.3. Replacement Reserves ............................................................................................................... 4
2. Purpose and Scope .............................................................................................................................. 5
2.1. Purpose ....................................................................................................................................... 5
2.2. Scope .......................................................................................................................................... 6
2.3. Personnel Interviewed ................................................................................................................. 7
2.4. Documentation Reviewed ........................................................................................................... 7
2.5. Pre-Survey Questionnaire ........................................................................................................... 7
2.6. Weather Conditions ..................................................................................................................... 7
3. Accessibility and Property Research ................................................................................................. 8
3.1. ADA Accessibility ........................................................................................................................ 8
4. Existing Building Assessment .......................................................................................................... 10
4.1. Unit or Space Types .................................................................................................................. 10
4.2. Inaccessible Areas or Key Spaces Not Observed .................................................................... 10
5. Site Improvements ............................................................................................................................. 11
5.1. Utilities ....................................................................................................................................... 11
5.2. Parking, Paving, and Sidewalks ................................................................................................ 11
5.3. Drainage Systems and Erosion Control .................................................................................... 12
5.4. Topography and Landscaping ................................................................................................... 13
5.5. General Site Improvements ....................................................................................................... 13
6. Building Architectural and Structural Systems ............................................................................... 15
6.1. Foundations ............................................................................................................................... 15
6.2. Superstructure ........................................................................................................................... 15
6.3. Roofing ...................................................................................................................................... 15
6.4. Exterior Walls ............................................................................................................................ 16
6.5. Exterior and Interior Stairs ......................................................................................................... 17
6.6. Exterior Windows and Doors ..................................................................................................... 17
6.7. Patio, Terrace, and Balcony ...................................................................................................... 18
7. Building Mechanical and Plumbing Systems .................................................................................. 19
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC) ..................................................... 19
7.2. Building Plumbing and Domestic Hot Water ............................................................................. 20
7.3. Building Gas Distribution ........................................................................................................... 21
7.4. Building Electrical ...................................................................................................................... 22
7.5. Building Elevators and Conveying Systems .............................................................................. 22
7.6. Fire Protection and Security Systems ....................................................................................... 23
8. Interior Spaces .................................................................................................................................... 24
8.1. Interior Finishes ......................................................................................................................... 24
9. Other Structures ................................................................................................................................. 26
10. Certification ......................................................................................................................................... 27
11. Appendices ......................................................................................................................................... 28
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
1
www.EMGcorp.com p 800.733.0660
1. Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 609 North Bridge Street, Yorkville, IL 60560
Year Constructed/Renovated: Originally constructed early 1900s
Current Occupants: City of Yorkville
Percent Utilization: 0%
Management Point of Contact: Mr. Peter Ratos, Building Code Official, City of Yorkville
630.553.8574 phone
Property Type: Municipal
Site Area: 0.5 acres
Building Area: 2,464 SF
Number of Buildings: 1
Number of Stories: 3
Parking Type and Number of
Spaces: No designated spaces
Building Construction: Conventional wood framed structure with concrete foundation walls
Roof Construction: Pitched roof with asphalt shingles
Exterior Finishes: Wood siding
Heating, Ventilation & Air
Conditioning: Furnace and split system condensing unit
Fire and Life/Safety: Aged fire alarm system with pull stations and exit signs
Dates of Visit: 5/19/2017
On-Site Point of Contact (POC): Peter Ratos
Assessment and Report
Prepared by: Kevin Koranda
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC Good
Structure Fair Plumbing Fair to poor
Roof Fair Electrical Fair to poor
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
2
www.EMGcorp.com p 800.733.0660
Systemic Condition Summary
Vertical Envelope Fair Elevators NA
Interiors Fair Fire Poor
The following bullet points highlight the most significant short term and modernization recommendations:
▪ Wood siding replacement
▪ Electrical system upgrades
▪ Plumbing system upgrades
▪ Lighting upgrades
▪ Sprinkler system retrofit
▪ Fire alarm system upgrades
▪ Interior finish replacement, including: wood floor refinishing, repainting, and carpet replacement
▪ Garage structure demolition
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained in recent years and is in fair overall condition.
According to property management personnel, the property has had a nonexistent capital improvement expenditure program over the
past three years.
1.2. F acility Condition Index (FCI )
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
3
www.EMGcorp.com p 800.733.0660
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
Fci Condition
Rating Definition Percentage
Value
Good In new or well-maintained condition, with no visual evidence
of wear, soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and
functioning condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its
useful or serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal
is now necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 49.0% Poor
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 12.9% Poor
Current Replacement Value (CRV) 2,464 SF * 183.24 / SF = $451,503.36
Year 0 (Current Year) - Immediate Repairs (IR) $449,683
Years 1-10 – Replacement Reserves (RR) $118,443
Total Capital Needs $568,126
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
▪ Wood siding replacement
▪ Electrical system upgrades
▪ Plumbing system upgrades
▪ Lighting upgrades
▪ Sprinkler system retrofit
▪ Fire alarm system upgrades
▪ Interior finish replacement, including: wood floor refinishing, repainting, and carpet replacement
▪ Garage structure demolition
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
1.3. Special Issues and Follow -Up Recommendations
As part of the FCA, a limited assessment of accessible areas of the building(s) was performed to determine the presence of fungal
growth, conditions conducive to fungal growth, and/or evidence of moisture. Property personnel were interviewed concerning any
known or suspected fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Sampling is not a part of this
assessment.
There are no visual indications of the presence of fungal growth, conditions conducive to fungal growth, or evidence of severe moisture
in representative readily accessible areas of the property.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
4
www.EMGcorp.com p 800.733.0660
No studies or follow up recommendations appear to be necessary.
1.4. Opinions of Probable Cost
Cost estimates are attached at the front of this report (following the cover page).
These estimates are based on Invoice or Bid Document/s provided either by the Owner/facility and construction costs developed by
construction resources such as R.S. Means and Marshall & Swift, EMG’s experience with past costs for similar properties, city cost
indexes, and assumptions regarding future economic conditions.
Opinions of probable costs should only be construed as preliminary, order of magnitude budgets. Actual costs most probably wi ll vary
from the consultant’s opinions of probable costs depending on such matters as type and design of suggested remedy, quality of
materials and installation, manufacturer and type of equipment or system selected, field conditions, whether a physical deficiency is
repaired or replaced in whole, phasing of the work (if applicable), quality of contractor, quality of project management exercised, market
conditions, and whether competitive pricing is solicited, etc. ASTM E2018-08 recognizes that certain opinions of probable costs cannot
be developed within the scope of this guide without further study. Opinions of probable c ost for further study should be included in the
FCA.w
1.4.1. Methodology
Based upon site observations, research, and judgment, along with referencing Expected Useful Life (EUL) tables from various industry
sources, EMG opines as to when a system or component will most probably necessitate replacement. Accurate historical replacement
records, if provided, are typically the best source of information. Exposure to the elements, initial quality and installation, extent of use,
the quality and amount of preventive maintenance exercised, etc., are all factors that impact the effective age of a system or
component. As a result, a system or component may have an effective age that is greater or less than its actual chronological age.
The Remaining Useful Life (RUL) of a component or system equals the EUL less its effective age. Projections of Remaining Useful Life
(RUL) are based on continued use of the Property similar to the reported past use. Significant changes in occupants and/or usage may
affect the service life of some systems or components.
Where quantities could not be derived from an actual take-off, lump sum costs or allowances are used. Estimated costs are based on
professional judgment and the probable or actual extent of the observed defect, inclusive of the cost to design, procure, construct and
manage the corrections.
1.4.2. Immediate Repairs
Immediate repairs are opinions of probable costs that require immediate action as a result of: (1) material existing or potential unsafe
conditions, (2) material building or fire code violations, or (3) conditions that, if not addressed, have the potential to result in, or
contribute to, critical element or system failure within one year or will most probably result in a significant escalation of its remedial cost.
1.4.3. Replacement Reserves
Replacement Reserves are for recurring probable expenditures, which are not classified as operation or maintenance expenses. The
replacement reserves should be budgeted for in advance on an annual basis. Replacement Reserves are reasonably predictable both
in terms of frequency and cost. However, Replacement Reserves may also include components or systems that have an
indeterminable life but, nonetheless, have a potential for failure within an estimated time period.
Replacement Reserves exclude systems or components that are estimated to expire after the reserve term and are not considered
material to the structural and mechanical integrity of the subject property. Furthermore, systems and components that are not deemed
to have a material effect on the use of the Property are also excluded. Costs that are caused by acts of God, accidents, or other
occurrences that are typically covered by insurance, rather than reserved for, are also excluded.
Replacement costs are solicited from ownership/property management, EMG’s discussions with service companies, manufacturers'
representatives, and previous experience in preparing such schedules for other similar facilities. Costs for work performed by the
ownership’s or property management’s maintenance staff are also considered.
EMG’s reserve methodology involves identification and quantification of those systems or components requiring capital reserve funds
within the assessment period. The assessment period is defined as the effective age plus the reserve term. Additional information
concerning system’s or component’s respective replacement costs (in today's dollars), typical expected useful lives, and remaining
useful lives were estimated so that a funding schedule could be prepared. The Replacement Reserves Schedule presupposes that all
required remedial work has been performed or that monies for remediation have been budgeted for items defined in the Immediat e
Repair Cost Estimate.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
5
www.EMGcorp.com p 800.733.0660
2. Purpose and Scope
2.1. Purpose
EMG was retained by the client to render an opinion as to the Property’s current general physical condition on the day of the site visit.
Based on the observations, interviews and document review outlined below, this report identifies significant deferred mainten ance
issues, existing deficiencies, and material code violations of record at municipal offices, which affect the Property’s use. Opinions are
rendered as to its structural integrity, building system condition and the Property’s overall condition. The report also notes building
systems or components that have realized or exceeded their typical expected useful lives.
CONDITIONS:
The physical condition of building systems and related components are typically defined as being in one of five conditions: Excellent,
Good, Fair, Poor, Failed or a combination thereof. For the purposes of this report, the following definitions are used:
Excellent = New or very close to new; component or system typically has been installed within the past year, sound and
performing its function. Eventual repair or replacement will be required when the component or system either
reaches the end of its useful life or fails in service.
Good = Satisfactory as-is. Component or system is sound and performing its function, typically within the first third
of its lifecycle. However, it may show minor signs of normal wear and tear. Repair or replacement will be
required when the component or system either reaches the end of its useful life or fails in service.
Fair = Showing signs of wear and use but still satisfactory as-is, typically near the median of its estimated useful
life. Component or system is performing adequately at this time but may exhibit some signs of wear,
deferred maintenance, or evidence of previous repairs. Repair or replacement will be required due to the
component or system’s condition and/or its estimated remaining useful life.
Poor = Component or system is significantly aged, flawed, functioning intermittently or unreliably; displays obvious
signs of deferred maintenance; shows evidence of previous repair or workmanship not in compliance with
commonly accepted standards; has become obsolete; or exhibits an inherent deficiency. The present
condition could contribute to or cause the deterioration of contiguous elements or systems. Either full
component replacement is needed or repairs are required to restore to good condition, prevent premature
failure, and/or prolong useful life.
Failed
= Component or system has ceased functioning or performing as intended. Replacement, repair, or other
significant corrective action is recommended or required.
Not Applicable
= Assigning a condition does not apply or make logical sense, most commonly due to the item in question not
being present.
FORMAT OF THE BODY OF THE REPORT:
Throughout sections 5 through 9 of this report, each report section will typically contain three subsections organized in the following
sequence:
▪ A descriptive table (and/or narrative), which identifies the components assessed, their condition, and other key data points.
▪ A simple bulleted list of Anticipated Lifecycle Replacements, which lists components and assets typically in Excellent, Good, or Fair
condition at the time of the assessment but that will require replacement or some other attention once aged past their estimated
useful life. These listed components are typically included in the associated inventory database with costs identified and budgeted
beyond the first several years.
▪ A bulleted cluster of Actions/Comments, which include more detailed narratives describing deficiencies, recommended repairs, and
short term replacements. The assets and components associated with these bullets are/were typically problematic and in Poor or
Failed condition at the time of the assessment, with corresponding costs included within the first few years.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
6
www.EMGcorp.com p 800.733.0660
PLAN TYPES:
Each line item in the cost database is assigned a Plan Type, which is the primary reason or rationale for the recommended
replacement, repair, or other corrective action. This is the “why” part of the equation. A cost or line item may commonly have more
than one applicable Plan Type; however, only one Plan Type will be assigned based on the “best” fit, typically the one with the greatest
significance. The following Plan Types are listed in general weighted order of importance:
Safety = An observed or reported unsafe condition that if left unaddressed could result in an injury; a system or
component that presents a potential liability risk.
Performance/Integrity = Component or system has failed, is almost failing, performs unreliably, does not perform as intended,
and/or poses a risk to overall system stability.
Accessibility = Does not meet ADA, UFAS, and/or other handicap accessibility requirements.
Environmental = Improvements to air or water quality, including removal of hazardous materials from the building or
site.
Modernization/Adaptation
= Conditions, systems, or spaces that need to be upgraded in appearance or function to meet current
standards, facility usage, or client/occupant needs.
Lifecycle/Renewal
= Any component or system in which future repair or replacement is anticipated beyond the next several
years and/or is of minimal substantial early-term consequence.
2.2. Scope
The standard scope of the Facility Condition Assessment includes the following:
▪ Visit the Property to evaluate the general condition of the building and site improvements, review available construction documents in
order to familiarize ourselves with, and be able to comment on, the in-place construction systems, life safety, mechanical, electrical,
and plumbing systems, and the general built environment.
▪ Identify those components that are exhibiting deferred maintenance issues and provide cost estimates for Immediate Costs and
Replacement Reserves based on observed conditions, maintenance history and industry standard useful life estimates. This will
include the review of documented capital improvements completed within the last five-year period and work currently contracted for, if
applicable.
▪ Provide a full description of the Property with descriptions of in-place systems and commentary on observed conditions.
▪ Provide a general statement of the subject Property’s compliance to Title III of the Americans with Disabilities Act. This will not
constitute a full ADA survey, but will help identify exposure to issues and the need for further review.
▪ Perform a limited assessment of accessible areas of the building(s) for the presence of fungal growth, conditions conducive to fungal
growth, and/or evidence of moisture. EMG will also interview Project personnel regarding the presence of any known or suspected
fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Potentially affected areas will be photographed.
Sampling will not be considered in routine assessments.
▪ List the current utility service providers.
▪ Review maintenance records and procedures with the in-place maintenance personnel.
▪ Observe a representative sample of the interior spaces/units, including vacant spaces/units, in order to gain a clear understanding of
the property’s overall condition. Other areas to be observed include the exterior of the property, the roofs, interior common areas,
and the significant mechanical, electrical and elevator equipment rooms.
▪ Provide recommendations for additional studies, if required, with related budgetary information.
▪ Provide an Executive Summary at the beginning of this report.
▪ Prepare a mechanical equipment inventory list.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
7
www.EMGcorp.com p 800.733.0660
2.3. Personnel Interviewed
The management staff was interviewed for specific information relating to the physical property, available maintenance procedures,
historical performance of key building systems and components, available drawings and other documentation. The following personnel
from the facility and government agencies were interviewed in the process of conducting the FCA:
Name and Title Organization Phone Number
Eric Dhuse
Public Works Director City of Yorkville 630.553.4370
The FCA was performed with the assistance of Eric Dhuse, Public Works Director, City of Yorkville, the onsite Point of Contact (POC),
who was cooperative and provided information that appeared to be accurate based upon subsequent site observations. The onsite
contact is completely knowledgeable about the subject property and answered most questions posed during the interview process. The
property has only been owned by the city for a short period of time. The POC has been involved with the property since its purchase in
2016.
2.4. Documentation Reviewed
Prior to the FCA, relevant documentation was requested that could aid in the knowledge of the subject property’s physical
improvements, extent and type of use, and/or assist in identifying material discrepancies between reported information and observed
conditions. The review of submitted documents does not include comment on the accuracy of such documents or their preparation,
methodology, or protocol. The Documentation Request Form is provided in Appendix E.
2.5. Pre -Survey Questionnaire
A Pre-Survey Questionnaire was sent to the POC prior to the site visit. The questionnaire is included in Appendix E. Information
obtained from the questionnaire has been used in preparation of this report.
2.6. Weather Conditions
5/19/17: Partly cloudy and raining with temperatures in the 60s (°F) and moderate winds.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
8
www.EMGcorp.com p 800.733.0660
3. Accessibilit y and Property Resea rch
3.1. ADA Accessibility
Generally, Title III of the Americans with Disabilities Act (ADA) prohibits discrimination by entities to access and use of “areas of public
accommodations” and “commercial facilities” on the basis of disability. Regardless of its age, these areas and facilities must be
maintained and operated to comply with the Americans with Disabilities Act Accessibility Guidelines (ADAAG).
Buildings completed and occupied after January 26, 1992 are required to comply fully with the ADAAG. Existing facilities constructed
prior to this date are held to the lesser standard of compliance to the extent allowed by structural feasibility and the financial resources
available. As an alternative, a reasonable accommodation pertaining to the deficiency must be made.
During the FCA, a limited visual observation for ADA accessibility compliance was conducted. The scope of the visual observation was
limited to those areas set forth in EMG’s Abbreviated Accessibility Checklist provided in Appendix D of this report. It is understood by
the Client that the limited observations described herein does not comprise a full ADA Compliance Survey, and that such a survey is
beyond the scope of EMG’s undertaking. Only a representative sample of areas was observed and, other than as shown on the
Abbreviated Accessibility Checklist, actual measurements were not taken to verify compliance.
The facility does not appear to be accessible with Title III of the Americans with Disabilities Act. However, the building is not planned to
be used as an area of public accommodation. Achieving ADA compliance would require substantial modifications to the facility and
modifications may not be necessary given the planned facility use. With this acknowledged, the issues are nonetheless noted below.
The facility does not appear to be accessible with Title III of the Americans with Disabilities Act. Elements as defined by the ADAAG
that are not accessible as stated within the priorities of Title III, are as follows:
Parking
▪ Adequate number of designated parking stalls and signage for cars are not provided. Provide description of location where new
stalls are required (adjacent to rental office/adjacent to XX building)
▪ Adequate number of designated parking stalls and signage for vans are not provided.
▪ Access aisles adjacent to parking spaces, crossing hazardous vehicle areas, from main roadways or public transportation stops to
the building sidewalks and entrances are not provided.
Ramps
▪ The building requires the construction of a straight entrance ramp with handrails to allow wheelchair access.
Entrances/Exits
▪ Install buzzer or intercom for assistance and service at exterior entrance doors or parking space.
▪ Existing entrance doors are not wide enough to accommodate wheelchair access and clear floor space beside the door swing is
lacking.
▪ Existing stairs are set too close to the front doors for wheelchair access at ground level door
▪ Lever action hardware is not provided
Paths of Travel
▪ There are no accessible paths of travel to the second floor or the basement of the building.
▪ Existing carpeting is not securely attached or has a pile thickness exceeding 1/2”.
▪ Stair handrails do not extend beyond the top and bottom risers.
▪ Stair handrails do not extend beyond the top and bottom risers.
▪ Lower objects mounted higher than 27” off the floor, project more than 4” into walks, halls, corridors, passageways, or aisles.
Restrooms
▪ Existing restrooms do not meet any ADA criteria and are inaccessible.
A full ADA Compliance Survey may reveal additional aspects of the property that are not in compliance.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
9
www.EMGcorp.com p 800.733.0660
Corrections of these conditions should be addressed from a liability standpoint, but are not necessarily code violations. The Americans
with Disabilities Act Accessibility Guidelines concern civil rights issues as they pertain to the disabled and are not a construction code,
although many local jurisdictions have adopted the Guidelines as such. The cost to address the achievable items noted above is
included in the cost tables.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
10
www.EMGcorp.com p 800.733.0660
4. Existing B uilding Assessment
4.1. Unit or Space Types
All 5,000 square feet of the building are currently unoccupied. The facility was previously used as a residential home. The spaces are
vacant. Primary building areas include: living quarters, a kitchen, and an unfinished basement.
4.2. Inaccessible Areas or Key Spaces N ot Observed
All of the interior spaces were observed in order to gain a clear understanding of the property’s overall condition. Other areas accessed
included the site within the property boundaries, exterior of the property and the roof (observed from the ground). Areas of note that
were either inaccessible or not observed for other reasons are listed in the table below:
A “down unit” or area is a term used to describe a unit or space that cannot be occupied due to poor conditions such as fire damage,
water damage, missing equipment, damaged floor, wall or ceiling surfaces, or other significant deficiencies. There are no down units or
areas.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
11
www.EMGcorp.com p 800.733.0660
5. Site Improvements
5.1. Utilities
The following table identifies the utility suppliers and the condition and adequacy of the services.
Site Utilities
Utility Supplier Condition and Adequacy
Sanitary sewer City of Yorkville Good and Adequate
Storm sewer City of Yorkville Good and Adequate
Domestic water City of Yorkville Good and Adequate
Electric service Commonwealth Edison Good and Adequate
Natural gas service Nicor Gas Good and Adequate
Actions/Comments:
▪ According to the POC, the utilities provided are adequate for the property. There are no unique, onsite utility systems such as
emergency electrical generators, septic systems, water or waste water treatment plants, or propane gas tanks.
5.2. Parking, Paving, and Sidewalks
Item Description
Main Ingress and Egress North Bridge Street
Access from East
Additional Entrances NA
Additional Access from NA
Paving and Flatwork
Item Material Last Work Done Condition
Entrance Driveway Apron Asphalt 1995 Fair
Parking Lot Asphalt 1995 Fair
Drive Aisles None NA --
Service Aisles None NA --
Sidewalks Concrete 1995 Fair
Curbs None NA --
Site Stairs None NA --
Pedestrian Ramps None NA --
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
12
www.EMGcorp.com p 800.733.0660
Parking Count
Open Lot Carport Private Garage Subterranean
Garage
Freestanding Parking
Structure
No designated
spaces - - - -
Total Number of ADA Compliant Spaces NA
Number of ADA Compliant Spaces for Vans 0
Total Parking Spaces NA
Parking Ratio (Spaces/Apartments) NA
Method of Obtaining Parking Count Physical count
Exterior Stairs
Location Material Handrails Condition
None -- -- -
Anticipated Lifecycle Replacements:
▪ Asphalt seal coating
▪ Asphalt pavement milling and overlaying
▪ Sidewalks
Actions/Comments:
▪ The asphalt pavement exhibits isolated areas of failure and deterioration, such as alligator cracking, transverse cracking an d
localized depressions. The most severely damaged areas of paving must be cut and patched in order to maintain the integrity of the
overall pavement system. All of the paving must be overlaid with new asphalt paving in order to maintain the integrity of the overall
pavement system. Milling is recommended as part of the overall repair work.
5.3. Drainage Systems and Erosion Control
Drainage System and Erosion Control
System Exists At Site Condition
Surface Flow ☒ Fair
Inlets ☒ --
Swales ☐ --
Detention pond ☐ --
Lagoons ☐ --
Ponds ☐ --
Underground Piping ☐ --
Pits ☐ --
Municipal System ☒ --
Dry Well ☐ --
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
13
www.EMGcorp.com p 800.733.0660
Anticipated Lifecycle Replacements:
▪ No components of significance
Actions/Comments:
▪ There is no evidence of storm water runoff from adjacent properties. The storm water system appears to provide adequate runoff
capacity. There is no evidence of major ponding or erosion
5.4. Topography and Landscaping
Item Description
Site Topography Slopes gently down from the north side of the property to the south property
line.
Landscaping Trees Grass Flower
Beds Planters
Drought
Tolerant
Plants
Decorative
Stone None
☒ ☒ ☐ ☐ ☐ ☐ ☐
Landscaping
Condition Fair
Irrigation
Automatic
Underground Drip Hand Watering None
☐ ☐ ☐ ☒
Irrigation Condition --
Retaining Walls
Type Location Condition
None -- --
Anticipated Lifecycle Replacements:
▪ No components of significance
Actions/Comments:
▪ The topography and adjacent uses do not appear to present conditions detrimental to the property. There are no significant areas of
erosion.
5.5. General Site Improvements
Property Signage
Property Signage None
Street Address Displayed? Yes
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
14
www.EMGcorp.com p 800.733.0660
Site and Building Lighting
Site Lighting
None Pole Mounted Bollard Lights Ground
Mounted
Parking Lot
Pole Type
☒ ☐ ☐ ☐ ☐
--
Building Lighting
None Wall Mounted Recessed Soffit
☐ ☒ ☐
Fair
REFUSE DISPOSAL
Refuse Disposal Individual garbage bins
Dumpster Locations Mounting Enclosure Contracted? Condition
NA - vacant None None NA --
Other Site Amenities
Description Location Condition
Playground Equipment None -- --
Tennis Courts None -- --
Basketball Court None -- --
Swimming Pool None -- --
Anticipated Lifecycle Replacements:
▪ No components of significance
Actions/Comments:
▪ No significant actions are identified at the present time. On-going periodic maintenance is highly recommended.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
15
www.EMGcorp.com p 800.733.0660
6. Building Architectural and Structural Systems
6.1. Foundations
Building Foundation
Item Description Condition
Foundation Masonry foundation walls Fair
Basement and Crawl Space Concrete slab and concrete walls Fair
Anticipated Lifecycle Replacements:
▪ No components of significance
Actions/Comments:
▪ The foundations and footings cannot be directly observed. However, there are isolated areas of standing water, efflorescence, and
excessive moisture conditions on the walls and floors in the subterranean basement. The subterranean walls must be repaired and
waterproofed. The scope of the repair includes excavation, the installation of a new waterproof system and footing drains, and the
backfilling and re-compacting of the excavated soil.
6.2. Superstructure
Building Superstructure
Item Description Condition
Framing / Load-Bearing Walls Conventional wood/metal studs Fair
Basement Concrete slab Fair
Upper Floor Framing Wood joists Fair
Upper Floor Decking Wood Fair
Roof Framing Wood trusses Fair
Roof Decking Wood boards Fair
Anticipated Lifecycle Replacements:
▪ No components of significance
Actions/Comments:
▪ The superstructure is exposed in some locations, which allows for limited observation. Walls and floors appear to be plumb, level,
and stable. There are no significant signs of deflection or movement.
6.3. Roofing
Primary Roof
Type / Geometry Gable Roof Finish Asphalt shingles
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
16
www.EMGcorp.com p 800.733.0660
Primary Roof
Maintenance In-house Staff Roof Age 18 Yrs
Flashing Sheet metal Warranties None
Parapet Copings None Roof Drains Gutters and downspouts
Fascia Wood fascia Insulation Fiberglass batts
Soffits Exposed Soffits Skylights No
Attics Yes Ponding No
Ventilation Source-1 Gable end vents Leaks Observed Yes
Ventilation Source-2 None Roof Condition Fair
The primary roof is located over the entirety of the building.
Anticipated Lifecycle Replacements:
▪ Asphalt shingles
Actions/Comments:
▪ The roof finishes appear to be more than 15 years old. Information regarding roof warranties or bonds was not available. The roofs
are maintained by the in-house maintenance staff.
▪ According to the POC, there are no active roof leaks. There is no evidence of active roof leaks.
▪ There is no evidence of roof deck or insulation deterioration. The roof substrate and insulation should be inspected during any future
roof repair or replacement work.
▪ Roof drainage appears to be adequate. Clearing and minor repair of drain system components should be performed regularly as part
of the property management’s routine maintenance and operations program.
▪ The attics are not accessible and it could not be determined if there is moisture, water intrusion, or excessive daylight in the attics.
There is no evidence of moisture, water intrusion, or excessive daylight in the attics. The insulation in the attics appears to be
adequate.
6.4. Exterior Walls
Building Exterior Walls
Type Location Condition
Primary Finish Painted wood Fair to Poor
Secondary Finish None NA
Accented with Wood trim Fair to Poor
Soffits Not Applicable --
Building sealants (caulking) are located between dissimilar materials, at joints, and around window and door openings.
Anticipated Lifecycle Replacements:
▪ Wood siding
▪ Exterior painting
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
17
www.EMGcorp.com p 800.733.0660
Actions/Comments:
▪ The wood siding has significant areas of weathered wood siding and wood trim. The painted finishes across much of the building are
deteriorated. The damaged materials must be replaced. In addition to these repairs, the exterior walls will require painting.
6.5. Exterior and Interior Stairs
Building Exterior and Interior Stairs
Type Description Riser Handrail Balusters Condition
Building Exterior Stairs Cast in place concrete Closed Metal Metal Fair
Building Exterior Stairs Wood-framed Open Wood Wood Fair
Building Interior Stairs Wood-framed Closed Wood Wood Fair
Anticipated Lifecycle Replacements:
▪ No components of significance
Actions/Comments:
▪ The wood stairs at the north side of the building have isolated evidence of deteriorated, treads, risers, and balusters. The damaged
stair components must be replaced.
6.6. Exterior Windows and Doors
Building Windows
Window Framing Glazing Location Window
Screen Condition
Wood framed, operable Single glaze Throughout building ☐ Poor
Building Doors
Main Entrance Doors Door Type Condition
Wood, partially glazed Fair
Secondary Entrance Doors Solid core wood or metal Fair
Service Doors None --
Overhead Doors None --
Anticipated Lifecycle Replacements:
▪ Wooden windows
▪ Glazed doors
▪ Metal door
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
18
www.EMGcorp.com p 800.733.0660
Actions/Comments:
▪ The windows are antiquated, energy-inefficient units with single-pane glazing. Some of the windows are difficult to open and close
and several of the windows were loose in their sashes. Window replacement is recommended.
6.7. Patio, Terrace, and Balcony
Not applicable. There are no patios, terraces, or balconies.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
19
www.EMGcorp.com p 800.733.0660
7. Building Mechanical and Plumbing Systems
See the Mechanical Equipment List in the Appendices for the quantity, manufacturer’s name, model number, capacity and year of
manufacturer of the major mechanical equipment, if available.
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC)
Building Central Heating System
Primary Heating System Type Forced air furnace
Quantity and Capacity of Major Components 1 furnace at 95 MBH
Total Heating Capacity 95 MBH
Heating Fuel Natural gas
Location of Major Equipment Basement
Space Served by System Entire building
Age Ranges 2015
Condition Good
Heat Exchanger Condition --
Building Central Cooling System
Primary Cooling System Type Condensing unit
Quantity and Capacity of Major Components 1 condensing unit at 3 tons
Total Cooling Capacity 3 tons
Refrigerant R-410A
Cooling Towers NA
Location of Major Equipment Adjacent north wall
Space Served by System Entire building
Age Ranges 2015
Condensing Unit Condition Good
Supplemental Components
Supplemental Component #1 NA
Location / Space Served NA
Condition --
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
20
www.EMGcorp.com p 800.733.0660
Controls and Ventilation
HVAC Control System Individual non-programmable thermostats/controls
HVAC Control System Condition Poor
Building Ventilation Natural ventilation only
Ventilation System Condition Fair
Anticipated Lifecycle Replacements:
▪ Furnace
▪ Split system condensing unit
Actions/Comments:
▪ The HVAC systems are maintained by the in-house maintenance staff. Records of the installation, maintenance, upgrades, and
replacement of the HVAC equipment at the property have been maintained since the property was first occupied.
▪ Approximately 0 percent of the HVAC equipment is original. HVAC equipment is replaced on an "as needed" basis.
▪ The HVAC equipment appears to be functioning adequately overall. The property management staff was interviewed about the
historical and recent performance of the equipment and systems. No chronic problems were reported and an overall sense of
satisfaction with the systems was conveyed. However, due to the inevitable failure of parts and components over time, some of the
equipment will require replacement.
7.2. Building Plumbing and Domestic Hot Water
Building Plumbing System
Type Description Condition
Water Supply Piping Copper and galvanized iron Fair to poor
Waste/Sewer Piping Cast iron and PVC Fair to poor
Vent Piping Cast iron and PVC Fair to poor
Water Meter Location Basement
Domestic Water Heaters or Boilers
Components Water Heater
Fuel Natural gas
Quantity and Input Capacity 1 unit at 32 MBH
Storage Capacity 40 gallons
Boiler or Water Heater Condition Fair
Supplementary Storage Tanks? No
Storage Tank Quantity & Volume 0
Quantity of Storage Tanks 0
Storage Tank Condition --
Domestic Hot Water Circulation Pumps (3 HP and over) No
Adequacy of Hot Water Unknown
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
21
www.EMGcorp.com p 800.733.0660
Domestic Water Heaters or Boilers
Adequacy of Water Pressure Unknown
Plumbing Fixtures
Water Closets Residential
Toilet (Water Closet) Flush Rating 3.5 GPF
Common Area Faucet Nominal Flow Rate 2.0+ GPM
Condition Fair to poor
Anticipated Lifecycle Replacements:
▪ Supply distribution piping
▪ Waste/sanitary distribution piping
▪ Water heater
▪ Toilets
▪ Sinks
▪ Bathtubs
Actions/Comments:
▪ Most of the domestic water lines are galvanized iron. To date there has been no history of chronic leaks or water pressure problems.
However, it is quite common for galvanized iron piping to develop problems due to long-term corrosion with thinning walls and/or
interior mineral deposit accumulation, especially once it has aged 40 or 50 years. EMG highly encourages some easily accessible
pipe sections be examined to more accurately determine the interior pipe wall conditions after nearly 60 years of use. Pending these
results, consideration should be given to replacing all the plumbing supply lines with copper. A budgetary cost for full replacement is
included.
▪ The cast iron sanitary piping is aged and appears to be original to the building. The piping is corroded and generally in poor condition.
The budgetary cost above includes an amount for the replacement of the original sanitary piping.
▪ The restroom accessories and fixtures are antiquated and exhibit significant wear. The restroom accessories and fixtures require
replacement.
7.3. Building Gas D istribution
Gas service is supplied from the gas main on the adjacent public street. The gas meter and regulator is located along the exterior wall
of the building. The gas distribution piping within the building is malleable steel (black iron).
Anticipated Lifecycle Replacements:
▪ No components of significance
Actions/Comments:
▪ The pressure and quantity of gas appear to be adequate.
▪ The gas meter and regulator appear to be functioning adequately and will require routine maintenance.
▪ Only limited observation of the gas distribution piping can be made due to hidden conditions.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
22
www.EMGcorp.com p 800.733.0660
7.4. Building Electrical
Building Electrical Systems
Electrical Lines Overhead Transformer Pole-mounted
Main Service Size 100 Amps Volts 120/208 Volt, three-phase
Meter & Panel Location Basement Branch Wiring Copper
Conduit Metallic Step-Down
Transformers? No
Security / Surveillance
System? No Building Intercom
System? No
Lighting Fixtures Incandescent
Main Distribution Condition Fair
Lighting Condition Fair to poor
Building Emergency System
Size None Fuel --
Generator / UPS Serves -- Tank Location --
Testing Frequency -- Tank Type --
Generator / UPS Condition --
Anticipated Lifecycle Replacements:
▪ Circuit breaker panel
▪ Interior light fixtures
▪ Distribution wiring
Actions/Comments:
▪ The onsite electrical systems up to the meters are owned and maintained by the respective utility company.
▪ The electrical service and capacity appear to be adequate for the property’s demands.
▪ Some of the electrical components within the building, including the knob-and-tube style wiring, are original. A partial
modernization/upgrade is recommended to the aging interior electrical infrastructure. An overall budgetary allowance is included to
account for some corresponding wiring and sub-feed replacements and upgrades.
7.5. Building Elevators and Conveying Systems
Not applicable. There are no elevators or conveying systems.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
23
www.EMGcorp.com p 800.733.0660
7.6. Fire Protection and Security Systems
Item Description
Type None
Fire Alarm System
Central Alarm Panel ☐ Battery-Operated Smoke
Detectors ☒ Alarm Horns ☒
Annunciator Panels ☐ Hard-Wired Smoke
Detectors ☐ Strobe Light Alarms ☐
Pull Stations ☒ Emergency Battery-Pack
Lighting ☐ Illuminated EXIT Signs ☒
Alarm System
Condition Poor
Sprinkler System
None ☒ Standpipes ☐ Backflow Preventer ☐
Hose Cabinets ☐ Fire Pumps ☐ Siamese Connections ☐
Suppression
Condition Fair
Central Alarm Panel
System
Location of Alarm Panel Installation Date of Alarm Panel
None NA
Fire Extinguishers
Last Service Date Servicing Current?
None located NA
Hydrant Location Adjacent streets
Siamese Location None
Special Systems Kitchen Suppression System ☐ Computer Room Suppression System ☐
Anticipated Lifecycle Replacements:
▪ Exit light fixture
Actions/Comments:
▪ Fire extinguishers appear to be missing at all locations. New fire extinguishers must be installed at all required locations immediately.
▪ The fire alarm systems appear somewhat antiquated and not up to current standards. The system utilized outdated components a nd
lacks strobe light alarm, does not have a sufficient number of pull stations, has non-functional lighted exit signs and no backup light
fixtures. Due to the age of the components and apparent shortcomings, a full modernization project is recommended. As part of the
major planned short term renovations, a facility-wide fire alarm modernization is recommended. A budgetary cost is included.
▪ The building is not protected by fire suppression. Due to its construction date, the facility is most likely “grandfathered” by code and
the installation of fire sprinklers not required until major renovations are performed. Regardless of when or if installatio n of facility-
wide fire suppression is required by the governing municipality, EMG recommends a retrofit be performed. As part of the major
recommended short term renovations, a facility-wide fire suppression retrofit is recommended. A budgetary cost is included.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
24
www.EMGcorp.com p 800.733.0660
8. I nterior Spaces
8.1. I nterior Finishes
All 2,464 square feet of the building are currently unoccupied. The facility was previously a single-family home. The spaces are vacant.
The following table generally describes the locations and typical conditions of the interior finishes within the facility:
Typical Floor Finishes
Floor Finish Locations General Condition
Wood Throughout first floor living room areas, second
floor bedrooms Fair to poor
Carpet Stairwell, first floor bedroom Poor
Vinyl tile Kitchen, bathrooms Fair to poor
Concrete Basement Fair
Typical Wall Finishes
Wall Finish Locations General Condition
Painted plaster Throughout building Fair
Painted CMU Basement Fair
Typical Ceiling Finishes
Ceiling Finish Locations General Condition
Painted plaster Throughout building Fair
Interior Doors
Item Type Condition
Interior Doors Solid core/hollow core Fair
Door Framing Wood Fair
Fire Doors No NA
Anticipated Lifecycle Replacements:
▪ Carpet
▪ Vinyl tile
▪ Wood flooring refinishing
▪ Interior painting
▪ Interior doors
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
25
www.EMGcorp.com p 800.733.0660
Actions/Comments:
▪ It appears that the interior finishes have not been renovated within the last 30 years.
▪ The interior finishes are old, worn, and outdated The VCT and carpeting is aged. The wood flooring is worn in some areas and will
require refinishing. Partial interior renovations that include comprehensive updating of the interior finishes are recommended as part
of the overall facility renovation.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
26
www.EMGcorp.com p 800.733.0660
9. Other Structures
A garage building is located to the west of the main building. The garage is a wood framed structure set on a concrete slab. The
garage is deteriorating and in poor overall condition.
Actions/Comments:
▪ The property management stated that the City currently plans on demolishing the garage. No replacement costs for any of the garage
finishes are included in the report. A budgetary allowance for the demolition work is included.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
27
www.EMGcorp.com p 800.733.0660
10. Certification
The City of Yorkville retained EMG to perform this Facility Condition Assessment in connection with its continued operation of New
Public Works, 609 North Bridge Street, Yorkville, IL, the “Property”. It is our understanding that the primary interest of the City of
Yorkville is to locate and evaluate materials and building system defects that might significantly affect the value of the property and to
determine if the present Property has conditions that will have a significant impact on its continued operations.
The conclusions and recommendations presented in this report are based on the brief review of the plans and records made available
to our Project Manager during the site visit, interviews of available property management personnel and maintenance contractors
familiar with the Property, appropriate inquiry of municipal authorities, our Project Manager’s walk-through observations during the site
visit, and our experience with similar properties.
No testing, exploratory probing, dismantling or operating of equipment or in depth studies were performed unless specifically required
under Section 2 of this report. This assessment did not include engineering calculations to determine the adequacy of the Property’s
original design or existing systems. Although walk-through observations were performed, not all areas were observed (See Section 4.2
for areas observed). There may be defects in the Property, which were in areas not observed or readily accessible, may not have been
visible, or were not disclosed by management personnel when questioned. The report describes property conditions at the time that
the observations and research were conducted.
This report has been prepared on behalf of and exclusively for the use of the City of Yorkville for the purpose stated within Section 2 of
this report. The report, or any excerpt thereof, shall not be used by any party other than the City of Yorkville or for any other purpose
than that specifically stated in our agreement or within Section 2 of this report without the express written consent of EMG.
Any reuse or distribution of this report without such consent shall be at the City of Yorkville and the recipient’s sole risk, without liability
to EMG.
Prepared by: Kevin Koranda,
Project Manager
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
28
www.EMGcorp.com p 800.733.0660
11. Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: EMG Accessibility Checklist
Appendix D: Pre-Survey Questionnaire
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
PHOTO
#1:
FRONT ENTRANCE PHOTO
#2:
FRONT ELEVATION
PHOTO
#3:
NORTH ELEVATION PHOTO
#4:
SOUTH ELEVATION
PHOTO
#5:
SOUTH ELEVATION PHOTO
#6:
WEST ELEVATION
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
PHOTO
#7:
SITE PHOTO
#8:
SIDEWALK
PHOTO
#9:
SIDEWALK PHOTO
#10:
ASPHALT DRIVEWAY
PHOTO
#11:
GARAGE PHOTO
#12:
ENTRY DOOR
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
PHOTO
#13:
ENTRY STEPS PHOTO
#14:
FRONT ENTRY STEPS
PHOTO
#15:
WINDOWS PHOTO
#16:
SMALL BASEMENT WINDOW
PHOTO
#17:
NORTH ENTRY DOOR PHOTO
#18:
WOOD SIDING
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
PHOTO
#19:
NORTH STAIRS PHOTO
#20:
ROOF DECKING
PHOTO
#21:
INSULATION PHOTO
#22:
WOOD WINDOW
PHOTO
#23:
LOAD CENTER PHOTO
#24:
FURNACE
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
PHOTO
#25:
CONDENSING UNIT PHOTO
#26:
THERMOSTAT
PHOTO
#27:
WATER HEATER PHOTO
#28:
GALVANIZED WATER PIPE
PHOTO
#29:
CAST IRON SANITARY PIPE PHOTO
#30:
CAST IRON SANITARY PIPE, AGED
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
PHOTO
#31:
PULL STATION PHOTO
#32:
FIRE ALARM BELL
PHOTO
#33:
EXIT SIGN PHOTO
#34:
SMOKE DETECTOR
PHOTO
#35:
KITCHEN, VINYL TILE PHOTO
#36:
KITCHEN CABINETS
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
PHOTO
#37:
WOOD FLOORING PHOTO
#38:
WOOD FLOORING
PHOTO
#39:
BUILT-IN CABINETRY PHOTO
#40:
WINDOWS
PHOTO
#41:
CARPET PHOTO
#42:
TOILET
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
PHOTO
#43:
SINK PHOTO
#44:
TUB
PHOTO
#45:
SINK PHOTO
#46:
STAIRWELL
PHOTO
#47:
WOOD FLOORING PHOTO
#48:
SECOND FLOOR EXIT DOOR, METAL
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
PHOTO
#49:
LIGHT FIXTURE PHOTO
#50:
LIGHT FIXTURE
PHOTO
#51:
WOOD FLOOR PHOTO
#52:
BATHROOM, SECOND FLOOR
PHOTO
#53:
VINYL TILE PHOTO
#54:
BATHTUB
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
PHOTO
#55:
BASEMENT STAIRS PHOTO
#56:
CONCRETE SLAB
PHOTO
#57:
CONCRETE LAUNDRY SINK PHOTO
#58:
WORKSHOP ROOM NORTH OF
STAIRS
PHOTO
#59:
EFFLORESCENCE AND WATER
STAINING
PHOTO
#60:
WATER DAMAGED WALL
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
Appendix B:
S ite Plan
Site Plan
Project Name:
New Public Works
Project Number:
122700.17R000-002.322
Source:
Google Earth Pro
On-Site Date:
5/19/2017
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
Appendix C:
EMG Accessibility Checklist
Page 1 of 4
Date Completed: 5/19/17
Property Name: New Public Works
EMG Project Number: 122700.17R000-002.322
Building History Yes No Unk Comments
1 Has an ADA survey previously been
completed for this property? ✔
2 Have any ADA improvements been made
to the property? ✔
3 Does a Transition Plan / Barrier Removal
Plan exist for the property? ✔
4 Has building ownership or management
received any ADA related complaints that
have not been resolved?
✔
5 Is any litigation pending related to ADA
issues? ✔
Parking Yes No NA Comments
1 Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
✔
2 Are there sufficient van-accessible parking
spaces available? ✔
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
✔
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
✔
5 Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
✔
6 If required does signage exist directing you
to accessible parking and an accessible
building entrance?
✔
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) ✔
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? ✔
Page 2 of 4
Ramps Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? ✔
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
✔
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? ✔
2
If the main entrance is inaccessible, are
there alternate accessible entrances? ✔
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
✔
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? ✔
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? ✔
3
Is there a path of travel that does not
require the use of stairs? ✔
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? ✔
2
Are there visual and audible signals inside
cars indicating floor change? ✔
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? ✔
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? ✔
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? ✔
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? ✔
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? ✔
2
Are pull handles push/pull or lever type?
✔
3
Are there audible and visual fire alarm
devices in the toilet rooms? ✔
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? ✔
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? ✔
6
In unisex toilet rooms, are there safety
alarms with pull cords? ✔
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? ✔
8
Are grab bars provided in toilet stalls?
✔
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? ✔
10
Are sink handles operable with one hand
without grasping, pinching or twisting? ✔
11
Are exposed pipes under sink sufficiently
insulated against contact? ✔
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
✔
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
✔
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
✔
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. ✔
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
✔
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards. ✔
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
✔
*Based on visual observation only. The slope was not confirmed through measurements.
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
Appendix D:
Pre-Survey Questionnaire
NEW PUBLIC WORKS EMG PROJECT NO.: 122700.17R000-002.322
www.EMGcorp.com p 800.733.0660
On the day of the site visit, provide EMG's Field Observer access to all of the available documents listed below.
Provide copies if possible.
INFORMATION REQUIRED
1. All available construction documents (blueprints) for
the original construction of the building or for any tenant
improvement work or other recent construction work.
2. A site plan, preferably 8 1/2" X 11", which depicts the
arrangement of buildings, roads, parking stalls, and other
site features.
3. For commercial properties, provide a tenant list which
identifies the names of each tenant, vacant tenant units,
the floor area of each tenant space, and the gross and
net leasable area of the building(s).
4. For apartment properties, provide a summary of the
apartment unit types and apartment unit type quantities,
including the floor area of each apartment unit as
measured in square feet.
5. For hotel or nursing home properties, provide a
summary of the room types and room type quantities.
6. Copies of Certificates of Occupancy, building permits,
fire or health department inspection reports, elevator
inspection certificates, roof or HVAC warranties, or any
other similar, relevant documents.
7. The names of the local utility companies which serve
the property, including the water, sewer, electric, gas,
and phone companies.
8. The company name, phone number, and contact
person of all outside vendors who serve the property,
such as mechanical contractors, roof contractors, fire
sprinkler or fire extinguisher testing contractors, and
elevator contractors.
9. A summary of recent (over the last 5 years) capital
improvement work which describes the scope of the
work and the estimated cost of the improvements.
Executed contracts or proposals for improvements.
Historical costs for repairs, improvements, and
replacements.
10. Records of system & material ages (roof, MEP,
paving, finishes, furnishings).
11. Any brochures or marketing information.
12. Appraisal, either current or previously prepared.
13. Current occupancy percentage and typical turnover
rate records (for commercial and apartment properties).
14. Previous reports pertaining to the physical condition
of property.
15. ADA survey and status of improvements
implemented.
16. Current / pending litigation related to property
condition.
Your timely compliance with this request is greatly appreciated.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Historic Jail
111 West Madison Street
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-003.322 September 13, 2017 May 17, 2017
FACILITY CONDITION ASSESSMENT
Immediate Repairs Report
Historic Jail
9/13/2017
Location NameEMG Renamed Item NumberID Cost Description QuantityUnit Unit Cost Subtotal Deficiency Repair Estimate *
Historic Jail 1.3 609536 Engineer, Environmental, Mold Remediation, Evaluate/Report 1 EA $3,162.50 $3,163 $3,163
Historic Jail 5.2 609539 Exterior Stairs, Concrete, Replace 15 SF $48.94 $734 $734
Historic Jail 5.5 609221 Lighting Fixture, 80 W, Replace 2 EA $256.88 $514 $514
Historic Jail 5.5 609191 Exterior Light Pole 1 EA $2,721.00 $2,721 $2,721
Historic Jail 6.2 609223 Structural Frame 1000 SF $25.10 $25,100 $25,100
Historic Jail 6.2 609216 Study, Structural, Superstructure,1 EA $10,120.00 $10,120 $10,120
Historic Jail 6.3 609196 Roof, , Replace 60 SF $10.52 $631 $631
Historic Jail 6.3 609225 Roof, Premium Grade, Replace 3765 SF $5.04 $18,975 $18,975
Historic Jail 6.4 609174 Brick Veneer Exterior Wall, Exterior, 1-2 Stories, Repair 80 SF $48.56 $3,884 $3,884
Historic Jail 6.4 609179 Brick Veneer Exterior Wall, Exterior, 1-2 Stories, Repair 600 SF $41.28 $24,770 $24,770
Historic Jail 6.4 609228 Exterior Wall 80 LF $2.82 $226 $226
Historic Jail 6.4 609232 Field Stone, Exterior, 1-2 Stories, Repair 150 SF $49.82 $7,473 $7,473
Historic Jail 6.4 609188 Wood Shakes/Shingles, 1-2 Stories, Replace 90 SF $6.69 $602 $602
Historic Jail 6.5 609183 Interior Stairs/Ramp, Interior Stairs, Replace 110 SF $44.53 $4,898 $4,898
Historic Jail 6.6 609181 Window, 1-2 Stories, 12 SF, Replace 4 EA $719.86 $2,879 $2,879
Historic Jail 6.6 609175 Exterior Door, Solid Core, Fully Glazed, Exterior Door, Replace 2 EA $1,982.31 $3,965 $3,965
Historic Jail 6.6 609193 Exterior Door, Solid Core, Painted, Exterior Door, Replace 2 EA $1,423.11 $2,846 $2,846
Historic Jail 6.6 609234 Overhead Door, 144 SF, Replace 1 EA $2,634.03 $2,634 $2,634
Historic Jail 7.6 609205 Fire Extinguisher, , Replace 5 EA $356.54 $1,783 $1,783
Historic Jail 7.6 614544 Emergency Lighting Pack, 2 Light w/ Battery, Replace 1 EA $1,227.87 $1,228 $1,228
Historic Jail 8.1 609227 Interior Walls, Interior Wall, Repair 1800 SF $3.18 $5,726 $5,726
Historic Jail 8.1 609219 Ceilings, Ceiling, Repair 850 SF $7.32 $6,221 $6,221
Immediate Repairs Total $131,093
* Location Factor included in totals.
Replacement Reserves Report
Historic Jail
9/13/2017
Location
Name
EMG Renamed Item
Number ID Cost Description Lifespan
(EUL)EAge RUL QuantityUnit Unit Cost Subtotal 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036
Deficiency
Repair
Estimate
Historic Jail 1.3 609536 Engineer, Environmental, Mold Remediation, Evaluate/Report 0 2016 0 1 EA $3,162.50 $3,163 $3,163 $3,163
Historic Jail 5.2 609539 Exterior Stairs, Concrete, Replace 50 50 0 15 SF $48.94 $734 $734 $734
Historic Jail 5.2 609180 Parking Lot, Parking Lot, Repair 5 3 2 1000 SF $0.38 $380 $380 $380 $380 $380 $1,518
Historic Jail 5.2 609236 Parking Lot, Parking Lot, Repair 25 7 18 1000 SF $3.28 $3,280 $3,280 $3,280
Historic Jail 5.5 609221 Lighting Fixture, 80 W, Replace 20 27 0 2 EA $256.88 $514 $514 $514
Historic Jail 5.5 609191 Exterior Light Pole 20 27 0 1 EA $2,721.00 $2,721 $2,721 $2,721
Historic Jail 6.2 609223 Structural Frame 50 50 0 1000 SF $25.10 $25,100 $25,100 $25,100
Historic Jail 6.2 609216 Study, Structural, Superstructure,0 50 0 1 EA $10,120.00 $10,120 $10,120 $10,120
Historic Jail 6.3 609196 Roof, , Replace 20 27 0 60 SF $10.52 $631 $631 $631
Historic Jail 6.3 609225 Roof, Premium Grade, Replace 30 41 0 3765 SF $5.04 $18,975 $18,975 $18,975
Historic Jail 6.3 609213 Roof, , Replace 20 18 2 150 SF $9.00 $1,349 $1,349 $1,349
Historic Jail 6.4 609174 Brick Veneer Exterior Wall, Exterior, 1-2 Stories, Repair 0 121 0 80 SF $48.56 $3,884 $3,884 $3,884
Historic Jail 6.4 609179 Brick Veneer Exterior Wall, Exterior, 1-2 Stories, Repair 25 41 0 600 SF $41.28 $24,770 $24,770 $24,770
Historic Jail 6.4 609228 Exterior Wall 10 17 0 80 LF $2.82 $226 $226 $226 $451
Historic Jail 6.4 609232 Field Stone, Exterior, 1-2 Stories, Repair 0 121 0 150 SF $49.82 $7,473 $7,473 $7,473
Historic Jail 6.4 609188 Wood Shakes/Shingles, 1-2 Stories, Replace 20 41 0 90 SF $6.69 $602 $602 $602
Historic Jail 6.5 609183 Interior Stairs/Ramp, Interior Stairs, Replace 50 50 0 110 SF $44.53 $4,898 $4,898 $4,898
Historic Jail 6.6 609181 Window, 1-2 Stories, 12 SF, Replace 30 41 0 4 EA $719.86 $2,879 $2,879 $2,879
Historic Jail 6.6 609175 Exterior Door, Solid Core, Fully Glazed, Exterior Door, Replace 25 41 0 2 EA $1,982.31 $3,965 $3,965 $3,965
Historic Jail 6.6 609193 Exterior Door, Solid Core, Painted, Exterior Door, Replace 25 41 0 2 EA $1,423.11 $2,846 $2,846 $2,846
Historic Jail 6.6 609234 Overhead Door, 144 SF, Replace 35 41 0 1 EA $2,634.03 $2,634 $2,634 $2,634
Historic Jail 7.6 609205 Fire Extinguisher, , Replace 15 22 0 5 EA $356.54 $1,783 $1,783 $1,783 $3,565
Historic Jail 7.6 614544 Emergency Lighting Pack, 2 Light w/ Battery, Replace 10 26 0 1 EA $1,227.87 $1,228 $1,228 $1,228 $2,456
Historic Jail 8.1 609227 Interior Walls, Interior Wall, Repair 0 39 0 1800 SF $3.18 $5,726 $5,726 $5,726
Historic Jail 8.1 609219 Ceilings, Ceiling, Repair 0 39 0 850 SF $7.32 $6,221 $6,221 $6,221
Totals, Unescalated $131,093 $0 $1,729 $0 $0 $0 $0 $380 $0 $0 $1,453 $0 $380 $0 $0 $1,783 $0 $380 $3,280 $0 $140,477
Totals, Escalated (3.0% inflation, compounded annually)$131,093 $0 $1,834 $0 $0 $0 $0 $467 $0 $0 $1,953 $0 $541 $0 $0 $2,777 $0 $627 $5,585 $0 $144,877
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1. Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
1.3. Special Issues and Follow-Up Recommendations ...................................................................... 3
1.4. Opinions of Probable Cost .......................................................................................................... 4
1.4.1. Methodology ................................................................................................................................ 4
1.4.2. Immediate Repairs ...................................................................................................................... 4
1.4.3. Replacement Reserves ............................................................................................................... 4
2. Purpose and Scope .............................................................................................................................. 6
2.1. Purpose ....................................................................................................................................... 6
2.2. Scope .......................................................................................................................................... 7
2.3. Personnel Interviewed ................................................................................................................. 7
2.4. Documentation Reviewed ........................................................................................................... 8
2.5. Pre-Survey Questionnaire ........................................................................................................... 8
2.6. Weather Conditions ..................................................................................................................... 8
3. Accessibility and Property Research ................................................................................................. 9
3.1. ADA Accessibility ........................................................................................................................ 9
4. Existing Building Assessment .......................................................................................................... 10
4.1. Unit or Space Types .................................................................................................................. 10
4.2. Inaccessible Areas or Key Spaces Not Observed .................................................................... 10
5. Site Improvements ............................................................................................................................. 11
5.1. Utilities ....................................................................................................................................... 11
5.2. Parking, Paving, and Sidewalks ................................................................................................ 11
5.3. Drainage Systems and Erosion Control .................................................................................... 12
5.4. Topography and Landscaping ................................................................................................... 13
5.5. General Site Improvements ....................................................................................................... 13
6. Building Architectural and Structural Systems ............................................................................... 15
6.1. Foundations ............................................................................................................................... 15
6.2. Superstructure ........................................................................................................................... 15
6.3. Roofing ...................................................................................................................................... 16
6.4. Exterior Walls ............................................................................................................................ 17
6.5. Exterior and Interior Stairs ......................................................................................................... 17
6.6. Exterior Windows and Doors ..................................................................................................... 18
6.7. Patio, Terrace, and Balcony ...................................................................................................... 18
7. Building Mechanical and Plumbing Systems .................................................................................. 19
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC) ..................................................... 19
7.2. Building Plumbing and Domestic Hot Water ............................................................................. 20
7.3. Building Gas Distribution ........................................................................................................... 21
7.4. Building Electrical ...................................................................................................................... 21
7.5. Building Elevators and Conveying Systems .............................................................................. 22
7.6. Fire Protection and Security Systems ....................................................................................... 22
8. Interior Spaces .................................................................................................................................... 24
8.1. Interior Finishes ......................................................................................................................... 24
9. Other Structures ................................................................................................................................. 26
10. Certification ......................................................................................................................................... 27
11. Appendices ......................................................................................................................................... 28
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
1
www.EMGcorp.com p 800.733.0660
1. Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 111 West Madison Street, Yorkville, Illinois 60560
Year Constructed/Renovated: Originally constructed 1893
Addition/restoration 1970s
Current Occupants: None
Percent Utilization: 0%
Management Point of Contact: Mr. Peter Ratos, Building Code Official, City of Yorkville
630.553.8574 phone
Property Type: Municipal
Site Area: 0.30 acres
Building Area: 5,000 SF
Number of Buildings: 1
Number of Stories: 3
Parking Type and Number of
Spaces: 3 spaces adjacent to street
Building Construction: Conventional wood framed structure with areas of reinforced concrete
Roof Construction: Pitched roof with asphalt shingles
Flat roofs with built-up membrane at small area
Exterior Finishes: Brick Veneer
Field stone
Heating, Ventilation and Air
Conditioning:
Central system with boiler serving older area
Furnace and split system condensing unit serving newer area and
garage
Fire and Life/Safety: Hydrants, extinguishers, and one backup light fixture.
Dates of Visit: 5/17/2016
On-Site Point of Contact (POC): Peter Ratos
Assessment and Report
Prepared by: Kevin Koranda
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC Poor
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
2
www.EMGcorp.com p 800.733.0660
Systemic Condition Summary
Structure Poor Plumbing Poor
Roof Failed Electrical Poor
Vertical Envelope Poor Elevators NA
Interiors Failed Fire Poor
The following bullet points highlight the most significant short term and modernization recommendations:
Structural evaluation and repairs
Roof replacement
Exterior brick repointing
Foundation wall repointing
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been poorly maintained in recent years and is in poor overall condition.
According to property management personnel, the property has had a nonexistent capital improvement expenditure program over the
past three years.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
3
www.EMGcorp.com p 800.733.0660
Fci Condition
Rating Definition Percentage
Value
Good In new or well-maintained condition, with no visual evidence
of wear, soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and
functioning condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its
useful or serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal
is now necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 14.4% Poor
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 0.3% Good
Current Replacement Value (CRV) 5,000 SF * 183.24 / SF = $916,186
Year 0 (Current Year) - Immediate Repairs (IR) $132,443
Years 1-10 – Replacement Reserves (RR) $2,823
Total Capital Needs $135,266
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Structural evaluation and repairs
Roof replacement
Exterior brick repointing
Foundation wall repointing
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
1.3. Special Issues and Follow-Up Recommendations
As part of the FCA, a limited assessment of accessible areas of the building(s) was performed to determine the presence of fungal
growth, conditions conducive to fungal growth, and/or evidence of moisture. Property personnel were interviewed concerning any
known or suspected fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Sampling is not a part of this
assessment.
Areas of suspect fungal growth, fungal or mildew-like odors, moisture, elevated humidity, moisture stains, mildew, and water damage
were observed along the drywall in the following areas:
Central hallway, upper and lower floors: a severe roof leak has resulted in significant water damage to these areas of the facility.
Substantial micro-mold growth and the growth of both plants and macro-fungi was observed. Additional growth is presumed to be
present within the walls, floors, and attic spaces in this area.
Third Floor loft: moisture stains and mold/mildew odors were observed in this area.
Based on the apparent extent of fungal growth (more than 30 square feet), the fungal growth must be abated by a qualified fungal
growth remediation contractor. The cost to retain a consultant to conduct an extensive fungal growth survey and to recommend clean-
up methods and repairs is included in the cost tables. A cost allowance to address the roof and replace the affected areas of fungal
growth is also included.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
4
www.EMGcorp.com p 800.733.0660
The following study is recommended.
The central hallway is in very poor condition due to water infiltration. The structure in this area has potentially been rendered unsound
from water damage. A professional engineer must be retained to analyze the existing condition, provide recommendations and, if
necessary, estimate the scope and cost of any required repairs. The cost of this study is included in the cost tables. A cost allowance
to repair structural damage is also included in the cost tables.
There are a number of unresolved Fire Code violations. See Section 7.6 for descriptions and comments.
1.4. Opinions of Probable Cost
Cost estimates are attached at the front of this report (following the cover page).
These estimates are based on Invoice or Bid Document/s provided either by the Owner/facility and construction costs developed by
construction resources such as R.S. Means and Marshall & Swift, EMG’s experience with past costs for similar properties, city cost
indexes, and assumptions regarding future economic conditions.
Opinions of probable costs should only be construed as preliminary, order of magnitude budgets. Actual costs most probably will vary
from the consultant’s opinions of probable costs depending on such matters as type and design of suggested remedy, quality of
materials and installation, manufacturer and type of equipment or system selected, field conditions, whether a physical deficiency is
repaired or replaced in whole, phasing of the work (if applicable), quality of contractor, quality of project management exercised, market
conditions, and whether competitive pricing is solicited, etc. ASTM E2018-08 recognizes that certain opinions of probable costs cannot
be developed within the scope of this guide without further study. Opinions of probable cost for further study should be included in the
FCA.
1.4.1. Methodology
Based upon site observations, research, and judgment, along with referencing Expected Useful Life (EUL) tables from various industry
sources, EMG opines as to when a system or component will most probably necessitate replacement. Accurate historical replacement
records, if provided, are typically the best source of information. Exposure to the elements, initial quality and installation, extent of use,
the quality and amount of preventive maintenance exercised, etc., are all factors that impact the effective age of a system or
component. As a result, a system or component may have an effective age that is greater or less than its actual chronological age.
The Remaining Useful Life (RUL) of a component or system equals the EUL less its effective age. Projections of Remaining Useful Life
(RUL) are based on continued use of the Property similar to the reported past use. Significant changes in occupants and/or usage may
affect the service life of some systems or components.
Where quantities could not be derived from an actual take-off, lump sum costs or allowances are used. Estimated costs are based on
professional judgment and the probable or actual extent of the observed defect, inclusive of the cost to design, procure, construct and
manage the corrections.
1.4.2. Immediate Repairs
Immediate repairs are opinions of probable costs that require immediate action as a result of: (1) material existing or potential unsafe
conditions, (2) material building or fire code violations, or (3) conditions that, if not addressed, have the potential to result in, or
contribute to, critical element or system failure within one year or will most probably result in a significant escalation of its remedial cost.
1.4.3. Replacement Reserves
Replacement Reserves are for recurring probable expenditures, which are not classified as operation or maintenance expenses. The
replacement reserves should be budgeted for in advance on an annual basis. Replacement Reserves are reasonably predictable both
in terms of frequency and cost. However, Replacement Reserves may also include components or systems that have an
indeterminable life but, nonetheless, have a potential for failure within an estimated time period.
Replacement Reserves exclude systems or components that are estimated to expire after the reserve term and are not considered
material to the structural and mechanical integrity of the subject property. Furthermore, systems and components that are not deemed
to have a material effect on the use of the Property are also excluded. Costs that are caused by acts of God, accidents, or other
occurrences that are typically covered by insurance, rather than reserved for, are also excluded.
Replacement costs are solicited from ownership/property management, EMG’s discussions with service companies, manufacturers'
representatives, and previous experience in preparing such schedules for other similar facilities. Costs for work performed by the
ownership’s or property management’s maintenance staff are also considered.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
5
www.EMGcorp.com p 800.733.0660
EMG’s reserve methodology involves identification and quantification of those systems or components requiring capital reserve funds
within the assessment period. The assessment period is defined as the effective age plus the reserve term. Additional information
concerning system’s or component’s respective replacement costs (in today's dollars), typical expected useful lives, and remaining
useful lives were estimated so that a funding schedule could be prepared. The Replacement Reserves Schedule presupposes that all
required remedial work has been performed or that monies for remediation have been budgeted for items defined in the Immediate
Repair Cost Estimate.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
6
www.EMGcorp.com p 800.733.0660
2. Purpose and Scope
2.1. Purpose
EMG was retained by the client to render an opinion as to the Property’s current general physical condition on the day of the site visit.
Based on the observations, interviews and document review outlined below, this report identifies significant deferred maintenance
issues, existing deficiencies, and material code violations of record at municipal offices, which affect the Property’s use. Opinions are
rendered as to its structural integrity, building system condition and the Property’s overall condition. The report also notes building
systems or components that have realized or exceeded their typical expected useful lives.
CONDITIONS:
The physical condition of building systems and related components are typically defined as being in one of five conditions: Excellent,
Good, Fair, Poor, Failed or a combination thereof. For the purposes of this report, the following definitions are used:
Excellent = New or very close to new; component or system typically has been installed within the past year, sound and
performing its function. Eventual repair or replacement will be required when the component or system either
reaches the end of its useful life or fails in service.
Good = Satisfactory as-is. Component or system is sound and performing its function, typically within the first third of its
lifecycle. However, it may show minor signs of normal wear and tear. Repair or replacement will be required
when the component or system either reaches the end of its useful life or fails in service.
Fair = Showing signs of wear and use but still satisfactory as-is, typically near the median of its estimated useful life.
Component or system is performing adequately at this time but may exhibit some signs of wear, deferred
maintenance, or evidence of previous repairs. Repair or replacement will be required due to the component or
system’s condition and/or its estimated remaining useful life.
Poor = Component or system is significantly aged, flawed, functioning intermittently or unreliably; displays obvious
signs of deferred maintenance; shows evidence of previous repair or workmanship not in compliance with
commonly accepted standards; has become obsolete; or exhibits an inherent deficiency. The present condition
could contribute to or cause the deterioration of contiguous elements or systems. Either full component
replacement is needed or repairs are required to restore to good condition, prevent premature failure, and/or
prolong useful life.
Failed
= Component or system has ceased functioning or performing as intended. Replacement, repair, or other
significant corrective action is recommended or required.
Not Applicable
= Assigning a condition does not apply or make logical sense, most commonly due to the item in question not
being present.
FORMAT OF THE BODY OF THE REPORT:
Throughout sections 5 through 9 of this report, each report section will typically contain three subsections organized in the following
sequence:
A descriptive table (and/or narrative), which identifies the components assessed, their condition, and other key data points.
A simple bulleted list of Anticipated Lifecycle Replacements, which lists components and assets typically in Excellent, Good, or Fair
condition at the time of the assessment but that will require replacement or some other attention once aged past their estimated
useful life. These listed components are typically included in the associated inventory database with costs identified and budgeted
beyond the first several years.
A bulleted cluster of Actions/Comments, which include more detailed narratives describing deficiencies, recommended repairs, and
short term replacements. The assets and components associated with these bullets are/were typically problematic and in Poor or
Failed condition at the time of the assessment, with corresponding costs included within the first few years.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
7
www.EMGcorp.com p 800.733.0660
PLAN TYPES:
Each line item in the cost database is assigned a Plan Type, which is the primary reason or rationale for the recommended
replacement, repair, or other corrective action. This is the “why” part of the equation. A cost or line item may commonly have more
than one applicable Plan Type; however, only one Plan Type will be assigned based on the “best” fit, typically the one with the greatest
significance. The following Plan Types are listed in general weighted order of importance:
Safety = An observed or reported unsafe condition that if left unaddressed could result in an injury; a system
or component that presents a potential liability risk.
Performance/Integrity = Component or system has failed, is almost failing, performs unreliably, does not perform as
intended, and/or poses a risk to overall system stability.
Accessibility = Does not meet ADA, UFAS, and/or other handicap accessibility requirements.
Environmental = Improvements to air or water quality, including removal of hazardous materials from the building or
site.
Modernization/Adaptation
= Conditions, systems, or spaces that need to be upgraded in appearance or function to meet current
standards, facility usage, or client/occupant needs.
Lifecycle/Renewal
= Any component or system in which future repair or replacement is anticipated beyond the next
several years and/or is of minimal substantial early-term consequence.
2.2. Scope
The standard scope of the Facility Condition Assessment includes the following:
Visit the Property to evaluate the general condition of the building and site improvements, review available construction documents in
order to familiarize ourselves with, and be able to comment on, the in-place construction systems, life safety, mechanical, electrical,
and plumbing systems, and the general built environment.
Identify those components that are exhibiting deferred maintenance issues and provide cost estimates for Immediate Costs and
Replacement Reserves based on observed conditions, maintenance history and industry standard useful life estimates. This will
include the review of documented capital improvements completed within the last five-year period and work currently contracted for, if
applicable.
Provide a full description of the Property with descriptions of in-place systems and commentary on observed conditions.
Provide a general statement of the subject Property’s compliance to Title III of the Americans with Disabilities Act. This will not
constitute a full ADA survey, but will help identify exposure to issues and the need for further review.
Perform a limited assessment of accessible areas of the building(s) for the presence of fungal growth, conditions conducive to fungal
growth, and/or evidence of moisture. EMG will also interview Project personnel regarding the presence of any known or suspected
fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Potentially affected areas will be photographed.
Sampling will not be considered in routine assessments.
List the current utility service providers.
Review maintenance records and procedures with the in-place maintenance personnel.
Observe a representative sample of the interior spaces/units, including vacant spaces/units, in order to gain a clear understanding of
the property’s overall condition. Other areas to be observed include the exterior of the property, the roofs, interior common areas,
and the significant mechanical, electrical and elevator equipment rooms.
Provide recommendations for additional studies, if required, with related budgetary information.
Provide an Executive Summary at the beginning of this report.
Prepare a mechanical equipment inventory list.
2.3. Personnel Interviewed
The management staff was interviewed for specific information relating to the physical property, available maintenance procedures,
historical performance of key building systems and components, available drawings and other documentation. The following personnel
from the facility and government agencies were interviewed in the process of conducting the FCA:
Name and Title Organization Phone Number
Peter Ratos
Building Code Official City of Yorkville 630.553.8574
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
8
www.EMGcorp.com p 800.733.0660
The FCA was performed with the assistance of Peter Ratos, Building Code Official, City of Yorkville, the onsite Point of Contact (POC),
who was cooperative and provided information that appeared to be accurate based upon subsequent site observations. The onsite
contact is completely knowledgeable about the subject property and answered most questions posed during the interview process. The
POC’s involvement with the property has spanned the past 6 years.
2.4. Documentation Reviewed
Prior to the FCA, relevant documentation was requested that could aid in the knowledge of the subject property’s physical
improvements, extent and type of use, and/or assist in identifying material discrepancies between reported information and observed
conditions. The review of submitted documents does not include comment on the accuracy of such documents or their preparation,
methodology, or protocol. The Documentation Request Form is provided in Appendix E.
2.5. Pre-Survey Questionnaire
A Pre-Survey Questionnaire was sent to the POC prior to the site visit. The questionnaire is included in Appendix E. Information
obtained from the questionnaire has been used in preparation of this report.
2.6. Weather Conditions
5/17/17: Clear to partly cloudy, with temperatures in the 70s (°F) and moderate winds.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
9
www.EMGcorp.com p 800.733.0660
3. Accessibility and Property Research
3.1. ADA Accessibility
Generally, Title III of the Americans with Disabilities Act (ADA) prohibits discrimination by entities to access and use of “areas of public
accommodations” and “commercial facilities” on the basis of disability. Regardless of its age, these areas and facilities must be
maintained and operated to comply with the Americans with Disabilities Act Accessibility Guidelines (ADAAG).
Buildings completed and occupied after January 26, 1992 are required to comply fully with the ADAAG. Existing facilities constructed
prior to this date are held to the lesser standard of compliance to the extent allowed by structural feasibility and the financial resources
available. As an alternative, a reasonable accommodation pertaining to the deficiency must be made.
During the FCA, a limited visual observation for ADA accessibility compliance was conducted. The scope of the visual observation was
limited to those areas set forth in EMG’s Abbreviated Accessibility Checklist provided in Appendix D of this report. It is understood by
the Client that the limited observations described herein does not comprise a full ADA Compliance Survey, and that such a survey is
beyond the scope of EMG’s undertaking. Only a representative sample of areas was observed and, other than as shown on the
Abbreviated Accessibility Checklist, actual measurements were not taken to verify compliance.
The facility does not appear to be accessible with Title III of the Americans with Disabilities Act. Elements as defined by the ADAAG
that are not accessible as stated within the priorities of Title III, are as follows:
Parking
Adequate number of designated parking stalls and signage for vans are not provided.
Paths of Travel
Door thresholds do not allow for wheelchair access
Restrooms.
Restrooms do not meet any ADA accessibility criteria.
A full ADA Compliance Survey may reveal additional aspects of the property that are not in compliance.
Corrections of these conditions should be addressed from a liability standpoint, but are not necessarily code violations. The Americans
with Disabilities Act Accessibility Guidelines concern civil rights issues as they pertain to the disabled and are not a construction code,
although many local jurisdictions have adopted the Guidelines as such. Because this facility is currently unused and no major
renovations are currently planned, the cost to address the achievable items noted above is not included in the cost tables.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
10
www.EMGcorp.com p 800.733.0660
4. Existing Building Assessment
4.1. Unit or Space Types
All 5,000 square feet of the building are currently unoccupied. The facility was previously used as the Yorkville Sherrif’s office and jail.
The spaces are vacant. Primary building areas include: living quarters, the jail/holding area, a garage, office space, and an unfinished
basement.
4.2. Inaccessible Areas or Key Spaces Not Observed
All of the interior spaces were observed in order to gain a clear understanding of the property’s overall condition. Other areas accessed
included the site within the property boundaries, exterior of the property and the roof (observed from the ground). Areas of note that
were either inaccessible or not observed for other reasons are listed in the table below:
A “down unit” or area is a term used to describe a unit or space that cannot be occupied due to poor conditions such as fire damage,
water damage, missing equipment, damaged floor, wall or ceiling surfaces, or other significant deficiencies. There are substantial
portion of the facility that are down, and the entire facility is considered to be a down area.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
11
www.EMGcorp.com p 800.733.0660
5. Site Improvements
5.1. Utilities
The following table identifies the utility suppliers and the condition and adequacy of the services.
Site Utilities
Utility Supplier Condition and Adequacy
Sanitary sewer City of Yorkville Good and Adequate
Storm sewer City of Yorkville Good and Adequate
Domestic water City of Yorkville Good and Adequate
Electric service Commonwealth Edison Good and Adequate
Natural gas service Nicor Gas Good and Adequate
Actions/Comments:
According to the POC, the utilities provided are adequate for the property. There are no unique, onsite utility systems such as
emergency electrical generators, septic systems, water or waste water treatment plants, or propane gas tanks.
5.2. Parking, Paving, and Sidewalks
Item Description
Main Ingress and Egress West Madison Street
Access from South
Additional Entrances NA
Additional Access from NA
Paving and Flatwork
Item Material Last Work Done Condition
Entrance Driveway Apron None -- --
Parking Lot Asphalt 2010 Good
Drive Aisles None -- --
Service Aisles None -- --
Sidewalks Concrete 2010 Good
Curbs Concrete 2010 Good
Site Stairs Concrete 1970 Poor
Pedestrian Ramps None -- --
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
12
www.EMGcorp.com p 800.733.0660
Parking Count
Open Lot Carport Private Garage Subterranean
Garage
Freestanding Parking
Structure
3 - - - -
Total Number of ADA Compliant Spaces 1
Number of ADA Compliant Spaces for Vans 0
Total Parking Spaces 3
Parking Ratio (Spaces/Apartments) NA
Method of Obtaining Parking Count Physical count
Exterior Stairs
Location Material Handrails Condition
East wall of building Concrete stairs None Poor
Anticipated Lifecycle Replacements:
Asphalt seal coating
Asphalt pavement milling and overlaying
Sidewalks
Concrete stairs
Actions/Comments:
The concrete site stairs at the northeast corner of the facility are in poor condition. The steps are spalling and deteriorated.
Replacement of these concrete stairs is recommended.
5.3. Drainage Systems and Erosion Control
Drainage System and Erosion Control
System Exists At Site Condition
Surface Flow ☐ --
Inlets ☒ Fair
Swales ☒ Fair
Detention pond ☐ --
Lagoons ☐ --
Ponds ☐ --
Underground Piping ☒ Fair
Pits ☐ --
Municipal System ☒ Fair
Dry Well ☐ --
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
13
www.EMGcorp.com p 800.733.0660
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
There is no evidence of storm water runoff from adjacent properties. The storm water system appears to provide adequate runoff
capacity. There is no evidence of major ponding or erosion
5.4. Topography and Landscaping
Item Description
Site Topography Slopes moderately down from the south side of the property to the north
property line.
Landscaping
Trees Grass Flower
Beds Planters
Drought
Tolerant
Plants
Decorative
Stone None
☒ ☒ ☐ ☐ ☐ ☐ ☐
Landscaping
Condition Fair
Irrigation
Automatic
Underground Drip Hand Watering None
☐ ☐ ☐ ☒
Irrigation Condition --
Retaining Walls
Type Location Condition
None -- --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The topography and adjacent uses do not appear to present conditions detrimental to the property. There are no significant areas of
erosion.
5.5. General Site Improvements
Property Signage
Property Signage Building mounted
Street Address Displayed? Yes
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
14
www.EMGcorp.com p 800.733.0660
Site and Building Lighting
Site Lighting
None Pole Mounted Bollard Lights Ground
Mounted
Parking Lot
Pole Type
☒ ☐ ☐ ☐ ☐
--
Building Lighting
None Wall Mounted Recessed Soffit
☐ ☒ ☐
Poor
REFUSE DISPOSAL
Refuse Disposal Individual garbage bins
Dumpster Locations Mounting Enclosure Contracted? Condition
NA - vacant None None NA --
Other Site Amenities
Description Location Condition
Playground Equipment None -- --
Tennis Courts None -- --
Basketball Court None -- --
Swimming Pool None -- --
Anticipated Lifecycle Replacements:
Exterior lighting
Actions/Comments:
The exterior lighting fixture is aged. Replacement is recommended.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
15
www.EMGcorp.com p 800.733.0660
6. Building Architectural and Structural Systems
6.1. Foundations
Building Foundation
Item Description Condition
Foundation Concrete foundation walls Fair
Basement and Crawl Space Concrete slab and concrete walls Fair
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
Isolated areas of the foundation systems are exposed, which allows for limited observation. The foundation systems are concealed.
There are no significant signs of settlement, deflection, or movement. The basement walls appear intact and structurally sound.
There is no evidence of movement or water infiltration.
6.2. Superstructure
Building Superstructure
Item Description Condition
Framing / Load-Bearing Walls Conventional wood/metal studs Fair
Ground Floor Raised wood or concrete slab Fair
Upper Floor Framing Wood joists Fair to Poor
Upper Floor Decking Wood or concrete, cast-in-place Fair to Poor
Roof Framing Wood trusses Fair to Poor
Roof Decking Wood boards or plywood Fair to Poor
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The superstructure is exposed in some locations, which allows for limited observation. There is significant evidence of structural
damage due to water intrusion in the central hallway on the First and Second Floors. This condition appears to affect the rafters,
joists, and studs in these areas as well as the floor and roof decking. A Professional Engineer with specific expertise in structural
design and construction in this geographical area must be retained to evaluate the structure and to provide remedial
recommendations consistent with local regulatory and code requirements. Although the estimated cost of repair cannot be accurately
determined without the recommended study, a budgetary cost allowance to repair the affected elements is also included.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
16
www.EMGcorp.com p 800.733.0660
6.3. Roofing
Primary Roof
Type / Geometry Hip Roof Finish Asphalt shingles
Maintenance In-house Staff Roof Age 50 Yrs
Flashing Sheet metal Warranties None
Parapet Copings Exposed copings Roof Drains Gutters and downspouts
Fascia Concrete cornice
Metal panel fascia
Insulation Fiberglass batts
Soffits Exposed Soffits Skylights No
Attics Yes Ponding No
Ventilation Source-1 Gable end vents Leaks Observed Yes
Ventilation Source-2 None Roof Condition Failed
The primary roof is located over the majority of the building. The roof valley at the intersection between the older and newer portions of
the building is clad with a TPO membrane.
Secondary Roof
Type / Geometry Flat Finish Single-ply membrane
Maintenance In-house Staff Roof Age 50 Yrs
Flashing Sheet metal Warranties Unknown
Parapet Copings None Roof Drains Gutters and downspouts
Fascia Metal Panel Insulation Rigid Board
Soffits None Skylights No
Attics None Ponding No
Ventilation Source-1 Power Vents Leaks Observed No
Ventilation Source-2 None Roof Condition Poor
The secondary roof is located at a small area at the south end of the facility.
Anticipated Lifecycle Replacements:
TPO roof membrane
Asphalt shingles
Actions/Comments:
The roof finishes appear to be more than 30 years old. Information regarding roof warranties or bonds was not available. The roofs
are maintained by the in-house maintenance staff.
There is evidence of active roof leaks. There are areas of severe water damage within several areas of the building. The most
severe area of water damage was observed at the central hallway of the facility. The water damage in this area is extensive and
affects the upper and lower levels. All active leaks must be repaired.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
17
www.EMGcorp.com p 800.733.0660
The roof sheathing exhibits signs of significant areas of sagging and visible penetrations. This condition is indicative of substrate
damage. The damaged areas must be repaired or replaced. The cost of this work is included with the roof finish replacement costs.
The roof insulation has significant areas of missing or water damaged materials. This condition is present in several locations, most
notably at the central hallway mentioned above. New insulation must be installed in this area.
6.4. Exterior Walls
Building Exterior Walls
Type Location Condition
Primary Finish Brick veneer Fair to Poor
Secondary Finish Field stone Fair to Poor
Accented with Concrete Fair to Poor
Soffits Exposed Fair
Building sealants (caulking) are located between dissimilar materials, at joints, and around window and door openings.
Anticipated Lifecycle Replacements:
Caulking
Masonry re-pointing
Actions/Comments:
Significant portions of the mortar joints along the brick veneer and stone veneer are cracked at the front elevation, east elevation, and
north elevation of the older portion of the facility. The damaged mortar joints must be cleaned and re-pointed.
The brick masonry has isolated areas of efflorescence at the front elevation of the building. The affected areas of brick masonry
must be cleaned and an efflorescence-checking coating must also be applied to the brick masonry.
6.5. Exterior and Interior Stairs
Building Exterior and Interior Stairs
Type Description Riser Handrail Balusters Condition
Building Exterior Stairs Cast in place concrete Closed None None Poor
Building Interior Stairs Steel-framed with pre-cast
treads Open Metal Metal Poor
Building Interior Stairs Wood-framed Closed Wood None Fair
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The interior metal stairs at the south stairwell have suffered extensive water damage from the active roof leak in this area. The stairs
are severely corroded and will require replacement.
The exterior concrete steps leading to the basement boiler room are spalling and uneven. Replacement of these steps is
recommended.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
18
www.EMGcorp.com p 800.733.0660
6.6. Exterior Windows and Doors
Building Windows
Window Framing Glazing Location Window
Screen Condition
Wood framed, operable Single glaze Throughout building ☐ Poor to Failed
Building Doors
Main Entrance Doors Door Type Condition
Wood, partially or fully glazed Poor
Secondary Entrance Doors Solid core wood Poor
Service Doors None --
Overhead Doors Wood Poor
Anticipated Lifecycle Replacements:
Wooden windows
Glazed doors
Solid door
Overhead door
Actions/Comments:
The windows are antiquated, energy-inefficient units with single-pane glazing. Some of the windows are difficult to open and close
and several of the windows were loose in their sashes. Replacement of the deteriorated windows is recommended.
Several windows were rendered unnecessary as a result of the building renovations. These windows look onto interior structural
elements of the building or have been covered entirely. These interior windows are not included in the replacement costs.
The exterior doors are antiquated and in poor condition. The basement door does not close properly, the upper floor stairwell door
has a cracked pane of glass, and the main entry door has a single pane of glazing. Replacement of all of the exterior doors is
recommended.
6.7. Patio, Terrace, and Balcony
Not applicable. There are no patios, terraces, or balconies.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
19
www.EMGcorp.com p 800.733.0660
7. Building Mechanical and Plumbing Systems
See the Mechanical Equipment List in the Appendices for the quantity, manufacturer’s name, model number, capacity and year of
manufacturer of the major mechanical equipment, if available.
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC)
Building Central Heating System
Primary Heating System Type Hot water boiler
Forced air furnace
Quantity and Capacity of Major Components 1 boiler at 250 MBH (estimated)
1 furnace at 90 MBH
Total Heating Capacity 340 MBH
Heating Fuel Natural gas
Location of Major Equipment Basement
Garage mechanical room
Space Served by System Older portion of building
Newer portion of building
Age Ranges 1930s (estimated)
1978
Condition Poor
Heat Exchanger Condition --
Distribution System
HVAC Water Distribution System Two-pipe
Heating Water Circulation Pump Size and Quantity None
Pump Condition --
Air Distribution System NA
Quantity and Capacity of Air Handlers NA
Location of Air Handlers --
Large Spaces the Larger Dedicated AHU’s Serve NA
Age of Air Handlers NA
Air Handler Condition --
Terminal Units Radiators
Quantity and Capacity of Terminal Units Five cast-iron radiators
Location of Terminal Units Throughout older portion of building
Spaces Served by Terminal Units Older portion of building
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
20
www.EMGcorp.com p 800.733.0660
Distribution System
Terminal Unit Condition Poor
Controls and Ventilation
HVAC Control System Individual non-programmable thermostats/controls
HVAC Control System Condition Poor
Building Ventilation Natural ventilation only
Ventilation System Condition Fair
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The HVAC systems are maintained by the in-house staff. It is unknown whether records of the installation, maintenance, upgrades,
and replacement of the HVAC equipment at the property have been maintained.
Approximately 50 percent of the HVAC equipment is original. The HVAC equipment varies in age. All of the equipment is antiquated.
HVAC equipment is replaced on an "as needed" basis.
The HVAC equipment is non-functional. The property management staff was interviewed about the historical and recent performance
of the equipment and systems. The systems are antiquated and the management staff stated that the systems are unused. The
facility is vacant and the systems are not necessary. The facility is unused and there are no immediate plans to renovate the building
or restore the facility to a functional state. Replacement of the HVAC components is not recommended.
7.2. Building Plumbing and Domestic Hot Water
Building Plumbing System
Type Description Condition
Water Supply Piping Copper and galvanized iron Fair to poor
Waste/Sewer Piping Cast iron Fair
Vent Piping Cast iron Fair
Water Meter Location Basement
Domestic Water Heaters or Boilers
Components Water Heater
Fuel Natural gas
Quantity and Input Capacity 1 unit at 45 MBH
Storage Capacity 40 gallons
Boiler or Water Heater Condition Poor
Supplementary Storage Tanks? Yes
Storage Tank Quantity and Volume 2 at 30 gallons each
Quantity of Storage Tanks 0
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
21
www.EMGcorp.com p 800.733.0660
Domestic Water Heaters or Boilers
Storage Tank Condition --
Domestic Hot Water Circulation Pumps (3 HP and over) No
Adequacy of Hot Water Unknown
Adequacy of Water Pressure Unknown
Plumbing Fixtures
Water Closets Commercial and residential
Toilet (Water Closet) Flush Rating 1.6 to 3.5 GPF
Common Area Faucet Nominal Flow Rate 2.0 GPM
Condition Poor
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
Most of the domestic water lines are galvanized iron original to the 1970s renovation. The plumbing system is currently unused and
has not been functional for a significant period of time. It is quite common for galvanized iron piping to develop problems due to long-
term corrosion with thinning walls and/or interior mineral deposit accumulation, especially once it has aged 40 or 50 years. As such,
EMG recommends replacing all the plumbing supply lines with copper. The facility is unused and there are no immediate plans to
renovate the building or restore the facility to a functional state. Replacement of the domestic plumbing components is not
recommended.
The restroom accessories and fixtures appear outdated and exhibit significant evidence of heavy wear or damage. The plumbing
fixtures in the First Floor restroom, except for the toilet, are missing. The facility is unused and there are no immediate plans to
renovate the building or restore the facility to a functional state. Replacement of the plumbing fixtures is not recommended.
7.3. Building Gas Distribution
Gas service is supplied from the gas main on the adjacent public street. The gas meter and regulator is located along the exterior wall
of the building. The gas distribution piping within the building is malleable steel (black iron).
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The pressure and quantity of gas appear to be adequate.
The gas meters and regulators appear to be functioning adequately and will require routine maintenance.
Only limited observation of the gas distribution piping can be made due to hidden conditions.
7.4. Building Electrical
Building Electrical Systems
Electrical Lines Overhead Transformer Pole-mounted
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
22
www.EMGcorp.com p 800.733.0660
Building Electrical Systems
Main Service Size 200 Amps Volts 120/208 Volt, three-phase
Meter and Panel Location Basement Branch Wiring Copper
Conduit Metallic Step-Down
Transformers? No
Security / Surveillance
System? No Building Intercom
System? No
Lighting Fixtures Incandescent and T-12
Main Distribution Condition Poor
Secondary Panel and
Transformer Condition Poor
Lighting Condition Poor
Building Emergency System
Size None Fuel NA
Generator / UPS Serves NA Tank Location NA
Testing Frequency NA Tank Type NA
Generator / UPS Condition --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The onsite electrical systems up to the meters are owned and maintained by the respective utility company.
The electrical service and capacity appear to be adequate for the property’s demands.
The panels and wiring are a mix of 1978 components and 1950s components. Despite the age of the electrical components, because
the facility is unused and there are no immediate plans to renovate the building or restore the facility to a functional state, an upgrade
of the electrical systems is not recommended.
The light fixtures throughout a portion of the facility utilize older, inefficient T-12 lamps. The facility is unused and there are no
immediate plans to renovate the building or restore the facility to a functional state, an upgrade of the lighting fixtures is not
recommended
7.5. Building Elevators and Conveying Systems
Not applicable. There are no elevators or conveying systems.
7.6. Fire Protection and Security Systems
Item Description
Type None
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
23
www.EMGcorp.com p 800.733.0660
Item Description
Type None
Fire Alarm System
Central Alarm Panel ☐ Battery-Operated Smoke
Detectors ☐ Alarm Horns ☐
Annunciator Panels ☐ Hard-Wired Smoke
Detectors ☐ Strobe Light Alarms ☐
Pull Stations ☐ Emergency Battery-Pack
Lighting ☒ Illuminated EXIT Signs ☐
Alarm System
Condition Failed
Sprinkler System
None ☒ Standpipes ☐ Backflow Preventer ☐
Hose Cabinets ☐ Fire Pumps ☐ Siamese Connections ☐
Suppression
Condition Fair
Central Alarm Panel
System
Location of Alarm Panel Installation Date of Alarm Panel
None NA
Fire Extinguishers
Last Service Date Servicing Current?
October, 2010 No
Hydrant Location Adjacent streets
Siamese Location None
Special Systems Kitchen Suppression System ☐Computer Room Suppression System ☐
Anticipated Lifecycle Replacements:
Backup light fixture
Actions/Comments:
The fire extinguishers have not been inspected within the last year. A qualified fire equipment contractor must inspect and service
the fire extinguishers.
Fire extinguishers appear to be missing at many locations. New fire extinguishers must be installed at all required locations
immediately.
The only backup light fixture at the building is in the central hallway on the Second Floor. The light fixture appears to be failed.
The fire alarm systems are largely nonexistent and are not up to current standards. The system lacks smoke detectors, carbon
monoxide detectors, strobe alarms, pull stations, and older non-illuminated exit signs. The facility is unused and there are no
immediate plans to renovate the building or restore the facility to a functional state. An upgrade of the fire alarm system is not
recommended
The building is not protected by fire suppression. Due to its construction date, the facility is most likely “grandfathered” by code and
the installation of fire sprinklers not required until major renovations are performed. The facility is unused and there are no immediate
plans to renovate the building or restore the facility to a functional state. Installation of a fire suppression system is not recommended
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
24
www.EMGcorp.com p 800.733.0660
8. Interior Spaces
8.1. Interior Finishes
All 5,000 square feet of the building are currently unoccupied. The facility was previously used as the Yorkville Sherrif’s office and jail.
The spaces are vacant. Primary building areas include: living quarters, the jail/holding area, a garage, office space, and an unfinished
basement.
The following table generally describes the locations and typical conditions of the interior finishes within the facility:
Typical Floor Finishes
Floor Finish Locations General Condition
Unfinished (wood) Older area of building on First and Second Floors Poor
Carpet Second Floor central hallway and newer area of
Second Floor Poor to Failed
Vinyl tile First Floor hallway, Second Floor restroom and
kitchen Poor
Linoleum Old kitchen area Poor to Failed
Concrete Garage, jail area, basement Poor
Typical Wall Finishes
Wall Finish Locations General Condition
Painted drywall Newer area of building Poor
Painted plaster Older area of building Poor
Unfinished Garage, basement Poor
Painted concrete Jail area Poor
Wooden wainscoting Third Floor of old section of building Poor
Typical Ceiling Finishes
Ceiling Finish Locations General Condition
Painted drywall Some areas of basement, upper floor restrooms,
stairwells Poor
Painted plaster Small vault, upper floor Poor
Painted concrete Jail area Poor
Unfinished Basement Poor
Wooden wainscoting Third Floor of old section of building Poor
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
25
www.EMGcorp.com p 800.733.0660
Interior Doors
Item Type Condition
Interior Doors Hollow core Poor
Door Framing Wood Poor
Fire Doors No Poor
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The interior areas were last partially renovated around 2000.
The interior finishes have mostly been removed from the facility. The remaining interior finishes area aged, worn, and generally in
poor to failed condition. The facility is unused and there are no immediate plans to renovate the building or restore the facility to a
functional state. Replacement of the interior finishes is not recommended
The ceilings have significant areas of water-damage in the central hallway and several isolated area of physical damage from
animals on the Third Floor of the old section of the facility and the Second Floor of the newer section of the facility. The damaged
ceiling areas need to be replaced.
There are significant areas of water-damaged and physically damaged wall finishes throughout the building. The most severely
damaged areas are located in the central hallway of the facility. The damaged wall areas need to be replaced.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
26
www.EMGcorp.com p 800.733.0660
9. Other Structures
Not applicable. There are no major accessory structures.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
27
www.EMGcorp.com p 800.733.0660
10. Certification
The City of Yorkville retained EMG to perform this Facility Condition Assessment in connection with its continued operation of Historic
Jail, 111 West Madison Street, Yorkville, Illinois, the “Property”. It is our understanding that the primary interest of the City of Yorkville
is to locate and evaluate materials and building system defects that might significantly affect the value of the property and to determine
if the present Property has conditions that will have a significant impact on its continued operations.
The conclusions and recommendations presented in this report are based on the brief review of the plans and records made available
to our Project Manager during the site visit, interviews of available property management personnel and maintenance contractors
familiar with the Property, appropriate inquiry of municipal authorities, our Project Manager’s walk-through observations during the site
visit, and our experience with similar properties.
No testing, exploratory probing, dismantling or operating of equipment or in depth studies were performed unless specifically required
under Section 2 of this report. This assessment did not include engineering calculations to determine the adequacy of the Property’s
original design or existing systems. Although walk-through observations were performed, not all areas were observed (See Section 4.2
for areas observed). There may be defects in the Property, which were in areas not observed or readily accessible, may not have been
visible, or were not disclosed by management personnel when questioned. The report describes property conditions at the time that
the observations and research were conducted.
This report has been prepared on behalf of and exclusively for the use of the City of Yorkville for the purpose stated within Section 2 of
this report. The report, or any excerpt thereof, shall not be used by any party other than the City of Yorkville or for any other purpose
than that specifically stated in our agreement or within Section 2 of this report without the express written consent of EMG.
Any reuse or distribution of this report without such consent shall be at the City of Yorkville and the recipient’s sole risk, without liability
to EMG.
Prepared by: Kevin Koranda,
Project Manager
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
28
www.EMGcorp.com p 800.733.0660
11. Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: EMG Accessibility Checklist
Appendix D: Pre-Survey Questionnaire
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
HISTORIC JAIL EMG PROJECT NO: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
PHOTO
#1:
FRONT ELEVATION PHOTO
#2:
EAST ELEVATION
PHOTO
#3:
NORTH ELEVATION PHOTO
#4:
WEST ELEVATION
PHOTO
#5:
CURB CUTAWAY PHOTO
#6:
SIDEWALK
HISTORIC JAIL EMG PROJECT NO: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
PHOTO
#7:
ACCESSIBLE PARKING SPACE PHOTO
#8:
CORNICE AND SHINGLES
PHOTO
#9:
ASPHALT SHINGLE ROOF,
DETERIORATING
PHOTO
#10:
EFFLORESCENCE AND
DETERIORATED MORTAR
PHOTO
#11:
MISSING MORTAR PHOTO
#12:
MISSING MORTAR
HISTORIC JAIL EMG PROJECT NO: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
PHOTO
#13:
WINDOW, WOOD FRAME, SINGLE
PANE
PHOTO
#14:
GARAGE DOOR, WOOD
PHOTO
#15:
FOUNDATION WALL, MISSING
MORTAR, LOOSE STONES
PHOTO
#16:
EFFLORESCENCE AND MISSING
MORTAR
PHOTO
#17:
CHIMNEY, DETERIORATING PHOTO
#18:
CONDENSING UNIT
HISTORIC JAIL EMG PROJECT NO: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
PHOTO
#19:
RADIATOR PHOTO
#20:
EXPANSION TANKS, JAIL AREA
PHOTO
#21:
EXTINGUISHER PHOTO
#22:
LOAD CENTER
PHOTO
#23:
SANITARY PIPING PHOTO
#24:
DOMESTIC WATER HEATER
HISTORIC JAIL EMG PROJECT NO: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
PHOTO
#25:
FURNACE PHOTO
#26:
CIRCUIT BREAKER
PHOTO
#27:
WATER SOFTENER PHOTO
#28:
BOILER
PHOTO
#29:
EXPANSION TANK PHOTO
#30:
OLD KITCHEN AREA
HISTORIC JAIL EMG PROJECT NO: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
PHOTO
#31:
METAL STAIRS, JAIL PHOTO
#32:
CELLS
PHOTO
#33:
CELL TOILET PHOTO
#34:
CELL INTERIOR
PHOTO
#35:
CENTRAL HALLWAY PHOTO
#36:
WATER DAMAGE, CENTRAL
HALLWAY
HISTORIC JAIL EMG PROJECT NO: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
PHOTO
#37:
SOUTH STAIRS PHOTO
#38:
WATER DAMAGE, SECOND FLOOR,
SOUTH STAIRS
PHOTO
#39:
WATER DAMAGE PHOTO
#40:
FUNGAL GROWTH
PHOTO
#41:
GARAGE AREA PHOTO
#42:
GARAGE DOOR
HISTORIC JAIL EMG PROJECT NO: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
PHOTO
#43:
GARAGE DOOR OPENER PHOTO
#44:
GARAGE UTILITY AND STORAGE
AREA
PHOTO
#45:
SECOND FLOOR CENTRAL HALLWAY,
MOSS GROWING FROM CARPET
PHOTO
#46:
SECOND FLOOR CENTRAL HALLWAY,
CEILING
PHOTO
#47:
SECOND FLOOR, NEW WING,
DAMAGED CEILING
PHOTO
#48:
SECOND FLOOR RESTROOM, NEW
WING
HISTORIC JAIL EMG PROJECT NO: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
PHOTO
#49:
SECOND FLOOR OFFICE AREA,
CARPET
PHOTO
#50:
WATER DAMAGED CEILING
PHOTO
#51:
LIVING QUARTERS, RESTROOM PHOTO
#52:
LIVING QUARTERS
PHOTO
#53:
LIVING QUARTERS PHOTO
#54:
FUNGAL GROWTH
HISTORIC JAIL EMG PROJECT NO: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
PHOTO
#55:
LIVING QUARTERS, THIRD FLOOR PHOTO
#56:
LIVING QUARTERS, THIRD FLOOR
PHOTO
#57:
WATER DAMAGE, THIRD FLOOR PHOTO
#58:
BASEMENT
PHOTO
#59:
BASEMENT CONDUIT PHOTO
#60:
CORRUGATED STEEL ARCH FIRST
FLOOR FRAMING
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Historic Jail
Project Number:
122700.17R000-003.322
Source:
Google Earth Pro
On-Site Date:
May 17, 2017
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
Appendix C:
EMG Accessibility Checklist
Page 1 of 4
Date Completed: May 17, 2017
Property Name: Historic Jail
EMG Project Number: 122700.17R000-003.322
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? ✔
2
Have any ADA improvements been made
to the property? ✔ Parking area only
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? ✔
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
✔
5
Is any litigation pending related to ADA
issues? ✔
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
✔
2
Are there sufficient van-accessible parking
spaces available? ✔ None
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
✔
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
✔
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
✔
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
✔
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) ✔
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? ✔
3
Does the width between railings appear at
least 36 inches? ✔
Page 2 of 4
Ramps (cont.) Yes No NA Comments
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
✔
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? ✔
2
If the main entrance is inaccessible, are
there alternate accessible entrances? ✔
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
✔
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? ✔
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? ✔
3
Is there a path of travel that does not
require the use of stairs? ✔
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? ✔
2
Are there visual and audible signals inside
cars indicating floor change? ✔
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? ✔
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? ✔
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? ✔
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? ✔
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? ✔
2
Are pull handles push/pull or lever type?
✔
3
Are there audible and visual fire alarm
devices in the toilet rooms? ✔
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? ✔
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? ✔
6
In unisex toilet rooms, are there safety
alarms with pull cords? ✔
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? ✔
8
Are grab bars provided in toilet stalls?
✔
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? ✔
10
Are sink handles operable with one hand
without grasping, pinching or twisting? ✔
11
Are exposed pipes under sink sufficiently
insulated against contact? ✔
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
✔
Page 4 of 4
Guest Rooms (cont.) Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
✔
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
✔
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. ✔
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
✔
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
✔
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
✔
*Based on visual observation only. The slope was not confirmed through measurements.
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
Appendix D:
Pre-Survey Questionnaire
HISTORIC JAIL EMG PROJECT NO.: 122700.17R000-003.322
www.EMGcorp.com p 800.733.0660
On the day of the site visit, provide EMG's Field Observer access to all of the available documents listed below.
Provide copies if possible.
INFORMATION REQUIRED
1. All available construction documents (blueprints) for
the original construction of the building or for any tenant
improvement work or other recent construction work.
2. A site plan, preferably 8 1/2" X 11", which depicts the
arrangement of buildings, roads, parking stalls, and other
site features.
3. For commercial properties, provide a tenant list which
identifies the names of each tenant, vacant tenant units,
the floor area of each tenant space, and the gross and
net leasable area of the building(s).
4. For apartment properties, provide a summary of the
apartment unit types and apartment unit type quantities,
including the floor area of each apartment unit as
measured in square feet.
5. For hotel or nursing home properties, provide a
summary of the room types and room type quantities.
6. Copies of Certificates of Occupancy, building permits,
fire or health department inspection reports, elevator
inspection certificates, roof or HVAC warranties, or any
other similar, relevant documents.
7. The names of the local utility companies which serve
the property, including the water, sewer, electric, gas,
and phone companies.
8. The company name, phone number, and contact
person of all outside vendors who serve the property,
such as mechanical contractors, roof contractors, fire
sprinkler or fire extinguisher testing contractors, and
elevator contractors.
9. A summary of recent (over the last 5 years) capital
improvement work which describes the scope of the
work and the estimated cost of the improvements.
Executed contracts or proposals for improvements.
Historical costs for repairs, improvements, and
replacements.
10. Records of system and material ages (roof, MEP,
paving, finishes, furnishings).
11. Any brochures or marketing information.
12. Appraisal, either current or previously prepared.
13. Current occupancy percentage and typical turnover
rate records (for commercial and apartment properties).
14. Previous reports pertaining to the physical condition
of property.
15. ADA survey and status of improvements
implemented.
16. Current / pending litigation related to property
condition.
Your timely compliance with this request is greatly appreciated.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
City Hall/Police Department
800 Game Farm Road
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-004.322 September 13, 2017 May 18, 2017
FACILITY CONDITION ASSESSMENT
Immediate Repairs Report
City Hall/Police Department
9/13/2017
Location Name EMG Renamed Item NumberID Cost Description QuantityUnit Unit Cost Subtotal Deficiency Repair Estimate *
City Hall/Police Department 3.1 610281 Accessible Parking, Parking, Designated Stall with Pavement Markings & Signage (Van),2 EA $1,391.50 $2,783 $2,783
City Hall/Police Department 3.1 610289 Accessible Restroom, Restroom, Lavatory Pipe Wraps,7 EA $75.90 $531 $531
City Hall/Police Department 5.2 610309 Parking Lot, Parking Lot, Repair 6275 SF $0.38 $2,381 $2,381
City Hall/Police Department 5.2 610262 Parking Lot, Parking Lot, Repair 11590 SF $0.38 $4,398 $4,398
City Hall/Police Department 5.2 610347 Parking Lot, Parking Lot, Repair 8410 SF $0.38 $3,192 $3,192
City Hall/Police Department 5.5 610260 Exterior Light Pole, Exterior, 135 to 1000 W HID (Fixture, Ballast, & Lamp), Repair 8 EA $2,246.90 $17,975 $17,975
City Hall/Police Department 6.3 610266 Roof, Premium Grade, Replace 14300 SF $5.04 $72,069 $72,069
City Hall/Police Department 6.5 610311 Exterior Stair/Ramp, (per LF of Nosing), Replace 80 LF $8.54 $683 $683
City Hall/Police Department 6.6 610304 Exterior Door, Exterior Door, Repair 7 EA $69.94 $490 $490
City Hall/Police Department 7.1 610273 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 1 EA $6,439.81 $6,440 $6,440
City Hall/Police Department 7.1 610313 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 1 EA $6,439.81 $6,440 $6,440
City Hall/Police Department 7.1 610328 Split System, Split System DX, Air-Cooled, 1 Ton, Replace 1 EA $2,118.94 $2,119 $2,119
City Hall/Police Department 7.1 610297 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 1 EA $6,439.81 $6,440 $6,440
City Hall/Police Department 7.1 610337 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 1 EA $6,439.81 $6,440 $6,440
City Hall/Police Department 7.1 610308 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 1 EA $6,439.81 $6,440 $6,440
City Hall/Police Department 7.1 610336 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 1 EA $6,439.81 $6,440 $6,440
City Hall/Police Department 7.1 610283 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 1 EA $6,439.81 $6,440 $6,440
City Hall/Police Department 7.1 610272 HVAC System, Full Upgrade, Office (per SF),1000 SF $37.86 $37,859 $37,859
City Hall/Police Department 7.2 610332 Water Pumps, 1 to 3 HP, Replace 1 EA $2,993.56 $2,994 $2,994
City Hall/Police Department 7.2 610345 Water Pumps, 1 to 3 HP, Replace 1 EA $2,993.56 $2,994 $2,994
City Hall/Police Department 7.2 610294 Water Pumps, 1 to 3 HP, Replace 1 EA $2,993.56 $2,994 $2,994
City Hall/Police Department 7.2 610317 Water Pumps, 1 to 3 HP, Replace 1 EA $2,993.56 $2,994 $2,994
City Hall/Police Department 8.1 610290 Floor Finishings, Standard Commercial, Medium Traffic, Replace 1500 SF $7.26 $10,884 $10,884
Immediate Repairs Total $212,418
* Location Factor included in totals.
Replacement Reserves Report
City Hall/Police Department
9/13/2017
Location Name
EMG
Renamed
Item
Number
ID Cost Description Lifespan
(EUL)EAge RUL QuantityUnit Unit Cost Subtotal 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036
Deficiency
Repair
Estimate
City Hall/Police Department 3.1 610281 Accessible Parking, Parking, Designated Stall with Pavement Markings & Signage (Van),0 0 0 2 EA $1,391.50 $2,783 $2,783 $2,783
City Hall/Police Department 3.1 610289 Accessible Restroom, Restroom, Lavatory Pipe Wraps,0 0 0 7 EA $75.90 $531 $531 $531
City Hall/Police Department 5.2 610309 Parking Lot, Parking Lot, Repair 5 17 0 6275 SF $0.38 $2,381 $2,381 $2,381 $2,381 $2,381 $9,525
City Hall/Police Department 5.2 610262 Parking Lot, Parking Lot, Repair 5 17 0 11590 SF $0.38 $4,398 $4,398 $4,398 $4,398 $4,398 $17,594
City Hall/Police Department 5.2 610347 Parking Lot, Parking Lot, Repair 5 17 0 8410 SF $0.38 $3,192 $3,192 $3,192 $3,192 $3,192 $12,766
City Hall/Police Department 5.2 610282 Parking Lot, Parking Lot, Repair 25 20 5 8410 SF $3.28 $27,588 $27,588 $27,588
City Hall/Police Department 5.2 610258 Pedestrian Pavement, , Replace 30 17 13 2825 SF $19.82 $55,997 $55,997 $55,997
City Hall/Police Department 5.5 610287 Lighting Fixture, 80 W, Replace 20 17 3 9 EA $256.88 $2,312 $2,312 $2,312
City Hall/Police Department 5.5 610322 Site Signage, Property, Monument/Pylon, Replace/Install 20 12 8 1 EA $8,602.00 $8,602 $8,602 $8,602
City Hall/Police Department 5.5 610260 Exterior Light Pole, Exterior, 135 to 1000 W HID (Fixture, Ballast, & Lamp), Repair 10 17 0 8 EA $2,246.90 $17,975 $17,975 $17,975 $35,950
City Hall/Police Department 6.3 610266 Roof, Premium Grade, Replace 30 30 0 14300 SF $5.04 $72,069 $72,069 $72,069
City Hall/Police Department 6.4 610335 Exterior Wall 10 7 3 200 LF $2.82 $564 $564 $564 $1,128
City Hall/Police Department 6.4 610286 Vinyl Siding, Exterior, 1-2 Stories, Replace 25 17 8 3850 SF $7.81 $30,065 $30,065 $30,065
City Hall/Police Department 6.4 610346 Brick Veneer Exterior Wall, Exterior, 1-2 Stories, Repair 25 17 8 40 SF $41.28 $1,651 $1,651 $1,651
City Hall/Police Department 6.5 610311 Exterior Stair/Ramp, (per LF of Nosing), Replace 0 17 0 80 LF $8.54 $683 $683 $683
City Hall/Police Department 6.6 610321 Window, Double Glazed, 1-2 Stories, 12 SF, Replace 30 17 13 14 EA $555.58 $7,778 $7,778 $7,778
City Hall/Police Department 6.6 610314 Window, Double Glazed, 1-2 Stories, 24 SF, Replace 30 17 13 39 EA $813.20 $31,715 $31,715 $31,715
City Hall/Police Department 6.6 610324 Storefront 30 17 13 40 SF $48.00 $1,920 $1,920 $1,920
City Hall/Police Department 6.6 610304 Exterior Door, Exterior Door, Repair 10 17 0 7 EA $69.94 $490 $490 $490 $979
City Hall/Police Department 6.6 610275 Exterior Door, Exterior Door, Replace 25 17 8 2 EA $1,352.72 $2,705 $2,705 $2,705
City Hall/Police Department 6.6 610291 Exterior Door, Insulated, Exterior Door, Replace 25 17 8 7 EA $1,577.53 $11,043 $11,043 $11,043
City Hall/Police Department 6.6 610327 Overhead Door, 144 SF, Replace 35 17 18 3 EA $4,025.54 $12,077 $12,077 $12,077
City Hall/Police Department 6.6 610318 Garage Door Opener, Belt Drive, 0.5 HP, Replace 15 7 8 3 EA $519.03 $1,557 $1,557 $1,557
City Hall/Police Department 7.1 610334 Elevator, Hydraulic, 1500 to 2500 LB, 2 Floors,30 17 13 1 EA $108,794.40 $108,794 $108,794 $108,794
City Hall/Police Department 7.1 610325 Water Heater, Gas, Commercial, 60 to 120 GAL, Replace 15 4 11 1 EA $10,698.82 $10,699 $10,699 $10,699
City Hall/Police Department 7.1 610263 Hydraulic Pump, Submersible, 20 HP, Replace 15 8 7 1 EA $5,000.00 $5,000 $5,000 $5,000
City Hall/Police Department 7.1 610273 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 15 17 0 1 EA $6,439.81 $6,440 $6,440 $6,440 $12,880
City Hall/Police Department 7.1 610313 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 15 17 0 1 EA $6,439.81 $6,440 $6,440 $6,440 $12,880
City Hall/Police Department 7.1 610328 Split System, Split System DX, Air-Cooled, 1 Ton, Replace 15 17 0 1 EA $2,118.94 $2,119 $2,119 $2,119 $4,238
City Hall/Police Department 7.1 610297 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 15 17 0 1 EA $6,439.81 $6,440 $6,440 $6,440 $12,880
City Hall/Police Department 7.1 610337 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 15 17 0 1 EA $6,439.81 $6,440 $6,440 $6,440 $12,880
City Hall/Police Department 7.1 610308 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 15 17 0 1 EA $6,439.81 $6,440 $6,440 $6,440 $12,880
City Hall/Police Department 7.1 610336 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 15 17 0 1 EA $6,439.81 $6,440 $6,440 $6,440 $12,880
City Hall/Police Department 7.1 610283 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 15 17 0 1 EA $6,439.81 $6,440 $6,440 $6,440 $12,880
City Hall/Police Department 7.1 610259 Split System, Split System DX, Air-Cooled, 5 Ton, Replace 15 8 7 1 EA $6,439.81 $6,440 $6,440 $6,440
City Hall/Police Department 7.1 610306 Exhaust Fan, Centrifugal, 251 to 800 CFM, Replace 15 13 2 1 EA $2,021.87 $2,022 $2,022 $2,022 $4,044
City Hall/Police Department 7.1 610296 Exhaust Fan, Centrifugal, 251 to 800 CFM, Replace 15 13 2 1 EA $2,021.87 $2,022 $2,022 $2,022 $4,044
City Hall/Police Department 7.1 610272 HVAC System, Full Upgrade, Office (per SF),20 20 0 1000 SF $37.86 $37,859 $37,859 $37,859
City Hall/Police Department 7.1 610331 Furnace, Gas, 101 to 150 MBH, Replace 20 17 3 1 EA $5,644.27 $5,644 $5,644 $5,644
City Hall/Police Department 7.1 610265 Furnace, Gas, 101 to 150 MBH, Replace 20 17 3 1 EA $5,644.27 $5,644 $5,644 $5,644
City Hall/Police Department 7.1 610285 Unit Heater, Natural Gas, 26 to 55 MBH, Replace 20 17 3 1 EA $4,281.60 $4,282 $4,282 $4,282
City Hall/Police Department 7.1 610330 Furnace, Gas, 101 to 150 MBH, Replace 20 17 3 1 EA $5,644.27 $5,644 $5,644 $5,644
City Hall/Police Department 7.1 610315 Unit Heater, Natural Gas, 26 to 55 MBH, Replace 20 17 3 1 EA $4,281.60 $4,282 $4,282 $4,282
City Hall/Police Department 7.1 610329 Furnace, Gas, 101 to 150 MBH, Replace 20 17 3 1 EA $5,644.27 $5,644 $5,644 $5,644
City Hall/Police Department 7.1 610343 Furnace, Gas, 101 to 150 MBH, Replace 20 17 3 1 EA $5,644.27 $5,644 $5,644 $5,644
City Hall/Police Department 7.1 610307 Furnace, Gas, 101 to 150 MBH, Replace 20 17 3 1 EA $5,644.27 $5,644 $5,644 $5,644
Location Name
EMG
Renamed
Item
Number
ID Cost Description Lifespan
(EUL)EAge RUL QuantityUnit Unit Cost Subtotal 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036
Deficiency
Repair
Estimate
City Hall/Police Department 7.1 610316 Furnace, Gas, 101 to 150 MBH, Replace 20 17 3 1 EA $5,644.27 $5,644 $5,644 $5,644
City Hall/Police Department 7.1 610270 Unit Heater, Electric, Infrared, 1 to 2 kW, Replace 20 17 3 1 EA $1,095.84 $1,096 $1,096 $1,096
City Hall/Police Department 7.1 610292 Furnace, Gas, 101 to 150 MBH, Replace 20 17 3 1 EA $5,644.27 $5,644 $5,644 $5,644
City Hall/Police Department 7.1 610299 Unit Heater, Electric, Infrared, 3 to 6 kW, Replace 20 17 3 1 EA $1,741.57 $1,742 $1,742 $1,742
City Hall/Police Department 7.1 610312 Transfer Switch, Auto, 600 V, 40 Amp, Replace 18 13 5 1 EA $6,704.24 $6,704 $6,704 $6,704
City Hall/Police Department 7.1 610340 Fire Alarm System, Addressable, Replace 15 13 2 1 EA $20,297.59 $20,298 $20,298 $20,298 $40,595
City Hall/Police Department 7.2 610269 Toilet Partitions, Metal, Overhead Braced, Replace 20 12 8 2 EA $850.00 $1,700 $1,700 $1,700
City Hall/Police Department 7.2 610293 Toilet, , Replace 20 12 8 4 EA $842.97 $3,372 $3,372 $3,372
City Hall/Police Department 7.2 610279 Toilet, One Piece, Replace 20 12 8 2 EA $1,055.15 $2,110 $2,110 $2,110
City Hall/Police Department 7.2 610319 Urinal, Vitreous China, Replace 20 12 8 3 EA $1,193.44 $3,580 $3,580 $3,580
City Hall/Police Department 7.2 610303 Lavatory, Enameled Steel, Replace 20 12 8 7 EA $353.05 $2,471 $2,471 $2,471
City Hall/Police Department 7.2 610268 Sink, Plastic, Replace 20 12 8 1 EA $575.99 $576 $576 $576
City Hall/Police Department 7.2 610264 Bathtub/Shower, Fiberglass, Replace 20 12 8 2 EA $2,599.44 $5,199 $5,199 $5,199
City Hall/Police Department 7.2 610288 Drinking Fountain, Refrigerated, Replace 10 8 2 3 EA $1,257.51 $3,773 $3,773 $3,773 $7,545
City Hall/Police Department 7.2 610339 Emergency Eye Wash, , Replace 15 9 6 1 EA $1,417.04 $1,417 $1,417 $1,417
City Hall/Police Department 7.2 610332 Water Pumps, 1 to 3 HP, Replace 15 17 0 1 EA $2,993.56 $2,994 $2,994 $2,994 $5,987
City Hall/Police Department 7.2 610345 Water Pumps, 1 to 3 HP, Replace 15 17 0 1 EA $2,993.56 $2,994 $2,994 $2,994 $5,987
City Hall/Police Department 7.2 610294 Water Pumps, 1 to 3 HP, Replace 15 17 0 1 EA $2,993.56 $2,994 $2,994 $2,994 $5,987
City Hall/Police Department 7.2 610317 Water Pumps, 1 to 3 HP, Replace 15 17 0 1 EA $2,993.56 $2,994 $2,994 $2,994 $5,987
City Hall/Police Department 7.4 610276 Distribution Panel, 208 Y, 120 V, 100 Amp, Replace 30 17 13 3 EA $5,079.93 $15,240 $15,240 $15,240
City Hall/Police Department 7.4 610320 Distribution Panel, 208 Y, 120 V, 100 Amp, Replace 30 17 13 5 EA $5,079.93 $25,400 $25,400 $25,400
City Hall/Police Department 7.4 610302 Distribution Panel, 208 Y, 120 V, 800 Amp, Replace 30 17 13 1 EA $13,423.81 $13,424 $13,424 $13,424
City Hall/Police Department 7.4 610261 Lighting & Branch Wiring System, Full Upgrade, Office (per SF),25 17 8 18568 SF $9.24 $171,605 $171,605 $171,605
City Hall/Police Department 7.4 610305 Generator, Diesel, 65 to 125 kW, Replace 25 13 12 1 EA $113,996.22 $113,996 $113,996 $113,996
City Hall/Police Department 7.4 610278 Ceiling Fan, Residential, Replace 15 12 3 10 EA $354.11 $3,541 $3,541 $3,541 $7,082
City Hall/Police Department 7.6 610333 Fire Extinguisher, , Replace 15 8 7 6 EA $356.54 $2,139 $2,139 $2,139
City Hall/Police Department 7.6 610344 Emergency Exit System, 2 Light w/ Battery, Replace 10 6 4 2 EA $1,227.87 $2,456 $2,456 $2,456 $4,911
City Hall/Police Department 7.6 610323 Emergency Exit System, w/ Battery, Replace 10 6 4 10 EA $418.95 $4,190 $4,190 $4,190 $8,379
City Hall/Police Department 7.6 610271 Defibrillator, Cabinet Mounted, Replace 5 3 2 1 EA $1,409.50 $1,410 $1,410 $1,410 $1,410 $1,410 $5,638
City Hall/Police Department 8.1 610295 Interior Door, , Replace 15 12 3 4 EA $762.99 $3,052 $3,052 $3,052 $6,104
City Hall/Police Department 8.1 610338 Interior Door, Painted/Stained, Fully Glazed, Interior Door, Replace 15 12 3 3 EA $1,982.31 $5,947 $5,947 $5,947 $11,894
City Hall/Police Department 8.1 610326 Interior Door, , Replace 20 12 8 11 EA $1,649.06 $18,140 $18,140 $18,140
City Hall/Police Department 8.1 610342 Interior Door, Solid Core, Painted/Stained, Interior Door, Replace 20 12 8 47 EA $1,423.11 $66,886 $66,886 $66,886
City Hall/Police Department 8.1 610280 Interior Walls, Interior Wall, Repair 8 1 7 36208 SF $1.42 $51,531 $51,531 $51,531 $103,062
City Hall/Police Department 8.1 610298 Floor Finishings, , Replace 15 10 5 1856 SF $4.80 $8,910 $8,910 $8,910
City Hall/Police Department 8.1 610290 Floor Finishings, Standard Commercial, Medium Traffic, Replace 10 17 0 1500 SF $7.26 $10,884 $10,884 $10,884 $21,769
City Hall/Police Department 8.1 610274 Ceilings, Ceiling, Repair 10 8 2 12070 SF $1.94 $23,375 $23,375 $23,375 $46,750
City Hall/Police Department 8.1 610348 Ceilings, , Replace 20 8 12 12070 SF $3.11 $37,550 $37,550 $37,550
City Hall/Police Department 8.1 610300 Refrigerator, Residential, 14-18 CF,15 9 6 2 EA $956.04 $1,912 $1,912 $1,912
City Hall/Police Department 8.1 610284 Range, Gas, Residential,15 9 6 1 EA $768.11 $768 $768 $768
City Hall/Police Department 8.1 610277 Kitchen Cabinet, Base and Wall Section, Wood, Replace 20 12 8 16 LF $467.63 $7,482 $7,482 $7,482
Totals, Unescalated $212,418 $0 $52,898 $71,971 $6,645 $53,174 $4,097 $66,520 $338,746 $0 $39,321 $10,699 $180,103 $260,831 $6,645 $120,674 $0 $25,751 $24,617 $0 $1,475,110
Totals, Escalated (3.0% inflation, compounded annually)$212,418 $0 $56,120 $78,644 $7,479 $61,643 $4,892 $81,811 $429,113 $0 $52,844 $14,810 $256,783 $383,039 $10,052 $188,007 $0 $42,562 $41,908 $0 $1,922,126
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1. Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
1.3. Special Issues and Follow-Up Recommendations ...................................................................... 3
1.4. Opinions of Probable Cost .......................................................................................................... 3
1.4.1. Methodology ................................................................................................................................ 4
1.4.2. Immediate Repairs ...................................................................................................................... 4
1.4.3. Replacement Reserves ............................................................................................................... 4
2. Purpose and Scope .............................................................................................................................. 5
2.1. Purpose ....................................................................................................................................... 5
2.2. Scope .......................................................................................................................................... 6
2.3. Personnel Interviewed ................................................................................................................. 7
2.4. Documentation Reviewed ........................................................................................................... 7
2.5. Pre-Survey Questionnaire ........................................................................................................... 7
2.6. Weather Conditions ..................................................................................................................... 7
3. Accessibility and Property Research ................................................................................................. 8
3.1. ADA Accessibility ........................................................................................................................ 8
4. Existing Building Assessment ............................................................................................................ 9
4.1. Unit or Space Types .................................................................................................................... 9
4.2. Inaccessible Areas or Key Spaces Not Observed ...................................................................... 9
5. Site Improvements ............................................................................................................................. 10
5.1. Utilities ....................................................................................................................................... 10
5.2. Parking, Paving, and Sidewalks ................................................................................................ 10
5.3. Drainage Systems and Erosion Control .................................................................................... 11
5.4. Topography and Landscaping ................................................................................................... 12
5.5. General Site Improvements ....................................................................................................... 12
6. Building Architectural and Structural Systems ............................................................................... 14
6.1. Foundations ............................................................................................................................... 14
6.2. Superstructure ........................................................................................................................... 14
6.3. Roofing ...................................................................................................................................... 14
6.4. Exterior Walls ............................................................................................................................ 15
6.5. Exterior and Interior Stairs ......................................................................................................... 16
6.6. Exterior Windows and Doors ..................................................................................................... 16
6.7. Patio, Terrace, and Balcony ...................................................................................................... 17
7. Building Mechanical and Plumbing Systems .................................................................................. 18
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC) ..................................................... 18
7.2. Building Plumbing and Domestic Hot Water ............................................................................. 19
7.3. Building Gas Distribution ........................................................................................................... 20
7.4. Building Electrical ...................................................................................................................... 20
7.5. Building Elevators and Conveying Systems .............................................................................. 21
7.6. Fire Protection and Security Systems ....................................................................................... 22
8. Interior Spaces .................................................................................................................................... 24
8.1. Interior Finishes ......................................................................................................................... 24
9. Other Structures ................................................................................................................................. 26
10. Certification ......................................................................................................................................... 27
11. Appendices ......................................................................................................................................... 28
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
1
www.EMGcorp.com p 800.733.0660
1. Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 800 Game Farm Road, Yorkville, IL 60560
Year Constructed/Renovated: Constructed 2000
Current Occupants: City of Yorkville
Percent Utilization: 100%
Management Point of Contact: Mr. Peter Ratos, Building Code Official, City of Yorkville
630.553.8574 phone
Property Type: Municipal
Site Area: 1 acre
Building Area: 18,988 SF
Number of Buildings: 1
Number of Stories: 2
Parking Type and Number of
Spaces: 66 spaces in open lots (12 for police vehicles)
Building Construction: Wood and concrete framed structure set on a concrete slab
Roof Construction: Pitched roof with asphalt shingles
Exterior Finishes: Brick veneer
Vinyl siding
Heating, Ventilation & Air
Conditioning:
Central system with furnaces and split-system condensing units
Supplemental components: electric wall heaters
Fire and Life/Safety:
Fire sprinklers, hydrants, smoke detectors, alarms, strobes,
extinguishers, pull stations, alarm panel, exit signs, and backup light
fixtures.
Dates of Visit: May 18, 2017
On-Site Point of Contact (POC): Peter Ratos
Assessment and Report
Prepared by: Kevin Koranda
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC Fair to Poor
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
2
www.EMGcorp.com p 800.733.0660
Systemic Condition Summary
Structure Fair Plumbing Fair
Roof Fair to Poor Electrical Fair
Vertical Envelope Fair Elevators Fair
Interiors Fair Fire Fair
The following bullet points highlight the most significant short term and modernization recommendations:
Roof replacement
HVAC upgrades and replacement of aged condensing units and furnaces
Asphalt parking area milling and overlaying
Site lighting replacements
Interior carpet replacements
Sprinkler system retrofit
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained in recent years and is in fair overall condition.
According to property management personnel, the property has not had a capital improvement expenditure program over the past three
years.
1.2. F acility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
3
www.EMGcorp.com p 800.733.0660
Fci Condition
Rating Definition Percentage
Value
Good In new or well-maintained condition, with no visual evidence
of wear, soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and
functioning condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its
useful or serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal
is now necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 7.7% Fair
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 24.7% Poor
Current Replacement Value (CRV) 18,988 SF * 183.24 / SF = $3,479,307
Year 0 (Current Year) - Immediate Repairs (IR) $271,023
Years 1-10 – Replacement Reserves (RR) $860,877
Total Capital Needs $1,131,900
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Roof replacement
HVAC upgrades and replacement of aged condensing units and furnaces
Asphalt parking area milling and overlaying
Site lighting replacements
Interior carpet replacements
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
1.3. Special Issues and Follow-Up Recommendations
As part of the FCA, a limited assessment of accessible areas of the building(s) was performed to determine the presence of fungal
growth, conditions conducive to fungal growth, and/or evidence of moisture. Property personnel were interviewed concerning any
known or suspected fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Sampling is not a part of this
assessment.
There are no visual indications of the presence of fungal growth, conditions conducive to fungal growth, or evidence of moisture in
representative readily accessible areas of the property.
1.4. Opinions of Probable Cost
Cost estimates are attached at the front of this report (following the cover page).
These estimates are based on Invoice or Bid Document/s provided either by the Owner/facility and construction costs developed by
construction resources such as R.S. Means and Marshall & Swift, EMG’s experience with past costs for similar properties, city cost
indexes, and assumptions regarding future economic conditions.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
4
www.EMGcorp.com p 800.733.0660
Opinions of probable costs should only be construed as preliminary, order of magnitude budgets. Actual costs most probably will vary
from the consultant’s opinions of probable costs depending on such matters as type and design of suggested remedy, quality of
materials and installation, manufacturer and type of equipment or system selected, field conditions, whether a physical deficiency is
repaired or replaced in whole, phasing of the work (if applicable), quality of contractor, quality of project management exercised, market
conditions, and whether competitive pricing is solicited, etc. ASTM E2018-08 recognizes that certain opinions of probable costs cannot
be developed within the scope of this guide without further study. Opinions of probable cost for further study should be included in the
FCA.
1.4.1. Methodology
Based upon site observations, research, and judgment, along with referencing Expected Useful Life (EUL) tables from various industry
sources, EMG opines as to when a system or component will most probably necessitate replacement. Accurate historical replacement
records, if provided, are typically the best source of information. Exposure to the elements, initial quality and installation, extent of use,
the quality and amount of preventive maintenance exercised, etc., are all factors that impact the effective age of a system or
component. As a result, a system or component may have an effective age that is greater or less than its actual chronological age.
The Remaining Useful Life (RUL) of a component or system equals the EUL less its effective age. Projections of Remaining Useful Life
(RUL) are based on continued use of the Property similar to the reported past use. Significant changes in occupants and/or usage may
affect the service life of some systems or components.
Where quantities could not be derived from an actual take-off, lump sum costs or allowances are used. Estimated costs are based on
professional judgment and the probable or actual extent of the observed defect, inclusive of the cost to design, procure, construct and
manage the corrections.
1.4.2. Immediate Repairs
Immediate repairs are opinions of probable costs that require immediate action as a result of: (1) material existing or potential unsafe
conditions, (2) material building or fire code violations, or (3) conditions that, if not addressed, have the potential to result in, or
contribute to, critical element or system failure within one year or will most probably result in a significant escalation of its remedial cost.
1.4.3. Replacement Reserves
Replacement Reserves are for recurring probable expenditures, which are not classified as operation or maintenance expenses. The
replacement reserves should be budgeted for in advance on an annual basis. Replacement Reserves are reasonably predictable both
in terms of frequency and cost. However, Replacement Reserves may also include components or systems that have an
indeterminable life but, nonetheless, have a potential for failure within an estimated time period.
Replacement Reserves exclude systems or components that are estimated to expire after the reserve term and are not considered
material to the structural and mechanical integrity of the subject property. Furthermore, systems and components that are not deemed
to have a material effect on the use of the Property are also excluded. Costs that are caused by acts of God, accidents, or other
occurrences that are typically covered by insurance, rather than reserved for, are also excluded.
Replacement costs are solicited from ownership/property management, EMG’s discussions with service companies, manufacturers'
representatives, and previous experience in preparing such schedules for other similar facilities. Costs for work performed by the
ownership’s or property management’s maintenance staff are also considered.
EMG’s reserve methodology involves identification and quantification of those systems or components requiring capital reserve funds
within the assessment period. The assessment period is defined as the effective age plus the reserve term. Additional information
concerning system’s or component’s respective replacement costs (in today's dollars), typical expected useful lives, and remaining
useful lives were estimated so that a funding schedule could be prepared. The Replacement Reserves Schedule presupposes that all
required remedial work has been performed or that monies for remediation have been budgeted for items defined in the Immediate
Repair Cost Estimate.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
5
www.EMGcorp.com p 800.733.0660
2. Purpose and Scope
2.1. Purpose
EMG was retained by the client to render an opinion as to the Property’s current general physical condition on the day of the site visit.
Based on the observations, interviews and document review outlined below, this report identifies significant deferred maintenance
issues, existing deficiencies, and material code violations of record at municipal offices, which affect the Property’s use. Opinions are
rendered as to its structural integrity, building system condition and the Property’s overall condition. The report also notes building
systems or components that have realized or exceeded their typical expected useful lives.
CONDITIONS:
The physical condition of building systems and related components are typically defined as being in one of five conditions: Excellent,
Good, Fair, Poor, Failed or a combination thereof. For the purposes of this report, the following definitions are used:
Excellent = New or very close to new; component or system typically has been installed within the past year, sound and
performing its function. Eventual repair or replacement will be required when the component or system either
reaches the end of its useful life or fails in service.
Good = Satisfactory as-is. Component or system is sound and performing its function, typically within the first third
of its lifecycle. However, it may show minor signs of normal wear and tear. Repair or replacement will be
required when the component or system either reaches the end of its useful life or fails in service.
Fair = Showing signs of wear and use but still satisfactory as-is, typically near the median of its estimated useful
life. Component or system is performing adequately at this time but may exhibit some signs of wear,
deferred maintenance, or evidence of previous repairs. Repair or replacement will be required due to the
component or system’s condition and/or its estimated remaining useful life.
Poor = Component or system is significantly aged, flawed, functioning intermittently or unreliably; displays obvious
signs of deferred maintenance; shows evidence of previous repair or workmanship not in compliance with
commonly accepted standards; has become obsolete; or exhibits an inherent deficiency. The present
condition could contribute to or cause the deterioration of contiguous elements or systems. Either full
component replacement is needed or repairs are required to restore to good condition, prevent premature
failure, and/or prolong useful life.
Failed
= Component or system has ceased functioning or performing as intended. Replacement, repair, or other
significant corrective action is recommended or required.
Not Applicable
= Assigning a condition does not apply or make logical sense, most commonly due to the item in question not
being present.
FORMAT OF THE BODY OF THE REPORT:
Throughout sections 5 through 9 of this report, each report section will typically contain three subsections organized in the following
sequence:
A descriptive table (and/or narrative), which identifies the components assessed, their condition, and other key data points.
A simple bulleted list of Anticipated Lifecycle Replacements, which lists components and assets typically in Excellent, Good, or Fair
condition at the time of the assessment but that will require replacement or some other attention once aged past their estimated
useful life. These listed components are typically included in the associated inventory database with costs identified and budgeted
beyond the first several years.
A bulleted cluster of Actions/Comments, which include more detailed narratives describing deficiencies, recommended repairs, and
short term replacements. The assets and components associated with these bullets are/were typically problematic and in Poor or
Failed condition at the time of the assessment, with corresponding costs included within the first few years.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
6
www.EMGcorp.com p 800.733.0660
PLAN TYPES:
Each line item in the cost database is assigned a Plan Type, which is the primary reason or rationale for the recommended
replacement, repair, or other corrective action. This is the “why” part of the equation. A cost or line item may commonly have more
than one applicable Plan Type; however, only one Plan Type will be assigned based on the “best” fit, typically the one with the greatest
significance. The following Plan Types are listed in general weighted order of importance:
Safety = An observed or reported unsafe condition that if left unaddressed could result in an injury; a system or
component that presents a potential liability risk.
Performance/Integrity = Component or system has failed, is almost failing, performs unreliably, does not perform as intended,
and/or poses a risk to overall system stability.
Accessibility = Does not meet ADA, UFAS, and/or other handicap accessibility requirements.
Environmental = Improvements to air or water quality, including removal of hazardous materials from the building or
site.
Modernization/Adaptation
= Conditions, systems, or spaces that need to be upgraded in appearance or function to meet current
standards, facility usage, or client/occupant needs.
Lifecycle/Renewal
= Any component or system in which future repair or replacement is anticipated beyond the next several
years and/or is of minimal substantial early-term consequence.
2.2. Scope
The standard scope of the Facility Condition Assessment includes the following:
Visit the Property to evaluate the general condition of the building and site improvements, review available construction documents in
order to familiarize ourselves with, and be able to comment on, the in-place construction systems, life safety, mechanical, electrical,
and plumbing systems, and the general built environment.
Identify those components that are exhibiting deferred maintenance issues and provide cost estimates for Immediate Costs and
Replacement Reserves based on observed conditions, maintenance history and industry standard useful life estimates. This will
include the review of documented capital improvements completed within the last five-year period and work currently contracted for, if
applicable.
Provide a full description of the Property with descriptions of in-place systems and commentary on observed conditions.
Provide a general statement of the subject Property’s compliance to Title III of the Americans with Disabilities Act. This will not
constitute a full ADA survey, but will help identify exposure to issues and the need for further review.
Perform a limited assessment of accessible areas of the building(s) for the presence of fungal growth, conditions conducive to fungal
growth, and/or evidence of moisture. EMG will also interview Project personnel regarding the presence of any known or suspected
fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Potentially affected areas will be photographed.
Sampling will not be considered in routine assessments.
List the current utility service providers.
Review maintenance records and procedures with the in-place maintenance personnel.
Observe a representative sample of the interior spaces/units, including vacant spaces/units, in order to gain a clear understanding of
the property’s overall condition. Other areas to be observed include the exterior of the property, the roofs, interior common areas,
and the significant mechanical, electrical and elevator equipment rooms.
Provide recommendations for additional studies, if required, with related budgetary information.
Provide an Executive Summary at the beginning of this report.
Prepare a mechanical equipment inventory list.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
7
www.EMGcorp.com p 800.733.0660
2.3. Personnel Interviewed
The management staff was interviewed for specific information relating to the physical property, available maintenance procedures,
historical performance of key building systems and components, available drawings and other documentation. The following personnel
from the facility and government agencies were interviewed in the process of conducting the FCA:
Name and Title Organization Phone Number
Peter Ratos
Building Code Official City of Yorkville 630.553.8574
The FCA was performed with the assistance of Peter Ratos, Building Code Official, City of Yorkville, the onsite Point of Contact (POC),
who was cooperative and provided information that appeared to be accurate based upon subsequent site observations. The onsite
contact is completely knowledgeable about the subject property and answered most questions posed during the interview process. The
POC’s involvement with the property has spanned the past 6 years.
2.4. Documentation Reviewed
Prior to the FCA, relevant documentation was requested that could aid in the knowledge of the subject property’s physical
improvements, extent and type of use, and/or assist in identifying material discrepancies between reported information and observed
conditions. The review of submitted documents does not include comment on the accuracy of such documents or their preparation,
methodology, or protocol. The Documentation Request Form is provided in Appendix E.
2.5. Pre-Survey Questionnaire
A Pre-Survey Questionnaire was sent to the POC prior to the site visit. The questionnaire is included in Appendix E. Information
obtained from the questionnaire has been used in preparation of this report.
2.6. Weather Conditions
5/18/17: Clear, with temperatures in the 70s (°F) and light winds.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
8
www.EMGcorp.com p 800.733.0660
3. Accessibility and Property Research
3.1. ADA Accessibility
Generally, Title III of the Americans with Disabilities Act (ADA) prohibits discrimination by entities to access and use of “areas of public
accommodations” and “commercial facilities” on the basis of disability. Regardless of its age, these areas and facilities must be
maintained and operated to comply with the Americans with Disabilities Act Accessibility Guidelines (ADAAG).
Buildings completed and occupied after January 26, 1992 are required to comply fully with the ADAAG. Existing facilities constructed
prior to this date are held to the lesser standard of compliance to the extent allowed by structural feasibility and the financial resources
available. As an alternative, a reasonable accommodation pertaining to the deficiency must be made.
During the FCA, a limited visual observation for ADA accessibility compliance was conducted. The scope of the visual observation was
limited to those areas set forth in EMG’s Abbreviated Accessibility Checklist provided in Appendix D of this report. It is understood by
the Client that the limited observations described herein does not comprise a full ADA Compliance Survey, and that such a survey is
beyond the scope of EMG’s undertaking. Only a representative sample of areas was observed and, other than as shown on the
Abbreviated Accessibility Checklist, actual measurements were not taken to verify compliance.
The facility does not appear to be accessible with Title III of the Americans with Disabilities Act. Elements as defined by the ADAAG
that are not accessible as stated within the priorities of Title III, are as follows:
Parking
Signage indicating accessible parking spaces for cars and vans are not provided.
Restrooms.
Wrap drain pipes below lavatory with insulation; protect against contact with hot, sharp, or abrasive surfaces.
A full ADA Compliance Survey may reveal additional aspects of the property that are not in compliance.
Corrections of these conditions should be addressed from a liability standpoint, but are not necessarily code violations. The Americans
with Disabilities Act Accessibility Guidelines concern civil rights issues as they pertain to the disabled and are not a construction code,
although many local jurisdictions have adopted the Guidelines as such. The cost to address the achievable items noted above is
included in the cost tables.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
9
www.EMGcorp.com p 800.733.0660
4. Existing Building Assessment
4.1. Unit or Space Types
All 18,988 square feet of the building are currently occupied by the City of Yorkville and is used as the city hall and police department.
The spaces are mostly office areas. Other significant spaces include: the city council chambers and meeting rooms, and a police
vehicle service bay. Other spaces include a combination of restrooms, mechanical spaces, storage areas, and other utility spaces.
4.2. Inaccessible Areas or Key Spaces Not Observed
All of the interior spaces were observed in order to gain a clear understanding of the property’s overall condition. Other areas accessed
included the site within the property boundaries, exterior of the property and the roof. All areas of the property were available for
observation during the site visit.
A “down unit” or area is a term used to describe a unit or space that cannot be occupied due to poor conditions such as fire damage,
water damage, missing equipment, damaged floor, wall or ceiling surfaces, or other significant deficiencies. There are no down units or
areas.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
10
www.EMGcorp.com p 800.733.0660
5. Site Improvements
5.1. Utilities
The following table identifies the utility suppliers and the condition and adequacy of the services.
Site Utilities
Utility Supplier Condition and Adequacy
Sanitary sewer City of Yorkville Good and Adequate
Storm sewer City of Yorkville Good and Adequate
Domestic water City of Yorkville Good and Adequate
Electric service Commonwealth Edison Good and Adequate
Natural gas service Nicor Gas Good and Adequate
Actions/Comments:
According to the POC, the utilities provided are adequate for the property. There are no unique, onsite utility systems such as septic
systems, water or waste water treatment plants, or propane gas tanks. An emergency electrical generator is located on the site.
5.2. Parking, Paving, and Sidewalks
Item Description
Main Ingress and Egress Game Farm Road
Access from West
Additional Entrances Adjacent parking areas/drive aisles
Additional Access from North and South
Paving and Flatwork
Item Material Last Work Done Condition
Entrance Driveway Apron Asphalt 2000 Fair
Parking Lot Asphalt 2000 Fair to Poor
Drive Aisles Asphalt 2000 Fair to Poor
Service Aisles None -- --
Sidewalks Concrete 2000 Fair
Curbs Concrete 2000 Fair
Site Stairs Concrete 2000 Fair to Poor
Pedestrian Ramps Concrete 2000 Fair
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
11
www.EMGcorp.com p 800.733.0660
Parking Count
Open Lot Carport Private Garage Subterranean
Garage
Freestanding Parking
Structure
54 spaces
12 spaces for
police vehicles
- - - -
Total Number of ADA Compliant Spaces 2
Number of ADA Compliant Spaces for Vans 0
Total Parking Spaces 66
Parking Ratio (Spaces/Apartments) NA
Method of Obtaining Parking Count Physical count
Exterior Stairs
Location Material Handrails Condition
None -- -- --
Anticipated Lifecycle Replacements:
Asphalt seal coating
Asphalt milling and overlaying
Sidewalks
Actions/Comments:
The asphalt pavement exhibits significant areas of deterioration in the form of alligator cracking, raveling, and medium-sized
depressions. The deterioration primarily affects the west lot and northeast lot. All of the paving must be overlaid with new asphalt
paving in order to maintain the integrity of the overall pavement system.
5.3. Drainage Systems and Erosion Control
Drainage System and Erosion Control
System Exists At Site Condition
Surface Flow ☐ --
Inlets ☒ Fair
Swales ☒ Fair
Detention pond ☐ --
Lagoons ☐ --
Ponds ☐ --
Underground Piping ☒ Fair
Pits ☐ --
Municipal System ☒ Fair
Dry Well ☐ --
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
12
www.EMGcorp.com p 800.733.0660
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
There is no evidence of storm water runoff from adjacent properties. The storm water system appears to provide adequate runoff
capacity. There is no evidence of major ponding or erosion.
5.4. Topography and Landscaping
Item Description
Site Topography Relatively flat
Landscaping
Trees Grass Flower
Beds Planters
Drought
Tolerant
Plants
Decorative
Stone None
☒ ☒ ☒ ☐ ☐ ☐ ☐
Landscaping
Condition Fair
Irrigation
Automatic
Underground Drip Hand Watering None
☐ ☐ ☐ ☒
Irrigation Condition --
Retaining Walls
Type Location Condition
Concrete Stairwells Fair
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The topography and adjacent uses do not appear to present conditions detrimental to the property. There are no significant areas of
erosion.
5.5. General Site Improvements
Property Signage
Property Signage Post mounted wood
Street Address Displayed? Yes
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
13
www.EMGcorp.com p 800.733.0660
Site and Building Lighting
Site Lighting
None Pole Mounted Bollard Lights Ground
Mounted
Parking Lot
Pole Type
☐ ☒ ☐ ☐ ☐
Fair
Building Lighting
None Wall Mounted Recessed Soffit
☐ ☒ ☒
Fair
REFUSE DISPOSAL
Refuse Disposal Common area dumpsters
Dumpster Locations Mounting Enclosure Contracted? Condition
Northeast parking area Concrete
pad Chain link fence Yes Fair
Other Site Amenities
Description Location Condition
Playground Equipment None -- --
Tennis Courts None -- --
Basketball Court None -- --
Swimming Pool None -- --
Anticipated Lifecycle Replacements:
Exterior lighting
Site lighting
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
14
www.EMGcorp.com p 800.733.0660
6. Building Architectural and Structural Systems
6.1. Foundations
Building Foundation
Item Description Condition
Foundation Concrete foundation walls Good
Basement and Crawl Space Concrete slab and concrete walls Good
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
Isolated areas of the foundation systems are exposed, which allows for limited observation. The foundation systems are concealed.
There are no significant signs of settlement, deflection, or movement. The basement walls appear intact and structurally sound.
There is no evidence of movement or water infiltration.
6.2. Superstructure
Building Superstructure
Item Description Condition
Framing / Load-Bearing Walls Conventional wood/metal studs Good
Ground Floor Concrete slab Good
Upper Floor Framing Concrete beams Good
Upper Floor Decking Metal decking Good
Roof Framing Wood trusses Good
Roof Decking Plywood or OSB Good
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The superstructure is exposed in some locations, which allows for limited observation. Walls and floors appear to be plumb, level,
and stable. There are no significant signs of deflection or movement.
6.3. Roofing
Primary Roof
Type / Geometry Hip Roof Finish Asphalt shingles
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
15
www.EMGcorp.com p 800.733.0660
Primary Roof
Maintenance In-house Staff Roof Age 18 Yrs
Flashing Sheet metal Warranties Unknown
Parapet Copings None Roof Drains Gutters and downspouts
Fascia Metal Panel Insulation Fiberglass batts
Soffits Exposed Soffits Skylights No
Attics Yes Ponding No
Ventilation Source-1 Power Vents Leaks Observed No
Ventilation Source-2 None Roof Condition Fair
The primary roof is located over the majority of the building at the newer sections of the facility.
Anticipated Lifecycle Replacements:
Asphalt shingles
Actions/Comments:
The roof finishes are original. Information regarding roof warranties or bonds was not available.
According to the POC, there are no active roof leaks. There is no evidence of active roof leaks.
There is no evidence of roof deck or insulation deterioration. The roof substrate and insulation should be inspected during any future
roof repair or replacement work.
Roof drainage appears to be adequate. Clearing and minor repair of drain system components should be performed regularly as part
of the property management’s routine maintenance and operations program.
The attics are not accessible and it could not be determined if there is moisture, water intrusion, or excessive daylight in the attics.
The field of the roofs have curling and deteriorated shingles, primarily at the south side of the facility. Replacement of the entire roof
is recommended.
6.4. Exterior Walls
Building Exterior Walls
Type Location Condition
Primary Finish Vinyl siding Fair
Secondary Finish Brick veneer Good
Accented with None --
Soffits Exposed Fair
Building sealants (caulking) are located between dissimilar materials, at joints, and around window and door openings.
Anticipated Lifecycle Replacements:
Vinyl siding
Caulking
Masonry re-pointing
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
16
www.EMGcorp.com p 800.733.0660
Actions/Comments:
The vinyl siding has isolated areas of cracking and damage on the south side of the building near the condensing unit. The damaged
finishes must be replaced. The cost for this work is relatively insignificant and can be accomplished through the City’s routine
maintenance program.
6.5. Exterior and Interior Stairs
Building Exterior and Interior Stairs
Type Description Riser Handrail Balusters Condition
Building Exterior Stairs Concrete stairs Closed Metal Metal Good
Building Interior Stairs Steel-framed with pre-cast
treads Closed Metal Metal Good
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended.
6.6. Exterior Windows and Doors
Building Windows
Window Framing Glazing Location Window
Screen Condition
Aluminum framed storefront Double glaze Building exterior ☐ Fair
Vinyl framed Double glaze Building exterior ☒ Fair
Building Doors
Main Entrance Doors Door Type Condition
Fully glazed, metal framed Fair
Secondary Entrance Doors Partially glazed, metal framed Fair
Service Doors Metal, insulated Fair
Overhead Doors Vinyl, sectional Fair
Anticipated Lifecycle Replacements:
Storefront glazing
Exterior storefront doors
Overhead doors
Actions/Comments:
There are a significant number of delaminated doors. The damaged doors must be refinished.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
17
www.EMGcorp.com p 800.733.0660
6.7. Patio, Terrace, and Balcony
Building Patio, Terrace and Balcony
Type Description Location Condition
Ground Floor Patio Pavers East elevation Fair
Upper Balcony Structure None -- --
Balcony Decks None -- --
Balcony Deck Toppings None -- --
Balcony Guardrails None -- --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
18
www.EMGcorp.com p 800.733.0660
7. Building Mechanical and Plumbing Systems
See the Mechanical Equipment List in the Appendices for the quantity, manufacturer’s name, model number, capacity and year of
manufacturer of the major mechanical equipment, if available.
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC)
Individual Units
Primary Components Split system furnaces and condensing units
Cooling (if separate from above) performed via components above
Quantity and Capacity Ranges 8 furnaces ranging from 120 MBH to 135 MBH
9 condensing units ranging from 1 ton to 5 tons
Total Heating or Cooling Capacity 1032 MBH
31 tons
Heating Fuel
Refrigerant
Natural gas
R-22 and R-134A
Location of Equipment Furnaces in mechanical rooms
Condensing units located adjacent to east wall
Space Served by System Entire building
Age Ranges Majority dated 2000
Primary Component Condition Fair to Poor
Supplemental Components
Supplemental Component #1 Split system condensing unit
Location / Space Served Adjacent east wall/IT Room
Condition Fair
Supplemental Component #2 Electric wall heater
Location / Space Served Entry vestibule
Condition Fair
Controls and Ventilation
HVAC Control System Individual programmable thermostats/controls
HVAC Control System Condition Fair
Building Ventilation Roof top exhaust fans
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
19
www.EMGcorp.com p 800.733.0660
Controls and Ventilation
Ventilation System Condition Fair
Anticipated Lifecycle Replacements:
Furnaces
Condensing units
Gas-fried unit heaters
Exhaust fans
Electric wall heaters
Actions/Comments:
The HVAC systems are maintained by an outside contractor. It is unknown whether records of the installation, maintenance,
upgrades, and replacement of the HVAC equipment at the property have been maintained.
Approximately 90 percent of the HVAC equipment is original. The HVAC equipment varies in age. HVAC equipment is replaced on
an "as needed" basis.
The HVAC equipment appears to be not functioning adequately. The property management staff was interviewed about the historical
and recent performance of the equipment and systems. The staff member reported that the system is zoned poorly and does not
keep up with cooling loads. A budgetary cost for the upgrade or addition of supplementary components has been included in the
report.
The existing component are generally in fair condition, however, due to the inevitable failure of parts and components over time,
some of the equipment will require replacement.
7.2. Building Plumbing and Domestic Hot Water
Building Plumbing System
Type Description Condition
Water Supply Piping Copper Fair
Waste/Sewer Piping PVC Fair
Vent Piping PVC Fair
Water Meter Location Basement mechanical room
Domestic Water Heaters or Boilers
Components Water Heater
Fuel Natural gas
Quantity and Input Capacity 1 unit at 75,100 BTU/h
Storage Capacity 70 gallons
Boiler or Water Heater Condition Good
Supplementary Storage Tanks? No
Storage Tank Quantity & Volume None
Quantity of Storage Tanks 0
Storage Tank Condition --
Domestic Hot Water Circulation Pumps (3 HP and over) No
Adequacy of Hot Water Adequate
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
20
www.EMGcorp.com p 800.733.0660
Domestic Water Heaters or Boilers
Adequacy of Water Pressure Adequate
Plumbing Fixtures
Water Closets Commercial
Toilet (Water Closet) Flush Rating 1.6 GPF
Common Area Faucet Nominal Flow Rate 2.0 GPM
Condition Fair
Anticipated Lifecycle Replacements:
Water heaters
Toilets
Urinals
Sinks
Ejector pumps
Eyewash station
Toilet stalls
Drinking fountains
Actions/Comments:
The plumbing systems appear to be well maintained and functioning adequately. The water pressure appears to be sufficient. No
significant repair actions or short term replacement costs are required. Routine and periodic maintenance is recommended. Future
lifecycle replacements of the components or systems listed above will be required.
7.3. Building Gas Distribution
Gas service is supplied from the gas main on the adjacent public street. The gas meter and regulator is located along the exterior wall
of the building. The gas distribution piping within the building is malleable steel (black iron).
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The pressure and quantity of gas appear to be adequate.
The gas meter and regulator appear to be functioning adequately and will require routine maintenance.
Only limited observation of the gas distribution piping can be made due to hidden conditions.
7.4. Building Electrical
Building Electrical Systems
Electrical Lines Underground Transformer Pad-mounted
Main Service Size 800 Amps Volts 120/208 Volt, three-phase
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
21
www.EMGcorp.com p 800.733.0660
Building Electrical Systems
Meter & Panel Location
Basement mechanical
room Branch Wiring Copper
Conduit Metallic Step-Down
Transformers? No
Security / Surveillance
System? No Building Intercom
System? No
Lighting Fixtures T-8
Main Distribution Condition Good
Secondary Panel and
Transformer Condition Good
Lighting Condition Fair
Building Emergency System
Size 125 kW Fuel Diesel
Generator / UPS Serves
Emergency lights,
elevator Tank Location Integral
Testing Frequency Bi-Weekly Tank Type Integral ("belly") tank
Generator / UPS Condition Fair
Anticipated Lifecycle Replacements:
Circuit breaker panels
Main switchgear
Interior light fixtures
Emergency generator
Ceiling fans
Actions/Comments:
The onsite electrical systems up to the meters are owned and maintained by the respective utility company.
The electrical service and capacity appear to be adequate for the property’s demands.
The switchgear and some panels are original 2000 components. The electrical service is reportedly adequate for the facility’s needs.
However, due to the age of the panels and switchgear and increasing difficulty of obtaining replacement parts over time, lifecycle
replacements are recommended per above.
7.5. Building Elevators and Conveying Systems
Building Elevators
Manufacturer Dover Machinery Location Ground floor or basement
adjacent to shaft
Safety Stops Electronic Emergency Equipment Yes
Cab Floor Finish Vinyl-tiled Cab Wall Finish Plastic-laminated wood
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
22
www.EMGcorp.com p 800.733.0660
Building Elevators
Hydraulic Elevators 1 car at 2500 lbs
Overhead Traction Elevators None
Freight Elevators None
Machinery Condition Fair
Controls Condition Fair
Cab Finish Condition Fair
Other Conveyances None
Other Conveyance Condition NA
Anticipated Lifecycle Replacements:
Elevator controls
Hydraulic machinery
Actions/Comments:
The elevators are serviced by Schindler Elevator Corp on a routine basis. The elevator machinery and controls are the originally
installed system. The elevators will require continued periodic maintenance.
The elevators are inspected on an annual basis by the municipality, and a certificate of inspection is displayed in each elevator cab.
The emergency communication equipment in the elevator cabs appears to be functional. Equipment testing is not within the scope of
the work.
The finishes in the elevator cabs will require replacement. The cost to replace the finishes is relatively insignificant and the work can
be performed as part of the property management’s operations program.
7.6. Fire Protection and Security Systems
Item Description
Type Wet pipe
Fire Alarm System
Central Alarm Panel ☒ Battery-Operated Smoke
Detectors ☐ Alarm Horns ☒
Annunciator Panels ☒ Hard-Wired Smoke
Detectors ☒ Strobe Light Alarms ☒
Pull Stations ☒ Emergency Battery-Pack
Lighting ☒ Illuminated EXIT Signs ☒
Alarm System
Condition Fair
Sprinkler System
None ☐ Standpipes ☐ Backflow Preventer ☒
Hose Cabinets ☐ Fire Pumps ☐ Siamese Connections ☐
Suppression
Condition Fair
Central Alarm Panel
System
Location of Alarm Panel Installation Date of Alarm Panel
Basement mechanical room 2000
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
23
www.EMGcorp.com p 800.733.0660
Item Description
Type Wet pipe
Fire Extinguishers
Last Service Date Servicing Current?
March, 2017 Yes
Hydrant Location Adjacent to building
Siamese Location None
Special Systems Kitchen Suppression System ☐ Computer Room Suppression System ☐
Anticipated Lifecycle Replacements:
Central alarm panel
Exit signs
Backup light fixtures
Extinguishers
Automated external defibrillator
Actions/Comments:
The majority of the building is not protected by fire suppression; sprinkler heads are currently limited to the files storage room in the
basement near the mechanical room. Due to its construction date, the facility is most likely “grandfathered” by code and the
installation of fire sprinklers not required until major renovations are performed. Regardless of when or if installation of facility-wide
fire suppression is required by the governing municipality, EMG recommends a retrofit be performed.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
24
www.EMGcorp.com p 800.733.0660
8. I nterior Spaces
8.1. I nterior Finishes
All 18,988 square feet of the building are currently occupied by the City of Yorkville and is used as the city hall and police department.
The spaces are mostly office areas. Other significant spaces include: the city council chambers and meeting rooms, and a police
vehicle service bay. Other spaces include a combination of restrooms, mechanical spaces, storage areas, and other utility spaces.
The following table generally describes the locations and typical conditions of the interior finishes within the facility:
Typical Floor Finishes
Floor Finish Locations General Condition
Carpet Throughout building Fair
Vinyl tile Throughout building, stairwells, miscellaneous
spaces Fair
Ceramic tile Restrooms Fair
Quarry tile Entry vestibule Fair
Concrete Sally port, storage areas Fair
Typical Wall Finishes
Wall Finish Locations General Condition
Painted drywall Throughout building Fair
Exposed CMU/masonry Basement mechanical room Fair
Typical Ceiling Finishes
Ceiling Finish Locations General Condition
Suspended T-bar (Acoustic) Office spaces, basement areas Fair
Painted drywall Council chambers, entry vestibule, sally port Fair
Exposed structure Basement mechanical room Fair
Interior Doors
Item Type Condition
Interior Doors Hollow core
Solid core Fair
Door Framing Wood
Metal Fair
Fire Doors Yes Fair
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
25
www.EMGcorp.com p 800.733.0660
Anticipated Lifecycle Replacements:
Carpet
Vinyl tile
Interior paint
Suspended acoustic ceiling tile
Interior doors
Kitchenette cabinetry
Residential grade appliances
Actions/Comments:
The interior areas were last renovated in 2015. The renovations consisted primarily of repainting.
The carpeting in the city hall area is rippling and in poor condition. Replacement of the carpeting in this area is recommended.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
26
www.EMGcorp.com p 800.733.0660
9. Other Structures
Not applicable. There are no major accessory structures.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
27
www.EMGcorp.com p 800.733.0660
10. Certification
The City of Yorkville retained EMG to perform this Facility Condition Assessment in connection with its continued operation of City
Hall/Police Department, Yorkville, IL, the “Property”. It is our understanding that the primary interest of the City of Yorkville is to locate
and evaluate materials and building system defects that might significantly affect the value of the property and to determine if the
present Property has conditions that will have a significant impact on its continued operations.
The conclusions and recommendations presented in this report are based on the brief review of the plans and records made available
to our Project Manager during the site visit, interviews of available property management personnel and maintenance contractors
familiar with the Property, appropriate inquiry of municipal authorities, our Project Manager’s walk-through observations during the site
visit, and our experience with similar properties.
No testing, exploratory probing, dismantling or operating of equipment or in depth studies were performed unless specifically required
under Section 2 of this report. This assessment did not include engineering calculations to determine the adequacy of the Property’s
original design or existing systems. Although walk-through observations were performed, not all areas were observed (See Section 4.2
for areas observed). There may be defects in the Property, which were in areas not observed or readily accessible, may not have been
visible, or were not disclosed by management personnel when questioned. The report describes property conditions at the time that
the observations and research were conducted.
This report has been prepared on behalf of and exclusively for the use of the City of Yorkville for the purpose stated within Section 2 of
this report. The report, or any excerpt thereof, shall not be used by any party other than the City of Yorkville or for any other purpose
than that specifically stated in our agreement or within Section 2 of this report without the express written consent of EMG.
Any reuse or distribution of this report without such consent shall be at the City of Yorkville and the recipient’s sole risk, without liability
to EMG.
Prepared by: Kevin Koranda,
Project Manager
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
28
www.EMGcorp.com p 800.733.0660
11. Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: EMG Accessibility Checklist
Appendix D: Pre-Survey Questionnaire
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
CITY HALL/POLICE DEPARTMENT
800 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
PHOTO
#1:
COVER PHOTO PHOTO
#2:
FRONT ELEVATION
PHOTO
#3:
NORTH ELEVATION PHOTO
#4:
NORTH ELEVATION
PHOTO
#5:
EAST ELEVATION PHOTO
#6:
SOUTH ELEVATION
CITY HALL/POLICE DEPARTMENT
800 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
PHOTO
#7:
SITE IDENTIFICATION SIGNAGE PHOTO
#8:
SIDEWALK
PHOTO
#9:
CURB, DAMAGED PHOTO
#10:
SITE LIGHTING
PHOTO
#11:
MAIN ENTRANCE RAMP PHOTO
#12:
RAMP WALL
CITY HALL/POLICE DEPARTMENT
800 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
PHOTO
#13:
STAIR WALL, SPALLING PHOTO
#14:
FRONT LOT, CRACKING AND
DETERIORATED
PHOTO
#15:
NORTHEAST LOT, CRACKING PHOTO
#16:
DUMPSTER AREA
PHOTO
#17:
BUILDING LIGHTING PHOTO
#18:
BUILDING LIGHTING
CITY HALL/POLICE DEPARTMENT
800 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
PHOTO
#19:
EXTERIOR DOOR PHOTO
#20:
EXTERIOR DOOR
PHOTO
#21:
MAIN ENTRANCE, DOOR OPENER PHOTO
#22:
SMALL BASEMENT WINDOW
PHOTO
#23:
LARGE WINDOW PHOTO
#24:
PATIO AREA
CITY HALL/POLICE DEPARTMENT
800 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
PHOTO
#25:
ROOF PHOTO
#26:
ROOF, CURLING
PHOTO
#27:
ROOF PHOTO
#28:
VINYL SIDING
PHOTO
#29:
STAIRWELL PHOTO
#30:
STAIRWELL
CITY HALL/POLICE DEPARTMENT
800 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
PHOTO
#31:
GENERATOR PHOTO
#32:
CONDENSING UNITS
PHOTO
#33:
DISTRIBUTION PANEL PHOTO
#34:
CIRCUIT BREAKERS
PHOTO
#35:
MAIN MECHANICAL ROOM PHOTO
#36:
FURNACES
CITY HALL/POLICE DEPARTMENT
800 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
PHOTO
#37:
UNIT HEATER, SALLY PORT PHOTO
#38:
THERMOSTAT
PHOTO
#39:
WALL MOUNTED ELECTRIC HEATER PHOTO
#40:
BACKUP LIGHT FIXTURE AND
STROBE ALARM
PHOTO
#41:
SMOKE DETECTOR PHOTO
#42:
EXIT SIGN
CITY HALL/POLICE DEPARTMENT
800 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
PHOTO
#43:
EXTINGUISHER PHOTO
#44:
RESTROOM
PHOTO
#45:
URINAL PHOTO
#46:
TOILET
PHOTO
#47:
LAVATORY SINKS PHOTO
#48:
BUILDING DEPARTMENT OFFICE
AREA
CITY HALL/POLICE DEPARTMENT
800 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
PHOTO
#49:
STAIRS PHOTO
#50:
FIRE DOOR
PHOTO
#51:
ENTRY VESTIBULE PHOTO
#52:
HALLWAY
PHOTO
#53:
DRINKING FOUNTAINS PHOTO
#54:
COUNCIL CHAMBERS
CITY HALL/POLICE DEPARTMENT
800 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
PHOTO
#55:
LIGHTING FIXTURES PHOTO
#56:
ACOUSTICAL TILE CEILING
PHOTO
#57:
CARPET, RIPPLING PHOTO
#58:
KITCHENETTE
PHOTO
#59:
SOLID CORE DOOR PHOTO
#60:
SALLY PORT
CITY HALL/POLICE DEPARTMENT
800 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
PHOTO
#61:
BATHROOM, POLICE AREA PHOTO
#62:
EYEWASH
PHOTO
#63:
OFFICE, POLICE AREA PHOTO
#64:
OFFICE, POLICE AREA
PHOTO
#65:
KITCHENETTE PHOTO
#66:
POLICE SERVICE DESK AND
WAITING ROOM
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
City Hall/Police Station
Project Number:
122700.17R000-004.322
Source:
Google Earth Pro
On-Site Date:
5/18/2017
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
Appendix C:
EMG Accessibility Checklist
Page 1 of 4
Date Completed: 5/19/17
Property Name: City Hall/Police Station
EMG Project Number: 122700.17R000-004.322
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? ✔
2
Have any ADA improvements been made
to the property? ✔
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? ✔
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
✔
5
Is any litigation pending related to ADA
issues? ✔
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
✔
2
Are there sufficient van-accessible parking
spaces available? ✔
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
✔
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
✔
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
✔
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
✔
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) ✔
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? ✔
Page 2 of 4
Ramps Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? ✔
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
✔
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? ✔
2
If the main entrance is inaccessible, are
there alternate accessible entrances? ✔
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
✔
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? ✔
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? ✔
3
Is there a path of travel that does not
require the use of stairs? ✔
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? ✔
2
Are there visual and audible signals inside
cars indicating floor change? ✔
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? ✔
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? ✔
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? ✔
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? ✔
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? ✔
2
Are pull handles push/pull or lever type?
✔
3
Are there audible and visual fire alarm
devices in the toilet rooms? ✔
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? ✔
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? ✔
6
In unisex toilet rooms, are there safety
alarms with pull cords? ✔
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? ✔
8
Are grab bars provided in toilet stalls?
✔
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? ✔
10
Are sink handles operable with one hand
without grasping, pinching or twisting? ✔
11
Are exposed pipes under sink sufficiently
insulated against contact? ✔
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
✔
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
✔
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
✔
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. ✔
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
✔
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
✔
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
✔
*Based on visual observation only. The slope was not confirmed through measurements.
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
Appendix D:
Pre-Survey Questionnaire
CITY HALL/POLICE DEPARTMENT EMG PROJECT NO.: 122700.17R000-004.322
www.EMGcorp.com p 800.733.0660
On the day of the site visit, provide EMG's Field Observer access to all of the available documents listed below.
Provide copies if possible.
INFORMATION REQUIRED
1. All available construction documents (blueprints) for
the original construction of the building or for any tenant
improvement work or other recent construction work.
2. A site plan, preferably 8 1/2" X 11", which depicts the
arrangement of buildings, roads, parking stalls, and other
site features.
3. For commercial properties, provide a tenant list which
identifies the names of each tenant, vacant tenant units,
the floor area of each tenant space, and the gross and
net leasable area of the building(s).
4. For apartment properties, provide a summary of the
apartment unit types and apartment unit type quantities,
including the floor area of each apartment unit as
measured in square feet.
5. For hotel or nursing home properties, provide a
summary of the room types and room type quantities.
6. Copies of Certificates of Occupancy, building permits,
fire or health department inspection reports, elevator
inspection certificates, roof or HVAC warranties, or any
other similar, relevant documents.
7. The names of the local utility companies which serve
the property, including the water, sewer, electric, gas,
and phone companies.
8. The company name, phone number, and contact
person of all outside vendors who serve the property,
such as mechanical contractors, roof contractors, fire
sprinkler or fire extinguisher testing contractors, and
elevator contractors.
9. A summary of recent (over the last 5 years) capital
improvement work which describes the scope of the
work and the estimated cost of the improvements.
Executed contracts or proposals for improvements.
Historical costs for repairs, improvements, and
replacements.
10. Records of system & material ages (roof, MEP,
paving, finishes, furnishings).
11. Any brochures or marketing information.
12. Appraisal, either current or previously prepared.
13. Current occupancy percentage and typical turnover
rate records (for commercial and apartment properties).
14. Previous reports pertaining to the physical condition
of property.
15. ADA survey and status of improvements
implemented.
16. Current / pending litigation related to property
condition.
Your timely compliance with this request is greatly appreciated.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Beecher Community Center
908 Game Farm Road
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-005.322 September 13, 2017 May 23, 2017
FACILITY CONDITION ASSESSMENT
Immediate Repairs Report
Beecher Community Center
9/13/2017
Location Name EMG Renamed Item NumberID Cost Description QuantityUnit Unit Cost Subtotal Deficiency Repair Estimate *
Beecher Community Center 5.4 612426 Retaining Wall, Brick/Stone (per SF Face), Repair 50 SF $11.39 $569 $569
Beecher Community Center 7.2 612452 Backflow Preventer, 2", Replace 1 EA $2,603.17 $2,603 $2,603
Beecher Community Center 7.2 612469 ADA, Restroom, Lavatory Pipe Wraps, Install 6 EA $75.90 $455 $455
Beecher Community Center 7.6 612440 Fire Alarm System, Office Building, Upgrade 9423 SF $2.36 $22,234 $22,234
Beecher Community Center 7.6 612434 Fire Alarm Control Panel, Addressable, Replace 1 EA $20,297.59 $20,298 $20,298
Immediate Repairs Total $46,159
* Location Factor included in totals.
Replacement Reserves Report
Beecher Community Center
9/13/2017
Location Name
EMG
Renamed
Item
Number
ID Cost Description Lifespan
(EUL)EAge RUL QuantityUnit Unit Cost Subtotal 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036
Deficiency
Repair
Estimate
Beecher Community Center 5.2 612307 Parking Lots, Asphalt Pavement, Mill & Overlay 25 23 2 43802 SF $3.28 $143,688 $143,688 $143,688
Beecher Community Center 5.2 612308 Parking Lots, Asphalt Pavement, Seal & Stripe 5 0 5 11308 SF $0.38 $4,291 $4,291 $4,291 $4,291 $12,874
Beecher Community Center 5.2 612309 Pedestrian Pavement, Sidewalk, Concrete, Replace 30 29 1 6052 SF $19.82 $119,962 $119,962 $119,962
Beecher Community Center 5.4 612426 Retaining Wall, Brick/Stone (per SF Face), Repair 0 0 0 50 SF $11.39 $569 $569 $569
Beecher Community Center 5.5 612412 High Pressure Sodium Lighting Fixture, 400 W, Replace 20 10 10 1 EA $1,033.67 $1,034 $1,034 $1,034
Beecher Community Center 5.5 612305 Signage, Property, Monument/Pylon, Replace 20 10 10 1 EA $8,602.00 $8,602 $8,602 $8,602
Beecher Community Center 5.5 612411 Flagpole, Metal, Replace 20 5 15 1 EA $2,530.00 $2,530 $2,530 $2,530
Beecher Community Center 5.5 612410 Pole Light, Exterior, 135 to 1000 W HID (Fixture Only), Replace 20 10 10 4 EA $4,630.42 $18,522 $18,522 $18,522
Beecher Community Center 6.3 612306 Roof, Asphalt Shingle, Replace 20 15 5 11308 SF $3.42 $38,679 $38,679 $38,679
Beecher Community Center 6.4 612310 Exterior Wall, Aluminum Siding, Replace 40 34 6 6000 SF $8.67 $52,049 $52,049 $52,049
Beecher Community Center 6.6 612419 Window, Aluminum, Replace 30 28 2 2 EA $584.21 $1,168 $1,168 $1,168
Beecher Community Center 6.6 612418 Window, Aluminum Double-Glazed Large, Replace 30 15 15 6 EA $870.45 $5,223 $5,223 $5,223
Beecher Community Center 6.6 612420 Window, Aluminum Double-Glazed Small, Replace 30 15 15 29 EA $584.21 $16,942 $16,942 $16,942
Beecher Community Center 6.6 612414 Exterior Door, Fully-Glazed Aluminum-Framed Swinging Motor-Operated, Replace 30 20 10 2 EA $10,194.36 $20,389 $20,389 $20,389
Beecher Community Center 6.6 612413 Exterior Door, Fully-Glazed Aluminum-Framed Swinging, Replace 30 20 10 5 EA $2,106.57 $10,533 $10,533 $10,533
Beecher Community Center 6.7 612425 Pedestrian Pavement, Sidewalk, Clay Brick/Masonry Pavers, Replace 30 20 10 75 SF $34.11 $2,558 $2,558 $2,558
Beecher Community Center 7.1 612487 Air Handler, Exterior, 10,001 to 16,000 CFM, Replace 15 12 3 1 EA $70,713.29 $70,713 $70,713 $70,713 $141,427
Beecher Community Center 7.1 612483 Air Handler, Exterior, 4,001 to 6,000 CFM, Replace 15 12 3 1 EA $27,804.57 $27,805 $27,805 $27,805 $55,609
Beecher Community Center 7.1 612482 Air Handler, Exterior, 8,001 to 10,000 CFM, Replace 15 12 3 1 EA $45,895.13 $45,895 $45,895 $45,895 $91,790
Beecher Community Center 7.1 612490 Exhaust Fan, Centrifugal, 1,500 CFM, Replace 15 12 3 1 EA $2,664.18 $2,664 $2,664 $2,664 $5,328
Beecher Community Center 7.1 612488 Exhaust Fan, Centrifugal, 2,500 CFM, Replace 15 12 3 1 EA $3,072.78 $3,073 $3,073 $3,073 $6,146
Beecher Community Center 7.1 612489 Exhaust Fan, Centrifugal, 2,000 CFM, Replace 15 12 3 1 EA $2,664.18 $2,664 $2,664 $2,664 $5,328
Beecher Community Center 7.2 612475 Toilet, Tankless (Water Closet), Replace 20 10 10 5 EA $842.97 $4,215 $4,215 $4,215
Beecher Community Center 7.2 612476 Urinal, Vitreous China, Replace 20 10 10 2 EA $1,193.44 $2,387 $2,387 $2,387
Beecher Community Center 7.2 612468 Lavatory, Vitreous China, Replace 20 10 10 6 EA $572.66 $3,436 $3,436 $3,436
Beecher Community Center 7.2 612478 Service Sink, Porcelain Enamel, Cast Iron, Replace 20 10 10 1 EA $1,360.33 $1,360 $1,360 $1,360
Beecher Community Center 7.2 612462 Sink, Stainless Steel, Replace 20 10 10 2 EA $1,054.05 $2,108 $2,108 $2,108
Beecher Community Center 7.2 612481 Drinking Fountain, Refrigerated, Replace 10 5 5 1 EA $1,257.51 $1,258 $1,258 $1,258 $2,515
Beecher Community Center 7.2 612452 Backflow Preventer, 2", Replace 15 15 0 1 EA $2,603.17 $2,603 $2,603 $2,603 $5,206
Beecher Community Center 7.2 612477 Water Heater, Gas, Residential, 50 GAL, Replace 10 4 6 1 EA $2,349.48 $2,349 $2,349 $2,349 $4,699
Beecher Community Center 7.2 612469 ADA, Restroom, Lavatory Pipe Wraps, Install 0 0 0 6 EA $75.90 $455 $455 $455
Beecher Community Center 7.4 612448 Distribution Panel, 208 Y, 120 V, 100 Amp, Replace 30 20 10 1 EA $5,079.93 $5,080 $5,080 $5,080
Beecher Community Center 7.4 612461 Distribution Panel, 208 Y, 120 V, 100 Amp, Replace 30 20 10 1 EA $5,079.93 $5,080 $5,080 $5,080
Beecher Community Center 7.4 612441 Main Distribution Panel, 208 Y, 120 V, 800 Amp, Replace 30 20 10 1 EA $13,423.81 $13,424 $13,424 $13,424
Beecher Community Center 7.4 612442 Distribution Panel, 208 Y, 120 V, 225 Amp, Replace 30 20 10 1 EA $7,951.00 $7,951 $7,951 $7,951
Beecher Community Center 7.4 612421 Metal Halide Lighting Fixture, 250 W, Replace 20 10 10 3 EA $748.18 $2,245 $2,245 $2,245
Beecher Community Center 7.4 612449 Lighting System, Interior, Upgrade 25 15 10 9423 SF $9.24 $87,087 $87,087 $87,087
Beecher Community Center 7.6 612450 Backflow Preventer, 6", Replace 15 5 10 1 EA $9,344.53 $9,345 $9,345 $9,345
Beecher Community Center 7.6 612433 Sprinkler Heads (per SF), Replace 20 17 3 9423 SF $1.33 $12,531 $12,531 $12,531
Beecher Community Center 7.6 612480 Fire Extinguisher, Replace 15 0 15 3 EA $356.54 $1,070 $1,070 $1,070
Beecher Community Center 7.6 612457 Fire Suppression System, Wet Chemical, Replace 15 12 3 1 EA $3,488.87 $3,489 $3,489 $3,489 $6,978
Beecher Community Center 7.6 612440 Fire Alarm System, Office Building, Upgrade 20 34 0 9423 SF $2.36 $22,234 $22,234 $22,234
Beecher Community Center 7.6 612434 Fire Alarm Control Panel, Addressable, Replace 15 34 0 1 EA $20,297.59 $20,298 $20,298 $20,298 $40,595
Beecher Community Center 7.6 612430 Emergency/Exit Combo, Replace 10 7 3 2 EA $687.51 $1,375 $1,375 $1,375 $2,750
Beecher Community Center 7.6 612427 Exit Lighting Fixture, Backlit, Replace 10 7 3 6 EA $405.01 $2,430 $2,430 $2,430 $4,860
Location Name
EMG
Renamed
Item
Number
ID Cost Description Lifespan
(EUL)EAge RUL QuantityUnit Unit Cost Subtotal 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036
Deficiency
Repair
Estimate
Beecher Community Center 8.1 612455 Interior Door, Wood Solid-Core, Replace 20 10 10 20 EA $1,423.11 $28,462 $28,462 $28,462
Beecher Community Center 8.1 612456 Interior Door, Fire 90-Minutes and Over, Replace 20 10 10 3 EA $1,649.06 $4,947 $4,947 $4,947
Beecher Community Center 8.1 612454 Interior Door, Fully-Glazed Aluminum-Framed Swinging, Replace 30 15 15 1 EA $2,106.57 $2,107 $2,107 $2,107
Beecher Community Center 8.1 612470 Toilet Partitions, Metal Overhead-Braced, Replace 20 10 10 5 EA $850.00 $4,250 $4,250 $4,250
Beecher Community Center 8.1 612311 Interior Wall Finish, Concrete/Masonry, Prep & Paint 8 4 4 4947 SF $1.45 $7,178 $7,178 $7,178 $14,356
Beecher Community Center 8.1 612312 Interior Wall Finish, Gypsum Board/Plaster/Metal, Prep & Paint 8 4 4 707 SF $1.42 $1,006 $1,006 $1,006 $2,012
Beecher Community Center 8.1 612320 Interior Wall Finish, Acoustical Tile (ACT) Fabric-Faced, Replace 20 10 10 707 SF $13.33 $9,424 $9,424 $9,424
Beecher Community Center 8.1 612327 Interior Floor Finish, Vinyl Tile (VCT), Replace 15 12 3 2827 SF $4.80 $13,571 $13,571 $13,571 $27,143
Beecher Community Center 8.1 612404 Interior Floor Finish, Quarry Tile, Replace 50 34 16 942 SF $15.19 $14,307 $14,307 $14,307
Beecher Community Center 8.1 612321 Interior Floor Finish, Carpet Standard-Commercial Medium-Traffic, Replace 10 7 3 5654 SF $7.26 $41,027 $41,027 $41,027 $82,054
Beecher Community Center 8.1 612409 Interior Ceiling Finish, Gypsum Board/Plaster, Prep & Paint 10 6 4 471 SF $1.94 $912 $912 $912 $1,824
Beecher Community Center 8.1 612406 Interior Ceiling Finish, Acoustical Tile (ACT), Replace 20 18 2 942 SF $3.11 $2,931 $2,931 $2,931
Beecher Community Center 8.1 612408 Interior Ceiling Finish, Acoustical Tile (ACT), Replace 20 5 15 754 SF $3.11 $2,346 $2,346 $2,346
Beecher Community Center 8.1 612431 Kitchen Cabinet, Base and Wall Section, Wood, Replace 20 15 5 80 LF $467.63 $37,411 $37,411 $37,411
Beecher Community Center 8.1 612432 Kitchen Counter, Plastic Laminate, Postformed, Replace 10 5 5 80 LF $43.90 $3,512 $3,512 $3,512 $7,023
Beecher Community Center 8.2 612459 Commercial Kitchen, Exhaust Hood, Replace 15 12 3 1 EA $7,571.72 $7,572 $7,572 $7,572 $15,143
Beecher Community Center 8.2 612460 Commercial Kitchen, Range/Oven, 6-Burner w/ Griddle, Replace 15 5 10 1 EA $9,288.00 $9,288 $9,288 $9,288
Totals, Unescalated $46,159 $119,962 $147,787 $234,809 $9,096 $85,150 $54,398 $0 $0 $0 $266,017 $0 $8,184 $44,832 $912 $62,178 $16,656 $0 $177,446 $0 $1,273,587
Totals, Escalated (3.0% inflation, compounded annually)$46,159 $123,560 $156,787 $256,582 $10,238 $98,712 $64,954 $0 $0 $0 $357,505 $0 $11,669 $65,838 $1,380 $96,871 $26,728 $0 $302,090 $0 $1,619,074
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1. Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
1.3. Special Issues and Follow-Up Recommendations ...................................................................... 3
1.4. Opinions of Probable Cost .......................................................................................................... 3
1.4.1. Methodology ................................................................................................................................ 4
1.4.2. Immediate Repairs ...................................................................................................................... 4
1.4.3. Replacement Reserves ............................................................................................................... 4
2. Purpose and Scope .............................................................................................................................. 5
2.1. Purpose ....................................................................................................................................... 5
2.2. Scope .......................................................................................................................................... 6
2.3. Personnel Interviewed ................................................................................................................. 6
2.4. Documentation Reviewed ........................................................................................................... 7
2.5. Pre-Survey Questionnaire ........................................................................................................... 7
2.6. Weather Conditions ..................................................................................................................... 7
3. Accessibility and Property Research ................................................................................................. 8
3.1. ADA Accessibility ........................................................................................................................ 8
3.2. Municipal Information, Flood Zone and Seismic Zone ................................................................ 8
4. Existing Building Assessment ............................................................................................................ 9
4.1. Unit or Space Types .................................................................................................................... 9
4.2. Inaccessible Areas or Key Spaces Not Observed ...................................................................... 9
5. Site Improvements ............................................................................................................................. 10
5.1. Utilities ....................................................................................................................................... 10
5.2. Parking, Paving, and Sidewalks ................................................................................................ 10
5.3. Drainage Systems and Erosion Control .................................................................................... 11
5.4. Topography and Landscaping ................................................................................................... 12
5.5. General Site Improvements ....................................................................................................... 12
6. Building Architectural and Structural Systems ............................................................................... 14
6.1. Foundations ............................................................................................................................... 14
6.2. Superstructure ........................................................................................................................... 14
6.3. Roofing ...................................................................................................................................... 14
6.4. Exterior Walls ............................................................................................................................ 15
6.5. Exterior and Interior Stairs ......................................................................................................... 16
6.6. Exterior Windows and Doors ..................................................................................................... 16
6.7. Patio, Terrace, and Balcony ...................................................................................................... 16
7. Building Mechanical and Plumbing Systems .................................................................................. 18
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC) ..................................................... 18
7.2. Building Plumbing and Domestic Hot Water ............................................................................. 18
7.3. Building Gas Distribution ........................................................................................................... 19
7.4. Building Electrical ...................................................................................................................... 20
7.5. Building Elevators and Conveying Systems .............................................................................. 20
7.6. Fire Protection and Security Systems ....................................................................................... 20
7.7. Life Support Systems ................................................................................................................ 21
8. Interior Spaces .................................................................................................................................... 22
8.1. Interior Finishes ......................................................................................................................... 22
8.2. Commercial Kitchen & Laundry Equipment .............................................................................. 23
9. Other Structures ................................................................................................................................. 24
10. Certification ......................................................................................................................................... 25
11. Appendices ......................................................................................................................................... 26
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
1
www.EMGcorp.com p 800.733.0660
1. Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 908 Game Farm Road, Yorkville, Kendall, Illinois 60560
Year Constructed/Renovated: 1982
Current Occupants: Village of Yorkville
Percent Utilization: 100%
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Municipal
Site Area: 2.55 acres
Building Area: 9,423 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of
Spaces: 94 spaces in open lots
Building Construction: Conventional wood frame structure on concrete slab
Roof Construction: Gabled roofs with asphalt shingles
Exterior Finishes: Brick veneer and metal siding
Heating, Ventilation and Air
Conditioning: Central system air handlers
Fire and Life/Safety:
Fire sprinklers, hydrants, smoke detectors, alarms, strobes,
extinguishers, pull stations, alarm panel, exit signs, and emergency
battery powered lights.
Dates of Visit: May 22, 2017 to May 23, 2017
On-Site Point of Contact (POC): Erin Willret
Assessment and Report
Prepared by: Paul Prusa
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
ahupp@emgcorp.com
800.733.0660 x6623
Systemic Condition Summary
Site Fair HVAC Fair
Structure Good Plumbing Fair
Roof Fair Electrical Fair
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
2
www.EMGcorp.com p 800.733.0660
Systemic Condition Summary
Vertical Envelope Fair Elevators --
Interiors Fair Fire Fair
The following bullet points highlight the most significant short term and modernization recommendations:
Full replacement of concrete sidewalks
Mill and overlay of asphalt parking lot
Modernization of the fire alarm system
ADA accessibility upgrades
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in fair overall condition.
According to property management personnel, the property has had a limited capital improvement expenditure program over the past
three years, primarily consisting of painting and sidewalk repairs. Supporting documentation was not provided in support of these
claims but some of the work is evident.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
Fci Condition
Rating Definition Percentage
Value
Good In new or well-maintained condition, with no visual evidence
of wear, soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and
functioning condition. > than 5% to 10%
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
3
www.EMGcorp.com p 800.733.0660
Fci Condition
Rating Definition Percentage
Value
Poor Subjected to hard or long-term wear. Nearing the end of its
useful or serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal
is now necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 2.6% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 61.8% Very Poor
Current Replacement Value (CRV) 9,423 SF * 183.24 / SF = $1,726,643
Year 0 (Current Year) - Immediate Repairs (IR) $46,159
Years 1-10 – Replacement Reserves (RR) $1,068,339
Total Capital Needs $1,114,498
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Full replacement of concrete sidewalks
Mill and overlay of asphalt parking lot
Modernization of the fire alarm system
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
1.3. Special Issues and Follow-Up Recommendations
As part of the FCA, a limited assessment of accessible areas of the building(s) was performed to determine the presence of fungal
growth, conditions conducive to fungal growth, and/or evidence of moisture. Property personnel were interviewed concerning any
known or suspected fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Sampling is not a part of this
assessment.
There are no visual indications of the presence of fungal growth, conditions conducive to fungal growth, or evidence of moisture in
representative readily accessible areas of the property.
1.4. Opinions of Probable Cost
Cost estimates are attached at the front of this report (following the cover page).
These estimates are based on Invoice or Bid Document/s provided either by the Owner/facility and construction costs developed by
construction resources such as R.S. Means and Marshall & Swift, EMG’s experience with past costs for similar properties, city cost
indexes, and assumptions regarding future economic conditions.
Opinions of probable costs should only be construed as preliminary, order of magnitude budgets. Actual costs most probably will vary
from the consultant’s opinions of probable costs depending on such matters as type and design of suggested remedy, quality of
materials and installation, manufacturer and type of equipment or system selected, field conditions, whether a physical deficiency is
repaired or replaced in whole, phasing of the work (if applicable), quality of contractor, quality of project management exercised, market
conditions, and whether competitive pricing is solicited, etc. ASTM E2018-08 recognizes that certain opinions of probable costs cannot
be developed within the scope of this guide without further study. Opinions of probable cost for further study should be included in the
FCA.
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
4
www.EMGcorp.com p 800.733.0660
1.4.1. Methodology
Based upon site observations, research, and judgment, along with referencing Expected Useful Life (EUL) tables from various industry
sources, EMG opines as to when a system or component will most probably necessitate replacement. Accurate historical replacement
records, if provided, are typically the best source of information. Exposure to the elements, initial quality and installation, extent of use,
the quality and amount of preventive maintenance exercised, etc., are all factors that impact the effective age of a system or
component. As a result, a system or component may have an effective age that is greater or less than its actual chronological age.
The Remaining Useful Life (RUL) of a component or system equals the EUL less its effective age. Projections of Remaining Useful Life
(RUL) are based on continued use of the Property similar to the reported past use. Significant changes in occupants and/or usage may
affect the service life of some systems or components.
Where quantities could not be derived from an actual take-off, lump sum costs or allowances are used. Estimated costs are based on
professional judgment and the probable or actual extent of the observed defect, inclusive of the cost to design, procure, construct and
manage the corrections.
1.4.2. Immediate Repairs
Immediate repairs are opinions of probable costs that require immediate action as a result of: (1) material existing or potential unsafe
conditions, (2) material building or fire code violations, or (3) conditions that, if not addressed, have the potential to result in, or
contribute to, critical element or system failure within one year or will most probably result in a significant escalation of its remedial cost.
1.4.3. Replacement Reserves
Replacement Reserves are for recurring probable expenditures, which are not classified as operation or maintenance expenses. The
replacement reserves should be budgeted for in advance on an annual basis. Replacement Reserves are reasonably predictable both
in terms of frequency and cost. However, Replacement Reserves may also include components or systems that have an
indeterminable life but, nonetheless, have a potential for failure within an estimated time period.
Replacement Reserves exclude systems or components that are estimated to expire after the reserve term and are not considered
material to the structural and mechanical integrity of the subject property. Furthermore, systems and components that are not deemed
to have a material effect on the use of the Property are also excluded. Costs that are caused by acts of God, accidents, or other
occurrences that are typically covered by insurance, rather than reserved for, are also excluded.
Replacement costs are solicited from ownership/property management, EMG’s discussions with service companies, manufacturers'
representatives, and previous experience in preparing such schedules for other similar facilities. Costs for work performed by the
ownership’s or property management’s maintenance staff are also considered.
EMG’s reserve methodology involves identification and quantification of those systems or components requiring capital reserve funds
within the assessment period. The assessment period is defined as the effective age plus the reserve term. Additional information
concerning system’s or component’s respective replacement costs (in today's dollars), typical expected useful lives, and remaining
useful lives were estimated so that a funding schedule could be prepared. The Replacement Reserves Schedule presupposes that all
required remedial work has been performed or that monies for remediation have been budgeted for items defined in the Immediate
Repair Cost Estimate.
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
5
www.EMGcorp.com p 800.733.0660
2. Purpose and Scope
2.1. Purpose
EMG was retained by the client to render an opinion as to the Property’s current general physical condition on the day of the site visit.
Based on the observations, interviews and document review outlined below, this report identifies significant deferred maintenance
issues, existing deficiencies, and material code violations of record at municipal offices, which affect the Property’s use. Opinions are
rendered as to its structural integrity, building system condition and the Property’s overall condition. The report also notes building
systems or components that have realized or exceeded their typical expected useful lives.
CONDITIONS:
The physical condition of building systems and related components are typically defined as being in one of five conditions: Excellent,
Good, Fair, Poor, Failed or a combination thereof. For the purposes of this report, the following definitions are used:
Excellent = New or very close to new; component or system typically has been installed within the past year, sound and
performing its function. Eventual repair or replacement will be required when the component or system either
reaches the end of its useful life or fails in service.
Good = Satisfactory as-is. Component or system is sound and performing its function, typically within the first third of its
lifecycle. However, it may show minor signs of normal wear and tear. Repair or replacement will be required
when the component or system either reaches the end of its useful life or fails in service.
Fair = Showing signs of wear and use but still satisfactory as-is, typically near the median of its estimated useful life.
Component or system is performing adequately at this time but may exhibit some signs of wear, deferred
maintenance, or evidence of previous repairs. Repair or replacement will be required due to the component or
system’s condition and/or its estimated remaining useful life.
Poor = Component or system is significantly aged, flawed, functioning intermittently or unreliably; displays obvious
signs of deferred maintenance; shows evidence of previous repair or workmanship not in compliance with
commonly accepted standards; has become obsolete; or exhibits an inherent deficiency. The present condition
could contribute to or cause the deterioration of contiguous elements or systems. Either full component
replacement is needed or repairs are required to restore to good condition, prevent premature failure, and/or
prolong useful life.
Failed
= Component or system has ceased functioning or performing as intended. Replacement, repair, or other
significant corrective action is recommended or required.
Not Applicable
= Assigning a condition does not apply or make logical sense, most commonly due to the item in question not
being present.
FORMAT OF THE BODY OF THE REPORT:
Throughout sections 5 through 9 of this report, each report section will typically contain three subsections organized in the following
sequence:
A descriptive table (and/or narrative), which identifies the components assessed, their condition, and other key data points.
A simple bulleted list of Anticipated Lifecycle Replacements, which lists components and assets typically in Excellent, Good, or Fair
condition at the time of the assessment but that will require replacement or some other attention once aged past their estimated
useful life. These listed components are typically included in the associated inventory database with costs identified and budgeted
beyond the first several years.
A bulleted cluster of Actions/Comments, which include more detailed narratives describing deficiencies, recommended repairs, and
short term replacements. The assets and components associated with these bullets are/were typically problematic and in Poor or
Failed condition at the time of the assessment, with corresponding costs included within the first few years.
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
6
www.EMGcorp.com p 800.733.0660
PLAN TYPES:
Each line item in the cost database is assigned a Plan Type, which is the primary reason or rationale for the recommended
replacement, repair, or other corrective action. This is the “why” part of the equation. A cost or line item may commonly have more
than one applicable Plan Type; however, only one Plan Type will be assigned based on the “best” fit, typically the one with the greatest
significance. The following Plan Types are listed in general weighted order of importance:
Safety = An observed or reported unsafe condition that if left unaddressed could result in an injury; a system
or component that presents a potential liability risk.
Performance/Integrity = Component or system has failed, is almost failing, performs unreliably, does not perform as
intended, and/or poses a risk to overall system stability.
Accessibility = Does not meet ADA, UFAS, and/or other handicap accessibility requirements.
Environmental = Improvements to air or water quality, including removal of hazardous materials from the building or
site.
Modernization/Adaptation
= Conditions, systems, or spaces that need to be upgraded in appearance or function to meet current
standards, facility usage, or client/occupant needs.
Lifecycle/Renewal
= Any component or system in which future repair or replacement is anticipated beyond the next
several years and/or is of minimal substantial early-term consequence.
2.2. Scope
The standard scope of the Facility Condition Assessment includes the following:
Visit the Property to evaluate the general condition of the building and site improvements, review available construction documents in
order to familiarize ourselves with, and be able to comment on, the in-place construction systems, life safety, mechanical, electrical,
and plumbing systems, and the general built environment.
Identify those components that are exhibiting deferred maintenance issues and provide cost estimates for Immediate Costs and
Replacement Reserves based on observed conditions, maintenance history and industry standard useful life estimates. This will
include the review of documented capital improvements completed within the last five-year period and work currently contracted for, if
applicable.
Provide a full description of the Property with descriptions of in-place systems and commentary on observed conditions.
Provide a general statement of the subject Property’s compliance to Title III of the Americans with Disabilities Act. This will not
constitute a full ADA survey, but will help identify exposure to issues and the need for further review.
Perform a limited assessment of accessible areas of the building(s) for the presence of fungal growth, conditions conducive to fungal
growth, and/or evidence of moisture. EMG will also interview Project personnel regarding the presence of any known or suspected
fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Potentially affected areas will be photographed.
Sampling will not be considered in routine assessments.
List the current utility service providers.
Review maintenance records and procedures with the in-place maintenance personnel.
Observe a representative sample of the interior spaces/units, including vacant spaces/units, in order to gain a clear understanding of
the property’s overall condition. Other areas to be observed include the exterior of the property, the roofs, interior common areas,
and the significant mechanical, electrical and elevator equipment rooms.
Provide an Executive Summary at the beginning of this report.
2.3. Personnel Interviewed
The management and building engineer were interviewed for specific information relating to the physical property, available
maintenance procedures, historical performance of key building systems and components, available drawings and other
documentation. The following personnel from the facility and government agencies were interviewed in the process of conducting the
FCA:
Name and Title Organization Phone Number
Erin Willret City of Yorkville 630.553.8574
The FCA was performed without the assistance of an onsite Point of Contact (POC).
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
7
www.EMGcorp.com p 800.733.0660
2.4. Documentation Reviewed
Prior to the FCA, relevant documentation was requested that could aid in the knowledge of the subject property’s physical
improvements, extent and type of use, and/or assist in identifying material discrepancies between reported information and observed
conditions. The review of submitted documents does not include comment on the accuracy of such documents or their preparation,
methodology, or protocol. The Documentation Request Form is provided in Appendix E.
Although Appendix E provides a summary of the documents requested or obtained, the following list provides more specific details
about some of the documents that were reviewed or obtained during the site visit.
No documents were available
2.5. Pre-Survey Questionnaire
A Pre-Survey Questionnaire was sent to the POC prior to the site visit. The questionnaire is included in Appendix E.
2.6. Weather Conditions
May 22, 2017: Clear, with temperatures in the 80s (°F) and light winds.
May 23, 2017: Raining, with temperatures in the 70s (°F) and light winds.
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
8
www.EMGcorp.com p 800.733.0660
3. Accessibility and Property Research
3.1. ADA Accessibility
Generally, Title III of the Americans with Disabilities Act (ADA) prohibits discrimination by entities to access and use of “areas of public
accommodations” and “commercial facilities” on the basis of disability. Regardless of its age, these areas and facilities must be
maintained and operated to comply with the Americans with Disabilities Act Accessibility Guidelines (ADAAG).
Buildings completed and occupied after January 26, 1992 are required to comply fully with the ADAAG. Existing facilities constructed
prior to this date are held to the lesser standard of compliance to the extent allowed by structural feasibility and the financial resources
available. As an alternative, a reasonable accommodation pertaining to the deficiency must be made.
During the FCA, a limited visual observation for ADA accessibility compliance was conducted. The scope of the visual observation was
limited to those areas set forth in EMG’s Abbreviated Accessibility Checklist provided in Appendix D of this report. It is understood by
the Client that the limited observations described herein does not comprise a full ADA Compliance Survey, and that such a survey is
beyond the scope of EMG’s undertaking. Only a representative sample of areas was observed and, other than as shown on the
Abbreviated Accessibility Checklist, actual measurements were not taken to verify compliance.
At an office property, the areas considered as a public accommodation besides the site itself and parking, are the exterior accessible
route, the interior accessible route up to the tenant lease lines and the interior common areas, including the common area restrooms.
The facility does not appear to be accessible with Title III of the Americans with Disabilities Act. Elements as defined by the ADAAG
that are not accessible as stated within the priorities of Title III, are as follows:
Parking
Adequate number of designated parking stalls and signage for vans are not provided.
Restrooms
Wrap drain pipes below lavatory with insulation; protect against contact with hot, sharp, or abrasive surfaces.
Add pull station alarm in unisex bathroom.
A full ADA Compliance Survey may reveal additional aspects of the property that are not in compliance.
Corrections of these conditions should be addressed from a liability standpoint, but are not necessarily code violations. The Americans
with Disabilities Act Accessibility Guidelines concern civil rights issues as they pertain to the disabled and are not a construction code,
although many local jurisdictions have adopted the Guidelines as such. The cost to address the achievable items noted above is
included in the cost tables.
3.2. Municipal Information, Flood Zone and Seismic Zone
Not applicable.
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
9
www.EMGcorp.com p 800.733.0660
4. Existing Building Assessment
4.1. Unit or Space Types
All 9,423 square feet of the building are occupied by a single occupant, City of Yorkville. The spaces are a combination of offices,
recreation rooms, kitchen, supporting restrooms, mechanical, and other utility spaces.
4.2. Inaccessible Areas or Key Spaces Not Observed
The interior spaces were observed in order to gain a clear understanding of the property’s overall condition. Other areas accessed
included the site within the property boundaries, exterior of the property and the roof. All areas of the property were available for
observation during the site visit.
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
10
www.EMGcorp.com p 800.733.0660
5. Site Improvements
5.1. Utilities
The following table identifies the utility suppliers and the condition and adequacy of the services.
Site Utilities
Utility Supplier Condition and Adequacy
Sanitary sewer City of Yorkville Good
Storm sewer City of Yorkville Good
Domestic water City of Yorkville Good
Electric service Commonwealth Edison Good
Natural gas service Nicor Gas Good
Actions/Comments:
According to the POC, the utilities provided are adequate for the property. There are no unique, onsite utility systems such as
emergency electrical generators, septic systems, water or waste water treatment plants, or propane gas tanks.
5.2. Parking, Paving, and Sidewalks
Item Description
Main Ingress and Egress Game Farm Road
Access from West
Additional Entrances Library Parking Lot
Additional Access from South
Paving and Flatwork
Item Material Last Work Done Condition
Entrance Driveway Apron Asphalt Less than 5 years Good
Parking Lot Asphalt More than 20 years Poor
Drive Aisles Asphalt More than 20 years Poor
Service Aisles None -- --
Sidewalks Concrete More than 20 years Poor
Curbs Concrete More than 20 years Poor
Site Stairs None -- --
Pedestrian Ramps None -- --
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
11
www.EMGcorp.com p 800.733.0660
Parking Count
Open Lot Carport Private Garage Subterranean
Garage
Freestanding Parking
Structure
94 -- -- -- --
Total Number of ADA Compliant Spaces 4
Number of ADA Compliant Spaces for Vans 0
Total Parking Spaces 94
Parking Ratio (Spaces/Apartments) --
Method of Obtaining Parking Count Physical count
Exterior Stairs
Location Material Handrails Condition
None -- -- --
Anticipated Lifecycle Replacements:
Asphalt seal coating
Asphalt pavement
Sidewalks
Curbs
Actions/Comments:
The asphalt pavement exhibits significant areas of failure and deterioration, such as alligator cracking, transverse cracking and heavy
overall surface wear. All of the paving must be overlaid with new asphalt paving in order to maintain the integrity of the overall
pavement system. Milling is recommended as part of the overall repair work.
The concrete sidewalks and curbs have significant areas of cracking concrete curbs and sidewalks. These areas occur throughout
the property. The damaged areas of concrete curbs and sidewalks require replacement.
5.3. Drainage Systems and Erosion Control
Drainage System and Erosion Control
System Exists At Site Condition
Surface Flow ☐ --
Inlets ☒ Good
Swales ☐ --
Detention pond ☐ --
Lagoons ☐ --
Ponds ☐ --
Underground Piping ☒ Good
Pits ☐ --
Municipal System ☒ Good
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
12
www.EMGcorp.com p 800.733.0660
Drainage System and Erosion Control
System Exists At Site Condition
Dry Well ☐ --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
There is no evidence of storm water runoff from adjacent properties. The storm water system appears to provide adequate runoff
capacity. There is no evidence of major ponding or erosion.
5.4. Topography and Landscaping
Item Description
Site Topography Generally flat
Landscaping
Trees Grass Flower
Beds Planters
Drought
Tolerant
Plants
Decorative
Stone None
☒ ☒ ☒ ☐ ☒ ☒ ☐
Landscaping
Condition Good
Irrigation
Automatic
Underground Drip Hand Watering None
☐ ☐ ☐ ☒
Irrigation Condition --
Retaining Walls
Type Location Condition
Stone masonry Around light poles Poor
Anticipated Lifecycle Replacements:
Stone retaining walls
Actions/Comments:
The retaining walls appear problematic. The stones have been removed and are damaged. Damaged portions of the retaining walls
must be replaced.
5.5. General Site Improvements
Property Signage
Property Signage Monument
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
13
www.EMGcorp.com p 800.733.0660
Property Signage
Street Address Displayed? Yes
Site and Building Lighting
Site Lighting
None Pole Mounted Bollard Lights Ground
Mounted
Parking Lot
Pole Type
☐ ☒ ☐ ☐ ☐
Fair
Building Lighting
None Wall Mounted Recessed Soffit
☐ ☒ ☐
Fair
Site Fencing
Type Location Condition
None -- --
REFUSE DISPOSAL
Refuse Disposal Individual garbage bins
Dumpster Locations Mounting Enclosure Contracted? Condition
-- None None Yes --
Other Site Amenities
Description Location Condition
Playground Equipment None -- --
Tennis Courts None -- --
Basketball Court None -- --
Swimming Pool None -- --
Anticipated Lifecycle Replacements:
Signage
Exterior lighting
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
14
www.EMGcorp.com p 800.733.0660
6. Building Architectural and Structural Systems
6.1. Foundations
Building Foundation
Item Description Condition
Foundation Concrete spread footings Good
Basement and Crawl Space None --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The foundation systems are concealed. There are no significant signs of settlement, deflection, or movement.
6.2. Superstructure
Building Superstructure
Item Description Condition
Framing / Load-Bearing Walls Conventional wood/metal studs Good
Ground Floor Concrete slab Good
Upper Floor Framing -- --
Upper Floor Decking -- --
Roof Framing Heavy lumber beams Good
Roof Decking Plywood or OSB Good
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The superstructure is exposed in some locations, which allows for limited observation. Walls and floors appear to be plumb, level,
and stable. There are no significant signs of deflection or movement.
6.3. Roofing
Primary Roof
Type / Geometry Multiple Gable Roofs Finish Asphalt shingles
Maintenance Outside Contractor Roof Age Approximately 15 Yrs
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
15
www.EMGcorp.com p 800.733.0660
Primary Roof
Flashing Sheet metal Warranties No
Parapet Copings None Roof Drains Gutters and downspouts
Fascia None Insulation Fiberglass batts
Soffits Concealed Soffits Skylights No
Attics Wood joists with plywood
sheathing Ponding No
Ventilation Source-1 Ridge Vents Leaks Observed No
Ventilation Source-2 Soffit Vents Roof Condition Poor
Anticipated Lifecycle Replacements:
Asphalt shingles
Roof flashings (included as part of overall replacement)
Actions/Comments:
The roof finishes appear to be more than 15 years old. Information regarding roof warranties or bonds was not available.
There are no active roof leaks observed. There is no evidence of active roof leaks. Roof leaks appear to have occurred in the past.
The leaks have since been repaired, and no active roof leaks are evident.
Roof drainage appears to be adequate. Clearing and minor repair of drain system components should be performed regularly as part
of the property management’s routine maintenance and operations program.
The attics are not accessible and it could not be determined if there is moisture, water intrusion, or excessive daylight in the attics.
6.4. Exterior Walls
Building Exterior Walls
Type Location Condition
Primary Finish Brick veneer Fair
Secondary Finish Metal siding Fair
Accented with -- --
Soffits Concealed Fair
Building sealants (caulking) are located between dissimilar materials, at joints, and around window and door openings.
Anticipated Lifecycle Replacements:
Metal siding
Masonry re-pointing
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance, including patching repairs, graffiti removal,
and re-caulking, is highly recommended. Future lifecycle replacements of the components listed above will be required.
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
16
www.EMGcorp.com p 800.733.0660
6.5. Exterior and Interior Stairs
Not applicable. There are no exterior or interior stairs.
6.6. Exterior Windows and Doors
Building Windows
Window Framing Glazing Location Window
Screen Condition
Aluminum framed, fixed Double glaze Exterior walls ☐ Fair
Aluminum framed, operable Double glaze Exterior walls ☐ Fair
Aluminum framed, fixed,
sidelight Single glaze Exterior doors ☐ Poor
Building Doors
Main Entrance Doors Door Type Condition
Fully glazed, metal framed Fair
Secondary Entrance Doors Fully glazed, metal framed Fair
Service Doors -- --
Overhead Doors -- --
Anticipated Lifecycle Replacements:
Windows
Exterior fully glazed doors
Actions/Comments:
The sidelight windows are antiquated, energy-inefficient units with single-pane glazing. Window replacement is recommended.
6.7. Patio, Terrace, and Balcony
Building Patio, Terrace and Balcony
Type Description Location Condition
Ground Floor Patio Brick pavers Right side Fair
Upper Balcony Structure -- -- --
Balcony Decks -- -- --
Balcony Deck Toppings -- -- --
Balcony Guardrails -- -- --
Anticipated Lifecycle Replacements:
Brick pavers
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
17
www.EMGcorp.com p 800.733.0660
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
18
www.EMGcorp.com p 800.733.0660
7. Building Mechanical and Plumbing Systems
See the Mechanical Equipment List in the Appendices for the quantity, manufacturer’s name, model number, capacity and year of
manufacturer of the major mechanical equipment, if available.
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC)
Distribution System
Air Distribution System Constant volume
Quantity and Capacity of Air Handlers 3 air handlers ranging from approximately 5,000 to 11,000
CFM
Location of Air Handlers Rooftop, penthouse
Large Spaces the Larger Dedicated AHU’s Serve Recreation Room, Kitchen
Age of Air Handlers All units appear to be original 1982 equipment
Air Handler Condition Fair
Controls and Ventilation
HVAC Control System Individual non-programmable thermostats/controls
HVAC Control System Condition Fair
Building Ventilation Roof top exhaust fans
Ventilation System Condition Fair
Anticipated Lifecycle Replacements:
Air handling units
Rooftop exhaust fans
Actions/Comments:
The HVAC systems are maintained by the in-house maintenance staff. Records of the installation, maintenance, upgrades, and
replacement of the HVAC equipment at the property have been maintained since the property was first occupied.
Approximately all of the HVAC equipment is original.
The HVAC equipment appears to be functioning adequately overall. The engineering staff was interviewed about the historical and
recent performance of the equipment and systems. No chronic problems were reported and an overall sense of satisfaction with the
systems was conveyed. However, due to the inevitable failure of parts and components over time, some of the equipment will
require replacement. A budgetary cost for this work is included.
7.2. Building Plumbing and Domestic Hot Water
Building Plumbing System
Type Description Condition
Water Supply Piping Copper Fair
Waste/Sewer Piping Cast iron Fair
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
19
www.EMGcorp.com p 800.733.0660
Building Plumbing System
Type Description Condition
Vent Piping Cast iron and PVC Fair
Water Meter Location Fire Sprinkler Room
Domestic Water Heaters or Boilers
Components Water Heater
Fuel Natural gas
Quantity and Input Capacity 1 unit at 40,000 BTUH
Storage Capacity 50 gallons
Boiler or Water Heater Condition Good
Supplementary Storage Tanks? No
Storage Tank Quantity and Volume --
Quantity of Storage Tanks --
Storage Tank Condition --
Domestic Hot Water Circulation Pumps (3 HP and over) No
Adequacy of Hot Water Adequate
Adequacy of Water Pressure Adequate
Plumbing Fixtures
Water Closets Commercial grade
Toilet (Water Closet) Flush Rating 1.6 GPF
Common Area Faucet Nominal Flow Rate 2.0 GPM
Condition Fair
Anticipated Lifecycle Replacements:
Water heaters
Toilets
Urinals
Sinks
Lavatories
Actions/Comments:
The plumbing systems appear to be well maintained and functioning adequately. The water pressure appears to be sufficient. No
significant repair actions or short term replacement costs are required. Routine and periodic maintenance is recommended. Future
lifecycle replacements of the components or systems listed above will be required.
7.3. Building Gas Distribution
Gas service is supplied from the gas main on the adjacent public street. The gas meter and regulator location could not be determined.
The gas distribution piping within the building is malleable steel (black iron).
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
20
www.EMGcorp.com p 800.733.0660
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The pressure and quantity of gas appear to be adequate.
Only limited observation of the gas distribution piping can be made due to hidden conditions.
7.4. Building Electrical
Building Electrical Systems
Electrical Lines Underground Transformer Pad-mounted
Main Service Size 800 Amps Volts 120/208 Volt, three-phase
Meter and Panel Location Front of building Branch Wiring Copper
Conduit Metallic Step-Down
Transformers? No
Security / Surveillance
System? No Building Intercom
System? No
Lighting Fixtures T-12
Main Distribution Condition Fair
Secondary Panel and
Transformer Condition Fair
Lighting Condition Fair
Anticipated Lifecycle Replacements:
Circuit breaker panels
Interior light fixtures
Actions/Comments:
The onsite electrical systems up to the meters are owned and maintained by the respective utility company.
The electrical service and capacity appear to be adequate for the property’s demands.
The panels are mostly original 1982 components. The electrical service is reportedly adequate for the facility’s needs. However, due
to the age of the panels and increasing difficulty of obtaining replacement parts over time, lifecycle replacements are recommended
per above.
7.5. Building Elevators and Conveying Systems
Not applicable. There are no elevators or conveying systems.
7.6. Fire Protection and Security Systems
Item Description
Type Wet pipe
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
21
www.EMGcorp.com p 800.733.0660
Item Description
Type Wet pipe
Fire Alarm System
Central Alarm Panel ☒ Battery-Operated Smoke
Detectors ☐ Alarm Horns ☒
Annunciator Panels ☐ Hard-Wired Smoke
Detectors ☒ Strobe Light Alarms ☒
Pull Stations ☒ Emergency Battery-Pack
Lighting ☒ Illuminated EXIT Signs ☒
Alarm System
Condition Poor
Sprinkler System
None ☐ Standpipes ☐ Backflow Preventer ☒
Hose Cabinets ☐ Fire Pumps ☐ Siamese Connections ☒
Suppression
Condition Fair
Central Alarm Panel
System
Location of Alarm Panel Installation Date of Alarm Panel
Fire Alarm Room 1982
Fire Extinguishers
Last Service Date Servicing Current?
02/2017 Yes
Hydrant Location Rear of building
Siamese Location Rear Elevation
Special Systems Kitchen Suppression System ☒Computer Room Suppression System ☐
Anticipated Lifecycle Replacements:
Central alarm panel
Alarm devices and system
Sprinkler heads
Actions/Comments:
The fire alarm systems appear somewhat antiquated and not up to current standards. A lack of strobes and audio alarms was
present in the restrooms. Due to the age of the components and apparent shortcomings, a full modernization project is
recommended. A budgetary cost is included.
The central alarm panel appears to be original and of the relay style. Based on its age and because replacement parts and
components for this type of equipment may be obsolete, the alarm panel requires replacement.
7.7. Life Support Systems
Not applicable.
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
22
www.EMGcorp.com p 800.733.0660
8. Interior Spaces
8.1. Interior Finishes
The facility is used as a senior community center for the City of Yorkville.
The most significant interior spaces include recreation spaces, offices, kitchen, and main entrance lobby. Supporting areas include
hallways, restrooms, mechanical penthouse, and utility closet.
The following table generally describes the locations and typical conditions of the interior finishes within the facility:
Typical Floor Finishes
Floor Finish Locations General Condition
Vinyl tile Recreation rooms Fair
Carpet Offices, recreation rooms Fair
Quarry tile Lobby, restrooms, kitchen Fair
Typical Wall Finishes
Wall Finish Locations General Condition
Painted CMU Offices, restrooms, utility closets Fair
Exposed CMU/masonry Lobby, recreation rooms, kitchen, recreation
rooms, offices Fair
Painted drywall Offices Fair
Fabric panels Recreation room Fair
Typical Ceiling Finishes
Ceiling Finish Locations General Condition
Suspended T-bar (Acoustic) Lobby, kitchen, restrooms Fair
Painted drywall Offices, recreation rooms Fair
Exposed structure Recreation rooms, offices Fair
Interior Doors
Item Type Condition
Interior Doors Solid core wood Fair
Door Framing Metal Fair
Fire Doors Yes Fair
Anticipated Lifecycle Replacements:
Carpet
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
23
www.EMGcorp.com p 800.733.0660
Vinyl tile
Quarry tile
Interior paint
Suspended acoustic ceiling tile
Interior doors
Actions/Comments:
It appears that the interior finishes are original.
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
8.2. Commercial Kitchen & Laundry Equipment
The kitchen area has a variety of commercial kitchen appliances, fixtures, and equipment. The equipment is owned and maintained in-
house and by the tenants. The tenants are responsible for any necessary replacement costs of their equipment only.
The kitchen includes the following major appliances, fixtures, and equipment:
Commercial Kitchen
Appliance Comment Condition
Refrigerators (tenant owned) Up-right Good
Freezers (tenant owned) Up-right Good
Ranges Gas Fair
Ovens Gas Fair
Griddles / Grills Gas Fair
Fryers ☐ --
Hood Exhaust ducted to exterior Fair
Dishwasher ☐ --
Microwave ☐ --
Ice Machines ☐ --
Steam Tables ☐ --
Work Tables ☒ Good
Shelving ☐ --
Anticipated Lifecycle Replacements:
Cooking Range /Oven/Grill
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
24
www.EMGcorp.com p 800.733.0660
9. Other Structures
Not applicable. There are no major accessory structures.
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
25
www.EMGcorp.com p 800.733.0660
10. Certification
City of Yorkville retained EMG to perform this Facility Condition Assessment in connection with its continued operation of Beecher
Community Center, 908 Game Farm Road, Yorkville, Illinois, the “Property”. It is our understanding that the primary interest of City of
Yorkville is to locate and evaluate materials and building system defects that might significantly affect the value of the property and to
determine if the present Property has conditions that will have a significant impact on its continued operations.
The conclusions and recommendations presented in this report are based on the brief review of the plans and records made available
to our Project Manager during the site visit, interviews of available property management personnel and maintenance contractors
familiar with the Property, appropriate inquiry of municipal authorities, our Project Manager’s walk-through observations during the site
visit, and our experience with similar properties.
No testing, exploratory probing, dismantling or operating of equipment or in depth studies were performed unless specifically required
under Section 2 of this report. This assessment did not include engineering calculations to determine the adequacy of the Property’s
original design or existing systems. Although walk-through observations were performed, not all areas were observed (See Section 4.2
for areas observed). There may be defects in the Property, which were in areas not observed or readily accessible, may not have been
visible, or were not disclosed by management personnel when questioned. The report describes property conditions at the time that
the observations and research were conducted.
This report has been prepared on behalf of and exclusively for the use of City of Yorkville for the purpose stated within Section 2 of this
report. The report, or any excerpt thereof, shall not be used by any party other than City of Yorkville or for any other purpose than that
specifically stated in our agreement or within Section 2 of this report without the express written consent of EMG.
Any reuse or distribution of this report without such consent shall be at City of Yorkville and the recipient’s sole risk, without liability to
EMG.
Prepared by: Paul Prusa P.E., LEED AP,
Project Manager
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
ahupp@emgcorp.com
800.733.0660 x6623
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
26
www.EMGcorp.com p 800.733.0660
11. Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: Supporting Documentation
Appendix D: EMG Accessibility Checklist
Appendix E: Pre-Survey Questionnaire
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
Beecher Community Center EMG PROJECT NO: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: RIGHT ELEVATION
#3: LEFT ELEVATION
#4: REAR ELEVATION
#5: SIDEWALK
#6: DETERIORATING SIDEWALK
AND REPAIRED CRACKS
Beecher Community Center EMG PROJECT NO: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
#7: PARKING LOTS, ASPHALT
PAVEMENT
#8:
SIGNIFICANT CRACKING AND
DETERIORATION OF PARKING
LOT
#9: HIGH PRESSURE SODIUM
LIGHTING FIXTURE
#10: FLAGPOLE
#11: POLE LIGHT
#12: SIGNAGE
Beecher Community Center EMG PROJECT NO: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
#13: ROOF, ASPHALT SHINGLE
#14: EXTERIOR WALL, ALUMINUM
SIDING
#15:
EXTERIOR DOOR, FULLY-
GLAZED ALUMINUM-FRAMED
SWINGING
#16: WINDOW, ALUMINUM DOUBLE-
GLAZED OPERABLE
#17: WINDOW, ALUMINUM DOUBLE-
GLAZED FIXED
#18:
PEDESTRIAN PAVEMENT,
SIDEWALK, CLAY
BRICK/MASONRY PAVERS
Beecher Community Center EMG PROJECT NO: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
#19: EXHAUST FAN
#20: AIR HANDLER
#21: WATER HEATER
#22: SINK, MULTI-COMPARTMENT
#23: LAVATORY
#24: SINK, STAINLESS STEEL
Beecher Community Center EMG PROJECT NO: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
#25: DRINKING FOUNTAIN,
REFRIGERATED
#26: TOILET, TANKLESS (WATER
CLOSET)
#27: SERVICE SINK
#28: LIGHTING
#29: MAIN DISTRIBUTION PANEL
#30: METAL HALIDE LIGHTING
FIXTURE
Beecher Community Center EMG PROJECT NO: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
#31: EMERGENCY/EXIT LIGHT
COMBO
#32: FIRE EXTINGUISHER
#33: BACKFLOW PREVENTER, FIRE
#34: FIRE ALARM CONTROL PANEL,
ADDRESSABLE
#35: FIRE ALARM DEVICES
#36: SPRINKLER HEAD
Beecher Community Center EMG PROJECT NO: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
#37: FIRE SUPPRESSION SYSTEM,
WET CHEMICAL
#38: VINYL TILE (VCT)
#39: CARPET
#40: TOILET PARTITIONS
#41:
INTERIOR WALL FINISH,
ACOUSTICAL TILE (ACT)
FABRIC-FACED
#42: INTERIOR CEILING FINISH,
GYPSUM BOARD/PLASTER
Beecher Community Center EMG PROJECT NO: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
#43: INTERIOR WALL FINISH,
CONCRETE/MASONRY
#44: QUARRY TILE
#45: INTERIOR CEILING FINISH,
ACOUSTICAL TILE (ACT)
#46: WATER STAINED ACOUSTICAL
TILES
#47: INTERIOR WALL FINISH
#48:
INTERIOR DOOR, FULLY-
GLAZED ALUMINUM-FRAMED
SWINGING
Beecher Community Center EMG PROJECT NO: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
#49: INTERIOR DOOR, WOOD SOLID-
CORE
#50: INTERIOR DOOR, FIRE 90-
MINUTES AND OVER
#51: KITCHEN CABINET
#52:
COMMERCIAL KITCHEN,
RANGE/OVEN, 6-BURNER WITH
GRIDDLE
#53: COMMERCIAL KITCHEN,
EXHAUST HOOD
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Beecher Community Center
Project Number:
122700.17R000-005.322
Source:
Google Maps
On-Site Date:
May 23, 2017
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
Appendix C:
EMG Accessibility Checklist
Page 1 of 4
Date Completed: June 7, 2017
Property Name: Beecher Community Center
EMG Project Number: 122700.17R000-005.322
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X However no spaces are designated for vans.
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X No designated van spaces.
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
3
Does the width between railings appear at
least 36 inches? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms (cont.) Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
Appendix D:
Pre-Survey Questionnaire
PROPERTY CONDITION ASSESSMENT : PRE-SURVEY QUESTIONNAIRE
Name of Person Completing Questionnaire:N/A - Not returned to EMG
Association with Property:
Length of Assocation with Property:
Date Completed:
Phone Number:
Property Name:
EMG Project Number:
Inspections Date Last
Inspected
List any Outstanding Repairs Required
1 Elevators
2 HVAC, Mechanical,
Electric, Plumbing
3 Life-Safety/Fire
4 Roofs
Question Response
5 List any major capital improvement within
the last three years.
6 List any major capital expenditures
planned for the next year.
7 What is the age of the roof(s)?
8 What building systems (HVAC, roof,
interior/exterior finishes, paving, etc.) are
the responsibilities of the tenant to
maintain and replace?
Question Yes No Unk N/A Comments
9
Are there any unresolved building, fire, or
zoning code issues?
10 Are there any "down" or unusable units?
11
Are there any problems with erosion,
stormwater drainage or areas of paving that
do not drain?
12
Is the property served by a private water
well?
13
Is the property served by a private septic
system or other waste treatment systems?
14
Are there any problems with foundations or
structures?
15
Is there any water infiltration in basements or
crawl spaces?
16 Are there any wall, or window leaks?
17 Are there any roof leaks?
18 Is the roofing covered by a warranty or bond?
19 Are there any poorly insulated areas?
20
Is Fire Retardant Treated (FRT) plywood
used?
PROPERTY CONDITION ASSESSMENT : PRE-SURVEY QUESTIONNAIRE
Question Yes No Unk N/A Comments
21
Is exterior insulation and finish system (EIFS)
or a synthetic stucco finish used?
22
Are there any problems with the utilities, such
as inadequate capacities?
23
Are there any problems with the landscape
irrigation systems?
24
Has a termite/wood boring insect inspection
been performed within the last year?
25
Do any of the HVAC systems use R-11, 12,
or 22 refrigerants?
26
Has any part of the property ever contained
visible suspect mold growth?
27
Is there a mold Operations and Maintenance
Plan?
28
Have there been indoor air quality or mold
related complaints from tenants?
29 Is polybutylene piping used?
30
Are there any plumbing leaks or water
pressure problems?
31
Are there any leaks or pressure problems
with natural gas service?
32
Does any part of the electrical system use
aluminum wiring?
33
Do Residential units have a less than
60-Amp service?
34
Do Commercial units have less than
200-Amp service?
35
Are there any recalled fire sprinkler heads
(Star, GEM, Central, Omega)?
36
Is there any pending litigation concerning the
property?
37
Has the management previously completed
an ADA review?
38
Have any ADA improvements been made to
the property?
39
Does a Barrier Removal Plan exist for the
property?
40
Has the Barrier Removal Plan been approved
by an arms-length third party?
41
Has building ownership or management
received any ADA related complaints?
42
Does elevator equipment require upgrades to
meet ADA standards?
43 Are there any problems with exterior lighting?
44
Are there any other significant
issues/hazards with the property?
PROPERTY CONDITION ASSESSMENT : PRE-SURVEY QUESTIONNAIRE
Question Yes No Unk N/A Comments
45
Are there any unresolved construction
defects at the property?
Comments
BEECHER COMMUNITY CENTER EMG PROJECT NO.: 122700.17R000-005.322
www.EMGcorp.com p 800.733.0660
On the day of the site visit, provide EMG's Field Observer access to all of the available documents listed below.
Provide copies if possible.
INFORMATION REQUIRED
1. All available construction documents (blueprints) for
the original construction of the building or for any tenant
improvement work or other recent construction work.
2. A site plan, preferably 8 1/2" X 11", which depicts the
arrangement of buildings, roads, parking stalls, and other
site features.
3. For commercial properties, provide a tenant list which
identifies the names of each tenant, vacant tenant units,
the floor area of each tenant space, and the gross and
net leasable area of the building(s).
4. For apartment properties, provide a summary of the
apartment unit types and apartment unit type quantities,
including the floor area of each apartment unit as
measured in square feet.
5. For hotel or nursing home properties, provide a
summary of the room types and room type quantities.
6. Copies of Certificates of Occupancy, building permits,
fire or health department inspection reports, elevator
inspection certificates, roof or HVAC warranties, or any
other similar, relevant documents.
7. The names of the local utility companies which serve
the property, including the water, sewer, electric, gas,
and phone companies.
8. The company name, phone number, and contact
person of all outside vendors who serve the property,
such as mechanical contractors, roof contractors, fire
sprinkler or fire extinguisher testing contractors, and
elevator contractors.
9. A summary of recent (over the last 5 years) capital
improvement work which describes the scope of the
work and the estimated cost of the improvements.
Executed contracts or proposals for improvements.
Historical costs for repairs, improvements, and
replacements.
10. Records of system and material ages (roof, MEP,
paving, finishes, furnishings).
11. Any brochures or marketing information.
12. Appraisal, either current or previously prepared.
13. Current occupancy percentage and typical turnover
rate records (for commercial and apartment properties).
14. Previous reports pertaining to the physical condition
of property.
15. ADA survey and status of improvements
implemented.
16. Current / pending litigation related to property
condition.
Your timely compliance with this request is greatly appreciated.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Beecher Storage Shed
908 Game Farm Road
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-006.366 June 13, 2017 May 22, 2017
FACILITY CONDITION ASSESSMENT
BEECHER STORAGE SHED EMG PROJECT NO.: 122700.17R000-006.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
BEECHER STORAGE SHED EMG PROJECT NO.: 122700.17R000-006.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 908 Game Farm Road, Yorkville, Kendall, Illinois 60560
Year Constructed/Renovated: 2004
Current Occupants: Parks and Recreation
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Garage
Site Area: 0.01 acres
Building Area: 560 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: Not applicable
Building Construction: Conventional wood frame structure on concrete slab
Roof Construction: Gabled roof with asphalt shingles
Exterior Finishes: Vinyl Siding
Heating, Ventilation and Air Conditioning: Not applicable
Fire and Life/Safety: Not applicable
Dates of Visit: May 22, 2017
On-Site Point of Contact (POC): Scott Sleezer
Assessment and Report Prepared by: Paul Prusa
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Good HVAC --
Structure Good Plumbing --
Roof Fair Electrical --
Vertical Envelope Fair Elevators --
Interiors Fair Fire --
BEECHER STORAGE SHED EMG PROJECT NO.: 122700.17R000-006.366
2
www.EMGcorp.com p 800.733.0660
The following bullet points highlight the most significant short term and modernization recommendations:
None
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in good overall condition.
The property has had no major capital improvements. The property is less than 13 years old and has not required any major capital
improvements.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
BEECHER STORAGE SHED EMG PROJECT NO.: 122700.17R000-006.366
3
www.EMGcorp.com p 800.733.0660
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.0% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 31.9% Poor
Current Replacement Value (CRV) 560 SF * 183.24 / SF = $9,162
Year 0 (Current Year) - Immediate Repairs (IR) $0.00
Years 1-10 – Replacement Reserves (RR) $2,925
Total Capital Needs $2,925
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
No immediate needs were identified.
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
BEECHER STORAGE SHED EMG PROJECT NO.: 122700.17R000-006.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: ADA Checklist
BEECHER STORAGE SHED EMG PROJECT NO.: 122700.17R000-006.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
Beecher Storage Shed
908 Game Farm Road
Yorkville, Illinois 60560 EMG PROJECT NO: 122700.17R000-006.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: LEFT ELEVATION
#3: RIGHT ELEVATION
#4: REAR ELEVATION
#5: PEDESTRIAN PAVEMENT,
SIDEWALK, CONCRETE
#6: STRUCTURAL FRAME, WOOD
CONVENTIONAL STUD
Beecher Storage Shed
908 Game Farm Road
Yorkville, Illinois 60560 EMG PROJECT NO: 122700.17R000-006.366
www.EMGcorp.com p 800.733.0660
#7: FOUNDATIONS, CONCRETE
SLAB-ON-GRADE
#8: ROOF, ASPHALT SHINGLE
#9: EXTERIOR WALL, VINYL SIDING
#10: DAMAGED VINYL SIDING,
LOWER REAR ELEVATION
#11: OVERHEAD DOOR, ALUMINUM
ROLL-UP
#12: EXTERIOR DOOR, STEEL
Beecher Storage Shed
908 Game Farm Road
Yorkville, Illinois 60560 EMG PROJECT NO: 122700.17R000-006.366
www.EMGcorp.com p 800.733.0660
#13: INTERIOR - GENERAL
BEECHER STORAGE SHED EMG PROJECT NO.: 122700.17R000-006.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Beecher Storage Shed
Project Number:
122700.17R000-006.366
Source:
Google Maps
On-Site Date:
May 22, 2017
BEECHER STORAGE SHED EMG PROJECT NO.: 122700.17R000-006.366
www.EMGcorp.com p 800.733.0660
Appendix C:
ADA Checklist
Page 1 of 4
Date Completed: June 5, 2017
Property Name: Beecher Storage Shed
EMG Project Number: 122700.17R000-006.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Beecher Concession Stand
908 Game Farm Road
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-007.366 September 13, 2017 May 22, 2017
FACILITY CONDITION ASSESSMENT
Immediate Repairs Report
Beecher Concession Stand
9/13/2017
Location Name EMG Renamed Item NumberID Cost Description QuantityUnit Unit CostSubtotalDeficiency Repair Estimate *
Beecher Concession Stand 3.1 611358 ADA, Door, Lever Handle Hardware, Install 2 EA $202.40 $405 $405
Beecher Concession Stand 5.2 611442 Pedestrian Pavement, Sidewalk, Asphalt, Repair 100 SF $1.60 $160 $160
Immediate Repairs Total $565
* Location Factor included in totals.
Replacement Reserves Report
Beecher Concession Stand
9/13/2017
Location Name EMG Renamed
Item Number ID Cost Description
Lifespan
(EUL)EAge RUL QuantityUnit Unit Cost Subtotal 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036
Deficiency
Repair
Estimate
Beecher Concession Stand 3.1 611358 ADA, Door, Lever Handle Hardware, Install 0 0 0 2 EA $202.40 $405 $405 $405
Beecher Concession Stand 5.2 611442 Pedestrian Pavement, Sidewalk, Asphalt, Repair 25 25 0 100 SF $1.60 $160 $160 $160
Beecher Concession Stand 5.2 611406 Pedestrian Pavement, Sidewalk, Asphalt, Seal 5 2 3 4780 SF $0.38 $1,814 $1,814 $1,814 $1,814 $1,814 $7,256
Beecher Concession Stand 5.2 611410 Pedestrian Pavement, Sidewalk, Asphalt, Overlay 25 12 13 4780 SF $1.36 $6,486 $6,486 $6,486
Beecher Concession Stand 5.5 611404 Pole Light, Exterior, 135 to 1000 W HID (Fixture, Ballast, & Lamp), Replace 10 5 5 1 EA $2,246.90 $2,247 $2,247 $2,247 $4,494
Beecher Concession Stand 6.3 611361 Roof, Asphalt Shingle, Replace 20 12 8 895 SF $3.42 $3,061 $3,061 $3,061
Beecher Concession Stand 6.4 611349 Exterior Wall, Vinyl Siding, Replace 25 20 5 1090 SF $7.81 $8,512 $8,512 $8,512
Beecher Concession Stand 6.6 611553 Exterior Wall, Painted Surface, Prep & Paint 10 9 1 50 SF $2.87 $144 $144 $144 $287
Beecher Concession Stand 6.6 611469 Window, Vinyl-Clad Double-Glazed Slider, Replace 30 12 18 1 EA $813.20 $813 $813 $813
Beecher Concession Stand 6.6 611471 Window, Vinyl-Clad Double-Glazed Double Hung, Replace 30 12 18 1 EA $555.58 $556 $556 $556
Beecher Concession Stand 6.6 611356 Exterior Door, Steel, Replace 25 12 13 4 EA $950.12 $3,800 $3,800 $3,800
Beecher Concession Stand 7.1 611398 Condensing Unit/Heat Pump, Split System, 2 Ton, Replace 15 10 5 1 EA $3,122.18 $3,122 $3,122 $3,122
Beecher Concession Stand 7.1 611508 Furnace, Electric, 10 to 25 MBH, Replace 20 13 7 1 EA $3,136.39 $3,136 $3,136 $3,136
Beecher Concession Stand 7.2 611365 Toilet, Flush Tank (Water Closet), Replace 20 12 8 2 EA $1,055.15 $2,110 $2,110 $2,110
Beecher Concession Stand 7.2 611362 Lavatory, Vitreous China, Replace 20 12 8 3 EA $572.66 $1,718 $1,718 $1,718
Beecher Concession Stand 7.2 611502 Sink, Plastic, Replace 20 10 10 1 EA $575.99 $576 $576 $576
Beecher Concession Stand 7.2 611506 Water Heater, Electric, Residential, 19.9 GAL, Replace 15 12 3 1 EA $1,249.92 $1,250 $1,250 $1,250 $2,500
Beecher Concession Stand 7.4 611360 Metal Halide Lighting Fixture, Wall Mount, 100 W, Replace 20 12 8 2 EA $678.47 $1,357 $1,357 $1,357
Beecher Concession Stand 7.4 611498 Lighting System, Interior, Upgrade 25 10 15 745 SF $9.24 $6,885 $6,885 $6,885
Beecher Concession Stand 7.6 611511 Fire Extinguisher, Replace 15 4 11 1 EA $314.93 $315 $315 $315
Beecher Concession Stand 7.6 611444 Exit Lighting Fixture, , Replace 10 7 3 3 EA $405.01 $1,215 $1,215 $1,215 $2,430
Beecher Concession Stand 8.1 611475 Interior Door, Aluminum, Replace 30 12 18 1 EA $1,368.37 $1,368 $1,368 $1,368
Beecher Concession Stand 8.1 611367 Interior Wall Finish, Vinyl, Replace 15 10 5 1118 SF $2.27 $2,542 $2,542 $2,542
Beecher Concession Stand 8.1 611371 Interior Floor Finish, Vinyl Sheeting, Replace 15 10 5 745 SF $7.01 $5,222 $5,222 $5,222
Beecher Concession Stand 8.1 611310 Interior Ceiling Finish, Vinyl, Replace 20 12 8 145 SF $2.10 $304 $304 $304
Beecher Concession Stand 8.1 611316 Interior Ceiling Finish, Acoustical Tile (ACT), Replace 20 12 8 600 SF $3.11 $1,867 $1,867 $1,867
Beecher Concession Stand 8.1 611456 Residential Appliances, Refrigerator, 14-18 CF, Replace 15 10 5 1 EA $956.04 $956 $956 $956
Beecher Concession Stand 8.2 611460 Commercial Kitchen, Refrigerator, 2-Door Reach-In, Replace 15 10 5 1 EA $4,256.00 $4,256 $4,256 $4,256
Totals, Unescalated $565 $144 $0 $4,279 $0 $26,857 $0 $3,136 $12,231 $0 $576 $458 $0 $13,316 $0 $9,132 $0 $0 $5,801 $0 $76,496
Totals, Escalated (3.0% inflation, compounded annually)$565 $148 $0 $4,676 $0 $31,135 $0 $3,857 $15,494 $0 $774 $635 $0 $19,555 $0 $14,228 $0 $0 $9,876 $0 $100,943
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 908 Game Farm Road, Yorkville, Kendall, IL 60560
Year Constructed/Renovated: 2004
Current Occupants: Parks and Recreation
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Concession Stand
Site Area: 0.13 acres
Building Area: 745 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: Not applicable
Building Construction: Conventional wood frame structure on concrete slab
Roof Construction: Gabled roofs with asphalt shingles
Exterior Finishes: Vinyl Siding
Heating, Ventilation and Air Conditioning: Individual package split-system unit
Fire and Life/Safety: Smoke detectors, extinguishers, and exit signs.
Dates of Visit: May 22, 2017
On-Site Point of Contact (POC): Scott Sleezer
Assessment and Report Prepared by: Paul Prusa
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Good HVAC Fair
Structure Good Plumbing Fair
Roof Fair Electrical Fair
Vertical Envelope Fair Elevators --
Interiors Fair Fire --
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
2
www.EMGcorp.com p 800.733.0660
The following bullet points highlight the most significant short term and modernization recommendations:
Installation of a complete fire suppression system
ADA accessibility upgrades
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in good overall condition.
The property has had no major capital improvements. The property is less than 13 years old and has not required any major capital
improvements.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
3
www.EMGcorp.com p 800.733.0660
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 14.2% Poor
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 122% Very Poor
Current Replacement Value (CRV) 745 SF * 183.24 / SF = $45,809
Year 0 (Current Year) - Immediate Repairs (IR) $6,524
Years 1-10 – Replacement Reserves (RR) $56,084
Total Capital Needs $62,608
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Installation of a complete fire suppression system
ADA accessibility upgrades
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: ADA Checklist
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: RIGHT ELEVATION
#3: LEFT ELEVATION
#4: REAR ELEVATION
#5: PEDESTRIAN PAVEMENT,
SIDEWALK, ASPHALT
#6: PEDESTRIAN PAVEMENT,
SIDEWALK, CRACKING
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
www.EMGcorp.com p 800.733.0660
#7: POLE LIGHT, EXTERIOR
#8: ROOF, ASPHALT SHINGLE
#9: EXTERIOR WALL, VINYL SIDING
#10: DAMAGED VINYL SIDING
#11: WINDOW, VINYL-CLAD DOUBLE-
GLAZED DOUBLE HUNG
#12: EXTERIOR DOOR, STEEL
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
www.EMGcorp.com p 800.733.0660
#13: OVERHEAD DOOR, STEEL
SECURITY GATE
#14: WINDOW, VINYL-CLAD DOUBLE-
GLAZED SLIDER
#15: CONDENSING UNIT/HEAT PUMP,
SPLIT SYSTEM, 2 TON
#16: FURNACE, ELECTRIC
#17: SINK, POT, MULTI-
COMPARTMENT
#18: LAVATORY, VITREOUS CHINA
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
www.EMGcorp.com p 800.733.0660
#19: TOILET, FLUSH TANK (WATER
CLOSET)
#20: SINK, PLASTIC
#21: WATER HEATER, ELECTRIC
#22: METAL HALIDE LIGHTING
FIXTURE, WALL MOUNT
#23: LIGHTING SYSTEM, INTERIOR,
OFFICE BUILDING
#24: MAIN DISTRIBUTION PANEL
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
www.EMGcorp.com p 800.733.0660
#25: EXIT LIGHTING FIXTURE
#26: FIRE EXTINGUISHER
#27: INTERIOR DOOR, ALUMINUM
#28: INTERIOR DOOR BROKEN
HANDLE
#29: INTERIOR CEILING FINISH, VINYL
#30: INTERIOR WALL FINISH, VINYL
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
www.EMGcorp.com p 800.733.0660
#31: RESIDENTIAL APPLIANCES,
REFRIGERATOR
#32: INTERIOR FLOOR FINISH, VINYL
SHEETING
#33: INTERIOR CEILING FINISH,
ACOUSTICAL TILE (ACT)
#34:
COMMERCIAL KITCHEN,
REFRIGERATOR, 2-DOOR
REACH-IN
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Beecher Concession Stand
Project Number:
122700.17R000-007.366
Source:
Google Maps
On-Site Date:
May 22, 2017
BEECHER CONCESSION STAND EMG PROJECT NO.: 122700.17R000-007.366
www.EMGcorp.com p 800.733.0660
Appendix C:
ADA Checklist
Page 1 of 4
Date Completed: May 22, 2017
Property Name: Beecher Concession Stand
EMG Project Number: 122700.17R000-007.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Public Library
902 Game Farm Road
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-008.322 June 14, 2017 May 24, 2017
FACILITY CONDITION ASSESSMENT
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1. Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
1.3. Special Issues and Follow-Up Recommendations ...................................................................... 3
1.4. Opinions of Probable Cost .......................................................................................................... 3
1.4.1. Methodology ................................................................................................................................ 4
1.4.2. Immediate Repairs ...................................................................................................................... 4
1.4.3. Replacement Reserves ............................................................................................................... 4
2. Purpose and Scope .............................................................................................................................. 5
2.1. Purpose ....................................................................................................................................... 5
2.2. Scope .......................................................................................................................................... 6
2.3. Personnel Interviewed ................................................................................................................. 6
2.4. Documentation Reviewed ........................................................................................................... 7
2.5. Pre-Survey Questionnaire ........................................................................................................... 7
2.6. Weather Conditions ..................................................................................................................... 7
3. Accessibility and Property Research ................................................................................................. 8
3.1. ADA Accessibility ........................................................................................................................ 8
3.2. Municipal Information, Flood Zone and Seismic Zone ................................................................ 8
4. Existing Building Assessment ............................................................................................................ 9
4.1. Unit or Space Types .................................................................................................................... 9
4.2. Inaccessible Areas or Key Spaces Not Observed ...................................................................... 9
5. Site Improvements ............................................................................................................................. 10
5.1. Utilities ....................................................................................................................................... 10
5.2. Parking, Paving, and Sidewalks ................................................................................................ 10
5.3. Drainage Systems and Erosion Control .................................................................................... 11
5.4. Topography and Landscaping ................................................................................................... 12
5.5. General Site Improvements ....................................................................................................... 12
6. Building Architectural and Structural Systems ............................................................................... 14
6.1. Foundations ............................................................................................................................... 14
6.2. Superstructure ........................................................................................................................... 14
6.3. Roofing ...................................................................................................................................... 14
6.4. Exterior Walls ............................................................................................................................ 16
6.5. Exterior and Interior Stairs ......................................................................................................... 16
6.6. Exterior Windows and Doors ..................................................................................................... 16
6.7. Patio, Terrace, and Balcony ...................................................................................................... 17
7. Building Mechanical and Plumbing Systems .................................................................................. 18
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC) ..................................................... 18
7.2. Building Plumbing and Domestic Hot Water ............................................................................. 20
7.3. Building Gas Distribution ........................................................................................................... 21
7.4. Building Electrical ...................................................................................................................... 22
7.5. Building Elevators and Conveying Systems .............................................................................. 22
7.6. Fire Protection and Security Systems ....................................................................................... 23
7.7. Life Support Systems ................................................................................................................ 24
8. Interior Spaces .................................................................................................................................... 25
8.1. Interior Finishes ......................................................................................................................... 25
8.2. Commercial Kitchen & Laundry Equipment .............................................................................. 26
9. Other Structures ................................................................................................................................. 27
10. Certification ......................................................................................................................................... 28
11. Appendices ......................................................................................................................................... 29
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
1
www.EMGcorp.com p 800.733.0660
1. Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 902 Game Farm Road, Yorkville, Kendall, IL 60560
Year Constructed/Renovated: 1983
Current Occupants: City of Yorkville – Public Library
Percent Utilization: 100%
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Library
Site Area: 2.29 acres
Building Area: 40,000 SF
Number of Buildings: 1
Number of Stories: 2
Parking Type and Number of
Spaces: 59 spaces in open lots
Building Construction: Steel frame with concrete-topped metal decks
Roof Construction: Sloped roofs with metal finish
Flat roof with EPDM membrane
Exterior Finishes: Stone, brick veneer, siding.
Heating, Ventilation & Air
Conditioning:
Central system with boilers, chillers, and air handlers feeding VAV and
hydronic baseboard and ceiling radiators.
Supplemental components: computer room air conditioning unit, cabinet
unit heaters, and suspended unit heaters.
Fire and Life/Safety: Fire sprinklers, hydrants, smoke detectors, alarms, strobes,
extinguishers, pull stations, alarm panel, exit signs, and emergency
lighting.
Dates of Visit: May 24, 2017
On-Site Point of Contact (POC): Scott Sleezer
Assessment and Report
Prepared by: Paul Prusa
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6623
Systemic Condition Summary
Site Good HVAC Fair
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
2
www.EMGcorp.com p 800.733.0660
Systemic Condition Summary
Structure Good Plumbing Fair
Roof Good Electrical Good
Vertical Envelope Good Elevators Fair
Interiors Fair Fire Fair
The following bullet points highlight the most significant short term and modernization recommendations:
No significant short term of modernization recommendations were observed.
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in good overall condition.
The property has had no major capital improvements. The property is less than 10 years old and has not required any major capital
improvements.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
Fci Condition
Rating Definition Percentage
Value
Good In new or well-maintained condition, with no visual evidence
of wear, soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and
functioning condition. > than 5% to 10%
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
3
www.EMGcorp.com p 800.733.0660
Fci Condition
Rating Definition Percentage
Value
Poor Subjected to hard or long-term wear. Nearing the end of its
useful or serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal
is now necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.0% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 27.8% Poor
Current Replacement Value (CRV) 40,000 SF * 183.24 / SF = $7,329,485
Year 0 (Current Year) - Immediate Repairs (IR) $1,543
Years 1-10 – Replacement Reserves (RR) $2,042,965
Total Capital Needs $2,044,508
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
No significant immediate repair costs were observed.
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
1.3. Special Issues and Follow-Up Recommendations
As part of the FCA, a limited assessment of accessible areas of the building(s) was performed to determine the presence of fungal
growth, conditions conducive to fungal growth, and/or evidence of moisture. Property personnel were interviewed concerning any
known or suspected fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Sampling is not a part of this
assessment.
There are no visual indications of the presence of fungal growth, conditions conducive to fungal growth, or evidence of moisture in
representative readily accessible areas of the property.
1.4. Opinions of Probable Cost
Cost estimates are attached at the front of this report (following the cover page).
These estimates are based on Invoice or Bid Document/s provided either by the Owner/facility and construction costs developed by
construction resources such as R.S. Means and Marshall & Swift, EMG’s experience with past costs for similar properties, city cost
indexes, and assumptions regarding future economic conditions.
Opinions of probable costs should only be construed as preliminary, order of magnitude budgets. Actual costs most probably will vary
from the consultant’s opinions of probable costs depending on such matters as type and design of suggested remedy, quality of
materials and installation, manufacturer and type of equipment or system selected, field conditions, whether a physical deficiency is
repaired or replaced in whole, phasing of the work (if applicable), quality of contractor, quality of project management exercised, market
conditions, and whether competitive pricing is solicited, etc. ASTM E2018-08 recognizes that certain opinions of probable costs cannot
be developed within the scope of this guide without further study. Opinions of probable cost for further study should be included in the
FCA.
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
4
www.EMGcorp.com p 800.733.0660
1.4.1. Methodology
Based upon site observations, research, and judgment, along with referencing Expected Useful Life (EUL) tables from various industry
sources, EMG opines as to when a system or component will most probably necessitate replacement. Accurate historical replacement
records, if provided, are typically the best source of information. Exposure to the elements, initial quality and installation, extent of use,
the quality and amount of preventive maintenance exercised, etc., are all factors that impact the effective age of a system or
component. As a result, a system or component may have an effective age that is greater or less than its actual chronological age.
The Remaining Useful Life (RUL) of a component or system equals the EUL less its effective age. Projections of Remaining Useful Life
(RUL) are based on continued use of the Property similar to the reported past use. Significant changes in occupants and/or usage may
affect the service life of some systems or components.
Where quantities could not be derived from an actual take-off, lump sum costs or allowances are used. Estimated costs are based on
professional judgment and the probable or actual extent of the observed defect, inclusive of the cost to design, procure, construct and
manage the corrections.
1.4.2. Immediate Repairs
Immediate repairs are opinions of probable costs that require immediate action as a result of: (1) material existing or potential unsafe
conditions, (2) material building or fire code violations, or (3) conditions that, if not addressed, have the potential to result in, or
contribute to, critical element or system failure within one year or will most probably result in a significant escalation of its remedial cost.
1.4.3. Replacement Reserves
Replacement Reserves are for recurring probable expenditures, which are not classified as operation or maintenance expenses. The
replacement reserves should be budgeted for in advance on an annual basis. Replacement Reserves are reasonably predictable both
in terms of frequency and cost. However, Replacement Reserves may also include components or systems that have an
indeterminable life but, nonetheless, have a potential for failure within an estimated time period.
Replacement Reserves exclude systems or components that are estimated to expire after the reserve term and are not considered
material to the structural and mechanical integrity of the subject property. Furthermore, systems and components that are not deemed
to have a material effect on the use of the Property are also excluded. Costs that are caused by acts of God, accidents, or other
occurrences that are typically covered by insurance, rather than reserved for, are also excluded.
Replacement costs are solicited from ownership/property management, EMG’s discussions with service companies, manufacturers'
representatives, and previous experience in preparing such schedules for other similar facilities. Costs for work performed by the
ownership’s or property management’s maintenance staff are also considered.
EMG’s reserve methodology involves identification and quantification of those systems or components requiring capital reserve funds
within the assessment period. The assessment period is defined as the effective age plus the reserve term. Additional information
concerning system’s or component’s respective replacement costs (in today's dollars), typical expected useful lives, and remaining
useful lives were estimated so that a funding schedule could be prepared. The Replacement Reserves Schedule presupposes that all
required remedial work has been performed or that monies for remediation have been budgeted for items defined in the Immediate
Repair Cost Estimate.
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
5
www.EMGcorp.com p 800.733.0660
2. Purpose and Scope
2.1. Purpose
EMG was retained by the client to render an opinion as to the Property’s current general physical condition on the day of the site visit.
Based on the observations, interviews and document review outlined below, this report identifies significant deferred maintenance
issues, existing deficiencies, and material code violations of record at municipal offices, which affect the Property’s use. Opinions are
rendered as to its structural integrity, building system condition and the Property’s overall condition. The report also notes building
systems or components that have realized or exceeded their typical expected useful lives.
CONDITIONS:
The physical condition of building systems and related components are typically defined as being in one of five conditions: Excellent,
Good, Fair, Poor, Failed or a combination thereof. For the purposes of this report, the following definitions are used:
Excellent = New or very close to new; component or system typically has been installed within the past year, sound and
performing its function. Eventual repair or replacement will be required when the component or system either
reaches the end of its useful life or fails in service.
Good = Satisfactory as-is. Component or system is sound and performing its function, typically within the first third
of its lifecycle. However, it may show minor signs of normal wear and tear. Repair or replacement will be
required when the component or system either reaches the end of its useful life or fails in service.
Fair = Showing signs of wear and use but still satisfactory as-is, typically near the median of its estimated useful
life. Component or system is performing adequately at this time but may exhibit some signs of wear,
deferred maintenance, or evidence of previous repairs. Repair or replacement will be required due to the
component or system’s condition and/or its estimated remaining useful life.
Poor = Component or system is significantly aged, flawed, functioning intermittently or unreliably; displays obvious
signs of deferred maintenance; shows evidence of previous repair or workmanship not in compliance with
commonly accepted standards; has become obsolete; or exhibits an inherent deficiency. The present
condition could contribute to or cause the deterioration of contiguous elements or systems. Either full
component replacement is needed or repairs are required to restore to good condition, prevent premature
failure, and/or prolong useful life.
Failed
= Component or system has ceased functioning or performing as intended. Replacement, repair, or other
significant corrective action is recommended or required.
Not Applicable
= Assigning a condition does not apply or make logical sense, most commonly due to the item in question not
being present.
FORMAT OF THE BODY OF THE REPORT:
Throughout sections 5 through 9 of this report, each report section will typically contain three subsections organized in the following
sequence:
A descriptive table (and/or narrative), which identifies the components assessed, their condition, and other key data points.
A simple bulleted list of Anticipated Lifecycle Replacements, which lists components and assets typically in Excellent, Good, or Fair
condition at the time of the assessment but that will require replacement or some other attention once aged past their estimated
useful life. These listed components are typically included in the associated inventory database with costs identified and budgeted
beyond the first several years.
A bulleted cluster of Actions/Comments, which include more detailed narratives describing deficiencies, recommended repairs, and
short term replacements. The assets and components associated with these bullets are/were typically problematic and in Poor or
Failed condition at the time of the assessment, with corresponding costs included within the first few years.
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
6
www.EMGcorp.com p 800.733.0660
PLAN TYPES:
Each line item in the cost database is assigned a Plan Type, which is the primary reason or rationale for the recommended
replacement, repair, or other corrective action. This is the “why” part of the equation. A cost or line item may commonly have more
than one applicable Plan Type; however, only one Plan Type will be assigned based on the “best” fit, typically the one with the greatest
significance. The following Plan Types are listed in general weighted order of importance:
Safety = An observed or reported unsafe condition that if left unaddressed could result in an injury; a system or
component that presents a potential liability risk.
Performance/Integrity = Component or system has failed, is almost failing, performs unreliably, does not perform as intended,
and/or poses a risk to overall system stability.
Accessibility = Does not meet ADA, UFAS, and/or other handicap accessibility requirements.
Environmental = Improvements to air or water quality, including removal of hazardous materials from the building or
site.
Modernization/Adaptation
= Conditions, systems, or spaces that need to be upgraded in appearance or function to meet current
standards, facility usage, or client/occupant needs.
Lifecycle/Renewal
= Any component or system in which future repair or replacement is anticipated beyond the next several
years and/or is of minimal substantial early-term consequence.
2.2. Scope
The standard scope of the Facility Condition Assessment includes the following:
Visit the Property to evaluate the general condition of the building and site improvements, review available construction documents in
order to familiarize ourselves with, and be able to comment on, the in-place construction systems, life safety, mechanical, electrical,
and plumbing systems, and the general built environment.
Identify those components that are exhibiting deferred maintenance issues and provide cost estimates for Immediate Costs and
Replacement Reserves based on observed conditions, maintenance history and industry standard useful life estimates. This will
include the review of documented capital improvements completed within the last five-year period and work currently contracted for, if
applicable.
Provide a full description of the Property with descriptions of in-place systems and commentary on observed conditions.
Provide a general statement of the subject Property’s compliance to Title III of the Americans with Disabilities Act. This will not
constitute a full ADA survey, but will help identify exposure to issues and the need for further review.
Perform a limited assessment of accessible areas of the building(s) for the presence of fungal growth, conditions conducive to fungal
growth, and/or evidence of moisture. EMG will also interview Project personnel regarding the presence of any known or suspected
fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Potentially affected areas will be photographed.
Sampling will not be considered in routine assessments.
List the current utility service providers.
Review maintenance records and procedures with the in-place maintenance personnel.
Observe a representative sample of the interior spaces/units, including vacant spaces/units, in order to gain a clear understanding of
the property’s overall condition. Other areas to be observed include the exterior of the property, the roofs, interior common areas,
and the significant mechanical, electrical and elevator equipment rooms.
Provide recommendations for additional studies, if required, with related budgetary information.
Provide an Executive Summary at the beginning of this report.
Prepare a mechanical equipment inventory list.
2.3. Personnel Interviewed
The building engineer were interviewed for specific information relating to the physical property, available maintenance procedures,
historical performance of key building systems and components, available drawings and other documentation. The following personnel
from the facility and government agencies were interviewed in the process of conducting the FCA:
Name and Title Organization Phone Number
Scott Sleezer City of Yorkville – Parks and Recreation 630.878.7291
The FCA was performed without the assistance of an onsite Point of Contact (POC).
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
7
www.EMGcorp.com p 800.733.0660
2.4. Documentation Reviewed
Prior to the FCA, relevant documentation was requested that could aid in the knowledge of the subject property’s physical
improvements, extent and type of use, and/or assist in identifying material discrepancies between reported information and observed
conditions. The review of submitted documents does not include comment on the accuracy of such documents or their preparation,
methodology, or protocol. The Documentation Request Form is provided in Appendix E.
Although Appendix E provides a summary of the documents requested or obtained, the following list provides more specific details
about some of the documents that were reviewed or obtained during the site visit.
No documents were provided.
2.5. Pre-Survey Questionnaire
A Pre-Survey Questionnaire was sent to the POC prior to the site visit and was not returned. The questionnaire is included in Appendix
E.
2.6. Weather Conditions
May 24, 2017: Cloudy, with temperatures in the 80s (°F) and light winds.
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
8
www.EMGcorp.com p 800.733.0660
3. Accessibility and Property Research
3.1. ADA Accessibility
Generally, Title III of the Americans with Disabilities Act (ADA) prohibits discrimination by entities to access and use of “areas of public
accommodations” and “commercial facilities” on the basis of disability. Regardless of its age, these areas and facilities must be
maintained and operated to comply with the Americans with Disabilities Act Accessibility Guidelines (ADAAG).
Buildings completed and occupied after January 26, 1992 are required to comply fully with the ADAAG. Existing facilities constructed
prior to this date are held to the lesser standard of compliance to the extent allowed by structural feasibility and the financial resources
available. As an alternative, a reasonable accommodation pertaining to the deficiency must be made.
During the FCA, a limited visual observation for ADA accessibility compliance was conducted. The scope of the visual observation was
limited to those areas set forth in EMG’s Abbreviated Accessibility Checklist provided in Appendix D of this report. It is understood by
the Client that the limited observations described herein does not comprise a full ADA Compliance Survey, and that such a survey is
beyond the scope of EMG’s undertaking. Only a representative sample of areas was observed and, other than as shown on the
Abbreviated Accessibility Checklist, actual measurements were not taken to verify compliance.
At a office property, the areas considered as a public accommodation besides the site itself and parking, are the exterior accessible
route, the interior accessible route up to the tenant lease lines and the interior common areas, including the common area restrooms.
The facility does not appear to be accessible with Title III of the Americans with Disabilities Act. Elements as defined by the ADAAG
that are not accessible as stated within the priorities of Title III, are as follows:
Parking
Adequate number of designated parking stalls and signage for vans are not provided.
Restrooms
Wrap drain pipes below lavatory with insulation; protect against contact with hot, sharp, or abrasive surfaces. Original library area
only.
A full ADA Compliance Survey may reveal additional aspects of the property that are not in compliance.
Corrections of these conditions should be addressed from a liability standpoint, but are not necessarily code violations. The Americans
with Disabilities Act Accessibility Guidelines concern civil rights issues as they pertain to the disabled and are not a construction code,
although many local jurisdictions have adopted the Guidelines as such. The cost to address the achievable items noted above is
included in the cost tables.
3.2. Municipal Information, Flood Zone and Seismic Zone
Not applicable.
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
9
www.EMGcorp.com p 800.733.0660
4. Existing Building Assessment
4.1. Unit or Space Types
All 40,000 square feet of the building are occupied by a single occupant, City of Yorkville Public Library. The spaces are a combination
of offices, reading rooms, library, meeting rooms, supporting restrooms, mechanical, and other utility spaces.
4.2. Inaccessible Areas or Key Spaces Not Observed
The interior spaces were observed in order to gain a clear understanding of the property’s overall condition. Other areas accessed
included the site within the property boundaries, exterior of the property and the roof. All areas of the property were available for
observation during the site visit.
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
10
www.EMGcorp.com p 800.733.0660
5. Site Improvements
5.1. Utilities
The following table identifies the utility suppliers and the condition and adequacy of the services.
Site Utilities
Utility Supplier Condition and Adequacy
Sanitary sewer City of Yorkville Good
Storm sewer City of Yorkville Good
Domestic water City of Yorkville Good
Electric service Commonwealth Edison Good
Natural gas service Nicor Gas Good
Actions/Comments:
According to the POC, the utilities provided are adequate for the property. There are no unique, onsite utility systems such as
emergency electrical generators, septic systems, water or waste water treatment plants, or propane gas tanks.
5.2. Parking, Paving, and Sidewalks
Item Description
Main Ingress and Egress Game Farm Road
Access from West
Additional Entrances --
Additional Access from --
Paving and Flatwork
Item Material Last Work Done Condition
Entrance Driveway Apron Asphalt 2006 Fair
Parking Lot Asphalt 2006 Fair
Drive Aisles Asphalt 2006 Fair
Service Aisles None -- --
Sidewalks Concrete 2006 Good
Curbs Concrete 2006 Good
Site Stairs Cast-in-place concrete 2006 Good
Pedestrian Ramps None -- --
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
11
www.EMGcorp.com p 800.733.0660
Parking Count
Open Lot Carport Private Garage Subterranean
Garage
Freestanding Parking
Structure
59 0 0 0 0
Total Number of ADA Compliant Spaces 6
Number of ADA Compliant Spaces for Vans 0
Total Parking Spaces 59
Parking Ratio (Spaces/Apartments) --
Method of Obtaining Parking Count Physical count
Exterior Stairs
Location Material Handrails Condition
Right side of building Concrete stairs Metal Good
Anticipated Lifecycle Replacements:
Asphalt seal coating
Asphalt pavement
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
5.3. Drainage Systems and Erosion Control
Drainage System and Erosion Control
System Exists At Site Condition
Surface Flow ☐ --
Inlets ☒ Good
Swales ☐ --
Detention pond ☐ --
Lagoons ☐ --
Ponds ☐ --
Underground Piping ☒ Good
Pits ☐ --
Municipal System ☒ Good
Dry Well ☐ --
Anticipated Lifecycle Replacements:
No components of significance
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
12
www.EMGcorp.com p 800.733.0660
Actions/Comments:
There is no evidence of storm water runoff from adjacent properties. The storm water system appears to provide adequate runoff
capacity. There is no evidence of major ponding or erosion.
5.4. Topography and Landscaping
Item Description
Site Topography Generally flat
Landscaping Trees Grass Flower
Beds Planters
Drought
Tolerant
Plants
Decorative
Stone None
☒ ☒ ☐ ☐ ☒ ☒ ☐
Landscaping
Condition Good
Irrigation
Automatic
Underground Drip Hand Watering None
☐ ☐ ☐ ☒
Irrigation Condition --
Retaining Walls
Type Location Condition
Concrete East end of site separating parking lot of adjacent
building Good
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The topography and adjacent uses do not appear to present conditions detrimental to the property. There are no significant areas of
erosion.
5.5. General Site Improvements
Property Signage
Property Signage Monument
Street Address Displayed? Yes
Site and Building Lighting
Site Lighting
None Pole Mounted Bollard Lights Ground
Mounted
Parking Lot
Pole Type
☐ ☒ ☒ ☐ ☒
Fair
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
13
www.EMGcorp.com p 800.733.0660
Site and Building Lighting
Building Lighting
None Wall Mounted Recessed Soffit
☐ ☒ ☒
Fair
Site Fencing
Type Location Condition
Wrought iron Multiple locations Good
REFUSE DISPOSAL
Refuse Disposal Common area dumpsters
Dumpster Locations Mounting Enclosure Contracted? Condition
East side of property Concrete
pad Wood board fence Yes Good
Other Site Amenities
Description Location Condition
Playground Equipment None -- --
Tennis Courts None -- --
Basketball Court None -- --
Swimming Pool None -- --
Anticipated Lifecycle Replacements:
Exterior lighting
Site fencing
Benches
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
14
www.EMGcorp.com p 800.733.0660
6. Building Architectural and Structural Systems
6.1. Foundations
Building Foundation
Item Description Condition
Foundation Concrete spread footings Good
Basement and Crawl Space None --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The foundation systems are concealed. There are no significant signs of settlement, deflection, or movement.
6.2. Superstructure
Building Superstructure
Item Description Condition
Framing / Load-Bearing Walls Steel columns and beams Good
Ground Floor Concrete slab Good
Upper Floor Framing Steel beams Good
Upper Floor Decking Metal decking with concrete topping Good
Roof Framing Steel beams or girders Good
Roof Decking Metal decking Good
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The superstructure is exposed in some locations, which allows for limited observation. Walls and floors appear to be plumb, level,
and stable. There are no significant signs of deflection or movement.
6.3. Roofing
Primary Roof
Type / Geometry Sloped Finish Metal
Maintenance Outside Contractor Roof Age 10 Years
Flashing Sheet metal Warranties Yes
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
15
www.EMGcorp.com p 800.733.0660
Primary Roof
Parapet Copings None Roof Drains Gutters and downspouts
Fascia Metal Panel Insulation Rigid Board
Soffits Concealed Soffits Skylights No
Attics None Ponding No
Ventilation Source-1 Turtle Vents Leaks Observed No
Ventilation Source-2 Soffit Vents Roof Condition Good
The primary roof is located throughout the majority of the building.
Secondary Roof
Type / Geometry Flat Finish EPDM Membrane
Maintenance Outside Contractor Roof Age 10 Years
Flashing Built-up base and Edge flashing Warranties Yes
Parapet Copings Pre-cast Concrete and Sheet
Metal Roof Drains Internal drains
Fascia None Insulation Rigid Board
Soffits None Skylights No
Attics None Ponding Yes
Ventilation Source-1 Parapet and Wall Vent Leaks Observed No
Ventilation Source-2 -- Roof Condition Fair
The secondary roof is located at the center portion of the building, second story.
Anticipated Lifecycle Replacements:
EPDM roof membrane
Roof flashings (included as part of overall membrane replacement)
Parapet wall copings (included as part of overall membrane replacement)
Actions/Comments:
The roof finishes were reportedly installed in 2006. Information regarding roof warranties or bonds was not available but given the
age it is assumed a warranty is still active. The roofs are maintained by an outside contractor.
According to the POC, there are no active roof leaks. There is no evidence of active roof leaks.
There is no evidence of roof deck or insulation deterioration. The roof substrate and insulation should be inspected during any future
roof repair or replacement work.
Roof drainage appears to be adequate. However, debris build-up has caused ponding issues around the flat roof drains. Clearing
and minor repair of drain system components should be performed regularly as part of the property management’s routine
maintenance and operations program.
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
16
www.EMGcorp.com p 800.733.0660
6.4. Exterior Walls
Building Exterior Walls
Type Location Condition
Primary Finish Cement board siding Good
Secondary Finish Brick veneer Good
Accented with Stone veneer Good
Soffits Concealed Good
Building sealants (caulking) are located between dissimilar materials, at joints, and around window and door openings.
Anticipated Lifecycle Replacements:
Exterior painting
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance, including patching repairs, graffiti removal,
and re-caulking, is highly recommended. Future lifecycle replacements of the components listed above will be required.
6.5. Exterior and Interior Stairs
Building Exterior and Interior Stairs
Type Description Riser Handrail Balusters Condition
Building Exterior Stairs Concrete stairs Closed Metal Metal Good
Building Interior Stairs Steel framed with pan-filled
concrete Closed Metal Metal Good
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
6.6. Exterior Windows and Doors
Building Windows
Window Framing Glazing Location Window
Screen Condition
Curtain wall Double glaze Exterior walls ☐ Good
Aluminum framed storefront Double glaze Front elevation ☐ Good
Aluminum framed, fixed Double glaze Exterior walls ☐ Good
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
17
www.EMGcorp.com p 800.733.0660
Building Doors
Main Entrance Doors Door Type Condition
Fully glazed, metal framed Good
Secondary Entrance Doors Fully glazed, metal framed Good
Service Doors Metal, insulated Fair
Overhead Doors None --
Anticipated Lifecycle Replacements:
Windows
Curtain wall glazing
Storefront glazing
Exterior doors
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
6.7. Patio, Terrace, and Balcony
Not applicable. There are no patios, terraces, or balconies.
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
18
www.EMGcorp.com p 800.733.0660
7. Building Mechanical and Plumbing Systems
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC)
Individual Units (Original Library 1983)
Primary Components Split system furnaces and condensing units
Cooling (if separate from above) performed via components above
Quantity and Capacity Ranges 2 units at 5 tons each
Total Heating or Cooling Capacity 10 tons
Heating Fuel Natural gas
Location of Equipment Utility closets
Space Served by System Original library wing (1983)
Age Ranges Vary from 2002 to 2010
Primary Component Condition Fair
Building Central Heating System
Primary Heating System Type Hot water boilers
Quantity and Capacity of Major Components 2 boilers at 1,999 MBH each
Total Heating Capacity 3,998 MBH
Heating Fuel Natural gas
Location of Major Equipment Mechanical rooms
Space Served by System Newer wing
Age Ranges All units dated 2006
Boiler Condition Fair
Heat Exchanger Condition --
Building Central Cooling System
Primary Cooling System Type Air-cooled chillers
Quantity and Capacity of Major Components 1 chillers at 170 tons
Total Cooling Capacity 170 tons
Refrigerant R-134A
Cooling Towers None
Location of Major Equipment Building exterior
Space Served by System Newer wing
Age Ranges Unit dated 2006
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
19
www.EMGcorp.com p 800.733.0660
Building Central Cooling System
Chiller Condition Fair
Cooling Tower Condition --
Distribution System
HVAC Water Distribution System Four-pipe
Heating Water Circulation Pump Size & Quantity 2 pumps at 5.0 HP each – primary pumps
2 pumps at 7.5 HP each – secondary pumps
Chilled Water Circulation Pump Size & Quantity 1 pump at 15 HP
Condenser Water Circulation Pump Size & Quantity --
Pump Condition Fair
Air Distribution System Variable volume
Quantity and Capacity of Air Handlers 1 air handler at 32,025 CFM
Location of Air Handlers Mechanical rooms
Large Spaces the Larger Dedicated AHU’s Serve --
Age of Air Handlers Unit dated 2006
Air Handler Condition Fair
Terminal Units VAV boxes
Quantity and Capacity of Terminal Units Approximately 32 VAV boxes assumed to an average size of
1,000 cfm.
Location of Terminal Units Above ceilings
Spaces Served by Terminal Units Throughout facility
Terminal Unit Condition Fair
Supplemental Components
Supplemental Component #1 Dedicated computer room air conditioners
Location / Space Served by Computer Room Air
Conditioners Telecom
Computer Room Air Conditioners Condition Fair
Supplemental Component #2 Radiant ceiling panel
Location / Space Served by Radiant Ceiling Panel Building Perimeter
Radiant Ceiling Panel Condition Fair
Supplemental Component #3 Suspended and cabinet unit heaters
Location / Space Served by Unit Heater Mechanical rooms and stairwells
Unit Heater Condition Fair
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
20
www.EMGcorp.com p 800.733.0660
Controls and Ventilation
HVAC Control System BAS, direct digital controls (DDC)
HVAC Control System Condition Fair
Building Ventilation Roof top exhaust fans
Ventilation System Condition Fair
Anticipated Lifecycle Replacements:
Boilers
Chillers
Air handling unit
Distribution pumps and motors
VAV boxes
Split system furnaces and condensing units
Electric wall heaters
Suspended hydronic unit heaters
Cabinet unit heaters
Baseboard heaters
Radiant ceiling panels
Rooftop exhaust fans
Humidifier
Actions/Comments:
The HVAC systems are maintained by the in-house maintenance staff. Records of the installation, maintenance, upgrades, and
replacement of the HVAC equipment at the property have been maintained since the property was first occupied.
The HVAC equipment appears to vary in age with approximately 90% of the equipment being installed with the 2006 addition. The
property is relatively new and has not required any major HVAC equipment replacements.
The HVAC equipment appears to be functioning adequately overall. The building occupants were interviewed about the historical
and recent performance of the equipment and systems. No chronic problems were reported and an overall sense of satisfaction with
the systems was conveyed. However, due to the inevitable failure of parts and components over time, some of the equipment will
require replacement. A budgetary cost for this work is included.
7.2. Building Plumbing and Domestic Hot Water
Building Plumbing System
Type Description Condition
Water Supply Piping Copper Good
Waste/Sewer Piping Cast iron Good
Vent Piping Cast iron Good
Water Meter Location Mechanical room
Domestic Water Heaters or Boilers
Components Water Heaters
Fuel Natural gas
Quantity and Input Capacity 1 unit at 125,000 BTUH
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
21
www.EMGcorp.com p 800.733.0660
Domestic Water Heaters or Boilers
Storage Capacity 60 gallons
Boiler or Water Heater Condition Fair
Supplementary Storage Tanks? No
Storage Tank Quantity & Volume --
Quantity of Storage Tanks --
Storage Tank Condition --
Domestic Hot Water Circulation Pumps (3 HP and over) No
Adequacy of Hot Water Adequate
Adequacy of Water Pressure Adequate
Plumbing Fixtures
Water Closets Commercial
Toilet (Water Closet) Flush Rating 1.6 GPF
Common Area Faucet Nominal Flow Rate 2.0 GPM
Condition Fair
Anticipated Lifecycle Replacements:
Water heater
Toilets
Urinals
Sinks
lavatories
Actions/Comments:
The plumbing systems appear to be well maintained and functioning adequately. The water pressure appears to be sufficient. No
significant repair actions or short term replacement costs are required. Routine and periodic maintenance is recommended. Future
lifecycle replacements of the components or systems listed above will be required.
7.3. Building Gas Distribution
Gas service is supplied from the gas main on the adjacent public street. The gas meter and regulator are located along the exterior
walls of the building. The gas distribution piping within the building is malleable steel (black iron).
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The pressure and quantity of gas appear to be adequate.
The gas meter and regulator appear to be functioning adequately and will require routine maintenance.
Only limited observation of the gas distribution piping can be made due to hidden conditions.
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
22
www.EMGcorp.com p 800.733.0660
7.4. Building Electrical
Building Electrical Systems
Electrical Lines Underground Transformer Pad-mounted
Main Service Size 1,200 Amps Volts 277/480 Volt, three-phase
Meter & Panel Location Electrical Room Branch Wiring Copper
Conduit Metallic Step-Down
Transformers? Yes
Security / Surveillance
System? Yes Building Intercom
System? No
Lighting Fixtures T-8
Main Distribution Condition Good
Secondary Panel and
Transformer Condition Good
Lighting Condition Fair
Anticipated Lifecycle Replacements:
Circuit breaker panels
Main switchboard
Step-down transformer
Interior light fixtures
Actions/Comments:
The onsite electrical systems up to the meters are owned and maintained by the respective utility company.
The electrical service and capacity appear to be adequate for the property’s demands.
The panels, switchboard, step-down transformer are mostly original 2006 components, however, the original library has 1983
components. The electrical service is reportedly adequate for the facility’s needs. However, due to the age of the panels,
switchboard, and step-down transformers and increasing difficulty of obtaining replacement parts over time, lifecycle replacements
are recommended per above.
7.5. Building Elevators and Conveying Systems
Building Elevators
Manufacturer ThyssenKrupp Machinery Location Ground floor or basement
adjacent to shaft
Safety Stops Electronic Emergency Equipment Yes
Cab Floor Finish Carpet Cab Wall Finish Plastic-laminated wood
Hydraulic Elevators 1 car at 2,500 LB
Overhead Traction Elevators None
Freight Elevators None
Machinery Condition Good
Controls Condition Fair
Cab Finish Condition Fair
Other Conveyances None
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
23
www.EMGcorp.com p 800.733.0660
Building Elevators
Other Conveyance Condition --
Anticipated Lifecycle Replacements:
Elevator controls
Hydraulic machinery
Elevator cab finishes
Actions/Comments:
The elevators appear to provide adequate service. The elevators are serviced by an outside contractor on a routine basis. The
elevator machinery and controls are the originally installed system. The elevators will require continued periodic maintenance.
The elevators are inspected on an annual basis by the municipality, and a certificate of inspection is displayed in each elevator cab.
The emergency communication equipment in the elevator cabs appears to be functional. Equipment testing is not within the scope of
the work.
The finishes in the elevator cabs will require replacement. The cost to replace the finishes is relatively insignificant and the work can
be performed as part of the property management’s operations program.
7.6. Fire Protection and Security Systems
Item Description
Type Wet pipe
Fire Alarm System
Central Alarm Panel ☒ Battery-Operated Smoke
Detectors ☐ Alarm Horns ☒
Annunciator Panels ☒ Hard-Wired Smoke
Detectors ☒ Strobe Light Alarms ☒
Pull Stations ☒ Emergency Battery-Pack
Lighting ☒ Illuminated EXIT Signs ☒
Alarm System
Condition Fair
Sprinkler System
None ☐ Standpipes ☒ Backflow Preventer ☒
Hose Cabinets ☐ Fire Pumps ☐ Siamese Connections ☐
Suppression
Condition Fair
Central Alarm Panel
System
Location of Alarm Panel Installation Date of Alarm Panel
Entry vestibule 2006
Fire Extinguishers
Last Service Date Servicing Current?
April 2017 Yes
Hydrant Location Front elevation
Siamese Location --
Special Systems Kitchen Suppression System ☐Computer Room Suppression System ☐
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
24
www.EMGcorp.com p 800.733.0660
Anticipated Lifecycle Replacements:
Central alarm panel
Alarm devices and system
Sprinkler heads
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
7.7. Life Support Systems
Not applicable.
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
25
www.EMGcorp.com p 800.733.0660
8. Interior Spaces
8.1. Interior Finishes
The facility is used as a library for the City of Yorkville.
The most significant interior spaces include library, offices, meeting room, and main entrance lobby. Supporting areas include
hallways, stairs, restrooms, employee break rooms, mechanical rooms, utility closets, back-of-house areas.
The following table generally describes the locations and typical conditions of the interior finishes within the facility:
Typical Floor Finishes
Floor Finish Locations General Condition
Carpet Library, offices, meeting rooms, breakroom Fair
Vinyl tile Utility closets Fair
Ceramic tile Lobby, restrooms Good
Wood strip Lounge, breakroom Good
Unfinished Mechanical rooms Good
Typical Wall Finishes
Wall Finish Locations General Condition
Painted drywall Throughout building Fair
Ceramic tile Restrooms Good
Wallpaper Lobby Fair
Typical Ceiling Finishes
Ceiling Finish Locations General Condition
Suspended T-bar (Acoustic) Offices, library, lounges Fair
Painted drywall Meeting room, library, restrooms, lobby Fair
Exposed structure Library, mechanical rooms Good
Interior Doors
Item Type Condition
Interior Doors Solid core wood Fair
Door Framing Metal Fair
Fire Doors Yes Fair
Anticipated Lifecycle Replacements:
Carpet
Vinyl tile
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
26
www.EMGcorp.com p 800.733.0660
Ceramic tile
Wood strip flooring
Interior paint
Wallpaper
Suspended acoustic ceiling tile
Interior doors
Kitchenette appliances
Actions/Comments:
The interior areas were last renovated in 2006.
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
8.2. Commercial Kitchen & Laundry Equipment
Not applicable.
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
27
www.EMGcorp.com p 800.733.0660
9. Other Structures
Not applicable. There are no major accessory structures.
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
28
www.EMGcorp.com p 800.733.0660
10. Certification
City of Yorkville retained EMG to perform this Facility Condition Assessment in connection with its continued operation of Public Library,
902 Game Farm Road, Yorkville, Illinois, the “Property”. It is our understanding that the primary interest of City of Yorkville is to locate
and evaluate materials and building system defects that might significantly affect the value of the property and to determine if the
present Property has conditions that will have a significant impact on its continued operations.
The conclusions and recommendations presented in this report are based on the brief review of the plans and records made available
to our Project Manager during the site visit, interviews of available property management personnel and maintenance contractors
familiar with the Property, appropriate inquiry of municipal authorities, our Project Manager’s walk-through observations during the site
visit, and our experience with similar properties.
No testing, exploratory probing, dismantling or operating of equipment or in depth studies were performed unless specifically required
under Section 2 of this report. This assessment did not include engineering calculations to determine the adequacy of the Property’s
original design or existing systems. Although walk-through observations were performed, not all areas were observed (See Section 4.2
for areas observed). There may be defects in the Property, which were in areas not observed or readily accessible, may not have been
visible, or were not disclosed by management personnel when questioned. The report describes property conditions at the time that
the observations and research were conducted.
This report has been prepared on behalf of and exclusively for the use of City of Yorkville for the purpose stated within Section 2 of this
report. The report, or any excerpt thereof, shall not be used by any party other than City of Yorkville or for any other purpose than that
specifically stated in our agreement or within Section 2 of this report without the express written consent of EMG.
Any reuse or distribution of this report without such consent shall be at City of Yorkville and the recipient’s sole risk, without liability to
EMG.
Prepared by: Paul Prusa P.E., LEED AP,
Project Manager
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6623
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
29
www.EMGcorp.com p 800.733.0660
11. Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: EMG Accessibility Checklist
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: REAR ELEVATION
#3: RIGHT ELEVATION
#4: LEFT ELEVATION
#5: ADA, RESTROOM, LAVATORY
PIPE WRAPS
#6: SIDEWALK
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#7: PARKING LOTS, ASPHALT
PAVEMENT
#8: PARKING LOTS, MINOR
CRACKING
#9: BUILDING SIGNAGE
#10: WALKWAY BOLLARD LIGHTING
#11: POLE LIGHT, EXTERIOR,
DECORATIVE
#12: POLE LIGHT, EXTERIOR,
DOUBLE FIXTURE
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#13: POLE LIGHT, EXTERIOR,
SINGLE FIXTURE
#14: FENCES & GATES, WROUGHT
IRON
#15: BENCH
#16: ROOF, METAL
#17: ROOF, SINGLE-PLY EPDM
MEMBRANE
#18: PONDING AT DRAINS
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#19: EXTERIOR WALL, PAINTED
SURFACE
#20:
EXTERIOR DOOR, FULLY-
GLAZED ALUMINUM-FRAMED
SWINGING
#21:
EXTERIOR DOOR, FULLY-
GLAZED ALUMINUM-FRAMED
SWINGING MOTOR-OPERATED
#22: EXTERIOR DOOR, STEEL
#23: STOREFRONT, METAL-FRAMED
WINDOWS
#24: CURTAIN WALL, ALUMINUM-
FRAMED SYSTEM W/ GLAZING
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#25: WINDOW, ALUMINUM DOUBLE-
GLAZED
#26: WINDOW, ALUMINUM DOUBLE-
GLAZED
#27: AIR HANDLER
#28: RADIANT CEILING PANELS
#29: CONDENSING UNIT/HEAT
PUMP
#30: CHILLER
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#31: AIR HANDLER
#32: CABINET HEATER
#33: CIRCULATION PUMP, CHILLER
WATER
#34: CIRCULATION PUMP, HEATING
WATER, PRIMARY
#35: CIRCULATION PUMP, HEATING
WATER, SECONDARY
#36: HUMIDIFIER, STEAM, DUCT W/
CONTROLS
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#37: BUILDING AUTOMATION
SYSTEM (HVAC CONTROLS)
#38: INTERIOR STAIRS
#39: BOILER
#40: AIR CONDITIONER, COMPUTER
ROOM
#41: VARIABLE AIR VOLUME (VAV)
UNIT
#42: GLYCOL FEED SYSTEM
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#43: RADIATOR, HYDRONIC
BASEBOARD
#44: EXHAUST FAN, ROOF
MOUNTED
#45: DRINKING FOUNTAIN,
REFRIGERATED
#46: BACKFLOW PREVENTER, 2"
#47: WATER HEATER, CONDENSING
STYLE, HIGH EFFICIENCY
#48: SERVICE SINK
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#49: LAVATORY
#50: WATER SOFTENER
#51: TOILET, TANKLESS
#52: DRINKING FOUNTAIN,
REFRIGERATED
#53: LAVATORY
#54: URINAL
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#55: SINK, STAINLESS STEEL
#56: BACKFLOW PREVENTER, 3"
#57: VARIABLE FREQUENCY DRIVE
(VFD)
#58: SECONDARY TRANSFORMER,
DRY
#59: LIGHTING SYSTEM
#60: METAL HALIDE LIGHTING
FIXTURE, WALL MOUNT
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#61: MAIN DISTRIBUTION PANEL
#62: SWITCHBOARD, 1,000 AMP
#63: ELEVATOR, HYDRAULIC
#64: ELEVATOR, MACHINERY
#65: CAMERA, SECURITY SYSTEM
#66: EXIT LIGHTING FIXTURE, LED
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#67: BACKFLOW PREVENTER, 4"
#68: FIRE ALARM CONTROL PANEL,
ADDRESSABLE
#69: FIRE EXTINGUISHER
#70: INTERIOR DOOR
#71: RESIDENTIAL APPLIANCES,
REFRIGERATOR
#72: INTERIOR WALL FINISH,
CERAMIC TILE
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#73: INTERIOR WALL FINISH,
WALLPAPER
#74: TOILET PARTITIONS
#75: INTERIOR FLOOR FINISH,
VINYL TILE (VCT)
#76: INTERIOR WINDOW
#77: INTERIOR FLOOR FINISH,
CERAMIC TILE
#78: INTERIOR FLOOR FINISH,
CARPET
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#79: INTERIOR DOOR, BI-FOLD
#80: INTERIOR WALL FINISH,
GYPSUM BOARD
#81: INTERIOR FLOOR FINISH,
WOOD STRIP
#82: INTERIOR CEILING FINISH,
GYPSUM BOARD
#83: INTERIOR WALL FINISH, WOOD
PANELING
#84: INTERIOR CEILING FINISH,
ACOUSTICAL TILE (ACT)
PUBLIC LIBRARY
902 GAME FARM ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
#85: INTERIOR DOOR, FIRE 90-
MINUTES AND OVER
#86: INTERIOR DOOR, FULLY-
GLAZED WOOD-FRAMED
#87: KITCHEN CABINET, BASE AND
WALL SECTION, WOOD
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Public Library
Project Number:
122700.17R000-008.322
Source:
Google Maps
On-Site Date:
May 24, 2017
PUBLIC LIBRARY EMG PROJECT NO.: 122700.17R000-008.322
www.EMGcorp.com p 800.733.0660
Appendix C:
EMG Accessibility Checklist
Page 1 of 4
Date Completed: June 14, 2017
Property Name: Public Library
EMG Project Number: 122700.17R000-008.322
Building History Yes No Unk Comments
1 Has an ADA survey previously been
completed for this property? X
2 Have any ADA improvements been made
to the property? X
3 Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4 Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5 Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1 Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2 Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5 Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6 If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X Missing in 1983 wing of building but installed
in main building.
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards. X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Non- Kiwanis Park Shelter
1809 Country Hills Drive
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-009.366 June 10, 2017 May 22, 2017
FACILITY CONDITION ASSESSMENT
NON- KIWANIS PARK SHELTER EMG PROJECT NO.: 122700.17R000-009.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
NON- KIWANIS PARK SHELTER EMG PROJECT NO.: 122700.17R000-009.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 1809 Country Hills Drive, Yorkville, Kendall, IL 60560
Year Constructed/Renovated: 2004
Current Occupants: Parks and Recreation
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Park
Site Area: 2.2 acres
Building Area: 155 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: Not applicable
Building Construction: Steel frame on concrete deck
Roof Construction: Pyramid roof with metal finish
Exterior Finishes: Not applicable
Heating, Ventilation and Air Conditioning: Not applicable
Fire and Life/Safety: Not applicable
Dates of Visit: May 22, 2017
On-Site Point of Contact (POC): Scott Sleezer
Assessment and Report Prepared by: Paul Prusa
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Good HVAC --
Structure Good Plumbing --
Roof Good Electrical --
Vertical Envelope -- Elevators --
Interiors -- Fire --
NON- KIWANIS PARK SHELTER EMG PROJECT NO.: 122700.17R000-009.366
2
www.EMGcorp.com p 800.733.0660
The following bullet points highlight the most significant short term and modernization recommendations:
Seal coating asphalt sidewalk
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in good overall condition.
According to property management personnel, the property has had an active capital improvement expenditure program over the past
three years, primarily consisting of painting, asphalt pavement seal coating, and play surface maintenance. Supporting documentation
was not provided in support of these claims but some of the work is evident.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
NON- KIWANIS PARK SHELTER EMG PROJECT NO.: 122700.17R000-009.366
3
www.EMGcorp.com p 800.733.0660
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.0% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 40.4% Poor
Current Replacement Value (CRV) 155 SF * 183.24 / SF = $91,619
Year 0 (Current Year) - Immediate Repairs (IR) $31
Years 1-10 – Replacement Reserves (RR) $37,070
Total Capital Needs $37,101
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Metal roof repair
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
NON- KIWANIS PARK SHELTER EMG PROJECT NO.: 122700.17R000-009.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: ADA Checklist
NON- KIWANIS PARK SHELTER EMG PROJECT NO.: 122700.17R000-009.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
NON- KIWANIS PARK SHELTER EMG PROJECT NO.: 122700.17R000-009.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: REAR ELEVATION
#3: PEDESTRIAN PAVEMENT,
SIDEWALK, ASPHALT
#4: SIDEWALK, MINOR CRACKING
#5: OVERALL SITE
#6: BASKETBALL COURT - OVERALL
NON- KIWANIS PARK SHELTER EMG PROJECT NO.: 122700.17R000-009.366
www.EMGcorp.com p 800.733.0660
#7: PLAY STRUCTURE, LARGE
#8: RETAINING WALL, BRICK/STONE
#9: PLAY SURFACES & SPORTS
COURTS, WOOD CHIPS
#10: SIGNAGE, PROPERTY,
MONUMENT
#11: PLAY SURFACES & SPORTS
COURTS, ASPHALT
#12: SITE FURNISHINGS, PARK
BENCH, METAL/PLASTIC
NON- KIWANIS PARK SHELTER EMG PROJECT NO.: 122700.17R000-009.366
www.EMGcorp.com p 800.733.0660
#13: PLAY STRUCTURE, SWING SET
#14: POLE LIGHT, EXTERIOR
#15: FENCES & GATES, CHAIN LINK
#16: FOUNDATIONS, CONCRETE
SLAB-ON-GRADE
#17: EXTERIOR, PAINTED SURFACE
#18: ROOF, METAL
NON- KIWANIS PARK SHELTER EMG PROJECT NO.: 122700.17R000-009.366
www.EMGcorp.com p 800.733.0660
#19: ROOF, MISSING EDGE
#20: DRINKING FOUNTAIN,
REFRIGERATED
NON- KIWANIS PARK SHELTER EMG PROJECT NO.: 122700.17R000-009.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Non- Kiwanis Park Shelter
Project Number:
122700.17R000-009.366
Source:
Google Maps
On-Site Date:
May 22, 2017
NON- KIWANIS PARK SHELTER EMG PROJECT NO.: 122700.17R000-009.366
www.EMGcorp.com p 800.733.0660
Appendix C:
ADA Checklist
Page 1 of 4
Date Completed: June 6, 2017
Property Name: Non-Kiwanis Park Shelter
EMG Project Number: 122700.17R000-009.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X All park are CPSC/ADA/ASTM compliant.
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Riverfront Rental Building
131 East Hydraulic Avenue Units A, B, C
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-010.322 June 13, 2017 May 23, 2017
FACILITY CONDITION ASSESSMENT
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1. Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
1.3. Special Issues and Follow-Up Recommendations ...................................................................... 3
1.4. Opinions of Probable Cost .......................................................................................................... 3
1.4.1. Methodology ................................................................................................................................ 4
1.4.2. Immediate Repairs ...................................................................................................................... 4
1.4.3. Replacement Reserves ............................................................................................................... 4
2. Purpose and Scope .............................................................................................................................. 5
2.1. Purpose ....................................................................................................................................... 5
2.2. Scope .......................................................................................................................................... 6
2.3. Personnel Interviewed ................................................................................................................. 6
2.4. Documentation Reviewed ........................................................................................................... 7
2.5. Pre-Survey Questionnaire ........................................................................................................... 7
2.6. Weather Conditions ..................................................................................................................... 7
3. Accessibility and Property Research ................................................................................................. 8
3.1. ADA Accessibility ........................................................................................................................ 8
3.2. Municipal Information, Flood Zone and Seismic Zone ................................................................ 8
4. Existing Building Assessment ............................................................................................................ 9
4.1. Unit or Space Types .................................................................................................................... 9
4.2. Inaccessible Areas or Key Spaces Not Observed ...................................................................... 9
5. Site Improvements ............................................................................................................................. 10
5.1. Utilities ....................................................................................................................................... 10
5.2. Parking, Paving, and Sidewalks ................................................................................................ 10
5.3. Drainage Systems and Erosion Control .................................................................................... 11
5.4. Topography and Landscaping ................................................................................................... 12
5.5. General Site Improvements ....................................................................................................... 12
6. Building Architectural and Structural Systems ............................................................................... 14
6.1. Foundations ............................................................................................................................... 14
6.2. Superstructure ........................................................................................................................... 14
6.3. Roofing ...................................................................................................................................... 14
6.4. Exterior Walls ............................................................................................................................ 16
6.5. Exterior and Interior Stairs ......................................................................................................... 16
6.6. Exterior Windows and Doors ..................................................................................................... 16
6.7. Patio, Terrace, and Balcony ...................................................................................................... 17
7. Building Mechanical and Plumbing Systems .................................................................................. 18
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC) ..................................................... 18
7.2. Building Plumbing and Domestic Hot Water ............................................................................. 19
7.3. Building Gas Distribution ........................................................................................................... 20
7.4. Building Electrical ...................................................................................................................... 20
7.5. Building Elevators and Conveying Systems .............................................................................. 20
7.6. Fire Protection and Security Systems ....................................................................................... 21
7.7. Life Support Systems ................................................................................................................ 21
8. Interior Spaces .................................................................................................................................... 22
8.1. Interior Finishes ......................................................................................................................... 22
8.2. Commercial Kitchen & Laundry Equipment .............................................................................. 23
9. Other Structures ................................................................................................................................. 24
10. Certification ......................................................................................................................................... 25
11. Appendices ......................................................................................................................................... 26
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
1
www.EMGcorp.com p 800.733.0660
1. Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 131 E Hydraulic Ave, Yorkville, Kendall, IL 60560
Year Constructed/Renovated: 1970
Current Occupants: Foxy’s Ice Cream
Ginger + Soul
Percent Utilization: 100%
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Retail
Site Area: 0.07 acres
Building Area: 2,152 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: Parking available in public lot and on street. Public lot included in separate report.
Building Construction: Conventional wood frame structure on concrete slab
Roof Construction: Gabled roof with metal finish – Ginger + Soul
Flat roof with built-up membrane – Foxy’s Ice Cream
Exterior Finishes: Vinyl Siding – Ginger + Soul
Painted CMU – Foxy’s Ice Cream
Heating, Ventilation & Air Conditioning: Individual split-system units.
Supplemental components: air curtain.
Fire and Life/Safety: Hydrants, smoke detectors, extinguishers, exit signs, and emergency battery-powered
lighting.
Dates of Visit: May 23, 2017
On-Site Point of Contact (POC): Scott Sleezer
Assessment and Report Prepared by: Paul Prusa
Reviewed by:
Al Diefert
Technical report Reviewer For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC Fair
Structure Good Plumbing Fair
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
2
www.EMGcorp.com p 800.733.0660
Systemic Condition Summary
Roof
Excellent – Foxy’s Ice Cream
Fair – Ginger + Soul Electrical Fair
Vertical Envelope Fair Elevators --
Interiors Fair Fire --
The following bullet points highlight the most significant short term and modernization recommendations:
Replacement of furnace
Replacement of water heater
Installation of a complete fire suppression system
Installation of a complete fire alarm system
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained in recent years and is in fair overall condition.
According to property management personnel, the property has had a limited capital improvement expenditure program over the past
three years, primarily consisting of painting, asphalt pavement seal coating, and roof finish replacement. Supporting documentation
was not provided in support of these claims but some of the work is evident.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
3
www.EMGcorp.com p 800.733.0660
Fci Condition Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 5.4% Fair
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 20.6% Poor
Current Replacement Value (CRV) 2,152 SF * 183.24 / SF = $394,326
Year 0 (Current Year) - Immediate Repairs (IR) $21,625
Years 1-10 – Replacement Reserves (RR) $81,566
Total Capital Needs $103,191
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Installation of a complete fire suppression system
Installation of a complete fire alarm system
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
1.3. Special Issues and Follow-Up Recommendations
As part of the FCA, a limited assessment of accessible areas of the building(s) was performed to determine the presence of fungal
growth, conditions conducive to fungal growth, and/or evidence of moisture. Property personnel were interviewed concerning any
known or suspected fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Sampling is not a part of this
assessment.
There are no visual indications of the presence of fungal growth, conditions conducive to fungal growth, or evidence of moisture in
representative readily accessible areas of the property.
1.4. Opinions of Probable Cost
Cost estimates are attached at the front of this report (following the cover page).
These estimates are based on Invoice or Bid Document/s provided either by the Owner/facility and construction costs developed by
construction resources such as R.S. Means and Marshall & Swift, EMG’s experience with past costs for similar properties, city cost
indexes, and assumptions regarding future economic conditions.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
4
www.EMGcorp.com p 800.733.0660
Opinions of probable costs should only be construed as preliminary, order of magnitude budgets. Actual costs most probably will vary
from the consultant’s opinions of probable costs depending on such matters as type and design of suggested remedy, quality of
materials and installation, manufacturer and type of equipment or system selected, field conditions, whether a physical deficiency is
repaired or replaced in whole, phasing of the work (if applicable), quality of contractor, quality of project management exercised, market
conditions, and whether competitive pricing is solicited, etc. ASTM E2018-08 recognizes that certain opinions of probable costs cannot
be developed within the scope of this guide without further study. Opinions of probable cost for further study should be included in the
FCA.
1.4.1. Methodology
Based upon site observations, research, and judgment, along with referencing Expected Useful Life (EUL) tables from various industry
sources, EMG opines as to when a system or component will most probably necessitate replacement. Accurate historical replacement
records, if provided, are typically the best source of information. Exposure to the elements, initial quality and installation, extent of use,
the quality and amount of preventive maintenance exercised, etc., are all factors that impact the effective age of a system or
component. As a result, a system or component may have an effective age that is greater or less than its actual chronological age.
The Remaining Useful Life (RUL) of a component or system equals the EUL less its effective age. Projections of Remaining Useful Life
(RUL) are based on continued use of the Property similar to the reported past use. Significant changes in occupants and/or usage may
affect the service life of some systems or components.
Where quantities could not be derived from an actual take-off, lump sum costs or allowances are used. Estimated costs are based on
professional judgment and the probable or actual extent of the observed defect, inclusive of the cost to design, procure, construct and
manage the corrections.
1.4.2. Immediate Repairs
Immediate repairs are opinions of probable costs that require immediate action as a result of: (1) material existing or potential unsafe
conditions, (2) material building or fire code violations, or (3) conditions that, if not addressed, have the potential to result in, or
contribute to, critical element or system failure within one year or will most probably result in a significant escalation of its remedial cost.
1.4.3. Replacement Reserves
Replacement Reserves are for recurring probable expenditures, which are not classified as operation or maintenance expenses. The
replacement reserves should be budgeted for in advance on an annual basis. Replacement Reserves are reasonably predictable both
in terms of frequency and cost. However, Replacement Reserves may also include components or systems that have an
indeterminable life but, nonetheless, have a potential for failure within an estimated time period.
Replacement Reserves exclude systems or components that are estimated to expire after the reserve term and are not considered
material to the structural and mechanical integrity of the subject property. Furthermore, systems and components that are not deemed
to have a material effect on the use of the Property are also excluded. Costs that are caused by acts of God, accidents, or other
occurrences that are typically covered by insurance, rather than reserved for, are also excluded.
Replacement costs are solicited from ownership/property management, EMG’s discussions with service companies, manufacturers'
representatives, and previous experience in preparing such schedules for other similar facilities. Costs for work performed by the
ownership’s or property management’s maintenance staff are also considered.
EMG’s reserve methodology involves identification and quantification of those systems or components requiring capital reserve funds
within the assessment period. The assessment period is defined as the effective age plus the reserve term. Additional information
concerning system’s or component’s respective replacement costs (in today's dollars), typical expected useful lives, and remaining
useful lives were estimated so that a funding schedule could be prepared. The Replacement Reserves Schedule presupposes that all
required remedial work has been performed or that monies for remediation have been budgeted for items defined in the Immediate
Repair Cost Estimate.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
5
www.EMGcorp.com p 800.733.0660
2. Purpose and Scope
2.1. Purpose
EMG was retained by the client to render an opinion as to the Property’s current general physical condition on the day of the site visit.
Based on the observations, interviews and document review outlined below, this report identifies significant deferred maintenance
issues, existing deficiencies, and material code violations of record at municipal offices, which affect the Property’s use. Opinions are
rendered as to its structural integrity, building system condition and the Property’s overall condition. The report also notes building
systems or components that have realized or exceeded their typical expected useful lives.
CONDITIONS:
The physical condition of building systems and related components are typically defined as being in one of five conditions: Excellent,
Good, Fair, Poor, Failed or a combination thereof. For the purposes of this report, the following definitions are used:
Excellent = New or very close to new; component or system typically has been installed within the past year, sound and
performing its function. Eventual repair or replacement will be required when the component or system either
reaches the end of its useful life or fails in service.
Good = Satisfactory as-is. Component or system is sound and performing its function, typically within the first third of its
lifecycle. However, it may show minor signs of normal wear and tear. Repair or replacement will be required
when the component or system either reaches the end of its useful life or fails in service.
Fair = Showing signs of wear and use but still satisfactory as-is, typically near the median of its estimated useful life.
Component or system is performing adequately at this time but may exhibit some signs of wear, deferred
maintenance, or evidence of previous repairs. Repair or replacement will be required due to the component or
system’s condition and/or its estimated remaining useful life.
Poor = Component or system is significantly aged, flawed, functioning intermittently or unreliably; displays obvious
signs of deferred maintenance; shows evidence of previous repair or workmanship not in compliance with
commonly accepted standards; has become obsolete; or exhibits an inherent deficiency. The present condition
could contribute to or cause the deterioration of contiguous elements or systems. Either full component
replacement is needed or repairs are required to restore to good condition, prevent premature failure, and/or
prolong useful life.
Failed
= Component or system has ceased functioning or performing as intended. Replacement, repair, or other
significant corrective action is recommended or required.
Not Applicable
= Assigning a condition does not apply or make logical sense, most commonly due to the item in question not
being present.
Throughout sections 5 through 9 of this report, each report section will typically contain three subsections organized in the following
sequence:
A descriptive table (and/or narrative), which identifies the components assessed, their condition, and other key data points.
A simple bulleted list of Anticipated Lifecycle Replacements, which lists components and assets typically in Excellent, Good, or Fair
condition at the time of the assessment but that will require replacement or some other attention once aged past their estimated
useful life. These listed components are typically included in the associated inventory database with costs identified and budgeted
beyond the first several years.
A bulleted cluster of Actions/Comments, which include more detailed narratives describing deficiencies, recommended repairs, and
short term replacements. The assets and components associated with these bullets are/were typically problematic and in Poor or
Failed condition at the time of the assessment, with corresponding costs included within the first few years.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
6
www.EMGcorp.com p 800.733.0660
PLAN TYPES:
Each line item in the cost database is assigned a Plan Type, which is the primary reason or rationale for the recommended
replacement, repair, or other corrective action. This is the “why” part of the equation. A cost or line item may commonly have more
than one applicable Plan Type; however, only one Plan Type will be assigned based on the “best” fit, typically the one with the greatest
significance. The following Plan Types are listed in general weighted order of importance:
Safety = An observed or reported unsafe condition that if left unaddressed could result in an injury; a system
or component that presents a potential liability risk.
Performance/Integrity = Component or system has failed, is almost failing, performs unreliably, does not perform as intended,
and/or poses a risk to overall system stability.
Accessibility = Does not meet ADA, UFAS, and/or other handicap accessibility requirements.
Environmental = Improvements to air or water quality, including removal of hazardous materials from the building or
site.
Modernization/Adaptation
= Conditions, systems, or spaces that need to be upgraded in appearance or function to meet current
standards, facility usage, or client/occupant needs.
Lifecycle/Renewal
= Any component or system in which future repair or replacement is anticipated beyond the next
several years and/or is of minimal substantial early-term consequence.
2.2. Scope
The standard scope of the Facility Condition Assessment includes the following:
Visit the Property to evaluate the general condition of the building and site improvements, review available construction documents in
order to familiarize ourselves with, and be able to comment on, the in-place construction systems, life safety, mechanical, electrical,
and plumbing systems, and the general built environment.
Identify those components that are exhibiting deferred maintenance issues and provide cost estimates for Immediate Costs and
Replacement Reserves based on observed conditions, maintenance history and industry standard useful life estimates. This will
include the review of documented capital improvements completed within the last five-year period and work currently contracted for, if
applicable.
Provide a full description of the Property with descriptions of in-place systems and commentary on observed conditions.
Provide a general statement of the subject Property’s compliance to Title III of the Americans with Disabilities Act. This will not
constitute a full ADA survey, but will help identify exposure to issues and the need for further review.
Perform a limited assessment of accessible areas of the building(s) for the presence of fungal growth, conditions conducive to fungal
growth, and/or evidence of moisture. EMG will also interview Project personnel regarding the presence of any known or suspected
fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Potentially affected areas will be photographed.
Sampling will not be considered in routine assessments.
List the current utility service providers.
Review maintenance records and procedures with the in-place maintenance personnel.
Observe a representative sample of the interior spaces/units, including vacant spaces/units, in order to gain a clear understanding of
the property’s overall condition. Other areas to be observed include the exterior of the property, the roofs, interior common areas,
and the significant mechanical, electrical and elevator equipment rooms.
Provide an Executive Summary at the beginning of this report.
Prepare a mechanical equipment inventory list.
2.3. Personnel Interviewed
The building engineer was interviewed for specific information relating to the physical property, available maintenance procedures,
historical performance of key building systems and components, available drawings and other documentation. The following personnel
from the facility and government agencies were interviewed in the process of conducting the FCA:
Name and Title Organization Phone Number
Scott Sleezer Parks and Recreation 630.878.7291
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
7
www.EMGcorp.com p 800.733.0660
The FCA was performed with the assistance of Scott Sleezer, Yorkville Parks and Recreation, the onsite Point of Contact (POC), who
was cooperative and provided information that appeared to be accurate based upon subsequent site observations. The onsite contact
is completely knowledgeable about the subject property and answered most questions posed during the interview process. The POC’s
management involvement at the property has been for the past 26 years.
2.4. Documentation Reviewed
Prior to the FCA, relevant documentation was requested that could aid in the knowledge of the subject property’s physical
improvements, extent and type of use, and/or assist in identifying material discrepancies between reported information and observed
conditions. The review of submitted documents does not include comment on the accuracy of such documents or their preparation,
methodology, or protocol. The Documentation Request Form is provided in Appendix E.
2.5. Pre-Survey Questionnaire
A Pre-Survey Questionnaire was sent to the POC prior to the site visit and was not returned. The questionnaire is included in Appendix
E.
2.6. Weather Conditions
May 23, 2017: Raining, with temperatures in the 70s (°F) and light winds.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
8
www.EMGcorp.com p 800.733.0660
3. Accessibility and Property Research
3.1. ADA Accessibility
Generally, Title III of the Americans with Disabilities Act (ADA) prohibits discrimination by entities to access and use of “areas of public
accommodations” and “commercial facilities” on the basis of disability. Regardless of its age, these areas and facilities must be
maintained and operated to comply with the Americans with Disabilities Act Accessibility Guidelines (ADAAG).
Buildings completed and occupied after January 26, 1992 are required to comply fully with the ADAAG. Existing facilities constructed
prior to this date are held to the lesser standard of compliance to the extent allowed by structural feasibility and the financial resources
available. As an alternative, a reasonable accommodation pertaining to the deficiency must be made.
During the FCA, a limited visual observation for ADA accessibility compliance was conducted. The scope of the visual observation was
limited to those areas set forth in EMG’s Abbreviated Accessibility Checklist provided in Appendix D of this report. It is understood by
the Client that the limited observations described herein does not comprise a full ADA Compliance Survey, and that such a survey is
beyond the scope of EMG’s undertaking. Only a representative sample of areas was observed and, other than as shown on the
Abbreviated Accessibility Checklist, actual measurements were not taken to verify compliance.
At a retail property, the areas considered as a public accommodation besides the site itself and parking, are the exterior accessible
route, the interior accessible route up to the tenant lease lines and the interior common areas, including the common area restrooms.
The facility does not appear to be accessible with Title III of the Americans with Disabilities Act. Elements as defined by the ADAAG
that are not accessible as stated within the priorities of Title III, are as follows:
Restrooms
Wrap drain pipes below lavatory with insulation; protect against contact with hot, sharp, or abrasive surfaces.
A full ADA Compliance Survey may reveal additional aspects of the property that are not in compliance.
Corrections of these conditions should be addressed from a liability standpoint, but are not necessarily code violations. The Americans
with Disabilities Act Accessibility Guidelines concern civil rights issues as they pertain to the disabled and are not a construction code,
although many local jurisdictions have adopted the Guidelines as such. The cost to address the achievable items noted above is
included in the cost tables.
3.2. Municipal Information, Flood Zone and Seismic Zone
Not Applicable.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
9
www.EMGcorp.com p 800.733.0660
4. Existing Building Assessment
4.1. Unit or Space Types
All 2,152 square feet of the building are occupied by a multiple occupants, Foxy’s Ice Cream and Ginger + Soul. The building is owned
and maintained by the City of Yorkville Parks and Recreation Department. The spaces are a combination of kitchens, dining areas,
supporting restrooms, mechanical, and other utility spaces.
The following table identifies the reported unit types and mix at the subject property.
Unit Types and Mix
Quantity Type Floor Area (Sf)
1 Ginger + Soul 1,440
1 Foxy’s Ice Cream 625
1 Shared Mechanical Space 87
TOTAL 2,152
4.2. Inaccessible Areas or Key Spaces Not Observed
The interior spaces were observed in order to gain a clear understanding of the property’s overall condition. Other areas accessed
included the site within the property boundaries, exterior of the property, and the roof. All areas of the property were available for
observation during the site visit.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
10
www.EMGcorp.com p 800.733.0660
5. Site Improvements
5.1. Utilities
The following table identifies the utility suppliers and the condition and adequacy of the services.
Site Utilities
Utility Supplier Condition and Adequacy
Sanitary sewer City of Yorkville Good
Storm sewer City of Yorkville Good
Domestic water City of Yorkville Good
Electric service Commonwealth Edison Good
Natural gas service Nicor Gas Good
Actions/Comments:
According to the POC, the utilities provided are adequate for the property. There are no unique, onsite utility systems such as
emergency electrical generators, septic systems, water or waste water treatment plants, or propane gas tanks.
5.2. Parking, Paving, and Sidewalks
Item Description
Main Ingress and Egress Hydraulic Ave
Access from South
Additional Entrances --
Additional Access from --
Paving and Flatwork
Item Material Last Work Done Condition
Entrance Driveway Apron -- -- --
Parking Lot -- -- --
Drive Aisles -- -- --
Service Aisles -- -- --
Sidewalks -- -- --
Curbs -- -- --
Site Stairs -- -- --
Pedestrian Ramps -- -- --
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
11
www.EMGcorp.com p 800.733.0660
Parking Count
Open Lot Carport Private Garage Subterranean Garage Freestanding Parking
Structure
-- -- -- -- --
Total Number of ADA Compliant Spaces 0
Number of ADA Compliant Spaces for Vans 0
Total Parking Spaces Utilizes Public Lot
Parking Ratio (Spaces/Apartments) --
Method of Obtaining Parking Count --
Exterior Stairs
Location Material Handrails Condition
None -- -- --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended.
5.3. Drainage Systems and Erosion Control
Drainage System and Erosion Control
System Exists At Site Condition
Surface Flow ☒ Good
Inlets ☐ --
Swales ☐ --
Detention pond ☐ --
Lagoons ☐ --
Ponds ☐ --
Underground Piping ☐ --
Pits ☐ --
Municipal System ☐ --
Dry Well ☐ --
Anticipated Lifecycle Replacements:
No components of significance
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
12
www.EMGcorp.com p 800.733.0660
Actions/Comments:
There is no evidence of storm water runoff from adjacent properties. The storm water system appears to provide adequate runoff
capacity. There is no evidence of major ponding or erosion.
5.4. Topography and Landscaping
Item Description
Site Topography Generally flat
Landscaping
Trees Grass Flower Beds Planters
Drought
Tolerant
Plants
Decorative Stone None
☐ ☐ ☐ ☐ ☐ ☐ ☒
Landscaping Condition --
Irrigation Automatic Underground Drip Hand Watering None
☐ ☐ ☐ ☒
Irrigation Condition --
Retaining Walls
Type Location Condition
None -- --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The topography and adjacent uses do not appear to present conditions detrimental to the property. There are no significant areas of
erosion.
5.5. General Site Improvements
Property Signage
Property Signage Building mounted
Street Address Displayed? Yes
Site and Building Lighting
Site Lighting
None Pole Mounted Bollard Lights Ground Mounted Parking Lot Pole
Type
☒ ☐ ☐ ☐ ☐
--
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
13
www.EMGcorp.com p 800.733.0660
Site and Building Lighting
Building Lighting
None Wall Mounted Recessed Soffit
☐ ☒ ☐
Good – Foxy’s Ice Cream
Fair – Ginger + Soul
Site Fencing
Type Location Condition
None -- --
REFUSE DISPOSAL
Refuse Disposal Common area dumpsters
Dumpster Locations Mounting Enclosure Contracted? Condition
Public Lot Asphalt paving Wood board fence Yes Excellent
Other Site Amenities
Description Location Condition
Playground Equipment None -- --
Tennis Courts None -- --
Basketball Court None -- --
Swimming Pool None -- --
Anticipated Lifecycle Replacements:
Exterior lighting
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
14
www.EMGcorp.com p 800.733.0660
6. Building Architectural and Structural Systems
6.1. Foundations
Building Foundation
Item Description Condition
Foundation Slab on grade with integral footings Good
Basement and Crawl Space None --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The foundation systems are concealed. There are no significant signs of settlement, deflection, or movement.
6.2. Superstructure
Building Superstructure
Item Description Condition
Framing / Load-Bearing Walls Conventional wood/metal studs Good
Ground Floor Concrete slab Good
Upper Floor Framing -- --
Upper Floor Decking -- --
Roof Framing Wood trusses Good
Roof Decking Plywood or OSB Good
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The superstructure is exposed in some locations, which allows for limited observation. Walls and floors appear to be plumb, level,
and stable. There are no significant signs of deflection or movement.
6.3. Roofing
Primary Roof
Type / Geometry Flat Finish Modified Bituminous
Maintenance Outside Contractor Roof Age 0 Yrs
Flashing Membrane Warranties Yes
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
15
www.EMGcorp.com p 800.733.0660
Primary Roof
Parapet Copings Parapet with sheet metal coping Roof Drains Gutters and downspouts
Fascia Metal Panel Insulation Rigid Board
Soffits Concealed Soffits Skylights No
Attics -- Ponding No
Ventilation Source-1 Turtle Vents Leaks Observed No
Ventilation Source-2 -- Roof Condition Excellent
The primary roof is located at Foxy’s Ice Cream and Share Mechanical Space.
Secondary Roof
Type / Geometry Gable Roof Finish Metal
Maintenance Outside Contractor Roof Age Approximately 20 Yrs
Flashing Membrane Warranties No
Parapet Copings None Roof Drains Gutters and downspouts
Fascia Metal Panel Insulation Fiberglass batts
Soffits None Skylights No
Attics Wood joists with plywood sheathing Ponding No
Ventilation Source-1 Ridge Vents Leaks Observed No
Ventilation Source-2 -- Roof Condition Fair
The secondary roof is located at Ginger + Soul.
Anticipated Lifecycle Replacements:
Metal roofing
Modified bituminous membrane
Roof flashings (included as part of overall membrane replacement)
Parapet wall copings (included as part of overall membrane replacement)
Actions/Comments:
The roof finishes vary in age. Information regarding roof warranties or bonds was not available. The roofs are maintained by an
outside contractor.
According to the POC, there are no active roof leaks. There is no evidence of active roof leaks.
There is no evidence of roof deck or insulation deterioration. The roof substrate and insulation should be inspected during any future
roof repair or replacement work.
Roof drainage appears to be adequate. Clearing and minor repair of drain system components should be performed regularly as part
of the property management’s routine maintenance and operations program.
The attics are not accessible and it could not be determined if there is moisture, water intrusion, or excessive daylight in the attics.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
16
www.EMGcorp.com p 800.733.0660
6.4. Exterior Walls
Foxy’s Ice Cream Building Exterior Walls
Type Location Condition
Primary Finish Painted CMU Good
Secondary Finish -- --
Accented with Wood siding Fair
Soffits Concealed Fair
Ginger + Soul Building Exterior Walls
Type Location Condition
Primary Finish Vinyl siding Fair
Secondary Finish -- --
Accented with -- --
Soffits -- --
Building sealants (caulking) are located between dissimilar materials, at joints, and around window and door openings.
Anticipated Lifecycle Replacements:
Exterior paint
Vinyl siding
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance, including patching repairs, graffiti removal,
and re-caulking, is highly recommended. Future lifecycle replacements of the components listed above will be required.
6.5. Exterior and Interior Stairs
Not applicable. There are no exterior or interior stairs.
6.6. Exterior Windows and Doors
Building Windows
Window Framing Glazing Location Window
Screen Condition
Vinyl framed, operable Double glaze Foxy’s Ice Cream ☐ Fair
Aluminum framed, fixed Double glaze Ginger + Soul ☐ Fair
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
17
www.EMGcorp.com p 800.733.0660
Building Doors
Main Entrance Doors Door Type Condition
Glazed, metal framed Good
Secondary Entrance Doors -- --
Service Doors -- --
Overhead Doors -- --
Anticipated Lifecycle Replacements:
Windows
Exterior glazed metal doors
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
6.7. Patio, Terrace, and Balcony
Building Patio, Terrace and Balcony
Type Description Location Condition
Ground Floor Patio Asphalt Rear – Ginger + Soul
Front – Foxy’s Ice Cream
Poor
Excellent
Upper Balcony Structure -- -- --
Balcony Decks -- -- --
Balcony Deck Toppings -- -- --
Balcony Guardrails -- -- --
Anticipated Lifecycle Replacements:
Seal coating of asphalt pavement
Actions/Comments:
The rear patio asphalt must be seal coated in order to maintain the integrity of the overall pavement system.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
18
www.EMGcorp.com p 800.733.0660
7. Building Mechanical and Plumbing Systems
See the Mechanical Equipment List in the Appendices for the quantity, manufacturer’s name, model number, capacity and year of
manufacturer of the major mechanical equipment, if available.
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC)
Individual Units
Primary Components Split system furnaces and condensing units
Cooling (if separate from above) performed via components above
Quantity and Capacity Ranges 2 units at 2.5 tons each
Total Heating or Cooling Capacity 5 tons
Heating Fuel Natural gas
Location of Equipment Building exterior
Space Served by System Entire building
Age Ranges 2016 – Foxy’s Ice Cream
2006 – Ginger + Soul
Primary Component Condition Excellent – Foxy’s Ice Cream
Fair – Ginger + Soul
Supplemental Components
Supplemental Component #1 Air Curtain
Location / Space Served by Air Curtain Foxy’s Ice Cream kitchen area
Air Curtain Condition Fair
Anticipated Lifecycle Replacements:
Split system furnaces and condensing units
Air curtain
Actions/Comments:
The HVAC systems are maintained by the in-house maintenance staff.
The HVAC equipment varies in age. HVAC equipment is replaced on an "as needed" basis.
The HVAC equipment appears to be functioning adequately overall. The engineering staff was interviewed about the historical and
recent performance of the equipment and systems. No chronic problems were reported and an overall sense of satisfaction with the
systems was conveyed. However, due to the inevitable failure of parts and components over time, some of the equipment will
require replacement. A budgetary cost for this work is included.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
19
www.EMGcorp.com p 800.733.0660
7.2. Building Plumbing and Domestic Hot Water
Building Plumbing System
Type Description Condition
Water Supply Piping Copper Fair
Waste/Sewer Piping PVC Fair
Vent Piping PVC Fair
Water Meter Location Shared Space Mechanical Room
Domestic Water Heaters or Boilers
Components Water Heaters
Fuel Electric
Quantity and Input Capacity
2 units
4,500 W – Ginger + Soul
Inaccessible – Foxy’s Ice Cream
Storage Capacity 50 gallons – Ginger + Soul
Approximately 40 gallons – Foxy’s Ice Cream
Boiler or Water Heater Condition Excellent – Ginger + Soul
Poor – Foxy’s Ice Cream
Supplementary Storage Tanks? No
Storage Tank Quantity & Volume --
Quantity of Storage Tanks --
Storage Tank Condition --
Domestic Hot Water Circulation Pumps (3 HP and over) No
Adequacy of Hot Water Adequate
Adequacy of Water Pressure Adequate
Plumbing Fixtures
Water Closets Residential grade
Toilet (Water Closet) Flush Rating 1,6 GPF
Common Area Faucet Nominal Flow Rate 2.0 GPM
Condition Good
Anticipated Lifecycle Replacements:
Water heaters
Toilets
Sinks
Lavatories
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
20
www.EMGcorp.com p 800.733.0660
Actions/Comments:
The plumbing systems appear to be well maintained and functioning adequately. The water pressure appears to be sufficient. No
significant repair actions or short term replacement costs are required. Routine and periodic maintenance is recommended. Future
lifecycle replacements of the components or systems listed above will be required.
7.3. Building Gas Distribution
Gas service is supplied from the gas main on the adjacent public street. The gas meter and regulator are located along the exterior
walls of the buildings. The gas distribution piping within each building is malleable steel (black iron).
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The pressure and quantity of gas appear to be adequate.
The gas meter and regulator appear to be functioning adequately and will require routine maintenance.
Only limited observation of the gas distribution piping can be made due to hidden conditions.
7.4. Building Electrical
Building Electrical Systems
Electrical Lines Overhead Transformer Pole-mounted
Main Service Size (2) 200 Amps Volts 120/240 Volt, single-phase
Meter & Panel Location West side Branch Wiring Copper
Conduit Metallic Step-Down Transformers? No
Security / Surveillance System? Yes Building Intercom System? No
Lighting Fixtures T-8
Main Distribution Condition Fair
Secondary Panel and Transformer
Condition --
Lighting Condition Fair
Anticipated Lifecycle Replacements:
Circuit breaker panels
Interior light fixtures
Actions/Comments:
The onsite electrical systems up to the meters are owned and maintained by the respective utility company.
The electrical service and capacity appear to be adequate for the property’s demands.
The panels are mostly original 1970 components. The electrical service is reportedly adequate for the facility’s needs. However, due
to the age of the panels and increasing difficulty of obtaining replacement parts over time, lifecycle replacements are recommended
per above.
7.5. Building Elevators and Conveying Systems
Not applicable. There are no elevators or conveying systems.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
21
www.EMGcorp.com p 800.733.0660
7.6. Fire Protection and Security Systems
Item Description
Type None
Fire Alarm System
Central Alarm Panel ☐ Battery-Operated Smoke
Detectors ☒ Alarm Horns ☐
Annunciator Panels ☐ Hard-Wired Smoke
Detectors ☐ Strobe Light Alarms ☐
Pull Stations ☐ Emergency Battery-Pack
Lighting ☒ Illuminated EXIT Signs ☒
Alarm System
Condition --
Sprinkler System
None ☒ Standpipes ☐ Backflow Preventer ☐
Hose Cabinets ☐ Fire Pumps ☐ Siamese Connections ☐
Suppression Condition --
Central Alarm Panel
System
Location of Alarm Panel Installation Date of Alarm Panel
-- --
Fire Extinguishers
Last Service Date Servicing Current?
08/2015 & 03/2017 No
Hydrant Location Hydraulic Avenue
Siamese Location --
Special Systems Kitchen Suppression System ☐Computer Room Suppression System ☐
Anticipated Lifecycle Replacements:
Central alarm panel
Alarm devices and system
Sprinkler heads
Actions/Comments:
The building is not protected by fire suppression. Due to its construction date, the facility is most likely “grandfathered” by code and the
installation of fire sprinklers not required until major renovations are performed. Regardless of when or if installation of facility-wide fire
suppression is required by the governing municipality, EMG recommends a retrofit be performed. A budgetary cost is included.
The fire alarm systems appear limited to locally alarmed devices. There is a lack of strobes, audio alarms, insufficient pull stations,
and system alarms locally only. Due to the age of the components and apparent shortcomings, a full modernization project is
recommended. A budgetary cost is included.
7.7. Life Support Systems
Not Applicable.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
22
www.EMGcorp.com p 800.733.0660
8. Interior Spaces
8.1. Interior Finishes
The facility is used as a restaurant and ice cream shop. The most significant interior spaces include dining areas and kitchens.
Supporting areas include hallways, restrooms, and back-of-house areas.
The following table generally describes the locations and typical conditions of the interior finishes within the facility:
Typical Floor Finishes
Floor Finish Locations General Condition
Vinyl tile Ginger + Soul kitchen, Foxy’s Ice Cream Fair
Ceramic tile Ginger + Soul corridor and restrooms Good
Painted/sealed concrete Ginger + Soul dining area Fair
Wood strip Ginger + Soul dining area Good
Typical Wall Finishes
Wall Finish Locations General Condition
Painted CMU Foxy’s Ice Cream Fair
Painted drywall Ginger + Soul Fair
Typical Ceiling Finishes
Ceiling Finish Locations General Condition
Suspended T-bar (Acoustic) Foxy’s Ice Cream kitchen, throughout Ginger + Soul Fair
Exposed painted structure Foxy’s Ice Cream dining area Fair
Exposed structure Shared space mechanical room Fair
Interior Doors
Item Type Condition
Interior Doors
Hollow core wood
Fully glazed wood
Solid core metal
Fair
Door Framing Wood Fair
Fire Doors No --
Anticipated Lifecycle Replacements:
Vinyl tile
Ceramic tile
Interior paint
Suspended acoustic ceiling tile
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
23
www.EMGcorp.com p 800.733.0660
Interior doors
Actions/Comments:
It appears that the interior finishes have been renovated at different time.
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
8.2. Commercial Kitchen & Laundry Equipment
Not applicable. Commercial kitchen equipment is owned and maintained by the tenant.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
24
www.EMGcorp.com p 800.733.0660
9. Other Structures
Not applicable. There are no major accessory structures.
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
25
www.EMGcorp.com p 800.733.0660
10. Certification
City of Yorkville retained EMG to perform this Facility Condition Assessment in connection with its continued operation of Riverfront
Rental Building, 131 East Hydraulic Avenue, Yorkville, Illinois, the “Property”. It is our understanding that the primary interest of City of
Yorkville is to locate and evaluate materials and building system defects that might significantly affect the value of the property and to
determine if the present Property has conditions that will have a significant impact on its continued operations.
The conclusions and recommendations presented in this report are based on the brief review of the plans and records made available
to our Project Manager during the site visit, interviews of available property management personnel and maintenance contractors
familiar with the Property, appropriate inquiry of municipal authorities, our Project Manager’s walk-through observations during the site
visit, and our experience with similar properties.
No testing, exploratory probing, dismantling or operating of equipment or in depth studies were performed unless specifically required
under Section 2 of this report. This assessment did not include engineering calculations to determine the adequacy of the Property’s
original design or existing systems. Although walk-through observations were performed, not all areas were observed (See Section 4.2
for areas observed). There may be defects in the Property, which were in areas not observed or readily accessible, may not have been
visible, or were not disclosed by management personnel when questioned. The report describes property conditions at the time that
the observations and research were conducted.
This report has been prepared on behalf of and exclusively for the use of City of Yorkville for the purpose stated within Section 2 of this
report. The report, or any excerpt thereof, shall not be used by any party other than City of Yorkville or for any other purpose than that
specifically stated in our agreement or within Section 2 of this report without the express written consent of EMG.
Any reuse or distribution of this report without such consent shall be at City of Yorkville and the recipient’s sole risk, without liability to
EMG.
Prepared by: Paul Prusa P.E., LEED AP,
Project Manager
Reviewed by:
Al Diefert
Technical report Reviewer For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
26
www.EMGcorp.com p 800.733.0660
11. Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: EMG Accessibility Checklist
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
RIVERFRONT RENTAL BUILDING
131 EAST HYDRAULIC AVENUE UNITS A B C
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
#1: REAR ELEVATION - GINGER +
SOUL
#2: FRONT ELEVATION - FOXY'S ICE
CREAM
#3: LEFT ELEVATION - FOXY'S ICE
CREAM
#4: RIGHT ELEVATION - FOXY'S ICE
CREAM
#5: RIGHT ELEVATION - GINGER +
SOUL
#6: FRONT ELEVATION - GINGER +
SOUL
RIVERFRONT RENTAL BUILDING
131 EAST HYDRAULIC AVENUE UNITS A B C
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
#7: ADA, RESTROOM, LAVATORY
PIPE WRAPS
#8: ROOF, METAL
#9: ROOF, MODIFIED BITUMINOUS
#10: DAMAGED DOWNSPOUT
#11: EXTERIOR WALL, PAINTED
SURFACE
#12: EXTERIOR WALL, VINYL SIDING
RIVERFRONT RENTAL BUILDING
131 EAST HYDRAULIC AVENUE UNITS A B C
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
#13: WINDOW, VINYL-CLAD DOUBLE-
GLAZED 12 SF
#14: WINDOW, VINYL-CLAD DOUBLE-
GLAZED 6 SF
#15: WINDOW, ALUMINUM DOUBLE-
GLAZED
#16: EXTERIOR DOOR, STEEL W/
GLASS - GINGER + SOUL
#17: EXTERIOR DOOR, STEEL W/
GLASS - FOXY'S ICE CREAM
#18: PEDESTRIAN PAVEMENT,
ASPHALT - GINGER + SOUL
RIVERFRONT RENTAL BUILDING
131 EAST HYDRAULIC AVENUE UNITS A B C
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
#19: PEDESTRIAN PAVEMENT,
ASPHALT - FOXY'S ICE CREAM
#20: AIR CURTAIN
#21: CONDENSING UNIT - GINGER +
SOUL
#22: CONDENSING UNIT - FOXY'S ICE
CREAM
#23: FURNACE, GAS - GINGER +
SOUL
#24: FURNACE, GAS - FOXY'S ICE
CREAM
RIVERFRONT RENTAL BUILDING
131 EAST HYDRAULIC AVENUE UNITS A B C
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
#25: WATER HEATER, ELECTRIC -
GINGER + SOUL
#26: WATER HEATER, ELECTRIC -
FOXY'S ICE CREAM
#27: SINK, STAINLESS STEEL -
FOXY'S ICE CREAM
#28:
SINK, POT, MULTI-
COMPARTMENT - FOXY'S ICE
CREAM
#29: LAVATORY, VITREOUS CHINA
#30: TOILET, FLUSH TANK (WATER
CLOSET)
RIVERFRONT RENTAL BUILDING
131 EAST HYDRAULIC AVENUE UNITS A B C
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
#31:
SINK, POT, MULTI-
COMPARTMENT - GINGER +
SOUL
#32: SINK, PLASTIC
#33: LIGHTING SYSTEM, INTERIOR -
GINGER + SOUL
#34: LIGHTING SYSTEM, INTERIOR -
FOXY'S ICE CREAM
#35: MAIN DISTRIBUTION PANEL -
FOXY'S ICE CREAM
#36: MAIN DISTRIBUTION PANEL -
GINGER + SOUL
RIVERFRONT RENTAL BUILDING
131 EAST HYDRAULIC AVENUE UNITS A B C
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
#37: INCANDESCENT LIGHTING
FIXTURE, BASIC
#38: LED LIGHTING FIXTURE, BASIC
#39: FLOOD LIGHT, EXTERIOR
#40: EMERGENCY/EXIT COMBO
#41: FIRE EXTINGUISHER
#42: EXIT LIGHTING FIXTURE
RIVERFRONT RENTAL BUILDING
131 EAST HYDRAULIC AVENUE UNITS A B C
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
#43: CAMERA, SECURITY SYSTEM -
FOXY'S ICE CREAM
#44:
INTERIOR WALL FINISH,
GYPSUM BOARD - GINGER +
SOUL
#45:
INTERIOR WALL FINISH,
CONCRETE/MASONRY - FOXY'S
ICE CREAM
#46:
INTERIOR CEILING FINISH,
PAINTED STRUCTURE - FOXY'S
ICE CREAM
#47:
INTERIOR CEILING FINISH,
ACOUSTICAL TILE (ACT) -
GINGER + SOUL
#48:
INTERIOR CEILING FINISH, (ACT)
DROPPED FIBERGLASS -
GINGER + SOUL
RIVERFRONT RENTAL BUILDING
131 EAST HYDRAULIC AVENUE UNITS A B C
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
#49:
INTERIOR CEILING FINISH,
ACOUSTICAL TILE (ACT) -
FOXY'S ICE CREAM
#50: INTERIOR FLOOR FINISH,
CERAMIC TILE - GINGER + SOUL
#51: INTERIOR FLOOR FINISH, VINYL
TILE (VCT) - GINGER + SOUL
#52: INTERIOR FLOOR FINISH, VINYL
TILE (VCT) - FOXY'S ICE CREAM
#53: INTERIOR FLOOR FINISH, WOOD
STRIP - GINGER + SOUL
#54: INTERIOR FLOOR FINISH,
CONCRETE - GINGER + SOUL
RIVERFRONT RENTAL BUILDING
131 EAST HYDRAULIC AVENUE UNITS A B C
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
#55:
INTERIOR DOOR, WOOD
HOLLOW-CORE - GINGER +
SOUL
#56: INTERIOR DOOR, GLAZED WOOD
- GINGER + SOUL
#57: INTERIOR DOOR, STEEL -
FOXY'S ICE CREAM
#58:
INTERIOR DOOR, WOOD
HOLLOW-CORE - FOXY'S ICE
CREAM
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Riverfront Rental Building
Project Number:
122700.17R000-010.322
Source:
Google Maps
On-Site Date:
May 23, 2017
RIVERFRONT RENTAL BUILDING EMG PROJECT NO.: 122700.17R000-010.322
www.EMGcorp.com p 800.733.0660
Appendix C:
EMG Accessibility Checklist
Page 1 of 4
Date Completed: June 7, 2017
Property Name: Riverfront Rental Building
EMG Project Number: 122700.17R000-010.322
Building History Yes No Unk Comments
1
Has an ADA survey previously been completed
for this property? X
2
Have any ADA improvements been made to the
property? X
3
Does a Transition Plan / Barrier Removal Plan
exist for the property? X
4
Has building ownership or management
received any ADA related complaints that have
not been resolved?
X
5
Is any litigation pending related to ADA issues?
X
Parking Yes No NA Comments
1
Are there sufficient accessible parking spaces
with respect to the total number of reported
spaces?
X Parking is provided via a public lot (included in
separate report) and street parking.
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are there
signs reading “Van Accessible” at van spaces?
X
4
Is there at least one accessible route provided
within the boundary of the site from public
transportation stops, accessible parking spaces,
passenger loading zones, if provided, and public
streets and sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives, paths,
and drop-offs?
X
6
If required does signage exist directing you to
accessible parking and an accessible building
entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of travel
appear to meet slope requirements? ( 1:12 or
less) X
2
Are ramps that appear longer than 6 ft complete
with railings on both sides? X
3
Does the width between railings appear at least
36 inches? X
Page 2 of 4
Ramps Yes No NA Comments
4
Is there a level landing for approximately every
30 ft horizontal length of ramp, at the top and at
the bottom of ramps and switchbacks? X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance doorways
appear at least 32 inches wide and not a
revolving door? X
2
If the main entrance is inaccessible, are there
alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting required
and not higher than approximately 48 inches
above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction and
wide enough for a wheelchair (appear at least
36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet rooms,
exits, etc.) identified with signage? X
3
Is there a path of travel that does not require the
use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered and
answered when car arrives? X
2
Are there visual and audible signals inside cars
indicating floor change? X
3
Are there standard raised and Braille marking on
both jambs of each hoist way entrance as well
as all cab/call buttons? X
4
Do elevator doors have a reopening device that
will stop and reopen a car door if an object or a
person obstructs the door? X
5
Are elevator controls low enough to be reached
from a wheelchair (appears to be between 15
and 48 inches)? X
6
If a two-way emergency communication system
is provided within the elevator cab, is it usable
without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located on
an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm devices
in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround (appear
to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety alarms
with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have 29”
clearance)? X
10
Are sink handles operable with one hand without
grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms does
the property management report to have?
Provide specific number in comment field.
Are there sufficient reported accessible sleeping
rooms with respect to the total number of
reported guestrooms? See attached hot sheet.
X
2
How many of the accessible sleeping rooms per
property management have roll-in showers?
Provide specific number in comment field.
Are there sufficient reported accessible rooms
with roll-in showers with respect to the total
number of reported accessible guestrooms?
See attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
3
How many assistive listening kits and/or rooms
with communication features are available per
property management? Provide specific
number in comment field.
Are there sufficient reported assistive listening
devices with respect to the total number of
rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the answer
is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide number in
comment field.
Is at least one fixed lift or sloped entry to the
pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are subject
to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear floor
space around the machines/equipment (30” by
48” minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
River Front Park Building – Yak Shack
301 Hydraulic
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-013.322 June 22, 2017 May 23, 2017
FACILITY CONDITION ASSESSMENT
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
TABLE OF CONTENTS
1. Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
1.3. Special Issues and Follow-Up Recommendations ...................................................................... 3
1.4. Opinions of Probable Cost .......................................................................................................... 3
1.4.1. Methodology ................................................................................................................................ 4
1.4.2. Immediate Repairs ...................................................................................................................... 4
1.4.3. Replacement Reserves ............................................................................................................... 4
2. Purpose and Scope .............................................................................................................................. 5
2.1. Purpose ....................................................................................................................................... 5
2.2. Scope .......................................................................................................................................... 6
2.3. Personnel Interviewed ................................................................................................................. 6
2.4. Documentation Reviewed ........................................................................................................... 7
2.5. Pre-Survey Questionnaire ........................................................................................................... 7
2.6. Weather Conditions ..................................................................................................................... 7
3. Accessibility and Property Research ................................................................................................. 8
3.1. ADA Accessibility ........................................................................................................................ 8
3.2. Municipal Information, Flood Zone and Seismic Zone ................................................................ 8
4. Existing Building Assessment ............................................................................................................ 9
4.1. Unit or Space Types .................................................................................................................... 9
4.2. Inaccessible Areas or Key Spaces Not Observed ...................................................................... 9
5. Site Improvements ............................................................................................................................. 10
5.1. Utilities ....................................................................................................................................... 10
5.2. Parking, Paving, and Sidewalks ................................................................................................ 10
5.3. Drainage Systems and Erosion Control .................................................................................... 11
5.4. Topography and Landscaping ................................................................................................... 12
5.5. General Site Improvements ....................................................................................................... 12
6. Building Architectural and Structural Systems ............................................................................... 14
6.1. Foundations ............................................................................................................................... 14
6.2. Superstructure ........................................................................................................................... 14
6.3. Roofing ...................................................................................................................................... 14
6.4. Exterior Walls ............................................................................................................................ 15
6.5. Exterior and Interior Stairs ......................................................................................................... 16
6.6. Exterior Windows and Doors ..................................................................................................... 16
6.7. Patio, Terrace, and Balcony ...................................................................................................... 17
7. Building Mechanical and Plumbing Systems .................................................................................. 18
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC) ..................................................... 18
7.2. Building Plumbing and Domestic Hot Water ............................................................................. 19
7.3. Building Gas Distribution ........................................................................................................... 20
7.4. Building Electrical ...................................................................................................................... 20
7.5. Building Elevators and Conveying Systems .............................................................................. 20
7.6. Fire Protection and Security Systems ....................................................................................... 20
7.7. Life Support Systems ................................................................................................................ 21
8. Interior Spaces .................................................................................................................................... 22
8.1. Interior Finishes ......................................................................................................................... 22
8.2. Commercial Kitchen & Laundry Equipment .............................................................................. 23
9. Other Structures ................................................................................................................................. 24
10. Certification ......................................................................................................................................... 25
11. Appendices ......................................................................................................................................... 26
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
1
1. Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 301 East Hydraulic Avenue, Yorkville, Kendall, IL 60560
Year Constructed/Renovated: 2003
Current Occupants: Tenant - Yak Shack, Owner – City of Yorkville
Percent Utilization: 100%
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Retail
Site Area: 0.65 acres
Building Area: 1,224 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of
Spaces: 7 spaces in open lots
Building Construction: Conventional wood frame structure with raised floor
Roof Construction: Gabled roofs with metal roof finish
Exterior Finishes: Wood Siding
Heating, Ventilation & Air
Conditioning: Individual package heat pump units
Fire and Life/Safety: Extinguishers, exit signs, and emergency lights
Dates of Visit: May 23, 2017
On-Site Point of Contact (POC): Scott Sleezer
Assessment and Report
Prepared by: Paul Prusa
Reviewed by:
Al Diefert
Technical Report Reviewer For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Good HVAC Fair
Structure Good Plumbing Fair
Roof Good Electrical Fair
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
2
Systemic Condition Summary
Vertical Envelope Fair Elevators --
Interiors Fair Fire Poor
The following bullet points highlight the most significant short term and modernization recommendations:
Full replacement of gravel parking areas
Installation of a complete fire suppression and alarm system
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in fair overall condition.
According to property management personnel, the property has had a limited capital improvement expenditure program over the past
three years, primarily consisting of painting. Supporting documentation was not provided in support of these claims but some of the
work is evident.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
Fci Condition
Rating Definition Percentage
Value
Good In new or well-maintained condition, with no visual evidence
of wear, soiling or other deficiencies. 0% to 5%
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
3
Fci Condition
Rating Definition Percentage
Value
Fair Subjected to wear and soiling but is still in a serviceable and
functioning condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its
useful or serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal
is now necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 28.7% Poor
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 44.2% Poor
Current Replacement Value (CRV) 1,224 SF * 183.23 / SF = $224,282
Year 0 (Current Year) - Immediate Repairs (IR) $64,463
Years 1-10 – Replacement Reserves (RR) $99,325
Total Capital Needs $163,788
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Full replacement of gravel parking areas
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
1.3. Special Issues and Follow-Up Recommendations
As part of the FCA, a limited assessment of accessible areas of the building(s) was performed to determine the presence of fungal
growth, conditions conducive to fungal growth, and/or evidence of moisture. Property personnel were interviewed concerning any
known or suspected fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Sampling is not a part of this
assessment.
There are no visual indications of the presence of fungal growth, conditions conducive to fungal growth, or evidence of moisture in
representative readily accessible areas of the property.
1.4. Opinions of Probable Cost
Cost estimates are attached at the front of this report (following the cover page).
These estimates are based on Invoice or Bid Document/s provided either by the Owner/facility and construction costs developed by
construction resources such as R.S. Means and Marshall & Swift, EMG’s experience with past costs for similar properties, city cost
indexes, and assumptions regarding future economic conditions.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
4
Opinions of probable costs should only be construed as preliminary, order of magnitude budgets. Actual costs most probably will vary
from the consultant’s opinions of probable costs depending on such matters as type and design of suggested remedy, quality of
materials and installation, manufacturer and type of equipment or system selected, field conditions, whether a physical deficiency is
repaired or replaced in whole, phasing of the work (if applicable), quality of contractor, quality of project management exercised, market
conditions, and whether competitive pricing is solicited, etc. ASTM E2018-08 recognizes that certain opinions of probable costs cannot
be developed within the scope of this guide without further study. Opinions of probable cost for further study should be included in the
FCA.
1.4.1. Methodology
Based upon site observations, research, and judgment, along with referencing Expected Useful Life (EUL) tables from various industry
sources, EMG opines as to when a system or component will most probably necessitate replacement. Accurate historical replacement
records, if provided, are typically the best source of information. Exposure to the elements, initial quality and installation, extent of use,
the quality and amount of preventive maintenance exercised, etc., are all factors that impact the effective age of a system or
component. As a result, a system or component may have an effective age that is greater or less than its actual chronological age.
The Remaining Useful Life (RUL) of a component or system equals the EUL less its effective age. Projections of Remaining Useful Life
(RUL) are based on continued use of the Property similar to the reported past use. Significant changes in occupants and/or usage may
affect the service life of some systems or components.
Where quantities could not be derived from an actual take-off, lump sum costs or allowances are used. Estimated costs are based on
professional judgment and the probable or actual extent of the observed defect, inclusive of the cost to design, procure, construct and
manage the corrections.
1.4.2. Immediate Repairs
Immediate repairs are opinions of probable costs that require immediate action as a result of: (1) material existing or potential unsafe
conditions, (2) material building or fire code violations, or (3) conditions that, if not addressed, have the potential to result in, or
contribute to, critical element or system failure within one year or will most probably result in a significant escalation of its remedial cost.
1.4.3. Replacement Reserves
Replacement Reserves are for recurring probable expenditures, which are not classified as operation or maintenance expenses. The
replacement reserves should be budgeted for in advance on an annual basis. Replacement Reserves are reasonably predictable both
in terms of frequency and cost. However, Replacement Reserves may also include components or systems that have an
indeterminable life but, nonetheless, have a potential for failure within an estimated time period.
Replacement Reserves exclude systems or components that are estimated to expire after the reserve term and are not considered
material to the structural and mechanical integrity of the subject property. Furthermore, systems and components that are not deemed
to have a material effect on the use of the Property are also excluded. Costs that are caused by acts of God, accidents, or other
occurrences that are typically covered by insurance, rather than reserved for, are also excluded.
Replacement costs are solicited from ownership/property management, EMG’s discussions with service companies, manufacturers'
representatives, and previous experience in preparing such schedules for other similar facilities. Costs for work performed by the
ownership’s or property management’s maintenance staff are also considered.
EMG’s reserve methodology involves identification and quantification of those systems or components requiring capital reserve funds
within the assessment period. The assessment period is defined as the effective age plus the reserve term. Additional information
concerning system’s or component’s respective replacement costs (in today's dollars), typical expected useful lives, and remaining
useful lives were estimated so that a funding schedule could be prepared. The Replacement Reserves Schedule presupposes that all
required remedial work has been performed or that monies for remediation have been budgeted for items defined in the Immediate
Repair Cost Estimate.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
5
2. Purpose and Scope
2.1. Purpose
EMG was retained by the client to render an opinion as to the Property’s current general physical condition on the day of the site visit.
Based on the observations, interviews and document review outlined below, this report identifies significant deferred maintenance
issues, existing deficiencies, and material code violations of record at municipal offices, which affect the Property’s use. Opinions are
rendered as to its structural integrity, building system condition and the Property’s overall condition. The report also notes building
systems or components that have realized or exceeded their typical expected useful lives.
CONDITIONS:
The physical condition of building systems and related components are typically defined as being in one of five conditions: Excellent,
Good, Fair, Poor, Failed or a combination thereof. For the purposes of this report, the following definitions are used:
Excellent = New or very close to new; component or system typically has been installed within the past year, sound and
performing its function. Eventual repair or replacement will be required when the component or system either
reaches the end of its useful life or fails in service.
Good = Satisfactory as-is. Component or system is sound and performing its function, typically within the first third
of its lifecycle. However, it may show minor signs of normal wear and tear. Repair or replacement will be
required when the component or system either reaches the end of its useful life or fails in service.
Fair = Showing signs of wear and use but still satisfactory as-is, typically near the median of its estimated useful
life. Component or system is performing adequately at this time but may exhibit some signs of wear,
deferred maintenance, or evidence of previous repairs. Repair or replacement will be required due to the
component or system’s condition and/or its estimated remaining useful life.
Poor = Component or system is significantly aged, flawed, functioning intermittently or unreliably; displays obvious
signs of deferred maintenance; shows evidence of previous repair or workmanship not in compliance with
commonly accepted standards; has become obsolete; or exhibits an inherent deficiency. The present
condition could contribute to or cause the deterioration of contiguous elements or systems. Either full
component replacement is needed or repairs are required to restore to good condition, prevent premature
failure, and/or prolong useful life.
Failed
= Component or system has ceased functioning or performing as intended. Replacement, repair, or other
significant corrective action is recommended or required.
Not Applicable
= Assigning a condition does not apply or make logical sense, most commonly due to the item in question not
being present.
FORMAT OF THE BODY OF THE REPORT:
Throughout sections 5 through 9 of this report, each report section will typically contain three subsections organized in the following
sequence:
A descriptive table (and/or narrative), which identifies the components assessed, their condition, and other key data points.
A simple bulleted list of Anticipated Lifecycle Replacements, which lists components and assets typically in Excellent, Good, or Fair
condition at the time of the assessment but that will require replacement or some other attention once aged past their estimated
useful life. These listed components are typically included in the associated inventory database with costs identified and budgeted
beyond the first several years.
A bulleted cluster of Actions/Comments, which include more detailed narratives describing deficiencies, recommended repairs, and
short term replacements. The assets and components associated with these bullets are/were typically problematic and in Poor or
Failed condition at the time of the assessment, with corresponding costs included within the first few years.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
6
PLAN TYPES:
Each line item in the cost database is assigned a Plan Type, which is the primary reason or rationale for the recommended
replacement, repair, or other corrective action. This is the “why” part of the equation. A cost or line item may commonly have more
than one applicable Plan Type; however, only one Plan Type will be assigned based on the “best” fit, typically the one with the greatest
significance. The following Plan Types are listed in general weighted order of importance:
Safety = An observed or reported unsafe condition that if left unaddressed could result in an injury; a system or
component that presents a potential liability risk.
Performance/Integrity = Component or system has failed, is almost failing, performs unreliably, does not perform as intended,
and/or poses a risk to overall system stability.
Accessibility = Does not meet ADA, UFAS, and/or other handicap accessibility requirements.
Environmental = Improvements to air or water quality, including removal of hazardous materials from the building or
site.
Modernization/Adaptation
= Conditions, systems, or spaces that need to be upgraded in appearance or function to meet current
standards, facility usage, or client/occupant needs.
Lifecycle/Renewal
= Any component or system in which future repair or replacement is anticipated beyond the next several
years and/or is of minimal substantial early-term consequence.
2.2. Scope
The standard scope of the Facility Condition Assessment includes the following:
Visit the Property to evaluate the general condition of the building and site improvements, review available construction documents in
order to familiarize ourselves with, and be able to comment on, the in-place construction systems, life safety, mechanical, electrical,
and plumbing systems, and the general built environment.
Identify those components that are exhibiting deferred maintenance issues and provide cost estimates for Immediate Costs and
Replacement Reserves based on observed conditions, maintenance history and industry standard useful life estimates. This will
include the review of documented capital improvements completed within the last five-year period and work currently contracted for, if
applicable.
Provide a full description of the Property with descriptions of in-place systems and commentary on observed conditions.
Provide a general statement of the subject Property’s compliance to Title III of the Americans with Disabilities Act. This will not
constitute a full ADA survey, but will help identify exposure to issues and the need for further review.
Perform a limited assessment of accessible areas of the building(s) for the presence of fungal growth, conditions conducive to fungal
growth, and/or evidence of moisture. EMG will also interview Project personnel regarding the presence of any known or suspected
fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Potentially affected areas will be photographed.
Sampling will not be considered in routine assessments.
List the current utility service providers.
Review maintenance records and procedures with the in-place maintenance personnel.
Observe a representative sample of the interior spaces/units, including vacant spaces/units, in order to gain a clear understanding of
the property’s overall condition. Other areas to be observed include the exterior of the property, the roofs, interior common areas,
and the significant mechanical, electrical and elevator equipment rooms.
Provide an Executive Summary at the beginning of this report.
2.3. Personnel Interviewed
The building engineer was interviewed for specific information relating to the physical property, available maintenance procedures,
historical performance of key building systems and components, available drawings and other documentation. The following personnel
from the facility and government agencies were interviewed in the process of conducting the FCA:
Name and Title Organization Phone Number
Scott Sleezer City of Yorkville – Parks and Recreation 630.878.7291
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
7
The FCA was performed with the assistance of Scott Sleezer, City of Yorkville - Parks and Recreation, the onsite Point of Contact
(POC), who was cooperative and provided information that appeared to be accurate based upon subsequent site observations. The
onsite contact is completely knowledgeable about the subject property and answered most questions posed during the interview
process. The POC’s management involvement at the property has been for the past 26 years.
2.4. Documentation Reviewed
Prior to the FCA, relevant documentation was requested that could aid in the knowledge of the subject property’s physical
improvements, extent and type of use, and/or assist in identifying material discrepancies between reported information and observed
conditions. The review of submitted documents does not include comment on the accuracy of such documents or their preparation,
methodology, or protocol. The Documentation Request Form is provided in Appendix E.
Although Appendix E provides a summary of the documents requested or obtained, the following list provides more specific details
about some of the documents that were reviewed or obtained during the site visit.
No documents provided.
2.5. Pre-Survey Questionnaire
A Pre-Survey Questionnaire was sent to the POC prior to the site visit and was not returned. The questionnaire is included in Appendix
E.
2.6. Weather Conditions
May 23, 2017: Overcast and rain, with temperatures in the 70s (°F) and light winds.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
8
3. Accessibility and Property Research
3.1. ADA Accessibility
Generally, Title III of the Americans with Disabilities Act (ADA) prohibits discrimination by entities to access and use of “areas of public
accommodations” and “commercial facilities” on the basis of disability. Regardless of its age, these areas and facilities must be
maintained and operated to comply with the Americans with Disabilities Act Accessibility Guidelines (ADAAG).
Buildings completed and occupied after January 26, 1992 are required to comply fully with the ADAAG. Existing facilities constructed
prior to this date are held to the lesser standard of compliance to the extent allowed by structural feasibility and the financial resources
available. As an alternative, a reasonable accommodation pertaining to the deficiency must be made.
During the FCA, a limited visual observation for ADA accessibility compliance was conducted. The scope of the visual observation was
limited to those areas set forth in EMG’s Abbreviated Accessibility Checklist provided in Appendix D of this report. It is understood by
the Client that the limited observations described herein does not comprise a full ADA Compliance Survey, and that such a survey is
beyond the scope of EMG’s undertaking. Only a representative sample of areas was observed and, other than as shown on the
Abbreviated Accessibility Checklist, actual measurements were not taken to verify compliance.
At a retail property, the areas considered as a public accommodation besides the site itself and parking, are the exterior accessible
route, the interior accessible route up to the tenant lease lines and the interior common areas, including the common area restrooms.
The facility does not appear to be accessible with Title III of the Americans with Disabilities Act. Elements as defined by the ADAAG
that are not accessible as stated within the priorities of Title III, are as follows:
Parking
Adequate number of designated parking stalls and signage for vans are not provided.
Restrooms
Wrap drain pipes below lavatory with insulation; protect against contact with hot, sharp, or abrasive surfaces.
A full ADA Compliance Survey may reveal additional aspects of the property that are not in compliance.
Corrections of these conditions should be addressed from a liability standpoint, but are not necessarily code violations. The Americans
with Disabilities Act Accessibility Guidelines concern civil rights issues as they pertain to the disabled and are not a construction code,
although many local jurisdictions have adopted the Guidelines as such. The cost to address the achievable item noted above is
included in the cost tables.
3.2. Municipal Information, Flood Zone and Seismic Zone
Not applicable.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
9
4. Existing Building Assessment
4.1. Unit or Space Types
All 1,224 square feet of the building are occupied by a single occupant, Yak Shack. The building is owned and maintained by the City
of Yorkville. The spaces are mostly retail space, supporting restroom, and other utility spaces.
4.2. Inaccessible Areas or Key Spaces Not Observed
The interior spaces were observed in order to gain a clear understanding of the property’s overall condition. Other areas accessed
included the site within the property boundaries, exterior of the property and the roof. All areas of the property were available for
observation during the site visit.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
10
5. Site Improvements
5.1. Utilities
The following table identifies the utility suppliers and the condition and adequacy of the services.
Site Utilities
Utility Supplier Condition and Adequacy
Sanitary sewer City of Yorkville Good
Storm sewer City of Yorkville Good
Domestic water City of Yorkville Good
Electric service Commonwealth Edison Good
Natural gas service Nicor Gas Good
Actions/Comments:
According to the POC, the utilities provided are adequate for the property. There are no unique, onsite utility systems such as
emergency electrical generators, septic systems, water or waste water treatment plants, or propane gas tanks.
5.2. Parking, Paving, and Sidewalks
Item Description
Main Ingress and Egress Hydraulic Avenue
Access from West
Additional Entrances --
Additional Access from --
Paving and Flatwork
Item Material Last Work Done Condition
Entrance Driveway Apron Gravel 2003 Fair
Parking Lot Asphalt 2003 Fair
Drive Aisles Gravel 2003 Fair
Service Aisles None 2003 --
Sidewalks Concrete 2003 Good
Curbs None 2003 --
Site Stairs Cast-in-place concrete 2003 Good
Pedestrian Ramps Cast-in-place concrete
Wood
2003
2003
Good
Fair
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
11
Parking Count
Open Lot Carport Private Garage Subterranean
Garage
Freestanding Parking
Structure
7 -- -- -- --
Total Number of ADA Compliant Spaces 1
Number of ADA Compliant Spaces for Vans 0
Total Parking Spaces 7
Parking Ratio (Spaces/Apartments) --
Method of Obtaining Parking Count Physical count
Exterior Stairs
Location Material Handrails Condition
Front entrance Concrete stairs Metal Good
Anticipated Lifecycle Replacements:
Asphalt seal coating
Asphalt pavement
Concrete pavement
Pedestrian ramps
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
5.3. Drainage Systems and Erosion Control
Drainage System and Erosion Control
System Exists At Site Condition
Surface Flow ☒ Good
Inlets ☐ --
Swales ☐ --
Detention pond ☐ --
Lagoons ☐ --
Ponds ☐ --
Underground Piping ☐ --
Pits ☐ --
Municipal System ☐ --
Dry Well ☐ --
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
12
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
There is no evidence of storm water runoff from adjacent properties. The storm water system appears to provide adequate runoff
capacity. There is no evidence of major ponding or erosion.
5.4. Topography and Landscaping
Item Description
Site Topography Slopes toward adjacent river.
Landscaping
Trees Grass Flower
Beds Planters
Drought
Tolerant
Plants
Decorative
Stone None
☒ ☒ ☐ ☐ ☒ ☐ ☐
Landscaping
Condition Good
Irrigation
Automatic
Underground Drip Hand Watering None
☐ ☐ ☐ ☒
Irrigation Condition Good
Retaining Walls
Type Location Condition
None -- --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The topography and adjacent uses do not appear to present conditions detrimental to the property. There are no significant areas of
erosion.
5.5. General Site Improvements
Property Signage
Property Signage Building mounted
Street Address Displayed? Yes
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
13
Site and Building Lighting
Site Lighting
None Pole Mounted Bollard Lights Ground
Mounted
Parking Lot
Pole Type
☐ ☒ ☐ ☐ ☐
Fair
Building Lighting
None Wall Mounted Recessed Soffit
☐ ☒ ☐
Fair
Site Fencing
Type Location Condition
None -- --
REFUSE DISPOSAL
Refuse Disposal Individual garbage bins
Dumpster Locations Mounting Enclosure Contracted? Condition
None None None Yes --
Other Site Amenities
Description Location Condition
Playground Equipment None -- --
Tennis Courts None -- --
Basketball Court None -- --
Swimming Pool None -- --
Anticipated Lifecycle Replacements:
Exterior lighting
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
14
6. Building Architectural and Structural Systems
6.1. Foundations
Building Foundation
Item Description Condition
Foundation Concrete foundation walls Good
Basement and Crawl Space None --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The foundation systems are concealed. There are no significant signs of settlement, deflection, or movement.
6.2. Superstructure
Building Superstructure
Item Description Condition
Framing / Load-Bearing Walls Conventional wood/metal studs Good
Ground Floor Raised wood Good
Upper Floor Framing -- --
Upper Floor Decking -- --
Roof Framing Wood joists, purlins, rafters Good
Roof Decking Plywood or OSB Good
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The superstructure is concealed. Walls and floors appear to be plumb, level, and stable. There are no significant signs of deflection
or movement.
6.3. Roofing
Primary Roof
Type / Geometry Gable Roof Finish Metal
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
15
Primary Roof
Maintenance Outside Contractor Roof Age 14 Yrs
Flashing Sheet metal Warranties Unknown
Parapet Copings None Roof Drains Gutters and downspouts
Fascia Metal Panel Insulation Fiberglass batts
Soffits Concealed Soffits Skylights No
Attics Wood joists with plywood
sheathing Ponding No
Ventilation Source-1 Soffit Vents Leaks Observed No
Ventilation Source-2 -- Roof Condition Good
Anticipated Lifecycle Replacements:
Metal roof finish
Roof flashings (included as part of overall replacement)
Actions/Comments:
The roof finishes were reportedly installed in 2003. Information regarding roof warranties or bonds was not available. The roofs are
maintained by an outside contractor.
According to the POC, there are no active roof leaks. There is no evidence of active roof leaks.
There is no evidence of roof deck or insulation deterioration. The roof substrate and insulation should be inspected during any future
roof repair or replacement work.
Roof drainage appears to be adequate. Clearing and minor repair of drain system components should be performed regularly as part
of the property management’s routine maintenance and operations program.
The attics are not accessible and it could not be determined if there is moisture, water intrusion, or excessive daylight in the attics.
6.4. Exterior Walls
Building Exterior Walls
Type Location Condition
Primary Finish Wood siding Fair
Secondary Finish -- --
Accented with Wood shakes Fair
Soffits Concealed Good
Building sealants (caulking) are located between dissimilar materials, at joints, and around window and door openings.
Anticipated Lifecycle Replacements:
Exterior paint
Wood siding
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
16
Wood trim (included with siding)
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance, including patching repairs, graffiti removal,
and re-caulking, is highly recommended. Future lifecycle replacements of the components listed above will be required.
6.5. Exterior and Interior Stairs
Building Exterior and Interior Stairs
Type Description Riser Handrail Balusters Condition
Building Exterior Stairs Concrete stairs Closed Metal Metal Fair
Building Interior Stairs None -- -- -- --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
6.6. Exterior Windows and Doors
Building Windows
Window Framing Glazing Location Window
Screen Condition
Vinyl framed, operable Double glaze Front elevation ☐ Fair
Building Doors
Main Entrance Doors Door Type Condition
Fully glazed, metal framed Fair
Secondary Entrance Doors Full glazed, solid core wood Fair
Service Doors -- --
Overhead Doors -- --
Anticipated Lifecycle Replacements:
Windows
Exterior glazed doors
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
17
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
6.7. Patio, Terrace, and Balcony
Not applicable. There are no patios, terraces, or balconies.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
18
7. Building Mechanical and Plumbing Systems
See the Mechanical Equipment List in the Appendices for the quantity, manufacturer’s name, model number, capacity and year of
manufacturer of the major mechanical equipment, if available.
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC)
Individual Units
Primary Components Heat Pump
Cooling (if separate from above) performed via components above
Quantity and Capacity Ranges 2 units at 2.5 tons each
Total Heating or Cooling Capacity 5 tons
Heating Fuel Electric
Location of Equipment Exterior walls
Space Served by System Entire building
Age Ranges All units dated 2006
Primary Component Condition Fair
Controls and Ventilation
HVAC Control System Individual non-programmable thermostats/controls
HVAC Control System Condition Fair
Building Ventilation Restroom fan
Ventilation System Condition Fair
Anticipated Lifecycle Replacements:
Heat pump
Actions/Comments:
The HVAC systems are maintained by the in-house maintenance staff. Records of the installation, maintenance, upgrades, and
replacement of the HVAC equipment at the property have been maintained since the property was first occupied.
Approximately 100 percent of the HVAC equipment is original. The property is relatively new and has not required any major HVAC
equipment replacements.
The HVAC equipment appears to be functioning adequately overall. The engineering staff was interviewed about the historical and
recent performance of the equipment and systems. No chronic problems were reported and an overall sense of satisfaction with the
systems was conveyed. However, due to the inevitable failure of parts and components over time, some of the equipment will
require replacement. A budgetary cost for this work is included.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
19
7.2. Building Plumbing and Domestic Hot Water
Building Plumbing System
Type Description Condition
Water Supply Piping Copper Good
Waste/Sewer Piping PVC Good
Vent Piping PVC Good
Water Meter Location Utility Closet
Domestic Water Heaters or Boilers
Components Water Heater
Fuel Electric
Quantity and Input Capacity 1 units at 9.6 kW each
Storage Capacity --
Boiler or Water Heater Condition Fair
Supplementary Storage Tanks? No
Storage Tank Quantity & Volume --
Quantity of Storage Tanks --
Storage Tank Condition --
Domestic Hot Water Circulation Pumps (3 HP and over) No
Adequacy of Hot Water Adequate
Adequacy of Water Pressure Adequate
Plumbing Fixtures
Water Closets Residential grade
Toilet (Water Closet) Flush Rating 1.6 GPF
Common Area Faucet Nominal Flow Rate 2.0 GPM
Condition Fair
Anticipated Lifecycle Replacements:
Water heater
Toilet
Lavatory
Actions/Comments:
The plumbing systems appear to be well maintained and functioning adequately. The water pressure appears to be sufficient. No
significant repair actions or short term replacement costs are required. Routine and periodic maintenance is recommended. Future
lifecycle replacements of the components or systems listed above will be required.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
20
7.3. Building Gas Distribution
Not applicable. The property is not supplied with natural gas.
7.4. Building Electrical
Building Electrical Systems
Electrical Lines Overhead Transformer Pole-mounted
Main Service Size 200 Amps Volts 120/240 Volt, single-phase
Meter Location Left Elevation Branch Wiring Copper
Conduit Metallic Step-Down
Transformers? No
Security / Surveillance
System? No Building Intercom
System? No
Lighting Fixtures T-8
Main Distribution Condition Fair
Secondary Panel and
Transformer Condition --
Lighting Condition Fair
Anticipated Lifecycle Replacements:
Circuit breaker panels
Interior light fixtures
Actions/Comments:
The onsite electrical systems up to the meters are owned and maintained by the respective utility company.
The electrical service and capacity appear to be adequate for the property’s demands.
The panels are original 2003 components. The electrical service is reportedly adequate for the facility’s needs. However, due to the
age of the panels and increasing difficulty of obtaining replacement parts over time, lifecycle replacements are recommended per
above.
7.5. Building Elevators and Conveying Systems
Not applicable. There are no elevators or conveying systems.
7.6. Fire Protection and Security Systems
Item Description
Type None
Fire Alarm System Central Alarm Panel ☐ Battery-Operated Smoke
Detectors ☐ Alarm Horns ☐
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
21
Item Description
Type None
Annunciator Panels ☐ Hard-Wired Smoke
Detectors ☐ Strobe Light Alarms ☐
Pull Stations ☐ Emergency Battery-Pack
Lighting ☒ Illuminated EXIT Signs ☒
Alarm System
Condition Fair
Sprinkler System
None ☒ Standpipes ☐ Backflow Preventer ☐
Hose Cabinets ☐ Fire Pumps ☐ Siamese Connections ☐
Suppression
Condition --
Central Alarm Panel
System
Location of Alarm Panel Installation Date of Alarm Panel
-- --
Fire Extinguishers
Last Service Date Servicing Current?
May 2017 Yes
Hydrant Location Hydraulic Avenue
Siamese Location --
Special Systems Kitchen Suppression System ☐Computer Room Suppression System ☐
Anticipated Lifecycle Replacements:
Alarm devices and system
Sprinkler heads
Actions/Comments:
The building is not protected by fire suppression. Due to its construction date, the facility is most likely “grandfathered” by code and
the installation of fire sprinklers not required until major renovations are performed. Regardless of when or if installation of facility-
wide fire suppression is required by the governing municipality, EMG recommends a retrofit be performed. A budgetary cost is
included.
The fire alarm system is not up to current standards. There is a lack of strobes, audio alarms, pull stations, system not fully
addressable, and there is no city tie despite the building being unoccupied a large portion of the winter. A facility-wide fire alarm
modernization is recommended. A budgetary cost is included.
7.7. Life Support Systems
Not applicable.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
22
8. Interior Spaces
8.1. Interior Finishes
The facility is used a kayak rental retail shop for the Yak Shack.
The most significant interior spaces include retail space and an office. Supporting areas include hallway, restroom, and utility closet.
The following table generally describes the locations and typical conditions of the interior finishes within the facility:
Typical Floor Finishes
Floor Finish Locations General Condition
Hardwood Retail space, restroom Fair
Carpet Office, retail space Fair
Typical Wall Finishes
Wall Finish Locations General Condition
Painted drywall Office, retail space, restroom Fair
Typical Ceiling Finishes
Ceiling Finish Locations General Condition
Painted drywall Office, retail space, restroom Fair
Interior Doors
Item Type Condition
Interior Doors Hollow core, fully-glazed wood Fair
Door Framing Wood Fair
Fire Doors No --
Anticipated Lifecycle Replacements:
Carpet
Wood strip flooring
Interior paint
Interior doors
Actions/Comments:
It appears that the interior finishes are original.
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
23
8.2. Commercial Kitchen & Laundry Equipment
Not applicable.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
24
9. Other Structures
A storage shed is located at the rear of the main building. The storage shed is a pre-manufactured wood structure set on a wood
beams.
Anticipated Lifecycle Replacements:
Storage shed
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
25
10. Certification
City of Yorkville retained EMG to perform this Facility Condition Assessment in connection with its continued operation of Riverfront
Park Building (Yak Shack), 301 E Hydraulic, Yorkville, Illinois, the “Property”. It is our understanding that the primary interest of City of
Yorkville is to locate and evaluate materials and building system defects that might significantly affect the value of the property and to
determine if the present Property has conditions that will have a significant impact on its continued operations.
The conclusions and recommendations presented in this report are based on the brief review of the plans and records made available
to our Project Manager during the site visit, interviews of available property management personnel and maintenance contractors
familiar with the Property, appropriate inquiry of municipal authorities, our Project Manager’s walk-through observations during the site
visit, and our experience with similar properties.
No testing, exploratory probing, dismantling or operating of equipment or in depth studies were performed unless specifically required
under Section 2 of this report. This assessment did not include engineering calculations to determine the adequacy of the Property’s
original design or existing systems. Although walk-through observations were performed, not all areas were observed (See Section 4.2
for areas observed). There may be defects in the Property, which were in areas not observed or readily accessible, may not have been
visible, or were not disclosed by management personnel when questioned. The report describes property conditions at the time that
the observations and research were conducted.
This report has been prepared on behalf of and exclusively for the use of City of Yorkville for the purpose stated within Section 2 of this
report. The report, or any excerpt thereof, shall not be used by any party other than City of Yorkville or for any other purpose than that
specifically stated in our agreement or within Section 2 of this report without the express written consent of EMG.
Any reuse or distribution of this report without such consent shall be at City of Yorkville and the recipient’s sole risk, without liability to
EMG.
Prepared by: Paul Prusa P.E., LEED AP
Project Manager
Reviewed by:
Al Diefert
Technical Report Reviewer For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
26
11. Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: EMG Accessibility Checklist
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
Appendix A:
Photographic Record
RIVER FRONT PARK BUILDING
301 HYDRAULIC
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-013.322
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: RIGHT ELEVATION
#3: LEFT ELEVATION
#4: REAR ELEVATION
#5: ADA, MISSING LAVATORY PIPE
WRAPS
#6: PARKING LOT, ASPHALT
PAVEMENT
RIVER FRONT PARK BUILDING
301 HYDRAULIC
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-013.322
www.EMGcorp.com p 800.733.0660
#7: PARKING LOT, GRAVEL
#8: SIDEWALK, CONCRETE
#9: EXTERIOR RAMP, WOOD
#10: EXTERIOR STAIRS & RAMPS,
CONCRETE
#11: POLE LIGHT, EXTERIOR
#12: ROOF, METAL
RIVER FRONT PARK BUILDING
301 HYDRAULIC
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-013.322
www.EMGcorp.com p 800.733.0660
#13: EXTERIOR WALL, PAINTED
SURFACE
#14: EXTERIOR WALL, WOOD
CLAPBOARD
#15: EXTERIOR WALL, DAMAGED
CLAPBOARD
#16: EXTERIOR STAIR/RAMP RAILS,
WOOD
#17: EXTERIOR STAIR/RAMP RAILS,
METAL
#18: EXTERIOR STAIRS, CONCRETE
RIVER FRONT PARK BUILDING
301 HYDRAULIC
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-013.322
www.EMGcorp.com p 800.733.0660
#19: EXTERIOR DOOR, FULLY-
GLAZED ALUMINUM-FRAMED
#20: EXTERIOR DOOR, FULLY-
GLAZED WOOD
#21: WINDOW, VINYL-CLAD
DOUBLE-GLAZED
#22: HEAT PUMP
#23: LAVATORY
#24: TOILET
RIVER FRONT PARK BUILDING
301 HYDRAULIC
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-013.322
www.EMGcorp.com p 800.733.0660
#25: WATER HEATER, INSTANT HOT,
ELECTRIC
#26: LOAD CENTER, 100 AMP
#27: INCANDESCENT LIGHTING
FIXTURE
#28: LIGHTING INTERIOR
#29: FIRE EXTINGUISHER
#30: EMERGENCY/EXIT COMBO
RIVER FRONT PARK BUILDING
301 HYDRAULIC
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-013.322
www.EMGcorp.com p 800.733.0660
#31: INTERIOR FLOOR WOOD STRIP
#32: CARPET
#33: INTERIOR WALL FINISH
#34: INTERIOR CEILING FINISH
#35: INTERIOR DOOR, WOOD
HOLLOW-CORE
#36: INTERIOR DOOR, FULLY-
GLAZED WOOD-FRAMED
RIVER FRONT PARK BUILDING
301 HYDRAULIC
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-013.322
www.EMGcorp.com p 800.733.0660
#37: INTERIOR WINDOW
#38: PREFABRICATED BUILDING
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
Appendix B:
Site Plan
Site Plan
Project Name:
River Front Park Building
Project Number:
122700.17R000-013.322
Source:
Google Maps
On-Site Date:
May 23, 2017
RIVERFRONT PARK BUILDING – YAK SHACK EMG PROJECT NO.: 122700.17R000-013.322
Appendix C:
EMG Accessibility Checklist
Page 1 of 4
Date Completed: June 13, 2017
Property Name: River Front Park Building
EMG Project Number: 122700.17R000-013.322
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Stepping Stone Park
3152 Grande Trail
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-016.366 June 20, 2017 May 25, 2017
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
FACILITY CONDITION ASSESSMENT
STEPPING STONE PARK EMG PROJECT NO.: 122700.17R000-016.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
STEPPING STONE PARK EMG PROJECT NO.: 122700.17R000-016.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: Stepping Stone Park, Yorkville, Kendall, Illinois 60560
Year Constructed/Renovated: 2007
Current Occupants: City of Yorkville Parks Department
Management Point of Contact:
City of Yorkville/Facilities, Erin Willrett, Manager
630.553.8574 phone
ewillrett@Yorkville.il.us Email
Property Type: City Park, shelter, play lot and grounds
Site Area: 5.0 acres
Building Area: 500 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: 0 spaces in open lots, street parking only.
Building Construction: Steel frame with metal roof. No exterior walls.
Roof Construction: Gabled roof, sheet metal
Exterior Finishes: Metal Siding
Heating, Ventilation and Air Conditioning: None
Fire and Life/Safety: Hydrants
Dates of Visit: May 25, 2017
On-Site Point of Contact (POC): Tony Houle
Assessment and Report Prepared by: George Wozniczka
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Good HVAC --
Structure Good Plumbing --
Roof Good Electrical --
Vertical Envelope -- Elevators --
Interiors -- Fire --
STEPPING STONE PARK EMG PROJECT NO.: 122700.17R000-016.366
2
www.EMGcorp.com p 800.733.0660
The following bullet points highlight the most significant short term and modernization recommendations:
Wood chips – mulch
Landscaping
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied in 2007and is in good overall condition.
According to property management personnel, the property has had an active capital improvement expenditure program over the past
three years, primarily consisting of asphalt pavement seal coating. Supporting documentation was not provided in support of these
claims but some of the work is evident.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
STEPPING STONE PARK EMG PROJECT NO.: 122700.17R000-016.366
3
www.EMGcorp.com p 800.733.0660
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.0% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 5.0% Good
Current Replacement Value (CRV) 500 SF * $183.24 / SF = $91,618.56
Year 0 (Current Year) - Immediate Repairs (IR) $0.00
Years 1-10 – Replacement Reserves (RR) $4,597
Total Capital Needs $4,597
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Landscaping in deteriorated areas
Add mulch to play area
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
STEPPING STONE PARK EMG PROJECT NO.: 122700.17R000-016.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: Pre-Survey Questionnaire
Appendix D: ADA Checklist
STEPPING STONE PARK EMG PROJECT NO.: 122700.17R000-016.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
STEPPING STONE PARK
3152 GRANDE TRAIL
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-016.366
www.EMGcorp.com p 800.733.0660
PHOTO
#1:
PARK SIGN AND PARK PHOTO
#2:
FRONT ELEVATION VIEW – AS SEEN
FROM THE STREET – FROM NORTH
PHOTO
#3:
EASTERN ELEVATION OF PARK PHOTO
#4:
SOUTHERN ELEVATION OF PARK
PHOTO
#5:
WESTERN ELEVATION OF PARK PHOTO
#6:
CONCRETE CURB
STEPPING STONE PARK
3152 GRANDE TRAIL
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-016.366
www.EMGcorp.com p 800.733.0660
PHOTO
#7:
CHIP MULCH AND CONCRETE CURB PHOTO
#8:
CLIMBING APPARATUS
PHOTO
#9:
STEEL STAIRS PHOTO
#10:
PLASTIC SLIDES
PHOTO
#11:
CONCRETE RETAINING WALL PHOTO
#12:
SWINGS
STEPPING STONE PARK
3152 GRANDE TRAIL
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-016.366
www.EMGcorp.com p 800.733.0660
PHOTO
#13:
MULCH UNDER SWING PHOTO
#14:
ASPHALT AND CONCRETE
WALKWAY
PHOTO
#15:
FRONT ELEVATIONS - SHELTER PHOTO
#16:
STEEL ROOF OF SHELTER
PHOTO
#17:
CEILING OF SHELTER PHOTO
#18:
PAINTED STEEL WALL OF SHELTER
STEPPING STONE PARK
3152 GRANDE TRAIL
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-016.366
www.EMGcorp.com p 800.733.0660
PHOTO
#19:
PARK BENCH PHOTO
#20:
CONCRETE FLOOR AT SHELTER
PHOTO
#21:
DRAINAGE AND LANDSCAPING PHOTO
#22:
LANDSCAPING
PHOTO
#23:
SOCCER GOAL PHOTO
#24:
PLAY AREA
STEPPING STONE PARK
3152 GRANDE TRAIL
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-016.366
www.EMGcorp.com p 800.733.0660
PHOTO
#25:
PAINTED STEEL POST PHOTO
#26:
WASTE COLLECTION
PHOTO
#27:
HYDRANT PHOTO
#28:
INSTRUCTION SIGN
PHOTO
#29:
CRACKED CONCRETE PHOTO
#30:
MULCH AND CLIMBING APPARATUS
STEPPING STONE PARK EMG PROJECT NO.: 122700.17R000-016.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name
Stepping Stone Park
Project Number:
122700.17R000-016.366
Source:
Google Map
On-Site Date:
May 25, 2017
STEPPING STONE PARK EMG PROJECT NO.: 122700.17R000-016.366
www.EMGcorp.com p 800.733.0660
Appendix C:
Pre-Survey Questionnaire
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
YorlThis questionnaire must be completed by the property owner, the owner's designated representative, or someone knowledgeable
about the subject property. If the form is not completed, EMG’s Project Manager will require additional time during the on-site visit
with such a knowledgeable person in order to complete the questionnaire. During the site visit, EMG's Field Observer may ask for
details associated with selected questions. This questionnaire will be utilized as an exhibit in EMG's final report.
Name of Institution: Stepping Stone Park
Name of Building: Stepping Stone Park Building #: Shelter
Name of person completing questionnaire: Tony Houle
Length of Association With the Property: 10 years, since constructed Phone Number: 630-885-3569
Site Information
Year of Construction? 2007
No. of Stories? 1
Total Site Area? 5 acres
Total Building Area? 500 Sqft
Inspections Date of Last
Inspection List of Any Outstanding Repairs Required
1. Elevators N/A
2. HVAC Mechanical, Electric,
Plumbing? N/A
3. Life-Safety/Fire? N/A
4. Roofs? Annually
Key Questions Response
Major Capital Improvements in Last 3 yrs. None
Planned Capital Expenditure For Next Year? None
Age of the Roof? 2007
What bldg. Systems Are Responsibilities of
Tenants? (HVAC/Roof/Interior/Exterior/Paving) All
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
ZONING, BUILDING DESIGN & LIFE SAFETY ISSUES
1 Are there any unresolved building,
fire, or zoning code issues? x
2 Is there any pending litigation
concerning the property? x
3 Are there any other significant
issues/hazards with the property? x
4 Are there any unresolved
construction defects at the
property?
x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
ZONING, BUILDING DESIGN & LIFE SAFETY ISSUES
5 Has any part of the property ever
contained visible suspect mold
growth?
x
6 Is there a mold Operations and
Maintenance Plan? x
7 Are there any recalled fire sprinkler
heads (Star, GEM, Central, and
Omega)?
x
8 Have there been indoor air quality
or mold related complaints from
tenants?
x
GENERAL SITE
9 Are there any problems with
erosion, storm water drainage or
areas of paving that do not drain?
x
10 Are there any problems with the
landscape irrigation systems? x
BUILDING STRUCTURE
11 Are there any problems with
foundations or structures? x
12 Is there any water infiltration in
basements or crawl spaces? x
13 Has a termite/wood boring insect
inspection been performed within
the last year?
x
BUILDING ENVELOPE
14 Are there any wall, or window
leaks? x
15 Are there any roof leaks? x
16 Is the roofing covered by a
warranty or bond? x
17 Are there any poorly insulated
areas? x
18 Is Fire Retardant Treated (FRT)
plywood used? x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
BUILDING ENVELOPE
19 Is exterior insulation and finish
system (EIFS) or a synthetic
stucco finish used?
x
BUILDING HVAC AND ELECTRICAL
20 Are there any leaks or pressure
problems with natural gas service? x
21 Does any part of the electrical
system use aluminum wiring? x
22 Do Residential units have a less
than 60-Amp service? x
23 Do Commercial units have less
than 200-Amp service? x
24 Are there any problems with the
utilities, such as inadequate
capacities?
x
ADA
25 Has the management previously
completed an ADA review? x After construction in 2007
26 Have any ADA improvements
been made to the property? x
27 Does a Barrier Removal Plan exist
for the property? x
28 Has the Barrier Removal Plan
been approved by an arms-length
third party?
x
29 Has building ownership or
management received any ADA
related complaints?
x
30 Does elevator equipment require
upgrades to meet ADA standards? x
PLUMBING
31 Is the property served by private
water well? x
32 Is the property served by a private
septic system or other waste
treatment systems?
x
33 Is polybutylene piping used? x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
PLUMBING
34 Are there any plumbing leaks or
water pressure problems? x
Additional Issues or Concerns That EMG Should Know About?
1. The property is in good condition
2.
3.
Items Provided to EMG Auditors
Yes No N/A Additional Comments?
Access to All Mechanical Spaces
Access to Roof/Attic Space
Access to Building As-Built Drawings Available
Site plan with bldg., roads, parking and other features
Contact Details for Mech, Elevator, Roof, Fire
Contractors:
List of Commercial Tenants in the property
Previous reports pertaining to the physical condition of
property.
ADA survey and status of improvements implemented.
Current / pending litigation related to property
condition.
Any brochures or marketing information.
________________________________ ___________
Signature of person Interviewed or completing form Date
STEPPING STONE PARK EMG PROJECT NO.: 122700.17R000-016.366
www.EMGcorp.com p 800.733.0660
Appendix D:
ADA Checklist
Page 1 of 4
Date Completed: May 25, 2017
Property Name: Stepping Stone Park
EMG Project Number: 122700.17R000-016.366
Building History Yes No Unk Comments
1 Has an ADA survey previously been
completed for this property? After 2007 construction
2 Have any ADA improvements been made
to the property?
3 Does a Transition Plan / Barrier Removal
Plan exist for the property?
4 Has building ownership or management
received any ADA related complaints that
have not been resolved?
5 Is any litigation pending related to ADA
issues?
Parking Yes No NA Comments
1 Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
Street parking only
2 Are there sufficient van-accessible parking
spaces available?
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
5 Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
6 If required does signage exist directing you
to accessible parking and an accessible
building entrance?
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less)
2
Are ramps that appear longer than 6 ft
complete with railings on both sides?
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches?
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door?
2
If the main entrance is inaccessible, are
there alternate accessible entrances?
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)?
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage?
3
Is there a path of travel that does not
require the use of stairs?
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives?
2
Are there visual and audible signals inside
cars indicating floor change?
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons?
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door?
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)?
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication?
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route?
2
Are pull handles push/pull or lever type?
3
Are there audible and visual fire alarm
devices in the toilet rooms?
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)?
Toilet Rooms (cont.) Yes No NA Comments
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)?
6
In unisex toilet rooms, are there safety
alarms with pull cords?
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)?
8
Are grab bars provided in toilet stalls?
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)?
10
Are sink handles operable with one hand
without grasping, pinching or twisting?
11
Are exposed pipes under sink sufficiently
insulated against contact?
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section.
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards. Play area was designed per ADA guidelines
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
*Based on visual observation only. The slope was not confirmed through measurements.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Stevens Bridge Park Concession
3651 Kennedy Road
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-017.366 September 13, 2017 May 25, 2017
FACILITY CONDITION ASSESSMENT
Immediate Repairs Report
Stevens Bridge Park Conce
9/13/2017
Location Name EMG Renamed Item NumberID Cost Description QuantityUnit Unit Cost Subtotal Deficiency Repair Estimate *
Stevens Bridge Park Conce 3.1 617003 ADA, Parking, Designated Stall with Pavement Markings & Signage (Van), Install 1 EA $1,391.50 $1,392 $1,392
Immediate Repairs Total $1,392
* Location Factor included in totals.
Replacement Reserves Report
Stevens Bridge Park Conce
9/13/2017
Location Name
EMG
Renamed
Item
Number
ID Cost Description Lifespan
(EUL)EAge RUL QuantityUnit Unit Cost Subtotal 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036
Deficiency
Repair
Estimate
Stevens Bridge Park Conce 3.1 617003 ADA, Parking, Designated Stall with Pavement Markings & Signage (Van), Install 0 0 0 1 EA $1,391.50 $1,392 $1,392 $1,392
Stevens Bridge Park Conce 5.2 606518 Roadway Concrete Curb, Concrete Curb & Gutter, Replace 25 9 16 400 LF $30.08 $12,030 $12,030 $12,030
Stevens Bridge Park Conce 5.2 606524 Parking Lots, Asphalt Pavement, Cut & Patch 25 23 2 300 SF $4.96 $1,488 $1,488 $1,488
Stevens Bridge Park Conce 5.2 606566 Parking Lots Seal Stripe, Asphalt Pavement, Seal & Stripe 5 2 3 10000 SF $0.38 $3,795 $3,795 $3,795 $3,795 $3,795 $15,180
Stevens Bridge Park Conce 5.2 606522 Parking Lot Driveway, Asphalt Pavement, Overlay 25 9 16 10000 SF $1.79 $17,873 $17,873 $17,873
Stevens Bridge Park Conce 5.2 606569 Pedestrian Pavement - Seal Asphalt, Sidewalk, Asphalt, Seal 5 2 3 5000 SF $0.38 $1,898 $1,898 $1,898 $1,898 $1,898 $7,590
Stevens Bridge Park Conce 5.2 606567 Pedestrian Pavement, Sidewalk, Asphalt, Replace 25 9 16 5000 SF $1.60 $8,020 $8,020 $8,020
Stevens Bridge Park Conce 5.2 606737 Pedestrian Pavement around Concession Stand, Concrete, Replace 30 12 18 400 SF $15.82 $6,329 $6,329 $6,329
Stevens Bridge Park Conce 5.2 606612 Pedestrian Pavement - Brick Pavers, Sidewalk, Clay Brick/Masonry Pavers, Replace 30 11 19 70 SF $20.11 $1,408 $1,408 $1,408
Stevens Bridge Park Conce 5.4 606574 Landscaping, Sod at Eroded Areas, Install 20 18 2 250 SF $1.01 $253 $253 $253
Stevens Bridge Park Conce 5.5 606577 Metal Halide Lighting Fixture - Parking Lot, 400 W, Replace 20 12 8 8 EA $748.18 $5,985 $5,985 $5,985
Stevens Bridge Park Conce 5.5 606782 Building Sign, Signage, Guide, Replace 10 3 7 1 EA $188.50 $189 $189 $189 $377
Stevens Bridge Park Conce 5.5 606610 Chain Link Gates, Chain Link Swing Gate, Small Manual, Replace 20 9 11 2 EA $569.49 $1,139 $1,139 $1,139
Stevens Bridge Park Conce 5.5 606609 Fences & Gates, Chain Link, 6' High, Replace 30 11 19 200 LF $37.54 $7,508 $7,508 $7,508
Stevens Bridge Park Conce 5.5 606482 Signage - Park, Property, Monument/Pylon, Replace 20 9 11 1 EA $1,602.00 $1,602 $1,602 $1,602
Stevens Bridge Park Conce 5.5 606630 Site Furnishings - Picnic Table, Plastic-Coated Metal, Replace 20 9 11 6 EA $1,391.50 $8,349 $8,349 $8,349
Stevens Bridge Park Conce 5.5 606613 Site Furnishings - Park Bench, Metal, Replace 20 9 11 2 EA $487.03 $974 $974 $974
Stevens Bridge Park Conce 5.5 606621 Site Furnishings - Bike Rack, , Replace 25 9 16 1 EA $1,090.00 $1,090 $1,090 $1,090
Stevens Bridge Park Conce 5.5 606521 Play Surfaces, Wood Chips, 3" Depth, Replace 20 17 3 2000 SF $0.51 $1,014 $1,014 $1,014
Stevens Bridge Park Conce 5.5 606666 Play Structure, Small, Replace 20 9 11 1 EA $18,975.00 $18,975 $18,975 $18,975
Stevens Bridge Park Conce 5.5 606697 Play Structure - Swings, Swing Set, Replace 20 9 11 1 EA $2,210.00 $2,210 $2,210 $2,210
Stevens Bridge Park Conce 5.5 606617 Sports Apparatus - Bleacher seats, Bleachers, Steel Frame w/ Aluminum Seats, Replace 25 9 16 2 EA $1,097.00 $2,194 $2,194 $2,194
Stevens Bridge Park Conce 5.5 606624 Pole Light - Playing Field, Exterior, 1000 W HID (Double Fixture, with Metal Pole), Replace 20 7 13 4 EA $8,523.34 $34,093 $34,093 $34,093
Stevens Bridge Park Conce 6.3 606743 Roof - Shingles, Asphalt Shingle, Replace 20 6 14 600 SF $3.02 $1,812 $1,812 $1,812
Stevens Bridge Park Conce 6.3 606744 Gutters & Downspouts, Aluminum w/ Fittings, Replace 10 4 6 100 LF $6.37 $637 $637 $637 $1,274
Stevens Bridge Park Conce 6.4 606740 Exterior Wall - Repoint, Brick or Brick Veneer, 1 Story, Repoint 25 8 17 600 SF $31.28 $18,770 $18,770 $18,770
Stevens Bridge Park Conce 6.6 606785 Window - Sliding, Aluminum Double-Glazed 24 SF, 1 Story, Replace 30 14 16 1 EA $870.45 $870 $870 $870
Stevens Bridge Park Conce 6.6 606746 Exterior Door, Steel, Replace 25 9 16 4 EA $950.12 $3,800 $3,800 $3,800
Stevens Bridge Park Conce 6.6 606768 Overhead Door, Aluminum Roll-Up, Small, Replace 35 19 16 1 EA $2,025.54 $2,026 $2,026 $2,026
Stevens Bridge Park Conce 6.6 606749 Overhead Door for concession window - 50 SF, Aluminum Roll-Up 144 SF, Replace 35 16 19 1 EA $1,025.54 $1,026 $1,026 $1,026
Stevens Bridge Park Conce 7.1 606779 Condensing Unit, Split System, 2.5 Ton, Replace 15 7 8 1 EA $3,366.36 $3,366 $3,366 $3,366
Stevens Bridge Park Conce 7.1 606849 Exhaust Fan, Centrifugal, 800 CFM, Replace 15 6 9 3 EA $1,021.87 $3,066 $3,066 $3,066
Stevens Bridge Park Conce 7.1 606858 Furnace, Electric, 41 to 50 MBH, Replace 20 9 11 1 EA $3,339.62 $3,340 $3,340 $3,340
Stevens Bridge Park Conce 7.2 606853 Toilet, Tankless (Water Closet), Replace 20 9 11 4 EA $842.97 $3,372 $3,372 $3,372
Stevens Bridge Park Conce 7.2 606932 Urinal, Vitreous China, Replace 20 9 11 2 EA $1,193.44 $2,387 $2,387 $2,387
Stevens Bridge Park Conce 7.2 606851 Lavatory, Vitreous China, Replace 20 9 11 6 EA $572.66 $3,436 $3,436 $3,436
Stevens Bridge Park Conce 7.2 606838 Sink - Kitchen, Vitreous China, Replace 20 6 14 1 EA $861.51 $862 $862 $862
Stevens Bridge Park Conce 7.2 606857 Backflow Preventer, 1", Replace 15 8 7 2 EA $1,276.01 $2,552 $2,552 $2,552
Stevens Bridge Park Conce 7.2 606904 Water Heater, Electric, Residential, 40 GAL, Replace 15 7 8 1 EA $1,438.90 $1,439 $1,439 $1,439
Stevens Bridge Park Conce 7.4 606859 Secondary Transformer, Dry, 50 kVA, Replace 30 13 17 1 EA $6,857.93 $6,858 $6,858 $6,858
Stevens Bridge Park Conce 7.4 606930 Main Distribution Panel, 480 Y, 277 V, 400 Amp, Replace 30 13 17 1 EA $9,202.02 $9,202 $9,202 $9,202
Stevens Bridge Park Conce 7.4 606747 Metal Halide Lighting Fixture, Wall Mount, 150 W, Replace 20 9 11 4 EA $478.47 $1,914 $1,914 $1,914
Stevens Bridge Park Conce 7.4 606797 Fluorescent Lighting Fixture, 80 W, Replace 20 9 11 3 EA $241.87 $726 $726 $726
Stevens Bridge Park Conce 7.4 606839 Emergency/Exit Combo LED, Replace 10 2 8 3 EA $487.51 $1,463 $1,463 $1,463 $2,925
Stevens Bridge Park Conce 7.6 606951 Fire Extinguisher, Safety, Replace 15 9 6 1 EA $306.54 $307 $307 $307
Location Name
EMG
Renamed
Item
Number
ID Cost Description Lifespan
(EUL)EAge RUL QuantityUnit Unit Cost Subtotal 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036
Deficiency
Repair
Estimate
Stevens Bridge Park Conce 8.1 606847 Interior Door, Steel, Replace 25 9 16 1 EA $950.12 $950 $950 $950
Stevens Bridge Park Conce 8.1 606843 Interior Wall Finish, Vinyl, Replace 15 2 * 13 700 SF $2.27 $1,592 $1,592 $1,592
Stevens Bridge Park Conce 8.1 606936 Interior Ceiling Finish - Painted Masonite, Fiberboard, Prep & Paint 10 4 6 250 SF $1.94 $484 $484 $484 $968
Stevens Bridge Park Conce 8.1 606846 Interior Ceiling Finish, Acoustical Tile (ACT), Replace 20 5 15 300 SF $3.11 $933 $933 $933
Stevens Bridge Park Conce 8.1 606802 Residential Appliances, Refrigerator, 14-18 CF, Replace 15 9 6 1 EA $956.04 $956 $956 $956
Stevens Bridge Park Conce 8.1 606793 Residential Appliances, Refrigerator, 14-18 CF, Replace 15 0 15 1 EA $956.04 $956 $956 $956
Stevens Bridge Park Conce 8.2 606801 Sink, Stainless Steel, 3 basin, Replace 20 9 11 1 EA $1,054.05 $1,054 $1,054 $1,054
Stevens Bridge Park Conce 8.2 606837 Kitchen Refrigerator, Refrigerator, 1-Door Reach-In, Replace 15 3 12 1 EA $2,515.00 $2,515 $2,515 $2,515
Totals, Unescalated $1,392 $0 $1,741 $6,706 $0 $0 $3,976 $2,741 $17,946 $3,066 $0 $49,477 $2,515 $39,786 $2,674 $1,889 $49,975 $35,018 $13,484 $9,941 $242,325
Totals, Escalated (3.0% inflation, compounded annually)$1,392 $0 $1,847 $7,328 $0 $0 $4,747 $3,370 $22,733 $4,000 $0 $68,488 $3,586 $58,427 $4,044 $2,944 $80,195 $57,879 $22,955 $17,431 $361,366
STEVENS BRIDGE PARK CONCESSION EMG PROJECT NO.: 122700.17R000-017.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
STEVENS BRIDGE PARK CONCESSION EMG PROJECT NO.: 122700.17R000-017.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: Stevens Bridge Park Concession, Yorkville, Kendall, Illinois 60560
Year Constructed/Renovated: 2007
Current Occupants: City of Yorkville Parks Department
Management Point of Contact:
City of Yorkville/Facilities, Erin Willrett, Manager
630.553.8574 phone
ewillrett@Yorkville.il.us email
Property Type: Concession stand building in a city park
Site Area: 8.0 acres
Building Area: 500 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: 80 spaces in open lot, shared with rest of park
Building Construction: CMU and brick veneer
Roof Construction: Gabled roof, shingled
Exterior Finishes: Brick Veneer
Heating, Ventilation and Air Conditioning: Split system HVAC with an electric furnace, exhaust fans
Fire and Life/Safety: Hydrant, fire extinguisher, exit signs, smoke alarm, and emergency lights
Dates of Visit: May 25, 2017
On-Site Point of Contact (POC): Tony Houle
Assessment and Report Prepared by: George Wozniczka
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer
For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Good HVAC Fair
Structure Good Plumbing Fair
Roof Good Electrical Good
Vertical Envelope Good Elevators --
Interiors Good Fire Fair
STEVENS BRIDGE PARK CONCESSION EMG PROJECT NO.: 122700.17R000-017.366
2
www.EMGcorp.com p 800.733.0660
The following bullet points highlight the most significant short term and modernization recommendations:
Parking asphalt pavement
Walkway asphalt pavement
Landscaping
Retrofitting a fire sprinkler system
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied in 2007and is in good overall condition.
According to property management personnel, the property has had an active capital improvement expenditure program over the past
three years, primarily consisting of painting, kitchen equipment, and asphalt pavement seal coating. Supporting documentation was not
provided in support of these claims but some of the work is evident.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 10.0% Fair
STEVENS BRIDGE PARK CONCESSION EMG PROJECT NO.: 122700.17R000-017.366
3
www.EMGcorp.com p 800.733.0660
Key Finding Metric
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 48.1% Poor
Current Replacement Value (CRV) 500 SF * $183.24 / SF = $91,618.56
Year 0 (Current Year) - Immediate Repairs (IR) $9,186
Years 1-10 – Replacement Reserves (RR) $44,026
Total Capital Needs $53,212
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Repair landscaping in deteriorated areas
Repair damaged parking lot
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
STEVENS BRIDGE PARK CONCESSION EMG PROJECT NO.: 122700.17R000-017.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: Pre-Survey Questionnaire
Appendix D: ADA Checklist
STEVENS BRIDGE PARK CONCESSION EMG PROJECT NO.: 122700.17R000-017.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
STEVENS BRIDGE PARK CONCESSION
3651 KENNEDY ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-017.366
www.EMGcorp.com p 800.733.0660
PHOTO
#1:
FRONT ELEVATION PHOTO
#2:
REAR ELEVATION
PHOTO
#3:
EAST ELEVATION PHOTO
#4:
WEST ELEVATION
PHOTO
#5:
PARK SIGN PHOTO
#6:
PARKING – ASPHALT AND CURB
STEVENS BRIDGE PARK CONCESSION
3651 KENNEDY ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-017.366
www.EMGcorp.com p 800.733.0660
PHOTO
#7:
DETERIORATED ASPHALT PHOTO
#8:
BLEACHER
PHOTO
#9:
SITE ASPHALT WALKWAY PHOTO
#10:
GARAGE
PHOTO
#11:
SITE PARKING LIGHTING PHOTO
#12:
LANDSCAPING
STEVENS BRIDGE PARK CONCESSION
3651 KENNEDY ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-017.366
www.EMGcorp.com p 800.733.0660
PHOTO
#13:
BICYCLE RACK PHOTO
#14:
STEEL BENCH
PHOTO
#15:
SHELTER PHOTO
#16:
SITE FENCING
PHOTO
#17:
PLAY STRUCTURE PHOTO
#18:
BUILDING SIGN
STEVENS BRIDGE PARK CONCESSION
3651 KENNEDY ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-017.366
www.EMGcorp.com p 800.733.0660
PHOTO
#19:
CONCRETE PAVEMENT PHOTO
#20:
EXTERIOR LIGHTS
PHOTO
#21:
DOWNSPOUT - GUTTER PHOTO
#22:
ROOF AND GUTTERS
PHOTO
#23:
MASONRY PHOTO
#24:
OVERHEAD DOOR
STEVENS BRIDGE PARK CONCESSION
3651 KENNEDY ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-017.366
www.EMGcorp.com p 800.733.0660
PHOTO
#25:
EXTERIOR ROLL-UP WINDOW PHOTO
#26:
EXTERIOR DOOR
PHOTO
#27:
SLIDING ALUMINUM WINDOW PHOTO
#28:
CEILING EXHAUST FAN
PHOTO
#29:
CONDENSING UNIT PHOTO
#30:
FURNACE
STEVENS BRIDGE PARK CONCESSION
3651 KENNEDY ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-017.366
www.EMGcorp.com p 800.733.0660
PHOTO
#31:
KITCHEN SINK PHOTO
#32:
RESTROOM TOILET
PHOTO
#33:
BACKFLOW PREVENTER PHOTO
#34:
ELECTRIC WATER HEATER
PHOTO
#35:
ELECTRICAL SERVICE AND METER PHOTO
#36:
EXIT-EMERGENCY LIGHT
STEVENS BRIDGE PARK CONCESSION
3651 KENNEDY ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-017.366
www.EMGcorp.com p 800.733.0660
PHOTO
#37:
INTERIOR T-8 LIGHT PHOTO
#38:
ELECTRICAL PANELS
PHOTO
#39:
STEP DOWN TRANSFORMER PHOTO
#40:
MAIN TRANSFORMER
PHOTO
#41:
HYDRANT PHOTO
#42:
FIRE EXTINGUISHER
STEVENS BRIDGE PARK CONCESSION
3651 KENNEDY ROAD
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-017.366
www.EMGcorp.com p 800.733.0660
PHOTO
#43:
INTERIOR WALL - PAINTED PHOTO
#44:
INTERIOR DOOR
PHOTO
#45:
FLOOR FINISH PHOTO
#46:
KITCHEN STAINLESS STEEL SINKS
PHOTO
#47:
REFRIGERATOR PHOTO
#48:
FREEZER
STEVENS BRIDGE PARK CONCESSION EMG PROJECT NO.: 122700.17R000-017.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name
Stevens Bridge Park Concession
Project Number:
122700.17R000-017.366
Source:
Google Map
On-Site Date:
May 25, 2017
STEVENS BRIDGE PARK CONCESSION EMG PROJECT NO.: 122700.17R000-017.366
www.EMGcorp.com p 800.733.0660
Appendix C:
Pre-Survey Questionnaire
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
This questionnaire must be completed by the property owner, the owner's designated representative, or someone
knowledgeable about the subject property. If the form is not completed, EMG’s Project Manager will require additional
time during the on-site visit with such a knowledgeable person in order to complete the questionnaire. During the site visit,
EMG's Field Observer may ask for details associated with selected questions. This questionnaire will be utilized as an
exhibit in EMG's final report.
Name of Institution: Stevens Bridge Concession
Name of Building: Concession Stand Building #: Concession
Name of person completing questionnaire: Tony Houle
Length of Association With the Property: 10 years, since constructed Phone Number: 630-885-3569
Site Information
Year of Construction? 2007
No. of Stories? 1
Total Site Area? 8 acres for park
Total Building Area? 500 Sqft
Inspections Date of Last
Inspection List of Any Outstanding Repairs Required
1. Elevators N/A
2. HVAC Mechanical, Electric,
Plumbing? 2017
3. Life-Safety/Fire? 2016
4. Roofs? Annually
Key Questions Response
Major Capital Improvements in Last 3 yrs. Batting cages
Planned Capital Expenditure For Next Year? None
Age of the Roof? 2007
What bldg. Systems Are Responsibilities of
Tenants? (HVAC/Roof/Interior/Exterior/Paving) All are park owned
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
ZONING, BUILDING DESIGN & LIFE SAFETY ISSUES
1 Are there any unresolved building,
fire, or zoning code issues? x
2 Is there any pending litigation
concerning the property? x
3 Are there any other significant
issues/hazards with the property? x
4 Are there any unresolved
construction defects at the
property?
x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
ZONING, BUILDING DESIGN & LIFE SAFETY ISSUES
5 Has any part of the property ever
contained visible suspect mold
growth?
x
6 Is there a mold Operations and
Maintenance Plan? x
7 Are there any recalled fire sprinkler
heads (Star, GEM, Central, and
Omega)?
x
8 Have there been indoor air quality
or mold related complaints from
tenants?
x
GENERAL SITE
9 Are there any problems with
erosion, storm water drainage or
areas of paving that do not drain?
x
10 Are there any problems with the
landscape irrigation systems? x
BUILDING STRUCTURE
11 Are there any problems with
foundations or structures? x
12 Is there any water infiltration in
basements or crawl spaces? x
13 Has a termite/wood boring insect
inspection been performed within
the last year?
x
BUILDING ENVELOPE
14 Are there any wall, or window
leaks? x
15 Are there any roof leaks? x
16 Is the roofing covered by a
warranty or bond? x
17 Are there any poorly insulated
areas? x
18 Is Fire Retardant Treated (FRT)
plywood used? x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
BUILDING ENVELOPE
19 Is exterior insulation and finish
system (EIFS) or a synthetic
stucco finish used?
x
BUILDING HVAC AND ELECTRICAL
20 Are there any leaks or pressure
problems with natural gas service? x
21 Does any part of the electrical
system use aluminum wiring? x
22 Do Residential units have a less
than 60-Amp service? x
23 Do Commercial units have less
than 200-Amp service? x
24 Are there any problems with the
utilities, such as inadequate
capacities?
x
ADA
25 Has the management previously
completed an ADA review? x After construction in 2007
26 Have any ADA improvements
been made to the property? x
27 Does a Barrier Removal Plan exist
for the property? x
28 Has the Barrier Removal Plan
been approved by an arms-length
third party?
x
29 Has building ownership or
management received any ADA
related complaints?
x
30 Does elevator equipment require
upgrades to meet ADA standards? x
PLUMBING
31 Is the property served by private
water well? x
32 Is the property served by a private
septic system or other waste
treatment systems?
x
33 Is polybutylene piping used? x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
PLUMBING
34 Are there any plumbing leaks or
water pressure problems? x
Additional Issues or Concerns That EMG Should Know About?
1. The property is in good condition
2.
3.
Items Provided to EMG Auditors
Yes No N/A Additional Comments?
Access to All Mechanical Spaces
Access to Roof/Attic Space
Access to Building As-Built Drawings Available
Site plan with bldg., roads, parking and other features
Contact Details for Mech, Elevator, Roof, Fire
Contractors:
List of Commercial Tenants in the property
Previous reports pertaining to the physical condition of
property.
ADA survey and status of improvements implemented.
Current / pending litigation related to property
condition.
Any brochures or marketing information.
________________________________ ___________
Signature of person Interviewed or completing form Date
STEVENS BRIDGE PARK CONCESSION EMG PROJECT NO.: 122700.17R000-017.366
www.EMGcorp.com p 800.733.0660
Appendix D:
ADA Checklist
Page 1 of 4
Date Completed: May 25, 2017
Property Name: Stevens Bridge Park Concession
EMG Project Number: 122700.17R000-017.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? After 2007 construction
2
Have any ADA improvements been made
to the property?
3
Does a Transition Plan / Barrier Removal
Plan exist for the property?
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
5
Is any litigation pending related to ADA
issues?
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
No ADA signs
2
Are there sufficient van-accessible parking
spaces available? Not marked
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
Not marked
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
No signage
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less)
2
Are ramps that appear longer than 6 ft
complete with railings on both sides?
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches?
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door?
2
If the main entrance is inaccessible, are
there alternate accessible entrances?
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)?
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage?
3
Is there a path of travel that does not
require the use of stairs?
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives?
2
Are there visual and audible signals inside
cars indicating floor change?
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons?
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door?
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)?
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication?
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route?
2
Are pull handles push/pull or lever type?
3
Are there audible and visual fire alarm
devices in the toilet rooms?
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)?
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)?
6
In unisex toilet rooms, are there safety
alarms with pull cords?
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)?
8
Are grab bars provided in toilet stalls?
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)?
10
Are sink handles operable with one hand
without grasping, pinching or twisting?
11
Are exposed pipes under sink sufficiently
insulated against contact?
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section.
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
Nearby play area was designed per ADA
guidelines
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
*Based on visual observation only. The slope was not confirmed through measurements.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Parks Storage Shed
201 West Hydraulic Avenue
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-018.366 June 20, 2017 May 25, 2017
FACILITY CONDITION ASSESSMENT
PARKS STORAGE SHED EMG PROJECT NO.: 122700.17R000-018.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
PARKS STORAGE SHED EMG PROJECT NO.: 122700.17R000-018.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: Parks Storage Shed, Yorkville, Kendall, Illinois 60560
Year Constructed/Renovated: 2007
Current Occupants: City of Yorkville Parks Department
Management Point of Contact:
City of Yorkville/Facilities, Erin Willrett, Manager
630.553.8574 phone
ewillrett@Yorkville.il.us email
Property Type: Shed
Site Area: 0.1 acres
Building Area: 50 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: 0 spaces assigned to storage shed, shared with Parks and Recreation Building
Building Construction: Pre-fabricated, wooden frame
Roof Construction: Gabled roof, shingles
Exterior Finishes: Wood Siding
Heating, Ventilation and Air Conditioning: None, natural convection only
Fire and Life/Safety: Hydrant
Dates of Visit: May 25, 2017
On-Site Point of Contact (POC): Tony Houle
Assessment and Report Prepared by: George Wozniczka
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer
For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Good HVAC --
Structure Fair Plumbing --
Roof Fair Electrical --
Vertical Envelope Fair Elevators --
Interiors Fair Fire --
PARKS STORAGE SHED EMG PROJECT NO.: 122700.17R000-018.366
2
www.EMGcorp.com p 800.733.0660
The following bullet points highlight the most significant short term and modernization recommendations:
Prep and painting
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have not been well maintained since it was first occupied in 2007and is in fair overall condition.
According to property management personnel, the property has had a limited capital improvement expenditure program over the past
three years.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
PARKS STORAGE SHED EMG PROJECT NO.: 122700.17R000-018.366
3
www.EMGcorp.com p 800.733.0660
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.0% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 38.1% Poor
Current Replacement Value (CRV) 50 SF * $183.24 / SF = $9,161.86
Year 0 (Current Year) - Immediate Repairs (IR) $0.00
Years 1-10 – Replacement Reserves (RR) $3,490
Total Capital Needs $3,490
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Paint Exterior
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
PARKS STORAGE SHED EMG PROJECT NO.: 122700.17R000-018.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: Pre-Survey Questionnaire
Appendix D: ADA Checklist
PARKS STORAGE SHED EMG PROJECT NO.: 122700.17R000-018.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
PARKS STORAGE SHED
201 WEST HYDRAULIC AVENUE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-018.366
www.EMGcorp.com p 800.733.0660
PHOTO
#1:
LOCATION OF PARKS ST0RAGE
SHED
PHOTO
#2:
SITE AND SHED
PHOTO
#3:
FRONT ELEVATION PHOTO
#4:
VIEW SHOWING RIGHT SIDE
ELEVATION
PHOTO
#5:
VIEW SHOWING REAR VIEW OF
SHED
PHOTO
#6:
LEFT ELEVATION
PARKS STORAGE SHED
201 WEST HYDRAULIC AVENUE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-018.366
www.EMGcorp.com p 800.733.0660
PHOTO
#7:
FOOTING (SUPPORT) OF SHED PHOTO
#8:
DETERIORATED DOOR
PHOTO
#9:
SHED WITH OPENED DOORS PHOTO
#10:
SHED PLYWOOD FLOOR DETAIL
PHOTO
#11:
SHED CEILING DETAIL PHOTO
#12:
SHED FAR WALL VIEW, VENT
PARKS STORAGE SHED
201 WEST HYDRAULIC AVENUE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-018.366
www.EMGcorp.com p 800.733.0660
PHOTO
#13:
SHED PAINT DETAIL PHOTO
#14:
CORNER OF DETERIORATED SHED
PHOTO
#15:
SHED ROOF DETAIL PHOTO
#16:
SIDING DETAIL
PHOTO
#17:
SHED FACIA
PARKS STORAGE SHED EMG PROJECT NO.: 122700.17R000-018.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name
Parks Storage Shed
Project Number:
122700.17R000-018.366
Source:
Google Map
On-Site Date:
May 25, 2017
PARKS STORAGE SHED EMG PROJECT NO.: 122700.17R000-018.366
www.EMGcorp.com p 800.733.0660
Appendix C:
Pre-Survey Questionnaire
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
This questionnaire must be completed by the property owner, the owner's designated representative, or someone
knowledgeable about the subject property. If the form is not completed, EMG’s Project Manager will require additional
time during the on-site visit with such a knowledgeable person in order to complete the questionnaire. During the site visit,
EMG's Field Observer may ask for details associated with selected questions. This questionnaire will be utilized as an
exhibit in EMG's final report.
Name of Institution: Parks Department – City of Yorkville
Name of Building: Parks storage shed Building #: Shed
Name of person completing questionnaire: Tony Houle
Length of Association With the Property: 10 years, since constructed Phone Number: 630-885-3569
Site Information
Year of Construction? 2007
No. of Stories? 1
Total Site Area? .1 acres
Total Building Area? 50 Sqft
Inspections Date of Last
Inspection List of Any Outstanding Repairs Required
1. Elevators N/A
2. HVAC Mechanical, Electric,
Plumbing? N/A
3. Life-Safety/Fire? N/A
4. Roofs? Annually
Key Questions Response
Major Capital Improvements in Last 3 yrs. None
Planned Capital Expenditure For Next Year? None
Age of the Roof? 2007
What bldg. Systems Are Responsibilities of
Tenants? (HVAC/Roof/Interior/Exterior/Paving) All
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
ZONING, BUILDING DESIGN & LIFE SAFETY ISSUES
1 Are there any unresolved building,
fire, or zoning code issues? x
2 Is there any pending litigation
concerning the property? x
3 Are there any other significant
issues/hazards with the property? x
4 Are there any unresolved
construction defects at the
property?
x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
ZONING, BUILDING DESIGN & LIFE SAFETY ISSUES
5 Has any part of the property ever
contained visible suspect mold
growth?
x
6 Is there a mold Operations and
Maintenance Plan? x
7 Are there any recalled fire sprinkler
heads (Star, GEM, Central, and
Omega)?
x
8 Have there been indoor air quality
or mold related complaints from
tenants?
x
GENERAL SITE
9 Are there any problems with
erosion, storm water drainage or
areas of paving that do not drain?
x
10 Are there any problems with the
landscape irrigation systems? x
BUILDING STRUCTURE
11 Are there any problems with
foundations or structures? x
12 Is there any water infiltration in
basements or crawl spaces? x
13 Has a termite/wood boring insect
inspection been performed within
the last year?
x
BUILDING ENVELOPE
14 Are there any wall, or window
leaks? x
15 Are there any roof leaks? x
16 Is the roofing covered by a
warranty or bond? x
17 Are there any poorly insulated
areas? x
18 Is Fire Retardant Treated (FRT)
plywood used? x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
BUILDING ENVELOPE
19 Is exterior insulation and finish
system (EIFS) or a synthetic
stucco finish used?
x
BUILDING HVAC AND ELECTRICAL
20 Are there any leaks or pressure
problems with natural gas service? x
21 Does any part of the electrical
system use aluminum wiring? x
22 Do Residential units have a less
than 60-Amp service? x
23 Do Commercial units have less
than 200-Amp service? x
24 Are there any problems with the
utilities, such as inadequate
capacities?
x
ADA
25 Has the management previously
completed an ADA review? x This is a shed
26 Have any ADA improvements
been made to the property? x
27 Does a Barrier Removal Plan exist
for the property? x
28 Has the Barrier Removal Plan
been approved by an arms-length
third party?
x
29 Has building ownership or
management received any ADA
related complaints?
x
30 Does elevator equipment require
upgrades to meet ADA standards? x
PLUMBING
31 Is the property served by private
water well? x
32 Is the property served by a private
septic system or other waste
treatment systems?
x
33 Is polybutylene piping used? x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
PLUMBING
34 Are there any plumbing leaks or
water pressure problems? x
Additional Issues or Concerns That EMG Should Know About?
1. The property is in fair condition. Exterior painting is required
2.
3.
Items Provided to EMG Auditors
Yes No N/A Additional Comments?
Access to All Mechanical Spaces
Access to Roof/Attic Space
Access to Building As-Built Drawings
Site plan with bldg., roads, parking and other features
Contact Details for Mech, Elevator, Roof, Fire
Contractors:
List of Commercial Tenants in the property
Previous reports pertaining to the physical condition of
property.
ADA survey and status of improvements implemented.
Current / pending litigation related to property
condition.
Any brochures or marketing information.
________________________________ ___________
Signature of person Interviewed or completing form Date
PARKS STORAGE SHED EMG PROJECT NO.: 122700.17R000-018.366
www.EMGcorp.com p 800.733.0660
Appendix D:
ADA Checklist
Page 1 of 4
Date Completed: May 25, 2017
Property Name: Parks Storage Shed
EMG Project Number: 122700.17R000-018.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property?
2
Have any ADA improvements been made
to the property?
3
Does a Transition Plan / Barrier Removal
Plan exist for the property?
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
5
Is any litigation pending related to ADA
issues?
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
No parking for shed
2
Are there sufficient van-accessible parking
spaces available?
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less)
2
Are ramps that appear longer than 6 ft
complete with railings on both sides?
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches?
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door?
2
If the main entrance is inaccessible, are
there alternate accessible entrances?
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)?
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage?
3
Is there a path of travel that does not
require the use of stairs?
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives?
2
Are there visual and audible signals inside
cars indicating floor change?
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons?
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door?
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)?
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication?
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route?
2
Are pull handles push/pull or lever type?
3
Are there audible and visual fire alarm
devices in the toilet rooms?
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)?
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)?
6
In unisex toilet rooms, are there safety
alarms with pull cords?
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)?
8
Are grab bars provided in toilet stalls?
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)?
10
Are sink handles operable with one hand
without grasping, pinching or twisting?
11
Are exposed pipes under sink sufficiently
insulated against contact?
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section.
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
*Based on visual observation only. The slope was not confirmed through measurements.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Non-Park Tin Storage Shed
1785 Walsh Drive
Yorkville, Illinois, 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-019.366 June 20, 2017 May 26, 2017
FACILITY CONDITION ASSESSMENT
NON-PARKS TIN STORAGE SHED EMG PROJECT NO.: 122700.17R000-019.366
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
NON-PARKS TIN STORAGE SHED EMG PROJECT NO.: 122700.17R000-019.366
1
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 1785 Walsh Drive, Yorkville, Kendall, Illinois 60560
Year Constructed/Renovated: 1998
Current Occupants: City of Yorkville Parks Department
Management Point of Contact:
City of Yorkville/Facilities, Erin Willrett, Manager
630.553.8574 phone
ewillrett@Yorkville.il.us email
Property Type: City Park, shelter, play lot and grounds
Site Area: 3.0 acres
Building Area: 500 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: 0 spaces in open lots, street parking only
Building Construction: Steel frame with metal roof, a park shelter. No walls
Roof Construction: Gabled roof, sheet metal
Exterior Finishes: Metal Siding
Heating, Ventilation and Air Conditioning: None, natural convection only
Fire and Life/Safety: Hydrants
Dates of Visit: May 26, 2017
On-Site Point of Contact (POC): Tony Houle
Assessment and Report Prepared by: George Wozniczka
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer
For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Good HVAC --
Structure Good Plumbing --
Roof Fair Electrical Good
Vertical Envelope Good Elevators --
NON-PARKS TIN STORAGE SHED EMG PROJECT NO.: 122700.17R000-019.366
2
Systemic Condition Summary
Interiors Good Fire --
The following bullet points highlight the most significant short term and modernization recommendations:
Seal and stripe play surfaces
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied in 1998 and is in good overall condition.
According to property management personnel, the property has had an active capital improvement expenditure program over the past
three years, primarily consisting of asphalt pavement seal coating. Supporting documentation was not provided in support of these
claims but some of the work is evident.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
NON-PARKS TIN STORAGE SHED EMG PROJECT NO.: 122700.17R000-019.366
3
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.0% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 25.8% Poor
Current Replacement Value (CRV) 500 SF * $183.24 / SF = $91,618.56
Year 0 (Current Year) - Immediate Repairs (IR) $0.00
Years 1-10 – Replacement Reserves (RR) $23,619
Total Capital Needs $23,619
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Seal and stripe asphalt playground
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
NON-PARKS TIN STORAGE SHED EMG PROJECT NO.: 122700.17R000-019.366
4
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: Pre-Survey Questionnaire
Appendix D: ADA Checklist
NON-PARKS TIN STORAGE SHED EMG PROJECT NO.: 122700.17R000-019.366
Appendix A:
Photographic Record
NON-PARK TIN STORAGE SHED
1785 WALSH DRIVE
YORKVILLE, IL 60560 EMG PROJECT NO: 122700.17R000-019.366
www.EMGcorp.com p 800.733.0660
PHOTO
#1:
METAL PARK SHELTER PHOTO
#2:
SIDE VIEW OF SHELTER
PHOTO
#3:
END VIEW OF SHELTER PHOTO
#4:
CONCRETE UNDER SHELTER
PHOTO
#5:
PARK SITE LOCATION PHOTO
#6:
PARK SIGN
NON-PARK TIN STORAGE SHED
1785 WALSH DRIVE
YORKVILLE, IL 60560 EMG PROJECT NO: 122700.17R000-019.366
www.EMGcorp.com p 800.733.0660
PHOTO
#7:
ADA ACCESSIBLE ENTRANCE PHOTO
#8:
INSIDE VIEW OF SHELTER
PHOTO
#9:
BENCH PHOTO
#10:
WOOD CHIP MULCH
PHOTO
#11:
METAL ROOF PHOTO
#12:
CEILING AND INTERIOR WALL
DETAIL
NON-PARK TIN STORAGE SHED
1785 WALSH DRIVE
YORKVILLE, IL 60560 EMG PROJECT NO: 122700.17R000-019.366
www.EMGcorp.com p 800.733.0660
PHOTO
#13:
LANDSCAPING PHOTO
#14:
METAL RAILING
PHOTO
#15:
STORM DRAIN PHOTO
#16:
LANDSCAPING
PHOTO
#17:
CONCRETE WALKWAY PHOTO
#18:
STORM SEWER DRAIN
NON-PARK TIN STORAGE SHED
1785 WALSH DRIVE
YORKVILLE, IL 60560 EMG PROJECT NO: 122700.17R000-019.366
www.EMGcorp.com p 800.733.0660
PHOTO
#19:
SWING SET PHOTO
#20:
SAND PLAY AREA
PHOTO
#21:
PLAY STRUCTURE PHOTO
#22:
METAL STAIRS
PHOTO
#23:
PARK BENCHES PHOTO
#24:
CMU RETAINING WALL
NON-PARK TIN STORAGE SHED
1785 WALSH DRIVE
YORKVILLE, IL 60560 EMG PROJECT NO: 122700.17R000-019.366
www.EMGcorp.com p 800.733.0660
PHOTO
#25:
BASKETBALL COURT PHOTO
#26:
BASKETBALL BACKSTOP
PHOTO
#27:
INSTRUCTION SIGN PHOTO
#28:
ASPHALT STRIPING
PHOTO
#29:
LAMP PHOTO
#30:
HYDRANT
NON-PARK TIN STORAGE SHED
1785 WALSH DRIVE
YORKVILLE, IL 60560 EMG PROJECT NO: 122700.17R000-019.366
www.EMGcorp.com p 800.733.0660
PHOTO
#31:
INTERIOR PAINTED SURFACE PHOTO
#32:
PAINTED SURFACE, SCRATCHED
NON-PARKS TIN STORAGE SHED EMG PROJECT NO.: 122700.17R000-019.366
Appendix B:
Site Plan
Site Plan
Project Name
Non-Park Tin Storage Shed - Sunflower
Project Number:
122700.17R000-019.366
Source:
Google Map
On-Site Date:
May 26, 2017
NON-PARKS TIN STORAGE SHED EMG PROJECT NO.: 122700.17R000-019.366
Appendix C:
Pre-Survey Questionnaire
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
This questionnaire must be completed by the property owner, the owner's designated representative, or someone
knowledgeable about the subject property. If the form is not completed, EMG’s Project Manager will require additional
time during the on-site visit with such a knowledgeable person in order to complete the questionnaire. During the site visit,
EMG's Field Observer may ask for details associated with selected questions. This questionnaire will be utilized as an
exhibit in EMG's final report.
Name of Institution: Non-Park Tin Storage Shed
Name of Building: Shed Building #: Shed
Name of person completing questionnaire: Tony Houle
Length of Association With the Property: 10 years, since constructed Phone Number: 630-885-3569
Site Information
Year of Construction? 1998
No. of Stories? 1
Total Site Area? 4 acres
Total Building Area? 500 Sqft
Inspections Date of Last
Inspection List of Any Outstanding Repairs Required
1. Elevators N/A
2. HVAC Mechanical, Electric,
Plumbing? N/A
3. Life-Safety/Fire? N/A
4. Roofs? Annually
Key Questions Response
Major Capital Improvements in Last 3 yrs. Added chip mulch
Planned Capital Expenditure For Next Year? None
Age of the Roof? 1998
What bldg. Systems Are Responsibilities of
Tenants? (HVAC/Roof/Interior/Exterior/Paving) All
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
ZONING, BUILDING DESIGN & LIFE SAFETY ISSUES
1 Are there any unresolved building,
fire, or zoning code issues? x
2 Is there any pending litigation
concerning the property? x
3 Are there any other significant
issues/hazards with the property? x
4 Are there any unresolved
construction defects at the
property?
x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
QUESTION Y N Unk NA COMMENTS
5 Has any part of the property ever
contained visible suspect mold
growth?
x
6 Is there a mold Operations and
Maintenance Plan? x
7 Are there any recalled fire sprinkler
heads (Star, GEM, Central, and
Omega)?
x
8 Have there been indoor air quality
or mold related complaints from
tenants?
x
GENERAL SITE
9 Are there any problems with
erosion, storm water drainage or
areas of paving that do not drain?
x
10 Are there any problems with the
landscape irrigation systems? x
BUILDING STRUCTURE
11 Are there any problems with
foundations or structures? x
12 Is there any water infiltration in
basements or crawl spaces? x
13 Has a termite/wood boring insect
inspection been performed within
the last year?
x
BUILDING ENVELOPE
14 Are there any wall, or window
leaks? x
15 Are there any roof leaks? x
16 Is the roofing covered by a
warranty or bond? x
17 Are there any poorly insulated
areas? x
18 Is Fire Retardant Treated (FRT)
plywood used? x
19 Is exterior insulation and finish
system (EIFS) or a synthetic
stucco finish used?
x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
BUILDING HVAC AND ELECTRICAL
20 Are there any leaks or pressure
problems with natural gas service? x
21 Does any part of the electrical
system use aluminum wiring? x
22 Do Residential units have a less
than 60-Amp service? x
23 Do Commercial units have less
than 200-Amp service? x
24 Are there any problems with the
utilities, such as inadequate
capacities?
x
ADA
25 Has the management previously
completed an ADA review? x Park designed per ADA guidelines
26 Have any ADA improvements
been made to the property? x
27 Does a Barrier Removal Plan exist
for the property? x
28 Has the Barrier Removal Plan
been approved by an arms-length
third party?
x
29 Has building ownership or
management received any ADA
related complaints?
x
30 Does elevator equipment require
upgrades to meet ADA standards? x
PLUMBING
31 Is the property served by private
water well? x
32 Is the property served by a private
septic system or other waste
treatment systems?
x
33 Is polybutylene piping used? x
34 Are there any plumbing leaks or
water pressure problems? x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Additional Issues or Concerns That EMG Should Know About?
1. The property is in good condition
2.
3.
Items Provided to EMG Auditors
Yes No N/A Additional Comments?
Access to All Mechanical Spaces No mechanical spaces
Access to Roof/Attic Space
Access to Building As-Built Drawings Available
Site plan with bldg., roads, parking and other features
Contact Details for Mech, Elevator, Roof, Fire
Contractors:
List of Commercial Tenants in the property
Previous reports pertaining to the physical condition of
property.
ADA survey and status of improvements implemented.
Current / pending litigation related to property
condition.
Any brochures or marketing information.
________________________________ ___________
Signature of person Interviewed or completing form Date
NON-PARKS TIN STORAGE SHED EMG PROJECT NO.: 122700.17R000-019.366
Appendix D:
ADA Checklist
Page 1 of 4
Date Completed: May 26, 2017
Property Name: Non-Park Tin Storage Shed
EMG Project Number: 122700.17R000-019.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? Park was designed in 1998 per ADA
guidelines
2
Have any ADA improvements been made
to the property?
3
Does a Transition Plan / Barrier Removal
Plan exist for the property?
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
5
Is any litigation pending related to ADA
issues?
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
Street parking only
2
Are there sufficient van-accessible parking
spaces available?
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less)
2
Are ramps that appear longer than 6 ft
complete with railings on both sides?
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches?
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door?
2
If the main entrance is inaccessible, are
there alternate accessible entrances?
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)?
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage?
3
Is there a path of travel that does not
require the use of stairs?
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives?
2
Are there visual and audible signals inside
cars indicating floor change?
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons?
Page 3 of 4
Elevators (cont.) Yes No NA Comments
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door?
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)?
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication?
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route?
2
Are pull handles push/pull or lever type?
3
Are there audible and visual fire alarm
devices in the toilet rooms?
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)?
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)?
6
In unisex toilet rooms, are there safety
alarms with pull cords?
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)?
8
Are grab bars provided in toilet stalls?
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)?
10
Are sink handles operable with one hand
without grasping, pinching or twisting?
11
Are exposed pipes under sink sufficiently
insulated against contact?
Page 4 of 4
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section.
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
Play area was designed per ADA guidelines.
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
*Based on visual observation only. The slope was not confirmed through measurements.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Town Square Park Gazebo
301 North Bridget Street
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-020.366 June 22, 2017 May 26, 2017
FACILITY CONDITION ASSESSMENT
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
TOWN SQUARE PARK GAZEBO EMG PROJECT NO.: 122700.17R000-020.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
TOWN SQUARE PARK GAZEBO EMG PROJECT NO.: 122700.17R000-020.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 301 North Bridge Street, Yorkville, Kendall, Illinois 60560
Year Constructed/Renovated: 1990
Current Occupants: City of Yorkville Parks Department
Management Point of Contact:
City of Yorkville/Facilities, Erin Willrett, Manager
630.553.8574 phone
ewillrett@Yorkville.il.us email
Property Type: City Park Gazebo
Site Area: 3.0 acres
Building Area: 200 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: 20 spaces in open lot, next to street
Building Construction: Wood frame. No walls
Roof Construction: Gazebo octagon style roof, cedar shingled
Exterior Finishes: Painted Wood
Heating, Ventilation and Air Conditioning: None, natural convection only
Fire and Life/Safety: Hydrants
Dates of Visit: May 26, 2017
On-Site Point of Contact (POC): Tony Houle
Assessment and Report Prepared by: George Wozniczka
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Good HVAC --
Structure Good Plumbing Good
Roof Fair Electrical Good
Vertical Envelope Fair Elevators --
Interiors Fair Fire --
TOWN SQUARE PARK GAZEBO EMG PROJECT NO.: 122700.17R000-020.366
2
www.EMGcorp.com p 800.733.0660
The following bullet points highlight the most significant short term and modernization recommendations:
Seal and stripe asphalt parking area
Landscaping
ADA parking signage
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied in 1990 and is in good overall condition.
According to property management personnel, the property has had an active capital improvement expenditure program over the past
three years, primarily consisting of adding concrete pavements and painting. Supporting documentation was not provided in support of
these claims but some of the work is evident.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
TOWN SQUARE PARK GAZEBO EMG PROJECT NO.: 122700.17R000-020.366
3
www.EMGcorp.com p 800.733.0660
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.1% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 100.0% Poor
Current Replacement Value (CRV) 200 SF * $183.24 / SF = $36,648.00
Year 0 (Current Year) - Immediate Repairs (IR) $281
Years 1-10 – Replacement Reserves (RR) $44,883
Total Capital Needs $45,164
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Landscaping in deteriorated areas
Add ADA parking signage
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
TOWN SQUARE PARK GAZEBO EMG PROJECT NO.: 122700.17R000-020.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: Pre-Survey Questionnaire
Appendix D: ADA Checklist
TOWN SQUARE PARK GAZEBO EMG PROJECT NO.: 122700.17R000-020.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
TOWN SQUARE PARK GAZEBO
301 NORTH BRIDGET STREET
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-020.366
www.EMGcorp.com p 800.733.0660
PHOTO
#1:
FRONT ELEVATION PHOTO
#2:
RIGHT SIDE ELEVATION
PHOTO
#3:
REAR ELEVATION PHOTO
#4:
BUILDING SIGN
PHOTO
#5:
PARK SITE PHOTO
#6:
CONCRETE SIDEWALKS
TOWN SQUARE PARK GAZEBO
301 NORTH BRIDGET STREET
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-020.366
www.EMGcorp.com p 800.733.0660
PHOTO
#7:
PARKING PHOTO
#8:
DRAINAGE SYSTEM
PHOTO
#9:
CURB PHOTO
#10:
LANDSCAPING
PHOTO
#11:
SITE WALL/FENCE PHOTO
#12:
PARK SIGN
TOWN SQUARE PARK GAZEBO
301 NORTH BRIDGET STREET
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-020.366
www.EMGcorp.com p 800.733.0660
PHOTO
#13:
SITE PICNIC TABLE PHOTO
#14:
CONCRETE FOUNDATION AT
GAZEBO
PHOTO
#15:
GAZEBO WALL PHOTO
#16:
CEDAR ROOF SHINGLES
PHOTO
#17:
DRINKING FOUNTAIN PHOTO
#18:
TRANSFORMER
TOWN SQUARE PARK GAZEBO
301 NORTH BRIDGET STREET
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-020.366
www.EMGcorp.com p 800.733.0660
PHOTO
#19:
ELECTRICAL PANELS PHOTO
#20:
GAZEBO CEILING LIGHT
PHOTO
#21:
LED LIGHT PHOTO
#22:
POLE LIGHT
PHOTO
#23:
HYDRANT PHOTO
#24:
GAZEBO WOODEN CEILING
TOWN SQUARE PARK GAZEBO
301 NORTH BRIDGET STREET
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-020.366
www.EMGcorp.com p 800.733.0660
PHOTO
#25:
PAINTED EXTERIOR PHOTO
#26:
SITE STRUCTURE
TOWN SQUARE PARK GAZEBO EMG PROJECT NO.: 122700.17R000-020.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name
Town Square Park Gazebo
Project Number:
122700.17R000-020.366
Source:
Google Map
On-Site Date:
May 26, 2017
TOWN SQUARE PARK GAZEBO EMG PROJECT NO.: 122700.17R000-020.366
www.EMGcorp.com p 800.733.0660
Appendix C:
Pre-Survey Questionnaire
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
This questionnaire must be completed by the property owner, the owner's designated representative, or someone
knowledgeable about the subject property. If the form is not completed, EMG’s Project Manager will require additional
time during the on-site visit with such a knowledgeable person in order to complete the questionnaire. During the site visit,
EMG's Field Observer may ask for details associated with selected questions. This questionnaire will be utilized as an
exhibit in EMG's final report.
Name of Institution: Town Square Park Gazebo
Name of Building: Gazebo Building #: Gazebo
Name of person completing questionnaire: Tony Houle
Length of Association With the Property: 16 years, Phone Number: 630-885-3569
Site Information
Year of Construction? 1990
No. of Stories? 1
Total Site Area? 2 acres
Total Building Area? 200 Sq ft
Inspections Date of Last
Inspection List of Any Outstanding Repairs Required
1. Elevators N/A
2. HVAC Mechanical, Electric,
Plumbing? N/A Outdoor drinking fountain is inspected annually
3. Life-Safety/Fire? N/A
4. Roofs? Annually
Key Questions Response
Major Capital Improvements in Last 3 yrs. Concrete pads
Planned Capital Expenditure For Next Year? None
Age of the Roof? 1990, Cedar Shingles
What bldg. Systems Are Responsibilities of
Tenants? (HVAC/Roof/Interior/Exterior/Paving) All
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
ZONING, BUILDING DESIGN & LIFE SAFETY ISSUES
1 Are there any unresolved building,
fire, or zoning code issues? x
2 Is there any pending litigation
concerning the property? x
3 Are there any other significant
issues/hazards with the property? x
4 Are there any unresolved
construction defects at the
property?
x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
ZONING, BUILDING DESIGN & LIFE SAFETY ISSUES
5 Has any part of the property ever
contained visible suspect mold
growth?
x
6 Is there a mold Operations and
Maintenance Plan? x
7 Are there any recalled fire sprinkler
heads (Star, GEM, Central, and
Omega)?
x
8 Have there been indoor air quality
or mold related complaints from
tenants?
x
GENERAL SITE
9 Are there any problems with
erosion, storm water drainage or
areas of paving that do not drain?
x
10 Are there any problems with the
landscape irrigation systems? x
BUILDING STRUCTURE
11 Are there any problems with
foundations or structures? x
12 Is there any water infiltration in
basements or crawl spaces? x
13 Has a termite/wood boring insect
inspection been performed within
the last year?
x
BUILDING ENVELOPE
14 Are there any wall, or window
leaks? x
15 Are there any roof leaks? x
16 Is the roofing covered by a
warranty or bond? x
17 Are there any poorly insulated
areas? x
18 Is Fire Retardant Treated (FRT)
plywood used? x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
BUILDING ENVELOPE
19 Is exterior insulation and finish
system (EIFS) or a synthetic
stucco finish used?
x
BUILDING HVAC AND ELECTRICAL
20 Are there any leaks or pressure
problems with natural gas service? x No gas service
21 Does any part of the electrical
system use aluminum wiring? x
22 Do Residential units have a less
than 60-Amp service? x
23 Do Commercial units have less
than 200-Amp service? x
24 Are there any problems with the
utilities, such as inadequate
capacities?
x
ADA
25 Has the management previously
completed an ADA review? x After 1990 construction
26 Have any ADA improvements
been made to the property? x
27 Does a Barrier Removal Plan exist
for the property? x
28 Has the Barrier Removal Plan
been approved by an arms-length
third party?
x
29 Has building ownership or
management received any ADA
related complaints?
x
30 Does elevator equipment require
upgrades to meet ADA standards? x
PLUMBING
31 Is the property served by private
water well? x
32 Is the property served by a private
septic system or other waste
treatment systems?
x
33 Is polybutylene piping used? x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
PLUMBING
34 Are there any plumbing leaks or
water pressure problems? x
Additional Issues or Concerns That EMG Should Know About?
1. The property is in good condition
2.
3.
Items Provided to EMG Auditors
Yes No N/A Additional Comments?
Access to All Mechanical Spaces
Access to Roof/Attic Space
Access to Building As-Built Drawings Available
Site plan with bldg., roads, parking and other features
Contact Details for Mech, Elevator, Roof, Fire
Contractors:
List of Commercial Tenants in the property
Previous reports pertaining to the physical condition of
property.
ADA survey and status of improvements implemented.
Current / pending litigation related to property
condition.
Any brochures or marketing information.
________________________________ ___________
Signature of person Interviewed or completing form Date
TOWN SQUARE PARK GAZEBO EMG PROJECT NO.: 122700.17R000-020.366
www.EMGcorp.com p 800.733.0660
Appendix D:
ADA Checklist
Page 1 of 4
Date Completed: May 26, 2017
Property Name: Town Square Park Gazebo
EMG Project Number: 122700.17R000-020.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? After 1990 construction
2
Have any ADA improvements been made
to the property? Property was built per ADA guidelines.
3
Does a Transition Plan / Barrier Removal
Plan exist for the property?
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
5
Is any litigation pending related to ADA
issues?
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
Next to street parking
2
Are there sufficient van-accessible parking
spaces available?
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less)
2
Are ramps that appear longer than 6 ft
complete with railings on both sides?
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches?
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? No doors at the gazebo
2
If the main entrance is inaccessible, are
there alternate accessible entrances?
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)?
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage?
3
Is there a path of travel that does not
require the use of stairs?
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives?
2
Are there visual and audible signals inside
cars indicating floor change?
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons?
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door?
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)?
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication?
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route?
2
Are pull handles push/pull or lever type?
3
Are there audible and visual fire alarm
devices in the toilet rooms?
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)?
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)?
6
In unisex toilet rooms, are there safety
alarms with pull cords?
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)?
8
Are grab bars provided in toilet stalls?
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)?
10
Are sink handles operable with one hand
without grasping, pinching or twisting?
11
Are exposed pipes under sink sufficiently
insulated against contact?
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section.
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
*Based on visual observation only. The slope was not confirmed through measurements.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
COUNTRYSIDE LIFT
1975 NORTH BRIDGE STREET
YORKVILLE, ILLINOIS 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-023.366 June 22, 2017 May 23, 2017
FACILITY CONDITION ASSESSMENT
COUNTRYSIDE LIFT EMG PROJECT NO.: 122700.17R000-023.366
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
COUNTRYSIDE LIFT EMG PROJECT NO.: 122700.17R000-023.366
1
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 1975 North Bridge Street, Yorkville, IL 60560
Year Constructed/Renovated: 2007
Current Occupants: City of Yorkville
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Lift Station
Site Area: 0.9 acres
Building Area: 1,400 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: Unmarked asphalt paved driveway
Building Construction: Masonry bearing walls and wood-framed roofs
Roof Construction: Gabled roofs with asphalt shingles
Exterior Finishes: Brick Veneer
Heating, Ventilation and Air Conditioning: Suspended gas and electric unit heaters
Fire and Life/Safety: Strobes and extinguisher
Dates of Visit: May 23, 2017
On-Site Point of Contact (POC): Eric Dhuse
Assessment and Report Prepared by: Tammy Prusa
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer
For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Good HVAC Fair
Structure Good Plumbing Fair
Roof Fair Electrical Fair
Vertical Envelope Good Elevators --
COUNTRYSIDE LIFT EMG PROJECT NO.: 122700.17R000-023.366
2
Systemic Condition Summary
Interiors Fair Fire Fair
The following bullet points highlight the most significant short term and modernization recommendations:
There were no short term or modernization recommendations.
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in fair overall condition.
The property has had no major capital improvements. The property is less than 12 years old and has not required any major capital
improvements.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
COUNTRYSIDE LIFT EMG PROJECT NO.: 122700.17R000-023.366
3
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.0% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 52.2% Poor
Current Replacement Value (CRV) 1,400 SF * $183.24 / SF = $256,536.00
Year 0 (Current Year) - Immediate Repairs (IR) $0.00
Years 1-10 – Replacement Reserves (RR) $133,788.00
Total Capital Needs $133,788.00
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
There were no short term or modernization recommendations
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
COUNTRYSIDE LIFT EMG PROJECT NO.: 122700.17R000-023.366
4
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: Pre-Survey Questionnaire
Appendix D: ADA Checklist
COUNTRYSIDE LIFT EMG PROJECT NO.: 122700.17R000-023.366
Appendix A:
Photographic Record
COUNTRYSIDE LIFT
1975 NORTH BRIDGE STREET
YORKVILLE ILLINOIS EMG PROJECT NO: 122700.17R000-023.366
#1: FRONT ELEVATION
#2: LEFT ELEVATION
#3: REAR ELEVATION
#4: RIGHT ELEVATION
#5: PARKING LOTS, ASPHALT
PAVEMENT
#6: ROOF, ASPHALT SHINGLE
COUNTRYSIDE LIFT
1975 NORTH BRIDGE STREET
YORKVILLE ILLINOIS EMG PROJECT NO: 122700.17R000-023.366
#7: EXTERIOR WALL, CONCRETE
BLOCK (CMU)
#8: EXTERIOR WALL, BRICK VENEER
#9: WINDOW, ALUMINUM DOUBLE-
GLAZED
#10: EXTERIOR DOOR, STEEL
#11: UNIT HEATER, NATURAL GAS
#12: EXHAUST FAN, PROPELLER
COUNTRYSIDE LIFT
1975 NORTH BRIDGE STREET
YORKVILLE ILLINOIS EMG PROJECT NO: 122700.17R000-023.366
#13: UNIT HEATER, ELECTRIC
#14: EXHAUST FAN, CENTRIFUGAL
#15: EXHAUST FAN, INLINE
#16: BACKFLOW PREVENTER
#17: TOILET, FLUSH TANK (WATER
CLOSET)
#18: LAVATORY, VITREOUS CHINA
COUNTRYSIDE LIFT
1975 NORTH BRIDGE STREET
YORKVILLE ILLINOIS EMG PROJECT NO: 122700.17R000-023.366
#19: TRANSFER SWITCH, AUTOMATIC
(ATS)
#20: TRANSFER SWITCH, AUTOMATIC
(ATS)
#21: LIGHTING SYSTEM, INTERIOR,
OFFICE BUILDING
#22: DISTRIBUTION PANEL
#23: GENERATOR, GAS OR
GASOLINE
#24: INCANDESCENT LIGHTING
FIXTURE
COUNTRYSIDE LIFT
1975 NORTH BRIDGE STREET
YORKVILLE ILLINOIS EMG PROJECT NO: 122700.17R000-023.366
#25: STORM WATER LIFT STATION
#26: SECONDARY TRANSFORMER
#27: HIGH PRESSURE SODIUM
LIGHTING FIXTURE
#28: MOTOR CONTROL CENTER W/
MAIN BREAKER, 3-PHASE
#29: FIRE EXTINGUISHER
#30: INTERIOR DOOR, ALUMINUM
COUNTRYSIDE LIFT
1975 NORTH BRIDGE STREET
YORKVILLE ILLINOIS EMG PROJECT NO: 122700.17R000-023.366
#31: INTERIOR CEILING FINISH,
GYPSUM BOARD/PLASTER
#32: INTERIOR FLOOR FINISH,
CONCRETE
#33: INTERIOR WALL FINISH,
CONCRETE/MASONRY
COUNTRYSIDE LIFT EMG PROJECT NO.: 122700.17R000-023.366
Appendix B:
Site Plan
Site Plan
Project Name:
Countryside Lift
Project Number:
122700.17R000-023.366
Source:
Google Earth
On-Site Date:
May 23, 2017
COUNTRYSIDE LIFT EMG PROJECT NO.: 122700.17R000-023.366
Appendix C:
Pre-Survey Questionnaire
THE PRE-SURVEY QUESTIONNARE WAS NOT
RETURNED TO EMG
COUNTRYSIDE LIFT EMG PROJECT NO.: 122700.17R000-023.366
Appendix D:
ADA Checklist
Page 1 of 4
Date Completed: June 6, 2017
Property Name: Countryside Lift
EMG Project Number: 122700.17R000-023.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Public Works Garage
610 Tower Lane
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-024.366 September 13, 2017 May 22, 2017
FACILITY CONDITION ASSESSMENT
PUBLIC WORKS GARAGE EMG PROJECT NO.: 122700.17R000-024.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
PUBLIC WORKS GARAGE EMG PROJECT NO.: 122700.17R000-024.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 610 Tower Lane, Yorkville, IL 60560
Year Constructed/Renovated: 1996
Current Occupants: City of Yorkville
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Garage
Site Area: 0.1 acres
Building Area: 1700 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: Included in Public Works Office and Garage Report
Building Construction: Conventional wood frame structure on concrete slab
Roof Construction: Gabled roofs with metal roof finish
Exterior Finishes: Metal Siding
Heating, Ventilation and Air Conditioning: Suspended gas unit heaters
Fire and Life/Safety: Extinguishers
Dates of Visit: May 22, 2017
On-Site Point of Contact (POC): Eric Dhuse
Assessment and Report Prepared by: Tammy Prusa
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Poor HVAC Poor
Structure Poor Plumbing --
Roof Poor Electrical Poor
Vertical Envelope Poor Elevators --
Interiors Poor Fire --
The following bullet points highlight the most significant short term and modernization recommendations:
▪ Installation of a complete fire suppression system
PUBLIC WORKS GARAGE EMG PROJECT NO.: 122700.17R000-024.366
2
www.EMGcorp.com p 800.733.0660
▪ Installation of a complete fire alarm system
▪ Interior floor repair
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in fair overall condition.
The property has had no major capital improvements. The property is less than 32 years old and has not required any major capital
improvements.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 7.2% Fair
PUBLIC WORKS GARAGE EMG PROJECT NO.: 122700.17R000-024.366
3
www.EMGcorp.com p 800.733.0660
Key Finding Metric
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 19.9% Poor
Current Replacement Value (CRV) 1,700 SF * $183.24 / SF = $311,508.00
Year 0 (Current Year) - Immediate Repairs (IR) $22,328.00
Years 1-10 – Replacement Reserves (RR) $61,871.00
Total Capital Needs $84,199.00
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
▪ Installation of a complete fire suppression system
▪ Installation of a complete fire alarm system
▪ Interior floor repair
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
PUBLIC WORKS GARAGE EMG PROJECT NO.: 122700.17R000-024.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: ADA Checklist
PUBLIC WORKS GARAGE EMG PROJECT NO.: 122700.17R000-024.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
PUBLIC WORKS GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-024.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: LEFT ELEVATION
#3: REAR ELEVATION
#4: RIGHT ELEVATION
#5: FOUNDATIONS, CONCRETE
SLAB-ON-GRADE
#6: CRACKING THROUGHOUT
CONCRETE SLAB-ON-GRADE
PUBLIC WORKS GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-024.366
www.EMGcorp.com p 800.733.0660
#7: ROOF, METAL
#8: SIDING PEELING OFF LEFT
GARAGE ON SOUTH ELEVATION
#9: DAMAGE TO SIDING ON EAST
ELEVATION OF BUILDING
#10: EXTERIOR WALL, ALUMINUM
SIDING
#11: EXTERIOR DOOR, STEEL
#12: OVERHEAD DOOR, ALUMINUM
ROLL-UP
PUBLIC WORKS GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-024.366
www.EMGcorp.com p 800.733.0660
#13: UNIT HEATER, NATURAL GAS
#14: AIR COMPRESSOR
#15: FUEL STORAGE TANK
#16: INCANDESCENT LIGHTING
FIXTURE
#17: INCANDESCENT LIGHTING
FIXTURE, BASIC
#18: DISTRIBUTION PANEL
PUBLIC WORKS GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-024.366
www.EMGcorp.com p 800.733.0660
#19: 8-BULB FLUORESCENT
LIGHTING FIXTURE, HIGH BAY
#20: FIRE EXTINGUISHER
#21: DAMAGE TO INTERIOR WALL ON
EAST ELEVATION OF BUILDING
#22: INTERIOR WALL, WOOD
#23: FENCES & GATES, CHAIN LINK
PUBLIC WORKS GARAGE EMG PROJECT NO.: 122700.17R000-024.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Public Works Garage
Project Number:
122700.17R000-024.366
Source:
Google Earth
On-Site Date:
May 22, 2017
PUBLIC WORKS GARAGE EMG PROJECT NO.: 122700.17R000-024.366
www.EMGcorp.com p 800.733.0660
Appendix C:
ADA Checklist
Page 1 of 4
Date Completed: June 6, 2017
Property Name: Public Works Garage
EMG Project Number: 122700.17R000-024.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
PUBLIC WORKS LIFT STATION
101 BRUELL STREET
YORKVILLE, ILLINOIS 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-025.366 June 21, 2017 May 23, 2017
FACILITY CONDITION ASSESSMENT
BRUELL LIFT STATION EMG PROJECT NO.: 122700.17R000-025.366
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
BRUELL LIFT STATION EMG PROJECT NO.: 122700.17R000-025.366
1
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 101 Bruell Street, Yorkville, IL 60560
Year Constructed/Renovated: 2005
Current Occupants: City of Yorkville
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Lift Station
Site Area: 0.1 acres
Building Area: 1,200 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: Street parking with driveway
Building Construction: Masonry bearing walls and wood-framed roofs
Roof Construction: Gabled roofs with asphalt shingles
Exterior Finishes: Brick Veneer
Heating, Ventilation and Air Conditioning: Suspended electric unit heaters
Fire and Life/Safety: Smoke detectors, alarms, strobes, extinguishers, pull stations, and exit signs
Dates of Visit: May 23, 2017
On-Site Point of Contact (POC): Eric Dhuse
Assessment and Report Prepared by: Tammy Prusa
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer
For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC Fair
Structure Good Plumbing --
Roof Fair Electrical Fair
Vertical Envelope Good Elevators --
BRUELL LIFT STATION EMG PROJECT NO.: 122700.17R000-025.366
2
Systemic Condition Summary
Interiors Fair Fire Good
The following bullet points highlight the most significant short term and modernization recommendations:
Seal and stripe asphalt pavement
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in fair overall condition.
The property has had no major capital improvements. The property is less than 12 years old and has not required any major capital
improvements.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
BRUELL LIFT STATION EMG PROJECT NO.: 122700.17R000-025.366
3
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.0% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 52.3% Poor
Current Replacement Value (CRV) 1,200 SF * $183.24 / SF = $219,888.00
Year 0 (Current Year) - Immediate Repairs (IR) $0.00
Years 1-10 – Replacement Reserves (RR) $115,015.00
Total Capital Needs $115,015.00
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
There were no short term or modernization recommendations
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
BRUELL LIFT STATION EMG PROJECT NO.: 122700.17R000-025.366
4
2 Appendices
Appendix A: Photographic Record
Appendix B: Site and Floor Plans
Appendix C: Pre-Survey Questionnaire
Appendix D: ADA Checklist
BRUELL LIFT STATION EMG PROJECT NO.: 122700.17R000-025.366
Appendix A:
Photographic Record
PUBLIC WORKS LIFT STATION BRUELL
101 BRUELL STREET
YORKVILLE ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-025.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: LEFT ELEVATION
#3: REAR ELEVATION
#4: RIGHT ELEVATION
#5: PEDESTRIAN PAVEMENT,
SIDEWALK, CONCRETE
#6: DRIVEWAY, ASPHALT
PAVEMENT
PUBLIC WORKS LIFT STATION BRUELL
101 BRUELL STREET
YORKVILLE ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-025.366
www.EMGcorp.com p 800.733.0660
#7: DRIVEWAY, ASPHALT
PAVEMENT
#8: ROOF, ASPHALT SHINGLE
#9: EXTERIOR WALL, CONCRETE
BLOCK (CMU)
#10: EXTERIOR WALL, BRICK VENEER
#11: EXTERIOR DOOR, STEEL
#12: WINDOW, ALUMINUM DOUBLE-
GLAZED
PUBLIC WORKS LIFT STATION BRUELL
101 BRUELL STREET
YORKVILLE ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-025.366
www.EMGcorp.com p 800.733.0660
#13: OVERHEAD DOOR, ALUMINUM
ROLL-UP
#14: EXHAUST FAN, PROPELLER
#15: UNIT HEATER, ELECTRIC
#16: EMERGENCY EYE WASH &
SHOWER STATION
#17: WATER STORAGE TANK
#18: SINK, PORCELAIN ENAMEL,
CAST IRON
PUBLIC WORKS LIFT STATION BRUELL
101 BRUELL STREET
YORKVILLE ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-025.366
www.EMGcorp.com p 800.733.0660
#19: BACKFLOW PREVENTER
#20: LIGHTING SYSTEM, INTERIOR,
OFFICE BUILDING
#21: GENERATOR, GAS OR
GASOLINE
#22: DISTRIBUTION PANEL
#23: INCANDESCENT LIGHTING
FIXTURE
#24: MOTOR CONTROL CENTER W/
MAIN BREAKER, 3-PHASE
PUBLIC WORKS LIFT STATION BRUELL
101 BRUELL STREET
YORKVILLE ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-025.366
www.EMGcorp.com p 800.733.0660
#25: HIGH PRESSURE SODIUM
LIGHTING FIXTURE
#26: DISTRIBUTION PANEL
#27: STORM WATER LIFT STATION
CONTROLLER
#28: SECONDARY TRANSFORMER
#29: AUTOMATIC TRANSFER SWITCH
#30: FIRE EXTINGUISHER
PUBLIC WORKS LIFT STATION BRUELL
101 BRUELL STREET
YORKVILLE ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-025.366
www.EMGcorp.com p 800.733.0660
#31: EXIT LIGHTING FIXTURE
#32: INTERIOR CEILING FINISH,
GYPSUM BOARD/PLASTER
#33: INTERIOR FLOOR FINISH,
CONCRETE
#34: INTERIOR STAIRS, CONCRETE
#35: INTERIOR STAIR/RAMP RAILS,
METAL
#36: INTERIOR WALL FINISH,
CONCRETE/MASONRY
BRUELL LIFT STATION EMG PROJECT NO.: 122700.17R000-025.366
Appendix B:
Site Plan
Site Plan
Project Name:
Public Works Lift Station
Project Number:
122700.17R000-025.366
Source:
Google Earth
On-Site Date:
May 23, 2017
BRUELL LIFT STATION EMG PROJECT NO.: 122700.17R000-025.366
Appendix C:
Pre-Survey Questionnaire
Page 1 of 4
Date Completed: June 6, 2017
Property Name: Public Works Lift Station
EMG Project Number: 122700.17R000-025.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
BRUELL LIFT STATION EMG PROJECT NO.: 122700.17R000-025.366
Appendix D:
ADA Checklist
THE PRE-SURVEY QUESTIONNARE WAS NOT
RETURNED TO EMG
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Treatment Facility Well 3 and 4
610 Tower Lane
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 bchampion@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-034.366 June 22, 2017 May 22, 2017
FACILITY CONDITION ASSESSMENT
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO.: 122700.17R000-034.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO.: 122700.17R000-034.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 610 Tower Lane, Yorkville, Illinois 60560
Year Constructed/Renovated: 2001
Current Occupants: City of Yorkville
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Treatment Facility
Site Area: 0.04 acres
Building Area: 3,900 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: Included in Public Works Office and Garage report
Building Construction: Masonry bearing walls and wood-framed roofs
Roof Construction: Gabled roofs with asphalt shingles
Exterior Finishes: Brick Veneer
Heating, Ventilation and Air Conditioning: Ductless split-systems and suspended electric unit heaters
Fire and Life/Safety: Smoke detectors, alarms, strobes, extinguishers, pull stations, alarm panel, and exit signs
Dates of Visit: May 22, 2017
On-Site Point of Contact (POC): Eric Dhuse
Assessment and Report Prepared by: Tammy Prusa
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer
For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC Fair
Structure Good Plumbing Fair
Roof Fair Electrical Fair
Vertical Envelope Fair Elevators --
Interiors Fair Fire Fair
The following bullet points highlight the most significant short term and modernization recommendations:
Installation of a complete fire suppression system
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO.: 122700.17R000-034.366
2
www.EMGcorp.com p 800.733.0660
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in fair overall condition.
The property has had no major capital improvements. The property is less than 20 years old and has not required any major capital
improvements.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 4.4% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 30.2% Poor
Current Replacement Value (CRV) 3,900 SF * $183.24 / SF = $714,636.00
Year 0 (Current Year) - Immediate Repairs (IR) $31,195.00
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO.: 122700.17R000-034.366
3
www.EMGcorp.com p 800.733.0660
Key Finding Metric
Years 1-10 – Replacement Reserves (RR) $215,662.00
Total Capital Needs $246,857.00
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Installation of a complete fire suppression system
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO.: 122700.17R000-034.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: ADA Checklist
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO.: 122700.17R000-034.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO: 122700.17R000-034.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: LEFT ELEVATION
#3: REAR ELEVATION
#4: RIGHT ELEVATION
#5: ROOF, ASPHALT SHINGLE
#6: EXTERIOR WALL, CONCRETE
BLOCK (CMU)
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO: 122700.17R000-034.366
www.EMGcorp.com p 800.733.0660
#7: EXTERIOR WALL, BRICK VENEER
#8: OVERHEAD DOOR, ALUMINUM
ROLL-UP
#9: WINDOW, ALUMINUM DOUBLE-
GLAZED
#10: EXTERIOR DOOR, WOOD SOLID-
CORE
#11: BOOSTER PUMP
#12: EXHAUST FAN, CENTRIFUGAL
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO: 122700.17R000-034.366
www.EMGcorp.com p 800.733.0660
#13: CONTROL SYSTEM
#14: CONTROL SYSTEM
#15: BOOSTER PUMP
#16: DUCTLESS SPLIT SYSTEM,
SINGLE ZONE
#17: DUCTLESS SPLIT SYSTEM,
SINGLE ZONE
#18: UNIT HEATER, ELECTRIC
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO: 122700.17R000-034.366
www.EMGcorp.com p 800.733.0660
#19: EXHAUST FAN, PROPELLER
#20: RESIDENTIAL FIXTURES,
CEILING FAN
#21: SERVICE SINK, FLOOR
#22: WATER STORAGE TANK
#23: EMERGENCY EYE WASH AND
SHOWER STATION
#24: BOOSTER PUMP
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO: 122700.17R000-034.366
www.EMGcorp.com p 800.733.0660
#25: WATER STORAGE TANK
#26: WATER STORAGE TANK
#27: WATER HEATER, ELECTRIC,
RESIDENTIAL
#28: BACKFLOW PREVENTER
#29: HIGH PRESSURE SODIUM
LIGHTING FIXTURE
#30: MOTOR CONTROL CENTER W/
MAIN BREAKER
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO: 122700.17R000-034.366
www.EMGcorp.com p 800.733.0660
#31: COMPACT FLUORESCENT
LIGHTING FIXTURE
#32: LIGHTING SYSTEM, INTERIOR,
OFFICE BUILDING
#33: EXIT LIGHTING FIXTURE
#34: FIRE EXTINGUISHER
#35: FIRE ALARM CONTROL PANEL,
ADDRESSABLE
#36: INTERIOR DOOR, STEEL
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO: 122700.17R000-034.366
www.EMGcorp.com p 800.733.0660
#37: INTERIOR FLOOR FINISH,
CONCRETE
#38: INTERIOR WALL FINISH,
CONCRETE/MASONRY
#39: INTERIOR CEILING FINISH,
GYPSUM BOARD/PLASTER
#40: KITCHEN CABINET, BASE AND
WALL SECTION, WOOD
#41: SINK, EPOXY RESIN,
LABORATORY
#42: KITCHEN CABINET, BASE AND
WALL SECTION, WOOD
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO.: 122700.17R000-034.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Treatment Facility Well 3 and 4
Project Number:
122700.17R000-034.366
Source:
Google Earth
On-Site Date:
May 22, 2017
TREATMENT FACILITY WELL 3 AND 4 EMG PROJECT NO.: 122700.17R000-034.366
www.EMGcorp.com p 800.733.0660
Appendix C:
ADA Checklist
Page 1 of 4
Date Completed: June 6, 2017
Property Name: Treatment Facilty Well 3 and 4
EMG Project Number: 122700.17R000-034.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
3
Does the width between railings appear at
least 36 inches? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms (cont.) Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Treatment Facility Well 7
2224 Tremont
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-035.366 June 23, 2017 May 24, 2017
FACILITY CONDITION ASSESSMENT
TREATMENT FACILITY WELL 7 EMG PROJECT NO.: 122700.17R000-035.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
TREATMENT FACILITY WELL 7 EMG PROJECT NO.: 122700.17R000-035.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 2224 Tremont, Yorkville, Illinois 60560
Year Constructed/Renovated: 2004
Current Occupants: City of Yorkville
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Water Treatment Facility
Site Area: 1.4 acres
Building Area: 3,200 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: 0 marked spaces in open lots
Building Construction: Masonry bearing walls and wood-framed roofs
Roof Construction: Gabled roofs with asphalt shingles
Exterior Finishes: Brick Veneer
Heating, Ventilation and Air Conditioning: Ceiling Fans, ductless split-system, suspended electric unit heaters
Fire and Life/Safety: Smoke detectors, alarms, strobes, extinguishers, pull stations, alarm panel, and exit signs
Dates of Visit: May 24, 2017
On-Site Point of Contact (POC): Eric Dhuse
Assessment and Report Prepared by: Tammy Prusa
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer
For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC Fair
Structure Good Plumbing Fair
Roof Fair Electrical Fair
Vertical Envelope Good Elevators --
Interiors Fair Fire Good
TREATMENT FACILITY WELL 7 EMG PROJECT NO.: 122700.17R000-035.366
2
www.EMGcorp.com p 800.733.0660
The following bullet points highlight the most significant short term and modernization recommendations:
Installation of a complete fire suppression system
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in fair overall condition.
The property has had no major capital improvements. The property is less than 13 years old and has not required any major capital
improvements.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 4.4% Good
TREATMENT FACILITY WELL 7 EMG PROJECT NO.: 122700.17R000-035.366
3
www.EMGcorp.com p 800.733.0660
Key Finding Metric
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 26.8% Poor
Current Replacement Value (CRV) 3,200 SF * $183.24 / SF = $586,368.00
Year 0 (Current Year) - Immediate Repairs (IR) $25,596.00
Years 1-10 – Replacement Reserves (RR) $157,269.00
Total Capital Needs $182,865.00
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Installation of a complete fire suppression system
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
TREATMENT FACILITY WELL 7 EMG PROJECT NO.: 122700.17R000-035.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: ADA Checklist
TREATMENT FACILITY WELL 7 EMG PROJECT NO.: 122700.17R000-035.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
TREATMENT FACILITY WELL 7
2224 TREMONT
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-035.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: LEFT ELEVATION
#3: REAR ELEVATION
#4: RIGHT ELEVATION
#5: PEDESTRIAN PAVEMENT,
SIDEWALK, CONCRETE
#6: PARKING LOTS, ASPHALT
PAVEMENT
TREATMENT FACILITY WELL 7
2224 TREMONT
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-035.366
www.EMGcorp.com p 800.733.0660
#7: FENCES & GATES, CHAIN LINK
#8: ROOF, ASPHALT SHINGLE
#9: EXTERIOR WALL, CONCRETE
BLOCK (CMU)
#10: EXTERIOR WALL, BRICK VENEER
#11: WINDOW, ALUMINUM DOUBLE-
GLAZED
#12: EXTERIOR DOOR, STEEL
TREATMENT FACILITY WELL 7
2224 TREMONT
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-035.366
www.EMGcorp.com p 800.733.0660
#13: OVERHEAD DOOR, ALUMINUM
ROLL-UP
#14: DUCTLESS SPLIT SYSTEM,
SINGLE ZONE
#15: DUCTLESS SPLIT SYSTEM,
SINGLE ZONE
#16: RESIDENTIAL FIXTURES,
CEILING FAN
#17: UNIT HEATER, ELECTRIC
#18: BUILDING AUTOMATION SYSTEM
(HVAC CONTROLS)
TREATMENT FACILITY WELL 7
2224 TREMONT
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-035.366
www.EMGcorp.com p 800.733.0660
#19: BACKFLOW PREVENTER
#20: WATER HEATER, ELECTRIC,
RESIDENTIAL
#21: WATER FLOW METER
#22: EMERGENCY EYE WASH &
SHOWER STATION,
#23: WATER STORAGE TANK, UNIT 1
#24: WATER STORAGE TANK, UNIT 2
TREATMENT FACILITY WELL 7
2224 TREMONT
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-035.366
www.EMGcorp.com p 800.733.0660
#25: WATER STORAGE TANK, UNIT 3
#26: BOOSTER PUMP
#27: LAVATORY, VITREOUS CHINA
#28: TOILET, FLUSH TANK (WATER
CLOSET)
#29: BUILDING/MAIN SWITCHGEAR
#30: SECONDARY TRANSFORMER,
DRY
TREATMENT FACILITY WELL 7
2224 TREMONT
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-035.366
www.EMGcorp.com p 800.733.0660
#31: INCANDESCENT LIGHTING
FIXTURE, BASIC
#32: MOTOR CONTROL CENTER W/
MAIN BREAKER, 3-PHASE
#33: HIGH PRESSURE SODIUM
LIGHTING FIXTURE
#34: DISTRIBUTION PANEL
#35: LIGHTING SYSTEM, INTERIOR
#36: TRANSFER SWITCH, AUTOMATIC
(ATS)
TREATMENT FACILITY WELL 7
2224 TREMONT
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-035.366
www.EMGcorp.com p 800.733.0660
#37: FIRE EXTINGUISHER
#38: EXIT LIGHTING FIXTURE
#39: FIRE ALARM SYSTEM
#40: INTERIOR WALL FINISH,
CONCRETE BLOCK
#41: INTERIOR CEILING FINISH,
GYPSUM BOARD
#42: INTERIOR FLOOR FINISH,
CONCRETE
TREATMENT FACILITY WELL 7
2224 TREMONT
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-035.366
www.EMGcorp.com p 800.733.0660
#43: INTERIOR DOOR, ALUMINUM
#44: INTERIOR WINDOW
#45: SERVICE SINK, FLOOR
#46: CABINET, BASE AND WALL
SECTION, WOOD
#47: SINK, EPOXY RESIN,
LABORATORY
TREATMENT FACILITY WELL 7 EMG PROJECT NO.: 122700.17R000-035.366
Appendix B:
Site Plan
Site Plan
Project Name:
Treatment Facility Well 7
Project Number:
122700.17R000-035.366
Source:
Google Earth
On-Site Date:
May 24, 2017
TREATMENT FACILITY WELL 7 EMG PROJECT NO.: 122700.17R000-035.366
Appendix C:
ADA Checklist
Page 1 of 4
Date Completed: June 7, 2017
Property Name: Treatment Facility Well 7
EMG Project Number: 122700.17R000-035.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X No marked parking spaces.
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Public Works Garage (Frame Building)
185 Wolf Street
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-041.322 July 18, 2017 June 26, 2017
FACILITY CONDITION ASSESSMENT
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1. Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
1.3. Special Issues and Follow-Up Recommendations ...................................................................... 3
1.4. Opinions of Probable Cost .......................................................................................................... 3
1.4.1. Methodology ................................................................................................................................ 4
1.4.2. Immediate Repairs ...................................................................................................................... 4
1.4.3. Replacement Reserves ............................................................................................................... 4
2. Purpose and Scope .............................................................................................................................. 5
2.1. Purpose ....................................................................................................................................... 5
2.2. Scope .......................................................................................................................................... 6
2.3. Personnel Interviewed ................................................................................................................. 6
2.4. Documentation Reviewed ........................................................................................................... 7
2.5. Pre-Survey Questionnaire ........................................................................................................... 7
2.6. Weather Conditions ..................................................................................................................... 7
3. Accessibility and Property Research ................................................................................................. 8
3.1. ADA Accessibility ........................................................................................................................ 8
3.2. Municipal Information, Flood Zone and Seismic Zone ................................................................ 8
4. Existing Building Assessment ............................................................................................................ 9
4.1. Unit or Space Types .................................................................................................................... 9
4.2. Inaccessible Areas or Key Spaces Not Observed ...................................................................... 9
5. Site Improvements ............................................................................................................................. 10
5.1. Utilities ....................................................................................................................................... 10
5.2. Parking, Paving, and Sidewalks ................................................................................................ 10
5.3. Drainage Systems and Erosion Control .................................................................................... 11
5.4. Topography and Landscaping ................................................................................................... 12
5.5. General Site Improvements ....................................................................................................... 12
6. Building Architectural and Structural Systems ............................................................................... 14
6.1. Foundations ............................................................................................................................... 14
6.2. Superstructure ........................................................................................................................... 14
6.3. Roofing ...................................................................................................................................... 14
6.4. Exterior Walls ............................................................................................................................ 15
6.5. Exterior and Interior Stairs ......................................................................................................... 16
6.6. Exterior Windows and Doors ..................................................................................................... 16
6.7. Patio, Terrace, and Balcony ...................................................................................................... 17
7. Building Mechanical and Plumbing Systems .................................................................................. 18
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC) ..................................................... 18
7.2. Building Plumbing and Domestic Hot Water ............................................................................. 19
7.3. Building Gas Distribution ........................................................................................................... 20
7.4. Building Electrical ...................................................................................................................... 20
7.5. Building Elevators and Conveying Systems .............................................................................. 21
7.6. Fire Protection and Security Systems ....................................................................................... 21
7.7. Life Support Systems ................................................................................................................ 22
8. Interior Spaces .................................................................................................................................... 23
8.1. Interior Finishes ......................................................................................................................... 23
8.2. Commercial Kitchen & Laundry Equipment .............................................................................. 24
9. Other Structures ................................................................................................................................. 25
10. Certification ......................................................................................................................................... 26
11. Appendices ......................................................................................................................................... 27
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
1
www.EMGcorp.com p 800.733.0660
1. Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 185 Wolf Street, Yorkville, IL 60560
Year Constructed/Renovated: 2008
Current Occupants: City of Yorkville
Percent Utilization: 100%
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Office, Garage
Site Area: 2.4 acres
Building Area: 10,600 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of
Spaces: 32 spaces in open lots.
Building Construction: Steel frame with concrete-topped metal decks.
Roof Construction: Sloped roofing with metal finish.
Exterior Finishes: Metal Siding
Heating, Ventilation & Air
Conditioning: Condensing unit, Furnace, Ceiling Fans, and Unit Heaters.
Fire and Life/Safety: Smoke detectors, strobes, extinguishers, exit signs, and carbon
monoxide detectors.
Dates of Visit: June 26, 2017
On-Site Point of Contact (POC): Tony Hule
Assessment and Report
Prepared by: Tammy Prusa
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC Good
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
2
www.EMGcorp.com p 800.733.0660
Systemic Condition Summary
Structure Good Plumbing Fair
Roof Good Electrical Good
Vertical Envelope Good Elevators --
Interiors Fair Fire --
The following bullet points highlight the most significant short term and modernization recommendations:
Installation of a complete Fire Alarm System
Installation of a complete Sprinkler System
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in fair overall condition.
The property has had no major capital improvements. The property is less than 9 years old and has not required any major capital
improvements.
1.2. F acility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
Fci Condition
Rating Definition Percentage
Value
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
3
www.EMGcorp.com p 800.733.0660
Good In new or well-maintained condition, with no visual evidence
of wear, soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and
functioning condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its
useful or serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal
is now necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 5.9% Fair
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 2.8% Good
Current Replacement Value (CRV) 10,600 SF * 183.24 / SF = $1,832,371
Year 0 (Current Year) - Immediate Repairs (IR) $109,797
Years 1-10 – Replacement Reserves (RR) $53,136
Total Capital Needs $162,933
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Installation of a complete Fire Alarm System
Installation of a complete Sprinkler System
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
1.3. Special Issues and Follow-Up Recommendations
As part of the FCA, a limited assessment of accessible areas of the building(s) was performed to determine the presence of fungal
growth, conditions conducive to fungal growth, and/or evidence of moisture. Property personnel were interviewed concerning any
known or suspected fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Sampling is not a part of this
assessment.
There are no visual indications of the presence of fungal growth, conditions conducive to fungal growth, or evidence of moisture in
representative readily accessible areas of the property.
1.4. Opinions of Probable Cost
Cost estimates are attached at the front of this report (following the cover page).
These estimates are based on Invoice or Bid Document/s provided either by the Owner/facility and construction costs developed by
construction resources such as R.S. Means and Marshall & Swift, EMG’s experience with past costs for similar properties, city cost
indexes, and assumptions regarding future economic conditions.
Opinions of probable costs should only be construed as preliminary, order of magnitude budgets. Actual costs most probably will vary
from the consultant’s opinions of probable costs depending on such matters as type and design of suggested remedy, quality of
materials and installation, manufacturer and type of equipment or system selected, field conditions, whether a physical deficiency is
repaired or replaced in whole, phasing of the work (if applicable), quality of contractor, quality of project management exercised, market
conditions, and whether competitive pricing is solicited, etc. ASTM E2018-08 recognizes that certain opinions of probable costs cannot
be developed within the scope of this guide without further study. Opinions of probable cost for further study should be included in the
FCA.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
4
www.EMGcorp.com p 800.733.0660
1.4.1. Methodology
Based upon site observations, research, and judgment, along with referencing Expected Useful Life (EUL) tables from various industry
sources, EMG opines as to when a system or component will most probably necessitate replacement. Accurate historical replacement
records, if provided, are typically the best source of information. Exposure to the elements, initial quality and installation, extent of use,
the quality and amount of preventive maintenance exercised, etc., are all factors that impact the effective age of a system or
component. As a result, a system or component may have an effective age that is greater or less than its actual chronological age.
The Remaining Useful Life (RUL) of a component or system equals the EUL less its effective age. Projections of Remaining Useful Life
(RUL) are based on continued use of the Property similar to the reported past use. Significant changes in occupants and/or usage may
affect the service life of some systems or components.
Where quantities could not be derived from an actual take-off, lump sum costs or allowances are used. Estimated costs are based on
professional judgment and the probable or actual extent of the observed defect, inclusive of the cost to design, procure, construct and
manage the corrections.
1.4.2. Immediate Repairs
Immediate repairs are opinions of probable costs that require immediate action as a result of: (1) material existing or potential unsafe
conditions, (2) material building or fire code violations, or (3) conditions that, if not addressed, have the potential to result in, or
contribute to, critical element or system failure within one year or will most probably result in a significant escalation of its remedial cost.
1.4.3. Replacement Reserves
Replacement Reserves are for recurring probable expenditures, which are not classified as operation or maintenance expenses. The
replacement reserves should be budgeted for in advance on an annual basis. Replacement Reserves are reasonably predictable both
in terms of frequency and cost. However, Replacement Reserves may also include components or systems that have an
indeterminable life but, nonetheless, have a potential for failure within an estimated time period.
Replacement Reserves exclude systems or components that are estimated to expire after the reserve term and are not considered
material to the structural and mechanical integrity of the subject property. Furthermore, systems and components that are not deemed
to have a material effect on the use of the Property are also excluded. Costs that are caused by acts of God, accidents, or other
occurrences that are typically covered by insurance, rather than reserved for, are also excluded.
Replacement costs are solicited from ownership/property management, EMG’s discussions with service companies, manufacturers'
representatives, and previous experience in preparing such schedules for other similar facilities. Costs for work performed by the
ownership’s or property management’s maintenance staff are also considered.
EMG’s reserve methodology involves identification and quantification of those systems or components requiring capital reserve funds
within the assessment period. The assessment period is defined as the effective age plus the reserve term. Additional information
concerning system’s or component’s respective replacement costs (in today's dollars), typical expected useful lives, and remaining
useful lives were estimated so that a funding schedule could be prepared. The Replacement Reserves Schedule presupposes that all
required remedial work has been performed or that monies for remediation have been budgeted for items defined in the Immediate
Repair Cost Estimate.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
5
www.EMGcorp.com p 800.733.0660
2. Purpose and Scope
2.1. Purpose
EMG was retained by the client to render an opinion as to the Property’s current general physical condition on the day of the site visit.
Based on the observations, interviews and document review outlined below, this report identifies significant deferred maintenance
issues, existing deficiencies, and material code violations of record at municipal offices, which affect the Property’s use. Opinions are
rendered as to its structural integrity, building system condition and the Property’s overall condition. The report also notes building
systems or components that have realized or exceeded their typical expected useful lives.
CONDITIONS:
The physical condition of building systems and related components are typically defined as being in one of five conditions: Excellent,
Good, Fair, Poor, Failed or a combination thereof. For the purposes of this report, the following definitions are used:
Excellent = New or very close to new; component or system typically has been installed within the past year, sound and
performing its function. Eventual repair or replacement will be required when the component or system either
reaches the end of its useful life or fails in service.
Good = Satisfactory as-is. Component or system is sound and performing its function, typically within the first third
of its lifecycle. However, it may show minor signs of normal wear and tear. Repair or replacement will be
required when the component or system either reaches the end of its useful life or fails in service.
Fair = Showing signs of wear and use but still satisfactory as-is, typically near the median of its estimated useful
life. Component or system is performing adequately at this time but may exhibit some signs of wear,
deferred maintenance, or evidence of previous repairs. Repair or replacement will be required due to the
component or system’s condition and/or its estimated remaining useful life.
Poor = Component or system is significantly aged, flawed, functioning intermittently or unreliably; displays obvious
signs of deferred maintenance; shows evidence of previous repair or workmanship not in compliance with
commonly accepted standards; has become obsolete; or exhibits an inherent deficiency. The present
condition could contribute to or cause the deterioration of contiguous elements or systems. Either full
component replacement is needed or repairs are required to restore to good condition, prevent premature
failure, and/or prolong useful life.
Failed
= Component or system has ceased functioning or performing as intended. Replacement, repair, or other
significant corrective action is recommended or required.
Not Applicable
= Assigning a condition does not apply or make logical sense, most commonly due to the item in question not
being present.
FORMAT OF THE BODY OF THE REPORT:
Throughout sections 5 through 9 of this report, each report section will typically contain three subsections organized in the following
sequence:
A descriptive table (and/or narrative), which identifies the components assessed, their condition, and other key data points.
A simple bulleted list of Anticipated Lifecycle Replacements, which lists components and assets typically in Excellent, Good, or Fair
condition at the time of the assessment but that will require replacement or some other attention once aged past their estimated
useful life. These listed components are typically included in the associated inventory database with costs identified and budgeted
beyond the first several years.
A bulleted cluster of Actions/Comments, which include more detailed narratives describing deficiencies, recommended repairs, and
short term replacements. The assets and components associated with these bullets are/were typically problematic and in Poor or
Failed condition at the time of the assessment, with corresponding costs included within the first few years.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
6
www.EMGcorp.com p 800.733.0660
PLAN TYPES:
Each line item in the cost database is assigned a Plan Type, which is the primary reason or rationale for the recommended
replacement, repair, or other corrective action. This is the “why” part of the equation. A cost or line item may commonly have more
than one applicable Plan Type; however, only one Plan Type will be assigned based on the “best” fit, typically the one with the greatest
significance. The following Plan Types are listed in general weighted order of importance:
Safety = An observed or reported unsafe condition that if left unaddressed could result in an injury; a system or
component that presents a potential liability risk.
Performance/Integrity = Component or system has failed, is almost failing, performs unreliably, does not perform as intended,
and/or poses a risk to overall system stability.
Accessibility = Does not meet ADA, UFAS, and/or other handicap accessibility requirements.
Environmental = Improvements to air or water quality, including removal of hazardous materials from the building or
site.
Modernization/Adaptation
= Conditions, systems, or spaces that need to be upgraded in appearance or function to meet current
standards, facility usage, or client/occupant needs.
Lifecycle/Renewal
= Any component or system in which future repair or replacement is anticipated beyond the next several
years and/or is of minimal substantial early-term consequence.
2.2. Scope
The standard scope of the Facility Condition Assessment includes the following:
Visit the Property to evaluate the general condition of the building and site improvements, review available construction documents in
order to familiarize ourselves with, and be able to comment on, the in-place construction systems, life safety, mechanical, electrical,
and plumbing systems, and the general built environment.
Identify those components that are exhibiting deferred maintenance issues and provide cost estimates for Immediate Costs and
Replacement Reserves based on observed conditions, maintenance history and industry standard useful life estimates. This will
include the review of documented capital improvements completed within the last five-year period and work currently contracted for, if
applicable.
Provide a full description of the Property with descriptions of in-place systems and commentary on observed conditions.
Provide a general statement of the subject Property’s compliance to Title III of the Americans with Disabilities Act. This will not
constitute a full ADA survey, but will help identify exposure to issues and the need for further review.
Perform a limited assessment of accessible areas of the building(s) for the presence of fungal growth, conditions conducive to fungal
growth, and/or evidence of moisture. EMG will also interview Project personnel regarding the presence of any known or suspected
fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Potentially affected areas will be photographed.
Sampling will not be considered in routine assessments.
List the current utility service providers.
Review maintenance records and procedures with the in-place maintenance personnel.
Observe a representative sample of the interior spaces/units, including vacant spaces/units, in order to gain a clear understanding of
the property’s overall condition. Other areas to be observed include the exterior of the property, the roofs, interior common areas,
and the significant mechanical, electrical and elevator equipment rooms.
Provide recommendations for additional studies, if required, with related budgetary information.
Provide an Executive Summary at the beginning of this report.
2.3. Personnel Interviewed
The management were interviewed for specific information relating to the physical property, available maintenance procedures,
historical performance of key building systems and components, available drawings and other documentation. The following personnel
from the facility and government agencies were interviewed in the process of conducting the FCA:
Name and Title Organization Phone Number
Tony Hule City of Yorkville (630) 885-3569
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
7
www.EMGcorp.com p 800.733.0660
The FCA was performed with the assistance of Tony Hule, City of Yorkville, the onsite Point of Contact (POC), who was cooperative
and provided information that appeared to be accurate based upon subsequent site observations. The onsite contact is completely
knowledgeable about the subject property and answered most questions posed during the interview process. The POC’s management
involvement at the property has been for the past 14 years.
2.4. Documentation Reviewed
Prior to the FCA, relevant documentation was requested that could aid in the knowledge of the subject property’s physical
improvements, extent and type of use, and/or assist in identifying material discrepancies between reported information and observed
conditions. The review of submitted documents does not include comment on the accuracy of such documents or their preparation,
methodology, or protocol. The Documentation Request Form is provided in Appendix E.
Although Appendix E provides a summary of the documents requested or obtained, the following list provides more specific details
about some of the documents that were reviewed or obtained during the site visit.
No documents available.
2.5. Pre-Survey Questionnaire
A Pre-Survey Questionnaire was sent to the POC prior to the site visit, and was not returned. The questionnaire is included in Appendix
E.
2.6. Weather Conditions
June 26, 2017: Clear, with temperatures in the 70s (°F) and light winds.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
8
www.EMGcorp.com p 800.733.0660
3. Accessibility and Property Research
3.1. ADA Accessibility
Generally, Title III of the Americans with Disabilities Act (ADA) prohibits discrimination by entities to access and use of “areas of public
accommodations” and “commercial facilities” on the basis of disability. Regardless of its age, these areas and facilities must be
maintained and operated to comply with the Americans with Disabilities Act Accessibility Guidelines (ADAAG).
Buildings completed and occupied after January 26, 1992 are required to comply fully with the ADAAG. Existing facilities constructed
prior to this date are held to the lesser standard of compliance to the extent allowed by structural feasibility and the financial resources
available. As an alternative, a reasonable accommodation pertaining to the deficiency must be made.
During the FCA, a limited visual observation for ADA accessibility compliance was conducted. The scope of the visual observation was
limited to those areas set forth in EMG’s Abbreviated Accessibility Checklist provided in Appendix D of this report. It is understood by
the Client that the limited observations described herein does not comprise a full ADA Compliance Survey, and that such a survey is
beyond the scope of EMG’s undertaking. Only a representative sample of areas was observed and, other than as shown on the
Abbreviated Accessibility Checklist, actual measurements were not taken to verify compliance.
At a Garage/Office property, the areas considered as a public accommodation besides the site itself and parking, are the exterior
accessible route, the interior accessible route up to the tenant lease lines and the interior common areas, including the common area
restrooms.
The facility does not appear to be accessible with Title III of the Americans with Disabilities Act. Elements as defined by the ADAAG
that are not accessible as stated within the priorities of Title III, are as follows:
Parking
Adequate number of designated parking stalls and signage for vans are not provided.
Ramps
Existing exterior ramps and stairs are not equipped with the required handrails (each side).
Restrooms
Install grab bars in accessible stalls at 36” above the floor.
A full ADA Compliance Survey may reveal some aspects of the property that are not in compliance.
Corrections of these conditions should be addressed from a liability standpoint, but are not necessarily code violations. The Americans
with Disabilities Act Accessibility Guidelines concern civil rights issues as they pertain to the disabled and are not a construction code,
although many local jurisdictions have adopted the Guidelines as such. The cost to address the achievable items noted above is
included in the cost tables.
3.2. Municipal Information, Flood Zone and Seismic Zone
Not applicable
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
9
www.EMGcorp.com p 800.733.0660
4. Existing Building Assessment
4.1. Unit or Space Types
All 10,600 square feet of the building are occupied by a single occupant, City of Yorkville. The spaces are mostly a combination of
offices, supporting restrooms, garages.
4.2. Inaccessible Areas or Key Spaces Not Observed
The interior spaces were observed in order to gain a clear understanding of the property’s overall condition. Other areas accessed
included the site within the property boundaries, exterior of the property and the roof. All areas of the property were available for
observation during the site visit.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
10
www.EMGcorp.com p 800.733.0660
5. Site Improvements
5.1. Utilities
The following table identifies the utility suppliers and the condition and adequacy of the services.
Site Utilities
Utility Supplier Condition and Adequacy
Sanitary sewer City of Yorkville Good
Storm sewer Yorkville Department of Public Works Good
Domestic water City of Yorkville Good
Electric service ComEd Good
Natural gas service Nicor Good
Actions/Comments:
According to the POC, the utilities provided are adequate for the property. There are no unique, onsite utility systems such as
emergency electrical generators, septic systems, water or waste water treatment plants, or propane gas tanks.
5.2. Parking, Paving, and Sidewalks
Item Description
Main Ingress and Egress Wolf Street
Access from North
Additional Entrances N/A
Additional Access from N/A
Paving and Flatwork
Item Material Last Work Done Condition
Entrance Driveway Apron Asphalt 2008 Fair
Parking Lot Asphalt 2008 Fair
Drive Aisles None -- --
Service Aisles None -- --
Sidewalks Concrete 2008 Good
Curbs Concrete 2008 Fair
Site Stairs None -- --
Pedestrian Ramps None -- --
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
11
www.EMGcorp.com p 800.733.0660
Parking Count
Open Lot Carport Private Garage Subterranean
Garage
Freestanding Parking
Structure
23 -- -- -- -
Total Number of ADA Compliant Spaces 1
Number of ADA Compliant Spaces for Vans 0
Total Parking Spaces 23
Parking Ratio (Spaces/Apartments) --
Method of Obtaining Parking Count Physical count
Exterior Stairs
Location Material Handrails Condition
None -- -- --
Anticipated Lifecycle Replacements:
Asphalt seal coating
Asphalt pavement
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
5.3. Drainage Systems and Erosion Control
Drainage System and Erosion Control
System Exists At Site Condition
Surface Flow ☒ Good
Inlets ☐ --
Swales ☐ --
Detention pond ☐ --
Lagoons ☐ --
Ponds ☐ --
Underground Piping ☐ --
Pits ☐ --
Municipal System ☐ --
Dry Well ☐ --
Anticipated Lifecycle Replacements:
No components of significance
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
12
www.EMGcorp.com p 800.733.0660
Actions/Comments:
There is no evidence of storm water runoff from adjacent properties. The storm water system appears to provide adequate runoff
capacity. There is no evidence of major ponding or erosion.
5.4. Topography and Landscaping
Item Description
Site Topography Generally flat.
Landscaping
Trees Grass Flower
Beds Planters
Drought
Tolerant
Plants
Decorative
Stone None
☒ ☒ ☐ ☐ ☐ ☐ ☐
Landscaping
Condition Good
Irrigation
Automatic
Underground Drip Hand Watering None
☐ ☐ ☐ ☒
Irrigation Condition --
Retaining Walls
Type Location Condition
None -- --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The topography and adjacent uses do not appear to present conditions detrimental to the property. There are no significant areas of
erosion.
5.5. General Site Improvements
Property Signage
Property Signage Post mounted wood
Street Address Displayed? Yes
Site and Building Lighting
Site Lighting
None Pole Mounted Bollard Lights Ground
Mounted
Parking Lot
Pole Type
☒ ☐ ☐ ☐ ☐
Choose an item.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
13
www.EMGcorp.com p 800.733.0660
Site and Building Lighting
Building Lighting
None Wall Mounted Recessed Soffit
☐ ☒ ☐
Fair
Site Fencing
Type Location Condition
None -- --
REFUSE DISPOSAL
Refuse Disposal Common area dumpsters
Dumpster Locations Mounting Enclosure Contracted? Condition
South part of Front Elevation Asphalt
paving None No Fair
Other Site Amenities
Description Location Condition
Playground Equipment None -- --
Tennis Courts None -- --
Basketball Court None -- --
Swimming Pool None -- --
Anticipated Lifecycle Replacements:
Exterior lighting
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
14
www.EMGcorp.com p 800.733.0660
6. Building Architectural and Structural Systems
6.1. Foundations
Building Foundation
Item Description Condition
Foundation Slab on grade with integral footings Good
Basement and Crawl Space None --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
There are no significant signs of settlement, deflection, or movement.
6.2. Superstructure
Building Superstructure
Item Description Condition
Framing / Load-Bearing Walls Steel columns and beams Good
Ground Floor Concrete slab Good
Upper Floor Framing Wood joists Good
Upper Floor Decking Plywood or OSB Fair
Roof Framing Steel beams or girders Good
Roof Decking Metal decking Fair
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The superstructure is exposed in some locations, which allows for limited observation. Walls and floors appear to be plumb, level,
and stable. There are no significant signs of deflection or movement.
6.3. Roofing
Primary Roof
Type / Geometry Gable Roof Finish Metal
Maintenance Outside Contractor Roof Age 9 Yrs
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
15
www.EMGcorp.com p 800.733.0660
Primary Roof
Flashing Sheet Metal Warranties None
Parapet Copings None Roof Drains Gutters and downspouts
Fascia Metal Panel Insulation Fiberglass batts
Soffits None Skylights No
Attics Steel beams Ponding No
Ventilation Source-1 Ridge Vents Leaks Observed No
Ventilation Source-2 -- Roof Condition Good
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The roof finishes are original. Information regarding roof warranties or bonds was not available. The roofs are maintained by an
outside contractor.
There is no evidence of active roof leaks.
There is no evidence of roof deck or insulation deterioration. The roof substrate and insulation should be inspected during any future
roof repair or replacement work.
Roof drainage appears to be adequate. Clearing and minor repair of drain system components should be performed regularly as part
of the property management’s routine maintenance and operations program.
The attics are not accessible and it could not be determined if there is moisture, water intrusion, or excessive daylight in the attics.
6.4. Exterior Walls
Building Exterior Walls
Type Location Condition
Primary Finish Metal siding Good
Secondary Finish Painted CMU Good
Accented with -- --
Soffits Not Applicable --
Building sealants (caulking) are located between dissimilar materials, at joints, and around window and door openings.
Anticipated Lifecycle Replacements:
No components of significance
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
16
www.EMGcorp.com p 800.733.0660
Actions/Comments:
The metal siding has isolated areas of damaged siding along the top side of Garage No. 5. The damaged siding must be repaired.
The cost for this work is relatively insignificant and the work can be performed as part of the property managements’ routine
maintenance program.
6.5. Exterior and Interior Stairs
Building Exterior and Interior Stairs
Type Description Riser Handrail Balusters Condition
Building Exterior Stairs None -- -- -- --
Building Interior Stairs Wood-framed Closed Wood Wood Good
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended.
6.6. Exterior Windows and Doors
Building Windows
Window Framing Glazing Location Window
Screen Condition
Aluminum framed, operable Double glaze Front Elevation of Building ☐ Good
Building Doors
Main Entrance Doors Door Type Condition
Metal, insulated Fair
Secondary Entrance Doors Metal, insulated Fair
Service Doors Metal, hollow Fair
Overhead Doors Aluminium Good
Anticipated Lifecycle Replacements:
Exterior Metal doors
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
17
www.EMGcorp.com p 800.733.0660
6.7. Patio, Terrace, and Balcony
Not applicable. There are no patios, terraces, or balconies.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
18
www.EMGcorp.com p 800.733.0660
7. Building Mechanical and Plumbing Systems
See the Mechanical Equipment List in the Appendices for the quantity, manufacturer’s name, model number, capacity and year of
manufacturer of the major mechanical equipment, if available.
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC)
Individual Units
Primary Components Split system furnaces and condensing units
Cooling (if separate from above) performed via components above
Quantity and Capacity Ranges 1 unit ranging from 5 tons/BTUH
Total Heating or Cooling Capacity 5 tons/BTUH
Heating Fuel Electric
Location of Equipment Interior Garage
Space Served by System Entire building
Age Ranges All units dated 2014
Primary Component Condition Good
Supplemental Components
Supplemental Component #1 Suspended unit heaters
Location / Space Served by Suspended Unit Heaters Above Office in Garage
Suspended Unit Heater Condition Good
Supplemental Component #2 Ceiling Fans
Location / Space Served by Ceiling Fans Throughout Building
Ceiling Fans Condition Fair
Supplemental Component #3 Engine Exhaust Removal
Location / Space Served by Engine Exhaust Removal Ceiling of Garage
Engine Exhaust Removal Condition Good
Controls and Ventilation
HVAC Control System Individual programmable thermostats/controls
HVAC Control System Condition Good
Building Ventilation Engine Exhaust Removal
Ventilation System Condition Good
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
19
www.EMGcorp.com p 800.733.0660
Anticipated Lifecycle Replacements:
Engine Exhaust Removal Fans
Suspended Unit Heaters
Electric Furnace
Ceiling Fans
Condensing Unit
Actions/Comments:
The HVAC systems are maintained by an outside contractor. Records of the installation, maintenance, upgrades, and replacement
of the HVAC equipment at the property have been maintained since the property was first occupied.
The HVAC equipment appears to vary in age. The property is relatively new and has not required any major HVAC equipment
replacements.
The HVAC equipment appears to be functioning adequately overall. No chronic problems were reported and an overall sense of
satisfaction with the systems was conveyed. However, due to the inevitable failure of parts and components over time, some of the
equipment will require replacement.
7.2. Building Plumbing and Domestic Hot Water
Building Plumbing System
Type Description Condition
Water Supply Piping Copper Fair
Waste/Sewer Piping Cast iron Fair
Vent Piping Cast iron Fair
Water Meter Location Right Elevation of Building
Domestic Water Heaters or Boilers
Components Water Heaters
Fuel Electric
Quantity and Input Capacity 1 unit
Storage Capacity 50 gallons
Boiler or Water Heater Condition Fair
Supplementary Storage Tanks? No
Storage Tank Quantity & Volume --
Quantity of Storage Tanks --
Storage Tank Condition --
Domestic Hot Water Circulation Pumps (3 HP and over) No
Adequacy of Hot Water Adequate
Adequacy of Water Pressure Adequate
Plumbing Fixtures
Water Closets Residential grade
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
20
www.EMGcorp.com p 800.733.0660
Plumbing Fixtures
Toilet (Water Closet) Flush Rating 1.6 GPF
Common Area Faucet Nominal Flow Rate 2.0 GPM
Condition Fair
Anticipated Lifecycle Replacements:
Water Heater
Backflow Preventer
Water Closets
Sinks
Lavatory
Bathroom Vanity
Actions/Comments:
The plumbing systems appear to be well maintained and functioning adequately. The water pressure appears to be sufficient. No
significant repair actions or short-term replacement costs are required. Routine and periodic maintenance is recommended. Future
lifecycle replacements of the components or systems listed above will be required.
7.3. Building Gas Distribution
Not applicable. The property is not supplied with natural gas.
7.4. Building Electrical
Building Electrical Systems
Electrical Lines Underground Transformer Pad-mounted
Main Service Size 800 Amps Volts 120/240 Volt, single-phase
Meter & Panel Location
North Elevation of
Building Branch Wiring Copper
Conduit Metallic Step-Down
Transformers? No
Security / Surveillance
System? No Building Intercom
System? No
Lighting Fixtures T-12
Main Distribution Condition Good
Secondary Panel and
Transformer Condition Good
Lighting Condition Fair
Anticipated Lifecycle Replacements:
Distribution Panels
Interior Lighting System
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
21
www.EMGcorp.com p 800.733.0660
Actions/Comments:
The onsite electrical systems up to the meters are owned and maintained by the respective utility company.
The electrical service and capacity appear to be adequate for the property’s demands.
The panels are mostly original 2008 components. The electrical service is reportedly adequate for the facility’s needs. However, due
to the age of the panels and increasing difficulty of obtaining replacement parts over time, lifecycle replacements are recommended
per above.
7.5. Building Elevators and Conveying Systems
Not applicable. There are no elevators or conveying systems.
7.6. Fire Protection and Security Systems
Item Description
Type None
Fire Alarm System
Central Alarm Panel ☐ Battery-Operated Smoke
Detectors ☒ Alarm Horns ☐
Annunciator Panels ☐ Hard-Wired Smoke
Detectors ☐ Strobe Light Alarms ☐
Pull Stations ☐ Emergency Battery-Pack
Lighting ☒ Illuminated EXIT Signs ☒
Alarm System
Condition --
Sprinkler System
None ☐ Standpipes ☐ Backflow Preventer ☒
Hose Cabinets ☐ Fire Pumps ☐ Siamese Connections ☐
Suppression
Condition --
Central Alarm Panel
System
Location of Alarm Panel Installation Date of Alarm Panel
-- --
Fire Extinguishers
Last Service Date Servicing Current?
2016 No
Hydrant Location None
Siamese Location --
Special Systems Kitchen Suppression System ☐ Computer Room Suppression System ☐
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
22
www.EMGcorp.com p 800.733.0660
The vast majority of the building is not protected by fire suppression. Due to its construction date, the facility is most likely
“grandfathered” by code and the installation of fire sprinklers not required until major renovations are performed. Regardless of when
or if installation of facility-wide fire suppression is required by the governing municipality, EMG recommends a retrofit be performed.
As part of the major recommended short-term renovations, a facility-wide fire suppression retrofit is recommended. A budgetary cost
is included.
The fire alarm systems appear somewhat antiquated and not up to current standards. Due to the age of the components and
apparent shortcomings, a full modernization project is recommended. As part of the major recommended short-term renovations, a
facility-wide fire alarm modernization is recommended. A budgetary cost is included.
7.7. Life Support Systems
Not Applicable
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
23
www.EMGcorp.com p 800.733.0660
8. I nterior Spaces
8.1. I nterior Finishes
The facility is used as an Office Building and Garage for the City of Yorkville.
The most significant interior spaces include offices, and garage. Supporting areas include hallways, stairs, administrative offices,
restrooms, employee break rooms and garages.
The following table generally describes the locations and typical conditions of the interior finishes within the facility:
Typical Floor Finishes
Floor Finish Locations General Condition
Concrete Offices, Garage, Restrooms Good
Typical Wall Finishes
Wall Finish Locations General Condition
Painted drywall Office and Restroom Fair
Steel Garage Good
Typical Ceiling Finishes
Ceiling Finish Locations General Condition
Painted drywall Office and Restroom Fair
Metal Garage Good
Interior Doors
Item Type Condition
Interior Doors Hollow core Wood Fair
Door Framing Wood Fair
Fire Doors No --
Anticipated Lifecycle Replacements:
Wood Hollow-Core
Wood Hollow-Core Door w/Glass
Interior paint
Actions/Comments:
It appears that the interior finishes are original.
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
24
www.EMGcorp.com p 800.733.0660
8.2. Commercial Kitchen & Laundry Equipment
Not applicable. There are no commercial kitchens or laundry onsite.
The Office kitchen includes the following residential appliances, fixtures, and equipment:
Commercial Kitchen
Appliance Comment Condition
Refrigerators Up-right Fair
Freezers -- --
Ranges -- --
Ovens -- --
Griddles / Grills -- --
Fryers -- --
Hood -- --
Dishwasher -- --
Microwave ☒ Fair
Ice Machines ☐ --
Steam Tables ☐ --
Work Tables ☐ --
Shelving ☐ --
Commercial Laundry
Equipment Comment Condition
Commercial Washing Machines ☐ --
Commercial Dryers ☐ --
Residential Washers ☒ Fair
Residential Dryers ☒ Fair
Anticipated Lifecycle Replacements:
Refrigerator
Kitchen Cabinet
Residential Washer/Dryer
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
25
www.EMGcorp.com p 800.733.0660
9. Other Structures
Not applicable. There are no major accessory structures.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
26
www.EMGcorp.com p 800.733.0660
10. Certification
City of Yorkville retained EMG to perform this Facility Condition Assessment in connection with its continued operation of Public Works
Garage (Frame Building), 185 Wolf Street, Yorkville, IL 60560, the “Property”. It is our understanding that the primary interest of
ClientN is to locate and evaluate materials and building system defects that might significantly affect the value of the property and to
determine if the present Property has conditions that will have a significant impact on its continued operations.
The conclusions and recommendations presented in this report are based on the brief review of the plans and records made available
to our Project Manager during the site visit, interviews of available property management personnel and maintenance contractors
familiar with the Property, appropriate inquiry of municipal authorities, our Project Manager’s walk-through observations during the site
visit, and our experience with similar properties.
No testing, exploratory probing, dismantling or operating of equipment or in-depth studies were performed unless specifically required
under Section 2 of this report. This assessment did not include engineering calculations to determine the adequacy of the Property’s
original design or existing systems. Although walk-through observations were performed, not all areas were observed (See Section 4.2
for areas observed). There may be defects in the Property, which were in areas not observed or readily accessible, may not have been
visible, or were not disclosed by management personnel when questioned. The report describes property conditions at the time that
the observations and research were conducted.
This report has been prepared on behalf of and exclusively for the use of City of Yorkville for the purpose stated within Section 2 of this
report. The report, or any excerpt thereof, shall not be used by any party other than City of Yorkville or for any other purpose than that
specifically stated in our agreement or within Section 2 of this report without the express written consent of EMG.
Any reuse or distribution of this report without such consent shall be at City of Yorkville and the recipient’s sole risk, without liability to
EMG.
Prepared by: Tammy Prusa
Project Manager
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
27
www.EMGcorp.com p 800.733.0660
11. Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: EMG Accessibility Checklist
Appendix D: Pre-Survey Questionnaire
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: LEFT ELEVATION
#3: REAR ELEVATION
#4: RIGHT ELEVATION
#5: SIDEWALK, CONCRETE
#6: ASPHALT PAVEMENT
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
#7: FOUNDATIONS, CONCRETE
SLAB-ON-GRADE
#8: ROOF, METAL
#9: EXTERIOR WALL, ALUMINUM
SIDING
#10: INTERIOR STAIR/RAMP RAILS,
WOOD
#11: WINDOW, ALUMINUM DOUBLE-
GLAZED
#12: OVERHEAD DOOR, ALUMINUM
ROLL-UP
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
#13: EXTERIOR DOOR, STEEL W/
GLASS
#14: EXTERIOR DOOR, STEEL
#15: DAMAGE TO OVERHEAD DOOR
NO. 5.
#16: RESIDENTIAL FIXTURES,
CEILING FAN
#17: EXHAUST FAN, CENTRIFUGAL
#18: UNIT HEATER, NATURAL GAS
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
#19: FURNACE, ELECTRIC
#20: CONDENSING UNIT/HEAT PUMP,
SPLIT SYSTEM
#21: UNIT HEATER, NATURAL GAS
#22: WATER HEATER, ELECTRIC,
RESIDENTIAL
#23: BACKFLOW PREVENTER
#24: LAVATORY, VITREOUS CHINA
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
#25: TOILET, FLUSH TANK
#26: SINK, PLASTIC
#27: RESIDENTIAL APPLIANCES,
CLOTHES WASHER
#28: SINK, STAINLESS STEEL
#29:
BATHROOM VANITY CABINET,
WOOD, WITH CULTURED
MARBLE SINK TOP
#30: INCANDESCENT LIGHTING
FIXTURE, BASIC
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
#31: DISTRIBUTION PANEL #1
#32: DISTRIBUTION PANEL #2
#33: DISTRIBUTION PANEL #3
#34: LIGHTING SYSTEM, INTERIOR,
OFFICE BUILDING
#35: DISTRIBUTION PANEL #4
#36: DISTRIBUTION PANEL #5
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
#37: HIGH PRESSURE SODIUM
LIGHTING FIXTURE
#38: EXIT LIGHTING FIXTURE, LED
#39: FIRE EXTINGUISHER
#40:
INTERIOR WALL FINISH,
GYPSUM
BOARD/PLASTER/METAL
#41: INTERIOR WINDOW
#42: INTERIOR WALL FINISH, STEEL
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
#43: INTERIOR DOOR, WOOD SOLID-
CORE W/ GLASS
#44: INTERIOR DOOR, WOOD
HOLLOW-CORE
#45: INTERIOR CEILING FINISH,
METAL
#46: INTERIOR CEILING FINISH,
GYPSUM BOARD/PLASTER
#47: KITCHEN CABINET, BASE AND
WALL SECTION, WOOD
#48: RESIDENTIAL APPLIANCES,
REFRIGERATOR
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
#49: RESIDENTIAL APPLIANCES,
CLOTHES DRYER
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Public Works Garage (Frame Building)
Project Number:
122700.17R000-041.322
Source:
Google Earth
On-Site Date:
June 26, 2017
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
Appendix C:
EMG Accessibility Checklist
Page 1 of 4
Date Completed: June 26, 2017
Property Name: Public Works Garage (Frame Building)
EMG Project Number: 122700.17R000-041.322
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
Appendix D:
Pre-Survey Questionnaire
PP RR EE --SS UU RR VV EE YY QQ UU EE SS TT II OO NN NN AA II RR EE
This questionnaire must be completed by the property owner, the owner's designated representative, or someone knowledgeable about
the subject property. The completed form must be presented to EMG's Field Observer on the day of the site visit. If the form is
not completed, EMG’s Project Manager will require additional time during the on-site visit with such a knowledgeable person in order to
complete the questionnaire. During the site visit, EMG's Field Observer may ask for details associated with selected questions. This
questionnaire will be utilized as an exhibit in EMG's final Physical Needs Assessment.
Name of person completing questionnaire:
Association with property:
Length of association with property:
Date Completed:
Phone Number:
Property Name:
Property Address
Year Built
# of Buildings/Stories
# of Units
Acres
Directions: Please answer all questions to the best of your knowledge and in good faith. Please provide additional details in the
Comments column, or backup documentation for any Yes responses.
INSPECTIONS DATE OF LAST
REPAIR/REPLACEMENT
LIST ANY OUTSTANDING REPAIRS REQUIRED
1
Elevators
How many?
Type of elevator traction or hydraulic
How old is the current elevator(s)?
2
HVAC
Describe the existing HVAC system (what type of system).
How old is the current system?
3
Mechanical
Systems
Describe current mechanical systems
Give ages of each component and type
4
Electrical
system
How old is the current electrical system?
5
Plumbing
System
Describe the existing plumbing system (what type of piping for
domestic water distribution system, sewer main, storm water).
How old are the current plumbing system components?
6
Life-Safety/Fire
Systems
What systems are currently in place?
How old are they?
INSPECTIONS DATE OF LAST
REPAIR/REPLACEMENT
LIST ANY OUTSTANDING REPAIRS REQUIRED
7
Roofs
What type of roof is on the building(s), What type of decking?
How old is it/are they?
8
Foundation,
Structure
What type of foundation? (slab on grade, piers, concrete foundation
walls, footings)
What type of structure (wood frame, concrete, steel)
QUESTION RESPONSE
9
List any major capital improvement within the
last three years.
10
List any major capital expenditures planned for
the next year.
11
Are any building systems (HVAC, roof,
interior/exterior finishes, paving, etc.) the
responsibilities of the tenant to maintain and
replace?
Mark the column corresponding to the appropriate response. Please provide additional details in the
Comments column, or backup documentation for any Yes responses. Note: NA indicates “Not Applicable”,
Unk indicates “Unknown”
QUESTION RESPONSE COMMENTS
Y N NA Unk
12 Are there any unresolved building,
fire, or zoning code issues?
13 Are there any "down" or unusable
units?
14 Are there any problems with
erosion, stormwater drainage or
areas of paving that do not drain?
15 Is the property served by a private
water well? If so, please give age of current well.
16 Is the property served by a private
septic system or other waste
treatment systems?
If so, please give age.
Mark the column corresponding to the appropriate response. Please provide additional details in the
Comments column, or backup documentation for any Yes responses. Note: NA indicates “Not Applicable”,
Unk indicates “Unknown”
QUESTION RESPONSE COMMENTS
Y N NA Unk
17 Are there any problems with
foundations or structures?
18 Is there any water infiltration in
basements or crawl spaces?
19 Are there any wall, or window
leaks?
20 Are there any roof leaks?
21 Is the roofing covered by a
warranty or bond?
22 Are there any poorly insulated
areas?
23 Is Fire Retardant Treated (FRT)
plywood used?
24 Is exterior insulation and finish
system (EIFS) or a synthetic
stucco finish used?
25 Are there any problems with the
utilities, such as inadequate
capacities?
26 Are there any problems with the
landscape irrigation systems?
27 Has a termite/wood boring insect
inspection been performed within
the last year?
28 Do any of the HVAC systems use
R-11, 12, or 22 refrigerants?
29 Has any part of the property ever
contained visible suspect mold
growth?
30 Is there a mold Operations and
Maintenance Plan?
31 Have there been indoor air quality
or mold related complaints from
tenants?
32 Is polybutylene piping used?
33 Are there any plumbing leaks or
water pressure problems?
34 Are there any leaks or pressure
problems with natural gas service?
Mark the column corresponding to the appropriate response. Please provide additional details in the
Comments column, or backup documentation for any Yes responses. Note: NA indicates “Not Applicable”,
Unk indicates “Unknown”
QUESTION RESPONSE COMMENTS
Y N NA Unk
35 Does any part of the electrical
system use aluminum wiring?
36 Do Residential units have a less
than 60-Amp service?
37 Do Commercial units have less
than 200-Amp service?
38 Are there any recalled fire sprinkler
heads (Star, GEM, Central,
Omega)?
39 Is there any pending litigation
concerning the property?
40 If built before 1978, has there been
previous asbestos testing
completed
41 Does the property have an
Asbestos Operations &
Maintenance Program in place?
42 If built before 1978, has there been
previous comprehensive Lead-
Based Paint testing completed?
43 If built before 1960, has there been
a previous Lead Based Paint Risk
Assessment completed?
44 Does the property have a Lead-
Based Paint Operations &
Maintenance Program in place?
45 Has the management previously
completed an ADA review?
46 Have any ADA improvements
been made to the property?
47 Does a Barrier Removal Plan exist
for the property?
48 Has the Barrier Removal Plan
been approved by an arms-length
third party?
49 Has building ownership or
management received any ADA
related complaints?
50 Does elevator equipment require
upgrades to meet ADA standards?
51 Are there any problems with
exterior lighting?
Mark the column corresponding to the appropriate response. Please provide additional details in the
Comments column, or backup documentation for any Yes responses. Note: NA indicates “Not Applicable”,
Unk indicates “Unknown”
QUESTION RESPONSE COMMENTS
Y N NA Unk
52 Are there any other significant
issues/hazards with the property?
53 Are there any unresolved
construction defects at the
property?
Please provide EMG with any previous reports completed for the property, including equipment testing, structural
assessments, mechanical assessments, plumbing assessments, sewer line scoping, roof scans, electrical testing, etc.
PUBLIC WORKS GARAGE (FRAME BUILDING) EMG PROJECT NO.: 122700.17R000-041.322
www.EMGcorp.com p 800.733.0660
On the day of the site visit, provide EMG's Field Observer access to all of the available documents listed below.
Provide copies if possible.
INFORMATION REQUIRED
1. All available construction documents (blueprints) for
the original construction of the building or for any tenant
improvement work or other recent construction work.
2. A site plan, preferably 8 1/2" X 11", which depicts the
arrangement of buildings, roads, parking stalls, and other
site features.
3. For commercial properties, provide a tenant list which
identifies the names of each tenant, vacant tenant units,
the floor area of each tenant space, and the gross and
net leasable area of the building(s).
4. For apartment properties, provide a summary of the
apartment unit types and apartment unit type quantities,
including the floor area of each apartment unit as
measured in square feet.
5. For hotel or nursing home properties, provide a
summary of the room types and room type quantities.
6. Copies of Certificates of Occupancy, building permits,
fire or health department inspection reports, elevator
inspection certificates, roof or HVAC warranties, or any
other similar, relevant documents.
7. The names of the local utility companies which serve
the property, including the water, sewer, electric, gas,
and phone companies.
8. The company name, phone number, and contact
person of all outside vendors who serve the property,
such as mechanical contractors, roof contractors, fire
sprinkler or fire extinguisher testing contractors, and
elevator contractors.
9. A summary of recent (over the last 5 years) capital
improvement work which describes the scope of the
work and the estimated cost of the improvements.
Executed contracts or proposals for improvements.
Historical costs for repairs, improvements, and
replacements.
10. Records of system & material ages (roof, MEP,
paving, finishes, furnishings).
11. Any brochures or marketing information.
12. Appraisal, either current or previously prepared.
13. Current occupancy percentage and typical turnover
rate records (for commercial and apartment properties).
14. Previous reports pertaining to the physical condition
of property.
15. ADA survey and status of improvements
implemented.
16. Current / pending litigation related to property
condition.
Your timely compliance with this request is greatly appreciated.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Park & Rec Office
201 West Hydraulic Avenue
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-011.322 June 30, 2017 May 23, 2017
FACILITY CONDITION ASSESSMENT
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
TABLE OF CONTENTS
1. Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
1.3. Special Issues and Follow-Up Recommendations ...................................................................... 3
1.4. Opinions of Probable Cost .......................................................................................................... 3
1.4.1. Methodology ................................................................................................................................ 4
1.4.2. Immediate Repairs ...................................................................................................................... 4
1.4.3. Replacement Reserves ............................................................................................................... 4
2. Purpose and Scope .............................................................................................................................. 5
2.1. Purpose ....................................................................................................................................... 5
2.2. Scope .......................................................................................................................................... 6
2.3. Personnel Interviewed ................................................................................................................. 6
2.4. Documentation Reviewed ........................................................................................................... 7
2.5. Pre-Survey Questionnaire ........................................................................................................... 7
2.6. Weather Conditions ..................................................................................................................... 7
3. Accessibility and Property Research ................................................................................................. 8
3.1. ADA Accessibility ........................................................................................................................ 8
3.2. Municipal Information, Flood Zone and Seismic Zone ................................................................ 8
4. Existing Building Assessment ............................................................................................................ 9
4.1. Unit or Space Types .................................................................................................................... 9
4.2. Inaccessible Areas or Key Spaces Not Observed ...................................................................... 9
5. Site Improvements ............................................................................................................................. 10
5.1. Utilities ....................................................................................................................................... 10
5.2. Parking, Paving, and Sidewalks ................................................................................................ 10
5.3. Drainage Systems and Erosion Control .................................................................................... 11
5.4. Topography and Landscaping ................................................................................................... 12
5.5. General Site Improvements ....................................................................................................... 12
6. Building Architectural and Structural Systems ............................................................................... 14
6.1. Foundations ............................................................................................................................... 14
6.2. Superstructure ........................................................................................................................... 14
6.3. Roofing ...................................................................................................................................... 14
6.4. Exterior Walls ............................................................................................................................ 15
6.5. Exterior and Interior Stairs ......................................................................................................... 16
6.6. Exterior Windows and Doors ..................................................................................................... 16
6.7. Patio, Terrace, and Balcony ...................................................................................................... 16
7. Building Mechanical and Plumbing Systems .................................................................................. 17
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC) ..................................................... 17
7.2. Building Plumbing and Domestic Hot Water ............................................................................. 18
7.3. Building Gas Distribution ........................................................................................................... 19
7.4. Building Electrical ...................................................................................................................... 19
7.5. Building Elevators and Conveying Systems .............................................................................. 19
7.6. Fire Protection and Security Systems ....................................................................................... 20
7.7. Life Support Systems ................................................................................................................ 20
8. Interior Spaces .................................................................................................................................... 21
8.1. Interior Finishes ......................................................................................................................... 21
8.2. Commercial Kitchen & Laundry Equipment .............................................................................. 22
9. Other Structures ................................................................................................................................. 23
10. Certification ......................................................................................................................................... 24
11. Appendices ......................................................................................................................................... 25
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
1
1. Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 201 West Hydraulic Avenue, Yorkville, Kendall, IL 60560
Year Constructed/Renovated: 1985
Current Occupants: City of Yorkville – Parks and Recreation
Percent Utilization: 100%
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Office/Day Care
Site Area: 0.37 acres
Building Area: 4,700 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of
Spaces: 17 spaces in open lots
Building Construction: Masonry bearing walls and steel-framed roofs
Roof Construction: Flat roofs with built-up membrane.
Exterior Finishes: Brick Veneer
Heating, Ventilation & Air
Conditioning: Individual package split-system units
Fire and Life/Safety: Hydrants, smoke detectors, carbon monoxide detectors, extinguishers,
exit signs, and emergency lights.
Dates of Visit: May 23, 2017
On-Site Point of Contact (POC): Scott Sleezer
Assessment and Report
Prepared by: Paul Prusa
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
2
Systemic Condition Summary
Site Fair HVAC Fair
Structure Good Plumbing Fair
Roof Fair Electrical Fair
Vertical Envelope Fair Elevators --
Interiors Good Fire Fair
The following bullet points highlight the most significant short term and modernization recommendations:
Installation of a complete fire suppression system
Installation of a complete fire alarm system
Asphalt pavement mill & overlay
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained in recent years and is in good overall condition.
According to property management personnel, the property has had an active capital improvement expenditure program over the past
three years, primarily consisting of new flooring, asphalt pavement seal coating, and interior painting. Supporting documentation was
not provided in support of these claims but some of the work is evident.
1.2. F acility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
3
Fci Condition
Rating Definition Percentage
Value
Good In new or well-maintained condition, with no visual evidence
of wear, soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and
functioning condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its
useful or serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal
is now necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 14.1% Poor
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 61.6% Very Poor
Current Replacement Value (CRV) 4,700 SF * 183.24 / SF = $366,474
Year 0 (Current Year) - Immediate Repairs (IR) $51,805
Years 1-10 – Replacement Reserves (RR) $228,750
Total Capital Needs $277,555
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Installation of a complete fire suppression system
Installation of a complete fire alarm system
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
1.3. Special Issues and Follow-Up Recommendations
As part of the FCA, a limited assessment of accessible areas of the building(s) was performed to determine the presence of fungal
growth, conditions conducive to fungal growth, and/or evidence of moisture. Property personnel were interviewed concerning any
known or suspected fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Sampling is not a part of this
assessment.
There are no visual indications of the presence of fungal growth, conditions conducive to fungal growth, or evidence of moisture in
representative readily accessible areas of the property.
1.4. Opinions of Probable Cost
Cost estimates are attached at the front of this report (following the cover page).
These estimates are based on Invoice or Bid Document/s provided either by the Owner/facility and construction costs developed by
construction resources such as R.S. Means and Marshall & Swift, EMG’s experience with past costs for similar properties, city cost
indexes, and assumptions regarding future economic conditions.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
4
Opinions of probable costs should only be construed as preliminary, order of magnitude budgets. Actual costs most probably will vary
from the consultant’s opinions of probable costs depending on such matters as type and design of suggested remedy, quality of
materials and installation, manufacturer and type of equipment or system selected, field conditions, whether a physical deficiency is
repaired or replaced in whole, phasing of the work (if applicable), quality of contractor, quality of project management exercised, market
conditions, and whether competitive pricing is solicited, etc. ASTM E2018-08 recognizes that certain opinions of probable costs cannot
be developed within the scope of this guide without further study. Opinions of probable cost for further study should be included in the
FCA.
1.4.1. Methodology
Based upon site observations, research, and judgment, along with referencing Expected Useful Life (EUL) tables from various industry
sources, EMG opines as to when a system or component will most probably necessitate replacement. Accurate historical replacement
records, if provided, are typically the best source of information. Exposure to the elements, initial quality and installation, extent of use,
the quality and amount of preventive maintenance exercised, etc., are all factors that impact the effective age of a system or
component. As a result, a system or component may have an effective age that is greater or less than its actual chronological age.
The Remaining Useful Life (RUL) of a component or system equals the EUL less its effective age. Projections of Remaining Useful Life
(RUL) are based on continued use of the Property similar to the reported past use. Significant changes in occupants and/or usage may
affect the service life of some systems or components.
Where quantities could not be derived from an actual take-off, lump sum costs or allowances are used. Estimated costs are based on
professional judgment and the probable or actual extent of the observed defect, inclusive of the cost to design, procure, construct and
manage the corrections.
1.4.2. Immediate Repairs
Immediate repairs are opinions of probable costs that require immediate action as a result of: (1) material existing or potential unsafe
conditions, (2) material building or fire code violations, or (3) conditions that, if not addressed, have the potential to result in, or
contribute to, critical element or system failure within one year or will most probably result in a significant escalation of its remedial cost.
1.4.3. Replacement Reserves
Replacement Reserves are for recurring probable expenditures, which are not classified as operation or maintenance expenses. The
replacement reserves should be budgeted for in advance on an annual basis. Replacement Reserves are reasonably predictable both
in terms of frequency and cost. However, Replacement Reserves may also include components or systems that have an
indeterminable life but, nonetheless, have a potential for failure within an estimated time period.
Replacement Reserves exclude systems or components that are estimated to expire after the reserve term and are not considered
material to the structural and mechanical integrity of the subject property. Furthermore, systems and components that are not deemed
to have a material effect on the use of the Property are also excluded. Costs that are caused by acts of God, accidents, or other
occurrences that are typically covered by insurance, rather than reserved for, are also excluded.
Replacement costs are solicited from ownership/property management, EMG’s discussions with service companies, manufacturers'
representatives, and previous experience in preparing such schedules for other similar facilities. Costs for work performed by the
ownership’s or property management’s maintenance staff are also considered.
EMG’s reserve methodology involves identification and quantification of those systems or components requiring capital reserve funds
within the assessment period. The assessment period is defined as the effective age plus the reserve term. Additional information
concerning system’s or component’s respective replacement costs (in today's dollars), typical expected useful lives, and remaining
useful lives were estimated so that a funding schedule could be prepared. The Replacement Reserves Schedule presupposes that all
required remedial work has been performed or that monies for remediation have been budgeted for items defined in the Immediate
Repair Cost Estimate.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
5
2. Purpose and Scope
2.1. Purpose
EMG was retained by the client to render an opinion as to the Property’s current general physical condition on the day of the site visit.
Based on the observations, interviews and document review outlined below, this report identifies significant deferred maintenance
issues, existing deficiencies, and material code violations of record at municipal offices, which affect the Property’s use. Opinions are
rendered as to its structural integrity, building system condition and the Property’s overall condition. The report also notes building
systems or components that have realized or exceeded their typical expected useful lives.
CONDITIONS:
The physical condition of building systems and related components are typically defined as being in one of five conditions: Excellent,
Good, Fair, Poor, Failed or a combination thereof. For the purposes of this report, the following definitions are used:
Excellent = New or very close to new; component or system typically has been installed within the past year, sound and
performing its function. Eventual repair or replacement will be required when the component or system either
reaches the end of its useful life or fails in service.
Good = Satisfactory as-is. Component or system is sound and performing its function, typically within the first third
of its lifecycle. However, it may show minor signs of normal wear and tear. Repair or replacement will be
required when the component or system either reaches the end of its useful life or fails in service.
Fair = Showing signs of wear and use but still satisfactory as-is, typically near the median of its estimated useful
life. Component or system is performing adequately at this time but may exhibit some signs of wear,
deferred maintenance, or evidence of previous repairs. Repair or replacement will be required due to the
component or system’s condition and/or its estimated remaining useful life.
Poor = Component or system is significantly aged, flawed, functioning intermittently or unreliably; displays obvious
signs of deferred maintenance; shows evidence of previous repair or workmanship not in compliance with
commonly accepted standards; has become obsolete; or exhibits an inherent deficiency. The present
condition could contribute to or cause the deterioration of contiguous elements or systems. Either full
component replacement is needed or repairs are required to restore to good condition, prevent premature
failure, and/or prolong useful life.
Failed
= Component or system has ceased functioning or performing as intended. Replacement, repair, or other
significant corrective action is recommended or required.
Not Applicable
= Assigning a condition does not apply or make logical sense, most commonly due to the item in question not
being present.
FORMAT OF THE BODY OF THE REPORT:
Throughout sections 5 through 9 of this report, each report section will typically contain three subsections organized in the following
sequence:
A descriptive table (and/or narrative), which identifies the components assessed, their condition, and other key data points.
A simple bulleted list of Anticipated Lifecycle Replacements, which lists components and assets typically in Excellent, Good, or Fair
condition at the time of the assessment but that will require replacement or some other attention once aged past their estimated
useful life. These listed components are typically included in the associated inventory database with costs identified and budgeted
beyond the first several years.
A bulleted cluster of Actions/Comments, which include more detailed narratives describing deficiencies, recommended repairs, and
short term replacements. The assets and components associated with these bullets are/were typically problematic and in Poor or
Failed condition at the time of the assessment, with corresponding costs included within the first few years.
PLAN TYPES:
Each line item in the cost database is assigned a Plan Type, which is the primary reason or rationale for the recommended
replacement, repair, or other corrective action. This is the “why” part of the equation. A cost or line item may commonly have more
than one applicable Plan Type; however, only one Plan Type will be assigned based on the “best” fit, typically the one with the greatest
significance. The following Plan Types are listed in general weighted order of importance:
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
6
Safety = An observed or reported unsafe condition that if left unaddressed could result in an injury; a system or
component that presents a potential liability risk.
Performance/Integrity = Component or system has failed, is almost failing, performs unreliably, does not perform as intended,
and/or poses a risk to overall system stability.
Accessibility = Does not meet ADA, UFAS, and/or other handicap accessibility requirements.
Environmental = Improvements to air or water quality, including removal of hazardous materials from the building or
site.
Modernization/Adaptation
= Conditions, systems, or spaces that need to be upgraded in appearance or function to meet current
standards, facility usage, or client/occupant needs.
Lifecycle/Renewal
= Any component or system in which future repair or replacement is anticipated beyond the next several
years and/or is of minimal substantial early-term consequence.
2.2. Scope
The standard scope of the Facility Condition Assessment includes the following:
Visit the Property to evaluate the general condition of the building and site improvements, review available construction documents in
order to familiarize ourselves with, and be able to comment on, the in-place construction systems, life safety, mechanical, electrical,
and plumbing systems, and the general built environment.
Identify those components that are exhibiting deferred maintenance issues and provide cost estimates for Immediate Costs and
Replacement Reserves based on observed conditions, maintenance history and industry standard useful life estimates. This will
include the review of documented capital improvements completed within the last five-year period and work currently contracted for, if
applicable.
Provide a full description of the Property with descriptions of in-place systems and commentary on observed conditions.
Provide a general statement of the subject Property’s compliance to Title III of the Americans with Disabilities Act. This will not
constitute a full ADA survey, but will help identify exposure to issues and the need for further review.
Perform a limited assessment of accessible areas of the building(s) for the presence of fungal growth, conditions conducive to fungal
growth, and/or evidence of moisture. EMG will also interview Project personnel regarding the presence of any known or suspected
fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Potentially affected areas will be photographed.
Sampling will not be considered in routine assessments.
List the current utility service providers.
Review maintenance records and procedures with the in-place maintenance personnel.
Observe a representative sample of the interior spaces/units, including vacant spaces/units, in order to gain a clear understanding of
the property’s overall condition. Other areas to be observed include the exterior of the property, the roofs, interior common areas,
and the significant mechanical, electrical and elevator equipment rooms.
Provide an Executive Summary at the beginning of this report.
Prepare a mechanical equipment inventory list.
2.3. Personnel Interviewed
The building engineer was interviewed for specific information relating to the physical property, available maintenance procedures,
historical performance of key building systems and components, available drawings and other documentation. The following personnel
from the facility and government agencies were interviewed in the process of conducting the FCA:
Name and Title Organization Phone Number
Scott Sleezer Parks and Recreation 630.878.7291
The FCA was performed without the assistance of an onsite Point of Contact (POC).
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
7
2.4. Documentation Reviewed
Prior to the FCA, relevant documentation was requested that could aid in the knowledge of the subject property’s physical
improvements, extent and type of use, and/or assist in identifying material discrepancies between reported information and observed
conditions. The review of submitted documents does not include comment on the accuracy of such documents or their preparation,
methodology, or protocol. The Documentation Request Form is provided in Appendix E.
Although Appendix E provides a summary of the documents requested or obtained, the following list provides more specific details
about some of the documents that were reviewed or obtained during the site visit.
No documents provided.
2.5. Pre-Survey Questionnaire
A Pre-Survey Questionnaire was sent to the POC prior to the site visit. The questionnaire is included in Appendix E.
2.6. Weather Conditions
May 23, 2017: Raining, with temperatures in the 70s (°F) and winds.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
8
3. Accessibility and Property Research
3.1. ADA Accessibility
Generally, Title III of the Americans with Disabilities Act (ADA) prohibits discrimination by entities to access and use of “areas of public
accommodations” and “commercial facilities” on the basis of disability. Regardless of its age, these areas and facilities must be
maintained and operated to comply with the Americans with Disabilities Act Accessibility Guidelines (ADAAG).
Buildings completed and occupied after January 26, 1992 are required to comply fully with the ADAAG. Existing facilities constructed
prior to this date are held to the lesser standard of compliance to the extent allowed by structural feasibility and the financial resources
available. As an alternative, a reasonable accommodation pertaining to the deficiency must be made.
During the FCA, a limited visual observation for ADA accessibility compliance was conducted. The scope of the visual observation was
limited to those areas set forth in EMG’s Abbreviated Accessibility Checklist provided in Appendix D of this report. It is understood by
the Client that the limited observations described herein does not comprise a full ADA Compliance Survey, and that such a survey is
beyond the scope of EMG’s undertaking. Only a representative sample of areas was observed and, other than as shown on the
Abbreviated Accessibility Checklist, actual measurements were not taken to verify compliance.
At a office property, the areas considered as a public accommodation besides the site itself and parking, are the exterior accessible
route, the interior accessible route up to the tenant lease lines and the interior common areas, including the common area restrooms.
The facility does not appear to be accessible with Title III of the Americans with Disabilities Act. Elements as defined by the ADAAG
that are not accessible as stated within the priorities of Title III, are as follows:
Parking
Adequate number of designated parking stalls and signage for cars are not provided.
Adequate number of designated parking stalls and signage for vans are not provided.
Paths of Travel
Add visual alarm to existing audible fire alarm.
A full ADA Compliance Survey may reveal additional aspects of the property that are not in compliance.
Corrections of these conditions should be addressed from a liability standpoint, but are not necessarily code violations. The Americans
with Disabilities Act Accessibility Guidelines concern civil rights issues as they pertain to the disabled and are not a construction code,
although many local jurisdictions have adopted the Guidelines as such. The cost to address the achievable items noted above is
included in the cost tables.
3.2. Municipal Information, Flood Zone and Seismic Zone
Not applicable.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
9
4. Existing Building Assessment
4.1. Unit or Space Types
All 4,700 square feet of the building are occupied by a single occupant, City of Yorkville – Parks and Recreation. The spaces a
combination of offices, classrooms, supporting restrooms, mechanical, and other utility spaces.
4.2. Inaccessible Areas or Key Spaces Not Observed
The interior spaces were observed in order to gain a clear understanding of the property’s overall condition. Other areas accessed
included the site within the property boundaries, exterior of the property and the roof. Areas of note that were either inaccessible or not
observed for other reasons are listed in the table below:
Key Spaces Not Observed
Room Number Area Access Issues
-- Roof Requires a ladder but due to rain it was unsafe
to climb metal ladder.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
10
5. Site Improvements
5.1. Utilities
The following table identifies the utility suppliers and the condition and adequacy of the services.
Site Utilities
Utility Supplier Condition and Adequacy
Sanitary sewer City of Yorkville Good
Storm sewer City of Yorkville Good
Domestic water City of Yorkville Good
Electric service Commonwealth Edison Good
Natural gas service Nicor Gas Good
Actions/Comments:
According to the occupants, the utilities provided are adequate for the property. There are no unique, onsite utility systems such as
emergency electrical generators, septic systems, water or waste water treatment plants, or propane gas tanks.
5.2. Parking, Paving, and Sidewalks
Item Description
Main Ingress and Egress Hydraulic Avenue
Access from South
Additional Entrances --
Additional Access from --
Paving and Flatwork
Item Material Last Work Done Condition
Entrance Driveway Apron Asphalt >20 Fair
Parking Lot Asphalt >20 Poor
Drive Aisles Asphalt >20 Poor
Service Aisles None -- --
Sidewalks Concrete Approx. 20 Fair
Curbs None -- --
Site Stairs None -- --
Pedestrian Ramps Cast-in-place concrete Approx. 20 Fair
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
11
Parking Count
Open Lot Carport Private Garage Subterranean
Garage
Freestanding Parking
Structure
17 -- -- -- --
Total Number of ADA Compliant Spaces 0
Number of ADA Compliant Spaces for Vans 0
Total Parking Spaces 17
Parking Ratio (Spaces/Apartments) --
Method of Obtaining Parking Count Physical count
Exterior Stairs
Location Material Handrails Condition
None -- -- --
Anticipated Lifecycle Replacements:
Asphalt seal coating
Asphalt pavement
Sidewalks
Pedestrian ramps
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
5.3. Drainage Systems and Erosion Control
Drainage System and Erosion Control
System Exists At Site Condition
Surface Flow ☒ Fair
Inlets ☐ --
Swales ☐ --
Detention pond ☐ --
Lagoons ☐ --
Ponds ☐ --
Underground Piping ☐ --
Pits ☐ --
Municipal System ☐ --
Dry Well ☐ --
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
12
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
There is no evidence of storm water runoff from adjacent properties. The storm water system appears to provide adequate runoff
capacity. There is no evidence of major ponding or erosion.
5.4. Topography and Landscaping
Item Description
Site Topography Slopes gently down towards the adjacent river.
Landscaping
Trees Grass Flower
Beds Planters
Drought
Tolerant
Plants
Decorative
Stone None
☒ ☒ ☐ ☐ ☒ ☐ ☐
Landscaping
Condition Good
Irrigation
Automatic
Underground Drip Hand Watering None
☐ ☐ ☐ ☒
Irrigation Condition --
Retaining Walls
Type Location Condition
None -- --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The topography and adjacent uses do not appear to present conditions detrimental to the property. There are no significant areas of
erosion.
5.5. General Site Improvements
Property Signage
Property Signage Building mounted
Street Address Displayed? Yes
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
13
Site and Building Lighting
Site Lighting
None Pole Mounted Bollard Lights Ground
Mounted
Parking Lot
Pole Type
☒ ☐ ☐ ☐ ☐
--
Building Lighting
None Wall Mounted Recessed Soffit
☐ ☒ ☒
Fair
Site Fencing
Type Location Condition
Stained wood board and posts Rear lot Fair
Chain link with metal posts Rear lot Fair
REFUSE DISPOSAL
Refuse Disposal Common area dumpsters
Dumpster Locations Mounting Enclosure Contracted? Condition
Left side of building Asphalt
paving Wood board fence Yes Fair
Other Site Amenities
Description Location Condition
Playground Equipment Plastic and metal Rear lot Good
Tennis Courts None -- --
Basketball Court None -- --
Swimming Pool None -- --
Anticipated Lifecycle Replacements:
Exterior lighting
Site fencing
Playground equipment
Playground surfaces
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
14
6. Building Architectural and Structural Systems
6.1. Foundations
Building Foundation
Item Description Condition
Foundation Masonry foundation walls Good
Basement and Crawl Space None --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The foundation systems are concealed. There are no significant signs of settlement, deflection, or movement.
6.2. Superstructure
Building Superstructure
Item Description Condition
Framing / Load-Bearing Walls Masonry walls Good
Ground Floor Concrete slab Good
Upper Floor Framing -- --
Upper Floor Decking -- --
Roof Framing Steel beams or girders Good
Roof Decking Metal decking Good
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The superstructure is exposed in some locations, which allows for limited observation. Walls and floors appear to be plumb, level,
and stable. There are no significant signs of deflection or movement.
6.3. Roofing
Primary Roof
Type / Geometry Flat Finish Built-up membrane
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
15
Primary Roof
Maintenance Outside Contractor Roof Age Approximately 20 Yrs
Flashing Built-up base and Edge flashing Warranties No
Parapet Copings Pre-cast Concrete Roof Drains Internal drains
Fascia None Insulation Rigid Board
Soffits Exposed Soffits Skylights No
Attics None Ponding Unknown
Ventilation Source-1 None Leaks Observed No
Ventilation Source-2 -- Roof Condition Fair
Anticipated Lifecycle Replacements:
Built-up roof membrane
Roof flashings (included as part of overall membrane replacement)
Parapet wall copings (included as part of overall membrane replacement)
Actions/Comments:
The roof finishes appear to be more than 20 years old. Information regarding roof warranties or bonds was not available.
According to the POC, there are no active roof leaks. Roof leaks have occurred in the past year. The leaks have since been
repaired, and no active roof leaks are evident
There is no evidence of roof deck or insulation deterioration. The roof substrate and insulation should be inspected during any future
roof repair or replacement work.
Roof drainage appears to be adequate. Clearing and minor repair of drain system components should be performed regularly as part
of the property management’s routine maintenance and operations program.
6.4. Exterior Walls
Building Exterior Walls
Type Location Condition
Primary Finish Brick veneer Good
Secondary Finish Metal siding Fair
Accented with Pre-cast concrete Good
Soffits Exposed Fair
Building sealants (caulking) are located between dissimilar materials, at joints, and around window and door openings.
Anticipated Lifecycle Replacements:
Metal siding
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
16
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance, including patching repairs, graffiti removal,
and re-caulking, is highly recommended. Future lifecycle replacements of the components listed above will be required.
6.5. Exterior and Interior Stairs
Not applicable. There are no exterior or interior stairs.
6.6. Exterior Windows and Doors
Building Windows
Window Framing Glazing Location Window
Screen Condition
Aluminum framed storefront Double glaze Front elevation ☐ Fair
Aluminum framed, operable Single glaze Exterior walls ☐ Poor
Building Doors
Main Entrance Doors Door Type Condition
Fully glazed, metal framed Fair
Secondary Entrance Doors Metal, insulated Fair
Service Doors Metal, insulated Fair
Overhead Doors None --
Anticipated Lifecycle Replacements:
Windows
Storefront glazing
Exterior doors
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
6.7. Patio, Terrace, and Balcony
Not applicable. There are no patios, terraces, or balconies.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
17
7. Building Mechanical and Plumbing Systems
See the Mechanical Equipment List in the Appendices for the quantity, manufacturer’s name, model number, capacity and year of
manufacturer of the major mechanical equipment, if available.
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC)
Individual Units
Primary Components Split system furnaces and condensing units
Cooling (if separate from above) performed via components above
Quantity and Capacity Ranges 2 units at 5 tons each
Total Heating or Cooling Capacity 10 tons
Heating Fuel Natural gas
Location of Equipment Mechanical rooms
Space Served by System Entire building
Age Ranges Vary from 2000 to 2014
Primary Component Condition Good to Fair
Controls and Ventilation
HVAC Control System Individual programmable thermostats/controls
HVAC Control System Condition Good
Building Ventilation Roof top exhaust fans
Ventilation System Condition Good
Anticipated Lifecycle Replacements:
Split system furnaces and condensing units
Rooftop exhaust fans
Actions/Comments:
The HVAC systems are maintained by the in-house maintenance staff.
The HVAC equipment varies in age. HVAC equipment is replaced on an "as needed" basis.
The HVAC equipment appears to be functioning adequately overall. However, due to the inevitable failure of parts and components
over time, the equipment will require replacement. A budgetary cost for this work is included.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
18
7.2. Building Plumbing and Domestic Hot Water
Building Plumbing System
Type Description Condition
Water Supply Piping Copper Fair
Waste/Sewer Piping Cast iron Fair
Vent Piping PVC Fair
Water Meter Location Mechanical room
Domestic Water Heaters or Boilers
Components Water Heater
Fuel Natural gas
Quantity and Input Capacity 1 unit at 32,000 BTUH
Storage Capacity 40 gallons
Boiler or Water Heater Condition Fair
Supplementary Storage Tanks? No
Storage Tank Quantity & Volume --
Quantity of Storage Tanks --
Storage Tank Condition --
Domestic Hot Water Circulation Pumps (3 HP and over) No
Adequacy of Hot Water Adequate
Adequacy of Water Pressure Adequate
Plumbing Fixtures
Water Closets Commercial
Toilet (Water Closet) Flush Rating 1.6 GPF
Common Area Faucet Nominal Flow Rate 2.0 GPM
Condition Good
Anticipated Lifecycle Replacements:
Water heater
Toilets
Urinals
Sink
Lavatory
Actions/Comments:
The plumbing systems appear to be well maintained and functioning adequately. The water pressure appears to be sufficient. No
significant repair actions or short term replacement costs are required. Routine and periodic maintenance is recommended. Future
lifecycle replacements of the components or systems listed above will be required.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
19
7.3. Building Gas Distribution
Gas service is supplied from the gas main on the adjacent public street. The gas meter and regulator are located along the exterior
wall of the building. The gas distribution piping within the building is malleable steel (black iron).
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The pressure and quantity of gas appear to be adequate.
The gas meter and regulator appear to be functioning adequately and will require routine maintenance.
Only limited observation of the gas distribution piping can be made due to hidden conditions.
7.4. Building Electrical
Building Electrical Systems
Electrical Lines Overhead Transformer Pole-mounted
Main Service Size 200 Amps Volts 120/208 Volt, three-phase
Meter & Panel Location Rear elevation Branch Wiring Copper
Conduit Metallic Step-Down
Transformers? No
Security / Surveillance
System? No Building Intercom
System? No
Lighting Fixtures T-8
Main Distribution Condition Fair
Secondary Panel and
Transformer Condition --
Lighting Condition Fair
Anticipated Lifecycle Replacements:
Circuit breaker panels
Interior light fixtures
Actions/Comments:
The onsite electrical systems up to the meters are owned and maintained by the respective utility company.
The electrical service and capacity appear to be adequate for the property’s demands.
The panels are original 1985 components. The electrical service is reportedly adequate for the facility’s needs. However, due to the
age of the panels and increasing difficulty of obtaining replacement parts over time, lifecycle replacements are recommended per
above.
7.5. Building Elevators and Conveying Systems
Not applicable. There are no elevators or conveying systems.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
20
7.6. Fire Protection and Security Systems
Item Description
Type None
Fire Alarm System
Central Alarm Panel ☐ Battery-Operated Smoke
Detectors ☒ Alarm Horns ☐
Annunciator Panels ☐ Hard-Wired Smoke
Detectors ☐ Strobe Light Alarms ☐
Pull Stations ☐ Emergency Battery-Pack
Lighting ☒ Illuminated EXIT Signs ☒
Alarm System
Condition Fair
Sprinkler System
None ☒ Standpipes ☐ Backflow Preventer ☐
Hose Cabinets ☐ Fire Pumps ☐ Siamese Connections ☐
Suppression
Condition --
Central Alarm Panel
System
Location of Alarm Panel Installation Date of Alarm Panel
-- --
Fire Extinguishers
Last Service Date Servicing Current?
May 2017 Yes
Hydrant Location Hydraulic Avenue
Siamese Location --
Special Systems Kitchen Suppression System ☐ Computer Room Suppression System ☐
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The building is not protected by fire suppression. Due to its construction date, the facility is most likely “grandfathered” by code and
the installation of fire sprinklers not required until major renovations are performed. Regardless of when or if installation of facility-
wide fire suppression is required by the governing municipality, EMG recommends a retrofit be performed. A budgetary cost is
included.
The fire alarm systems appear somewhat antiquated and not up to current standards. There is a lack of strobes, audio alarms,
insufficient pull stations, and system not fully addressable. Due to the age of the components and apparent shortcomings, a full
modernization project is recommended. A budgetary cost is included.
7.7. Life Support Systems
Not applicable.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
21
8. I nterior Spaces
8.1. I nterior Finishes
The facility is used as a pre-school and an office building for the Department of Parks and Recreation.
The most significant interior spaces include classrooms and offices. Supporting areas include restrooms, storage rooms, and
mechanical rooms.
The following table generally describes the locations and typical conditions of the interior finishes within the facility:
Typical Floor Finishes
Floor Finish Locations General Condition
Carpet Offices and classrooms Fair
Vinyl tile Mechanical room Fair
Ceramic tile Lobby and restrooms Good
Typical Wall Finishes
Wall Finish Locations General Condition
Painted drywall Throughout the building Fair
Painted CMU Throughout the building Fair
Typical Ceiling Finishes
Ceiling Finish Locations General Condition
Suspended T-bar (Acoustic) Throughout the building Fair
Painted drywall Restrooms Fair
Exposed structure Storage room Poor
Interior Doors
Item Type Condition
Interior Doors Hollow core wood & steel Fair
Door Framing Metal Fair
Fire Doors Yes Fair
Anticipated Lifecycle Replacements:
Carpet
Vinyl tile
Ceramic tile
Interior paint
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
22
Suspended acoustic ceiling tile
Interior doors
Kitchenette appliances
Actions/Comments:
The interior areas were last renovated in past 5 years.
The ceiling tiles have isolated areas of water-damaged ceilings. The damaged ceiling tiles need to be replaced. The cost to replace
the damaged finishes is relatively insignificant and the work can be performed as part of the property management’s routine
maintenance program.
Paint on the exposed structure is worn and chipping in the storage room.
8.2. Commercial Kitchen & Laundry Equipment
Not applicable.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
23
9. Other Structures
Not applicable. There are no major accessory structures.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
24
10. Certification
City of Yorkville retained EMG to perform this Facility Condition Assessment in connection with its continued operation of Park and
Recreation Office, 201 West Hydraulic Avenue, Yorkville, IL, the “Property”. It is our understanding that the primary interest of City of
Yorkville is to locate and evaluate materials and building system defects that might significantly affect the value of the property and to
determine if the present Property has conditions that will have a significant impact on its continued operations.
The conclusions and recommendations presented in this report are based on the brief review of the plans and records made available
to our Project Manager during the site visit, interviews of available property management personnel and maintenance contractors
familiar with the Property, appropriate inquiry of municipal authorities, our Project Manager’s walk-through observations during the site
visit, and our experience with similar properties.
No testing, exploratory probing, dismantling or operating of equipment or in depth studies were performed unless specifically required
under Section 2 of this report. This assessment did not include engineering calculations to determine the adequacy of the Property’s
original design or existing systems. Although walk-through observations were performed, not all areas were observed (See Section 4.2
for areas observed). There may be defects in the Property, which were in areas not observed or readily accessible, may not have been
visible, or were not disclosed by management personnel when questioned. The report describes property conditions at the time that
the observations and research were conducted.
This report has been prepared on behalf of and exclusively for the use of City of Yorkville for the purpose stated within Section 2 of this
report. The report, or any excerpt thereof, shall not be used by any party other than City of Yorkville or for any other purpose than that
specifically stated in our agreement or within Section 2 of this report without the express written consent of EMG.
Any reuse or distribution of this report without such consent shall be at City of Yorkville and the recipient’s sole risk, without liability to
EMG.
Prepared by: Paul Prusa P.E., LEED AP
Project Manager
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
25
11. Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: Supporting Documentation
Appendix D: EMG Accessibility Checklist
Appendix E: Pre-Survey Questionnaire
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
Appendix A:
Photographic Record
Park & Rec Office
201 West Hydraulic Avenue
Yorkville, IL 60560 EMG PROJECT NO: 122700.17R000-011.322
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: RIGHT ELEVATION
#3: LEFT ELEVATION
#4: REAR ELEVATION
#5: PARKING LOTS, ASPHALT
PAVEMENT
#6: SIDEWALK, CLAY
BRICK/MASONRY PAVERS
Park & Rec Office
201 West Hydraulic Avenue
Yorkville, IL 60560 EMG PROJECT NO: 122700.17R000-011.322
www.EMGcorp.com p 800.733.0660
#7: PEDESTRIAN PAVEMENT,
SIDEWALK, CONCRETE
#8: FENCES & GATES, WOOD
BOARD
#9: FENCES & GATES, CHAIN LINK
#10: PLAY STRUCTURE, PRE-
SCHOOL
#11: EXTERIOR WALL, ALUMINUM
SIDING
#12:
EXTERIOR DOOR, FULLY-
GLAZED ALUMINUM-FRAMED
SWINGING MOTOR-OPERATED
Park & Rec Office
201 West Hydraulic Avenue
Yorkville, IL 60560 EMG PROJECT NO: 122700.17R000-011.322
www.EMGcorp.com p 800.733.0660
#13: EXTERIOR DOOR, STEEL
#14: STOREFRONT, METAL-FRAMED
WINDOWS
#15: WINDOW, ALUMINUM DOUBLE-
GLAZED AWNING
#16: WINDOW, ALUMINUM DOUBLE-
GLAZED, SMALL
#17: CONDENSING UNIT, SPLIT
SYSTEM
#18: AIR HANDLER, INTERIOR
Park & Rec Office
201 West Hydraulic Avenue
Yorkville, IL 60560 EMG PROJECT NO: 122700.17R000-011.322
www.EMGcorp.com p 800.733.0660
#19: TOILET, TANKLESS (WATER
CLOSET)
#20: LAVATORY, VITREOUS CHINA
#21: SINK, STAINLESS STEEL
#22: WATER HEATER, GAS
#23: LIGHTING SYSTEM, INTERIOR
#24: METAL HALIDE LIGHTING
FIXTURE
Park & Rec Office
201 West Hydraulic Avenue
Yorkville, IL 60560 EMG PROJECT NO: 122700.17R000-011.322
www.EMGcorp.com p 800.733.0660
#25: HIGH PRESSURE SODIUM
LIGHTING FIXTURE
#26: COMPACT FLUORESCENT
LIGHTING FIXTURE
#27: MAIN DISTRIBUTION PANEL
#28: FIRE EXTINGUISHER
#29: EMERGENCY/EXIT COMBO
#30: KITCHEN CABINET, BASE AND
WALL SECTION, WOOD
Park & Rec Office
201 West Hydraulic Avenue
Yorkville, IL 60560 EMG PROJECT NO: 122700.17R000-011.322
www.EMGcorp.com p 800.733.0660
#31: INTERIOR DOOR, STEEL
#32: INTERIOR DOOR, WOOD
HOLLOW-CORE
#33: INTERIOR DOOR, BI-FOLD
#34: INTERIOR DOOR, FULLY-GLAZED
ALUMINUM-FRAMED SWINGING
#35: INTERIOR CEILING FINISH,
PAINTED STRUCTURE
#36: INTERIOR WALL FINISH, CMU
Park & Rec Office
201 West Hydraulic Avenue
Yorkville, IL 60560 EMG PROJECT NO: 122700.17R000-011.322
www.EMGcorp.com p 800.733.0660
#37: INTERIOR WALL FINISH,
GYPSUM BOARD
#38: INTERIOR CEILING FINISH,
ACOUSTICAL TILE (ACT)
#39: STAINED ACOUSTICAL CEILING
TILE
#40: INTERIOR FLOOR FINISH,
CERAMIC TILE
#41: INTERIOR FLOOR FINISH, VINYL
TILE (VCT)
#42:
INTERIOR FLOOR FINISH,
CARPET STANDARD-
COMMERCIAL MEDIUM-TRAFFIC
Park & Rec Office
201 West Hydraulic Avenue
Yorkville, IL 60560 EMG PROJECT NO: 122700.17R000-011.322
www.EMGcorp.com p 800.733.0660
#43: INTERIOR WINDOW
#44: RESIDENTIAL APPLIANCES,
REFRIGERATOR
#45: INTERIOR DOOR, FIRE 90-
MINUTES AND OVER
#46: INTERIOR DOOR, FULLY-GLAZED
WOOD-FRAMED
#47: STORAGE SHED
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
Appendix B:
Site Plan
Site Plan
Project Name:
Park & Rec Office
Project Number:
122700.17R000-011.322
Source:
Google Maps
On-Site Date:
May 23, 2017
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
Appendix C:
Supporting Documentation
www.EMGcorp.com p 800.733.0660
THIS APPENDIX INTENTIONALLY
LEFT BLANK
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
Appendix D:
EMG Accessibility Checklist
Page 1 of 4
Date Completed: June 30, 2017
Property Name: Park & Rec Office
EMG Project Number: 122700.17R000-011.322
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
Page 3 of 4
Elevators (cont.) Yes No NA Comments
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
Toilet Rooms (cont.) Yes No NA Comments
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Page 4 of 4
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
Appendix E:
Pre-Survey Questionnaire
1
PP RR OO PP EE RR TT YY CC OO NN DD II TT II OO NN AA SS SS EE SS SS MM EE NN TT :: PP RR EE --SS UU RR VV EE YY QQ UU EE SS TT II OO NN NN AA II RR EE
This questionnaire must be completed by the property owner, the owner's designated representative, or someone knowledgeable about
the subject property. The completed form must be presented to EMG's Field Observer on the day of the site visit. If the form is not
completed, EMG’s Project Manager will require additional time during the on-site visit with such a knowledgeable person in order to
complete the questionnaire. During the site visit, EMG's Field Observer may ask for details associated with selected questions. This
questionnaire will be utilized as an exhibit in EMG's final Property Condition Report.
Name of person completing
questionnaire:
Association with property:
Length of association with property:
Date Completed:
Phone Number:
Property Name:
EMG Project Number:
Directions: Please answer all questions to the best of your knowledge and in good faith. Please provide additional details in the
Comments column, or backup documentation for any Yes responses.
INSPECTIONS DATE LAST
INSPECTED
LIST ANY OUTSTANDING REPAIRS REQUIRED
1 Elevators
2 HVAC,
Mechanical,
Electric,
Plumbing
3 Life-Safety/Fire
4 Roofs
QUESTION RESPONSE
5
List any major capital improvement
within the last three years.
6
List any major capital expenditures
planned for the next year.
7
What is the age of the roof(s)?
8
What building systems (HVAC, roof,
interior/exterior finishes, paving, etc.)
are the responsibilities of the tenant
to maintain and replace?
2
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION RESPONSE COMMENTS
Y N Unk NA
9 Are there any unresolved building,
fire, or zoning code issues?
10 Are there any "down" or unusable
units?
11 Are there any problems with
erosion, stormwater drainage or
areas of paving that do not drain?
12 Is the property served by a private
water well?
13 Is the property served by a private
septic system or other waste
treatment systems?
14 Are there any problems with
foundations or structures?
15 Is there any water infiltration in
basements or crawl spaces?
16 Are there any wall, or window
leaks?
17 Are there any roof leaks?
18 Is the roofing covered by a
warranty or bond?
19 Are there any poorly insulated
areas?
20 Is Fire Retardant Treated (FRT)
plywood used?
21 Is exterior insulation and finish
system (EIFS) or a synthetic
stucco finish used?
22 Are there any problems with the
utilities, such as inadequate
capacities?
23 Are there any problems with the
landscape irrigation systems?
24 Has a termite/wood boring insect
inspection been performed within
the last year?
25 Do any of the HVAC systems use
R-11, 12, or 22 refrigerants?
26 Has any part of the property ever
contained visible suspect suspect
fungal growth growth?
3
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION RESPONSE COMMENTS
Y N Unk NA
27 Is there a suspect fungal growth
Operations and Maintenance
Plan?
28 Have there been indoor air quality
or suspect fungal growth related
complaints from tenants?
29 Is polybutylene piping used?
30 Are there any plumbing leaks or
water pressure problems?
31 Are there any leaks or pressure
problems with natural gas service?
32 Does any part of the electrical
system use aluminum wiring?
33 Do Residential units have a less
than 60-Amp service?
34 Do Commercial units have less
than 200-Amp service?
35 Are there any recalled fire sprinkler
heads (Star, GEM, Central,
Omega)?
36 Is there any pending litigation
concerning the property?
37 Has the management previously
completed an ADA review?
38 Have any ADA improvements
been made to the property?
39 Does a Barrier Removal Plan exist
for the property?
40 Has the Barrier Removal Plan
been approved by an arms-length
third party?
41 Has building ownership or
management received any ADA
related complaints?
42 Does elevator equipment require
upgrades to meet ADA standards?
43 Are there any problems with
exterior lighting?
44 Are there any other significant
issues/hazards with the property?
4
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION RESPONSE COMMENTS
Y N Unk NA
45 Are there any unresolved
construction defects at the
property?
_______________________________________________________________________________
Signature of person Interviewed or completing form Date
5
PP RR OO PP EE RR TT YY CC OO NN DD II TT II OO NN AA SS SS EE SS SS MM EE NN TT :: DD OO CC UU MM EE NN TT RR EE QQ UU EE SS TT
On the day of the site visit, provide EMG's Field Observer access to all of the available documents listed below.
Provide copies if possible.
Your timely compliance with this request is greatly appreciated.
All available construction documents (blueprints) for the original construction of the building or for any tenant
improvement work or other recent construction work.
A site plan, preferably 8 1/2" X 11", which depicts the arrangement of buildings, roads, parking stalls, and
other site features.
For commercial properties, provide a tenant list which identifies the names of each tenant, vacant tenant
units, the floor area of each tenant space, and the gross and net leasable area of the building(s).
For apartment properties, provide a summary of the apartment unit types and apartment unit type
quantities, including the floor area of each apartment unit as measured in square feet.
For hotel or nursing home properties, provide a summary of the room types and room type quantities.
Copies of Certificates of Occupancy, building permits, fire or health department inspection reports, elevator
inspection certificates, roof or HVAC warranties, or any other similar, relevant documents.
The names of the local utility companies which serve the property, including the water, sewer, electric, gas,
and phone companies.
The company name, phone number, and contact person of all outside vendors who serve the property,
such as mechanical contractors, roof contractors, fire sprinkler or fire extinguisher testing contractors, and
elevator contractors.
A summary of recent (over the last 5 years) capital improvement work which describes the scope of the
work and the estimated cost of the improvements. Executed contracts or proposals for improvements.
Historical costs for repairs, improvements, and replacements.
Records of system & material ages (roof, MEP, paving, finishes, and furnishings).
Any brochures or marketing information.
Appraisal, either current or previously prepared.
Current occupancy percentage and typical turnover rate records (for commercial and apartment properties).
Previous reports pertaining to the physical condition of property.
ADA survey and status of improvements implemented.
Current / pending litigation related to property condition.
PARK & REC OFFICE EMG PROJECT NO.: 122700.17R000-011.322
On the day of the site visit, provide EMG's Field Observer access to all of the available documents listed below.
Provide copies if possible.
INFORMATION REQUIRED
1. All available construction documents (blueprints) for
the original construction of the building or for any tenant
improvement work or other recent construction work.
2. A site plan, preferably 8 1/2" X 11", which depicts the
arrangement of buildings, roads, parking stalls, and other
site features.
3. For commercial properties, provide a tenant list which
identifies the names of each tenant, vacant tenant units,
the floor area of each tenant space, and the gross and
net leasable area of the building(s).
4. For apartment properties, provide a summary of the
apartment unit types and apartment unit type quantities,
including the floor area of each apartment unit as
measured in square feet.
5. For hotel or nursing home properties, provide a
summary of the room types and room type quantities.
6. Copies of Certificates of Occupancy, building permits,
fire or health department inspection reports, elevator
inspection certificates, roof or HVAC warranties, or any
other similar, relevant documents.
7. The names of the local utility companies which serve
the property, including the water, sewer, electric, gas,
and phone companies.
8. The company name, phone number, and contact
person of all outside vendors who serve the property,
such as mechanical contractors, roof contractors, fire
sprinkler or fire extinguisher testing contractors, and
elevator contractors.
9. A summary of recent (over the last 5 years) capital
improvement work which describes the scope of the
work and the estimated cost of the improvements.
Executed contracts or proposals for improvements.
Historical costs for repairs, improvements, and
replacements.
10. Records of system & material ages (roof, MEP,
paving, finishes, furnishings).
11. Any brochures or marketing information.
12. Appraisal, either current or previously prepared.
13. Current occupancy percentage and typical turnover
rate records (for commercial and apartment properties).
14. Previous reports pertaining to the physical condition
of property.
15. ADA survey and status of improvements
implemented.
16. Current / pending litigation related to property
condition.
Your timely compliance with this request is greatly appreciated.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Non- Rice Park Shelter
545 Poplar Drive
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-012.366 June 29, 2017 May 22, 2017
FACILITY CONDITION ASSESSMENT
NON- RICE PARK SHELTER EMG PROJECT NO.: 122700.17R000-012.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
NON- RICE PARK SHELTER EMG PROJECT NO.: 122700.17R000-012.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 545 Poplar Drive, Yorkville, Kendall, Illinois 60560
Year Constructed/Renovated: 2004
Current Occupants: City of Yorkville – Parks and Recreation
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Park
Site Area: 1.05 acres
Building Area: 256 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: No associated parking lots. Street parking only.
Building Construction: Steel frame with wood sub-roofing
Roof Construction: Pyramid roof with metal roof finish
Exterior Finishes: Painted structure
Heating, Ventilation and Air Conditioning: Not applicable
Fire and Life/Safety: Hydrants
Dates of Visit: May 22, 2017
On-Site Point of Contact (POC): Scott Sleezer
Assessment and Report Prepared by: Paul Prusa
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Good HVAC --
Structure Good Plumbing Fair
Roof Good Electrical Fair
Vertical Envelope -- Elevators --
Interiors -- Fire --
NON- RICE PARK SHELTER EMG PROJECT NO.: 122700.17R000-012.366
2
www.EMGcorp.com p 800.733.0660
The following bullet points highlight the most significant short term and modernization recommendations:
No significant short term and modernization recommendations
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first constructed and is in good overall condition.
According to property management personnel, the property has had an active capital improvement expenditure program over the past
three years, primarily consisting of exterior painting, asphalt pavement seal coating, and playground surface maintenance. Supporting
documentation was not provided in support of these claims but some of the work is evident.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
NON- RICE PARK SHELTER EMG PROJECT NO.: 122700.17R000-012.366
3
www.EMGcorp.com p 800.733.0660
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.0% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 216% --
Current Replacement Value (CRV) 256 SF * 183.24 / SF = $46,909
Year 0 (Current Year) - Immediate Repairs (IR) $0.00
Years 1-10 – Replacement Reserves (RR) $101,565
Total Capital Needs $101,565
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
No immediate repair costs were observed.
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
NON- RICE PARK SHELTER EMG PROJECT NO.: 122700.17R000-012.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: ADA Checklist
NON- RICE PARK SHELTER EMG PROJECT NO.: 122700.17R000-012.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
Non- Rice Park Shelter EMG PROJECT NO: 122700.17R000-012.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: REAR ELEVATION
#3: PEDESTRIAN PAVEMENT,
SIDEWALK, CONCRETE
#4: PEDESTRIAN PAVEMENT,
SIDEWALK, ASPHALT
#5: PEDESTRIAN PAVEMENT,
MINOR CRACKING
#6: RETAINING WALL,
BRICK/STONE
Non- Rice Park Shelter EMG PROJECT NO: 122700.17R000-012.366
www.EMGcorp.com p 800.733.0660
#7: POLE LIGHT, EXTERIOR,
DECORATIVE
#8: TRAFFIC LIGHT
#9: PLAY SURFACES, WOOD CHIPS
#10: PLAY SURFACES, SAND
#11: PLAY STRUCTURE, LARGE
#12: PLAY STRUCTURE, SWING SET
Non- Rice Park Shelter EMG PROJECT NO: 122700.17R000-012.366
www.EMGcorp.com p 800.733.0660
#13: PICNIC TABLE, COMPOSITE
#14: PARK BENCH,
METAL/WOOD/PLASTIC
#15: STRUCTURAL FRAME, STEEL
COLUMNS & BEAMS
#16: CHIPPED PAINT AND
CORROSION
#17: ROOF, METAL
NON- RICE PARK SHELTER EMG PROJECT NO.: 122700.17R000-012.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Non- Rice Park Shelter
Project Number:
122700.17R000-012.366
Source:
Google Maps
On-Site Date:
May 22, 2017
NON- RICE PARK SHELTER EMG PROJECT NO.: 122700.17R000-012.366
www.EMGcorp.com p 800.733.0660
Appendix C:
ADA Checklist
Page 1 of 4
Date Completed: June 13, 2017
Property Name:Non- Rice Park Shelter
EMG Project Number: 122700.17R000-012.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X All parks are CPSC, ADA and ASTM
compliant per the POC.
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
River Front Park Pavilion
201 East Hydraulic Street
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-014.366 June 30, 2017 May 22, 2017
FACILITY CONDITION ASSESSMENT
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
RIVER FRONT PARK PAVILION EMG PROJECT NO.: 122700.17R000-014.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
RIVER FRONT PARK PAVILION EMG PROJECT NO.: 122700.17R000-014.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 201 East Hydraulic Street, Yorkville, Kendall, IL 60560
Year Constructed/Renovated: 1999
Current Occupants: City of Yorkville – Parks and Recreation
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Park Pavilion
Site Area: 0.05 acres
Building Area: 2,400 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: Parking included in separate report, Riverfront Park.
Building Construction: Steel frame
Roof Construction: Gabled roof with metal roof finish
Exterior Finishes: Painted structure
Heating, Ventilation and Air Conditioning: Not applicable
Fire and Life/Safety: Hydrants
Dates of Visit: May 22, 2017
On-Site Point of Contact (POC): Scott Sleezer
Assessment and Report Prepared by: Paul Prusa
Reviewed by:
Al Diefert
Technical Report Reviewer For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Good HVAC --
Structure Good Plumbing --
Roof Good Electrical --
Vertical Envelope -- Elevators --
Interiors -- Fire --
RIVER FRONT PARK PAVILION EMG PROJECT NO.: 122700.17R000-014.366
2
www.EMGcorp.com p 800.733.0660
The following bullet points highlight the most significant short term and modernization recommendations:
Repair loose and missing stones.
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in good overall condition.
According to property management personnel, the property has had an active capital improvement expenditure program over the past
three years, primarily consisting of exterior painting. Supporting documentation was not provided in support of these claims but some
of the work is evident.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
RIVER FRONT PARK PAVILION EMG PROJECT NO.: 122700.17R000-014.366
3
www.EMGcorp.com p 800.733.0660
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.0% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 1.6% Good
Current Replacement Value (CRV) 500 SF * 183.24 / SF = $91,620
Year 0 (Current Year) - Immediate Repairs (IR) $78
Years 1-10 – Replacement Reserves (RR) $1,478
Total Capital Needs $1,556
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Repair loose and missing stones.
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
RIVER FRONT PARK PAVILION EMG PROJECT NO.: 122700.17R000-014.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: ADA Checklist
RIVER FRONT PARK PAVILION EMG PROJECT NO.: 122700.17R000-014.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
RIVER FRONT PARK PAVILION EMG PROJECT NO: 122700.17R000-014.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: RIGHT ELEVATION
#3: LEFT ELEVATION
#4: REAR ELEVATION
#5: PEDESTRIAN PAVEMENT,
SIDEWALK, CONCRETE
#6: STRUCTURAL FRAME, STEEL
COLUMNS & BEAMS
RIVER FRONT PARK PAVILION EMG PROJECT NO: 122700.17R000-014.366
www.EMGcorp.com p 800.733.0660
#7: PAINTED SURFACES
#8: PAINTED SURFACE, SURFACE
CORROSION
#9: ROOF, METAL
#10: STAIRS, CLAY BRICK/MASONRY
PAVERS
#11: STAIR, MISSING BRICK
#12:
CLAY BRICK/MASONRY
PAVERS, MISSING AND
DISLODGED BRICKS
RIVER FRONT PARK PAVILION EMG PROJECT NO.: 122700.17R000-014.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
River Front Park Pavilion
Project Number:
122700.17R000-014.366
Source:
Google Maps
On-Site Date:
May 22, 2017
RIVER FRONT PARK PAVILION EMG PROJECT NO.: 122700.17R000-014.366
www.EMGcorp.com p 800.733.0660
Appendix C:
ADA Checklist
Page 1 of 4
Date Completed: June 14, 2017
Property Name: River Front Park Pavilion
EMG Project Number: 122700.17R000-014.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
River Front Park
201 East Hydraulic Street
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-015.366 June 30, 2017 May 23, 2017
FACILITY CONDITION ASSESSMENT
RIVER FRONT PARK EMG PROJECT NO.: 122700.17R000-015.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
RIVER FRONT PARK EMG PROJECT NO.: 122700.17R000-015.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 201 East Hydraulic Street, Yorkville, Kendall, Illinois 60560
Year Constructed/Renovated: 1999
Current Occupants: City of Yorkville – Parks and Recreation
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Park
Site Area: 2.04 acres
Building Area: Not applicable
Number of Buildings: Not applicable
Number of Stories: Not applicable
Parking Type and Number of Spaces: 40 spaces in open lots
Building Construction: Not applicable
Roof Construction: Not applicable
Exterior Finishes: Not applicable
Heating, Ventilation and Air Conditioning: Not applicable
Fire and Life/Safety: Hydrants
Dates of Visit: May 23, 2017
On-Site Point of Contact (POC): Scott Sleezer
Assessment and Report Prepared by: Paul Prusa
Reviewed by:
Al Diefert
Technical Report Reviewer
For
Andrew Hupp
Program Manager
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Good HVAC --
Structure -- Plumbing Fair
Roof -- Electrical Fair
Vertical Envelope -- Elevators --
Interiors -- Fire --
RIVER FRONT PARK EMG PROJECT NO.: 122700.17R000-015.366
2
www.EMGcorp.com p 800.733.0660
The following bullet points highlight the most significant short term and modernization recommendations:
Parking lot seal and stripe
Repair of concrete retaining wall
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained in recent years and is in fair overall condition.
According to property management personnel, the property has had a limited capital improvement expenditure program over the past
three years, primarily consisting of asphalt pavement seal coating. Supporting documentation was not provided in support of these
claims but some of the work is evident.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
RIVER FRONT PARK EMG PROJECT NO.: 122700.17R000-015.366
3
www.EMGcorp.com p 800.733.0660
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 45.7% Poor
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 161% --
Current Replacement Value (CRV) 500 SF * 183.24 / SF = $91,619
Year 0 (Current Year) - Immediate Repairs (IR) $41,907
Years 1-10 – Replacement Reserves (RR) $147,516
Total Capital Needs $189,423
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Parking lot seal and stripe
Repair of concrete retaining wall
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
RIVER FRONT PARK EMG PROJECT NO.: 122700.17R000-015.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plans
Appendix C: Pre-Survey Questionnaire
Appendix D: ADA Checklist
RIVER FRONT PARK EMG PROJECT NO.: 122700.17R000-015.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
RIVER FRONT PARK EMG PROJECT NO: 122700.17R000-015.366
www.EMGcorp.com p 800.733.0660
#1: MAIN PARK ENTRY
#2: BRIDGE
#3: PEDESTRIAN PAVEMENT,
SIDEWALK, ASPHALT
#4: SIDEWALK, CLAY
BRICK/MASONRY PAVERS
#5: SIDEWALK, DISPLACED
PAVERS
#6: SIDEWALK, DEPRESSED
PAVERS
RIVER FRONT PARK EMG PROJECT NO: 122700.17R000-015.366
www.EMGcorp.com p 800.733.0660
#7: PARKING LOTS, ASPHALT
PAVEMENT
#8: RETAINING WALL, CAST-IN-
PLACE CONCRETE
#9: RETAINING WALL,
BRICK/STONE
#10: POLE LIGHT, EXTERIOR,
BRIDGE
#11: FLAGPOLE, METAL
#12: EMERGENCY CALL
STATION/DEFIBRILLATOR
RIVER FRONT PARK EMG PROJECT NO: 122700.17R000-015.366
www.EMGcorp.com p 800.733.0660
#13: FENCES, WOOD BOARD
#14: SIGNAGE, PROPERTY,
MONUMENT/PYLON
#15: FENCES, WROUGHT IRON, 4'
HIGH
#16: FENCES, DAMAGED
#17: SITE FURNISHINGS, PARK
BENCH, METAL/WOOD/PLASTIC
#18: EXTERIOR STAIRS, CONCRETE
RIVER FRONT PARK EMG PROJECT NO: 122700.17R000-015.366
www.EMGcorp.com p 800.733.0660
#19: DRINKING FOUNTAIN,
REFRIGERATED
#20: ANCILLARY BUILDING
#21: ANCILLARY BUILDING
RIVER FRONT PARK EMG PROJECT NO.: 122700.17R000-015.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
River Front Park
Project Number:
122700.17R000-015.366
Source:
Google Maps
On-Site Date:
May 23, 2017
RIVER FRONT PARK EMG PROJECT NO.: 122700.17R000-015.366
www.EMGcorp.com p 800.733.0660
Appendix C:
Pre-Survey Questionnaire
PROPERTY CONDITION ASSESSMENT : PRE-SURVEY QUESTIONNAIRE
Name of Person Completing Questionnaire:N/A - Not returned to EMG
Association with Property:
Length of Assocation with Property:
Date Completed:
Phone Number:
Property Name:
EMG Project Number:
Inspections Date Last
Inspected
List any Outstanding Repairs Required
1 Elevators
2 HVAC, Mechanical,
Electric, Plumbing
3 Life-Safety/Fire
4 Roofs
Question Response
5 List any major capital improvement within
the last three years.
6 List any major capital expenditures
planned for the next year.
7 What is the age of the roof(s)?
8 What building systems (HVAC, roof,
interior/exterior finishes, paving, etc.) are
the responsibilities of the tenant to
maintain and replace?
Question Yes No Unk N/A Comments
9
Are there any unresolved building, fire, or
zoning code issues?
10 Are there any "down" or unusable units?
11
Are there any problems with erosion,
stormwater drainage or areas of paving that
do not drain?
12
Is the property served by a private water
well?
13
Is the property served by a private septic
system or other waste treatment systems?
14
Are there any problems with foundations or
structures?
15
Is there any water infiltration in basements or
crawl spaces?
16 Are there any wall, or window leaks?
17 Are there any roof leaks?
18 Is the roofing covered by a warranty or bond?
19 Are there any poorly insulated areas?
20
Is Fire Retardant Treated (FRT) plywood
used?
PROPERTY CONDITION ASSESSMENT : PRE-SURVEY QUESTIONNAIRE
Question Yes No Unk N/A Comments
21
Is exterior insulation and finish system (EIFS)
or a synthetic stucco finish used?
22
Are there any problems with the utilities, such
as inadequate capacities?
23
Are there any problems with the landscape
irrigation systems?
24
Has a termite/wood boring insect inspection
been performed within the last year?
25
Do any of the HVAC systems use R-11, 12,
or 22 refrigerants?
26
Has any part of the property ever contained
visible suspect mold growth?
27
Is there a mold Operations and Maintenance
Plan?
28
Have there been indoor air quality or mold
related complaints from tenants?
29 Is polybutylene piping used?
30
Are there any plumbing leaks or water
pressure problems?
31
Are there any leaks or pressure problems
with natural gas service?
32
Does any part of the electrical system use
aluminum wiring?
33
Do Residential units have a less than
60-Amp service?
34
Do Commercial units have less than
200-Amp service?
35
Are there any recalled fire sprinkler heads
(Star, GEM, Central, Omega)?
36
Is there any pending litigation concerning the
property?
37
Has the management previously completed
an ADA review?
38
Have any ADA improvements been made to
the property?
39
Does a Barrier Removal Plan exist for the
property?
40
Has the Barrier Removal Plan been approved
by an arms-length third party?
41
Has building ownership or management
received any ADA related complaints?
42
Does elevator equipment require upgrades to
meet ADA standards?
43 Are there any problems with exterior lighting?
44
Are there any other significant
issues/hazards with the property?
PROPERTY CONDITION ASSESSMENT : PRE-SURVEY QUESTIONNAIRE
Question Yes No Unk N/A Comments
45
Are there any unresolved construction
defects at the property?
Comments
RIVER FRONT PARK EMG PROJECT NO.: 122700.17R000-015.366
www.EMGcorp.com p 800.733.0660
Appendix D:
ADA Checklist
Page 1 of 4
Date Completed: June 13, 2017
Property Name: River Front Park
EMG Project Number: 122700.17R000-015.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X Per the POC all parks are CPSC, ADA, and
ASTM compliant.
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
3
Does the width between railings appear at
least 36 inches? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms (cont.) Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Booster PRV Station
1908 Raintree Road
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-021.366 June 29, 2017 May 24, 2017
FACILITY CONDITION ASSESSMENT
BOOSTER PRV STATION EMG PROJECT NO.: 122700.17R000-021.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
BOOSTER PRV STATION EMG PROJECT NO.: 122700.17R000-021.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 1908 Raintree Road, Yorkville, Illinois 60560
Year Constructed/Renovated: 2005
Current Occupants: City of Yorkville
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us
Property Type: Booster PRV Station
Site Area: 0.1 acres
Building Area: 380 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: Driveway
Building Construction: Masonry bearing walls and wood-framed roofs
Roof Construction: Gabled roofs with asphalt shingles
Exterior Finishes: Brick Veneer
Heating, Ventilation and Air Conditioning: None
Fire and Life/Safety: Extinguisher
Dates of Visit: May 24, 2017
On-Site Point of Contact (POC): Eric Dhuse
Assessment and Report Prepared by: Tammy Prusa
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer
For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC --
Structure Good Plumbing Fair
Roof Fair Electrical Fair
Vertical Envelope Good Elevators --
Interiors Fair Fire Good
The following bullet points highlight the most significant short term and modernization recommendations:
There were no short term or modernization recommendations.
BOOSTER PRV STATION EMG PROJECT NO.: 122700.17R000-021.366
2
www.EMGcorp.com p 800.733.0660
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in fair overall condition.
The property has had no major capital improvements. The property is less than 12 years old and has not required any major capital
improvements.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.0% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 84.2% Poor
Current Replacement Value (CRV) 380 SF * $600.00 / SF = $228,000.00
Year 0 (Current Year) - Immediate Repairs (IR) $0.00
BOOSTER PRV STATION EMG PROJECT NO.: 122700.17R000-021.366
3
www.EMGcorp.com p 800.733.0660
Key Finding Metric
Years 1-10 – Replacement Reserves (RR) $192,050.00
Total Capital Needs $192,050.00
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
There were no immediate repair costs observed.
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
BOOSTER PRV STATION EMG PROJECT NO.: 122700.17R000-021.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: ADA Checklist
BOOSTER PRV STATION EMG PROJECT NO.: 122700.17R000-021.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
BOOSTER PRV STATION EMG PROJECT NO: 122700.17R000-021.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: LEFT ELEVATION
#3: REAR ELEVATION
#4: RIGHT ELEVATION
#5: PARKING LOTS, ASPHALT
PAVEMENT
#6: ROOF, ASPHALT SHINGLE
BOOSTER PRV STATION EMG PROJECT NO: 122700.17R000-021.366
www.EMGcorp.com p 800.733.0660
#7: EXTERIOR WALL, BRICK VENEER
#8: EXTERIOR DOOR, STEEL
#9: HEAT PUMP
#10: BOOSTER PUMP
#11: BUILDING AUTOMATION SYSTEM
(HVAC CONTROLS)
#12: TRANSFER SWITCH, AUTOMATIC
(ATS)
BOOSTER PRV STATION EMG PROJECT NO: 122700.17R000-021.366
www.EMGcorp.com p 800.733.0660
#13: GENERATOR, DIESEL
#14: VARIABLE FREQUENCY DRIVE
(VFD)
#15: LIGHTING SYSTEM, INTERIOR
#16: HIGH PRESSURE SODIUM
LIGHTING FIXTURE
#17: SECONDARY TRANSFORMER,
DRY
#18: FIRE EXTINGUISHER
BOOSTER PRV STATION EMG PROJECT NO: 122700.17R000-021.366
www.EMGcorp.com p 800.733.0660
#19: INTERIOR FLOOR FINISH,
CONCRETE
#20: INTERIOR WALL FINISH,
GYPSUM BOARD
#21: INTERIOR CEILING FINISH,
GYPSUM BOARD
BOOSTER PRV STATION EMG PROJECT NO.: 122700.17R000-021.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Booster PRV Station
Project Number:
122700.17R000-021.366
Source:
Google Earth
On-Site Date:
May 24, 2017
BOOSTER PRV STATION EMG PROJECT NO.: 122700.17R000-021.366
www.EMGcorp.com p 800.733.0660
Appendix C:
ADA Checklist
Page 1 of 4
Date Completed: June 7, 2017
Property Name: Booster PRV Station
EMG Project Number: 122700.17R000-021.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
3
Does the width between railings appear at
least 36 inches? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms (cont.) Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Non- Central Booster Pump
101 East Beaver Street
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-022.366 June 28, 2017 May 24, 2017
FACILITY CONDITION ASSESSMENT
NON-CENTRAL BOOSTER PUMP EMG PROJECT NO.: 122700.17R000-022.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
NON-CENTRAL BOOSTER PUMP EMG PROJECT NO.: 122700.17R000-022.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 101 East Beaver Street, Yorkville, IL 60560
Year Constructed/Renovated: 1986
Current Occupants: City of Yorkville
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Booster Pump
Site Area: 0.2 acres
Building Area: 100 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: Driveway
Building Construction: Concrete bearing walls and concrete ceiling
Roof Construction: No roof, underground building consisted of concrete
Exterior Finishes: No exterior finishes, building was underground
Heating, Ventilation and Air Conditioning: Wall mounted electric unit heater
Fire and Life/Safety: N/A
Dates of Visit: May 24, 2017
On-Site Point of Contact (POC): Eric Dhuse
Assessment and Report Prepared by: Tammy Prusa
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer
For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC Fair
Structure Good Plumbing Fair
Roof -- Electrical Fair
Vertical Envelope -- Elevators --
Interiors Fair Fire --
NON-CENTRAL BOOSTER PUMP EMG PROJECT NO.: 122700.17R000-022.366
2
www.EMGcorp.com p 800.733.0660
The following bullet points highlight the most significant short term and modernization recommendations:
Parking lot, seal and stripe
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in fair overall condition.
According to property management personnel, the property has had a limited capital improvement expenditure program over the past
three years, primarily consisting of painting and asphalt pavement seal coating. Supporting documentation was not provided in support
of these claims but some of the work is evident.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
NON-CENTRAL BOOSTER PUMP EMG PROJECT NO.: 122700.17R000-022.366
3
www.EMGcorp.com p 800.733.0660
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.0% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 81.8% Poor
Current Replacement Value (CRV) 100 SF * $1000 / SF = $100,000.00
Year 0 (Current Year) - Immediate Repairs (IR) $0.00
Years 1-10 – Replacement Reserves (RR) $81,774.00
Total Capital Needs $81,774.00
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
There were no immediate repair costs
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
NON-CENTRAL BOOSTER PUMP EMG PROJECT NO.: 122700.17R000-022.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: ADA Checklist
NON-CENTRAL BOOSTER PUMP EMG PROJECT NO.: 122700.17R000-022.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
Non-Central Booster Pump EMG PROJECT NO: 122700.17R000-022.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: RIGHT ELEVATION
#3: INTERIOR LEFT ELEVATION
#4: INTERIOR REAR ELEVATION
#5: INTERIOR FRONT ELEVATION
#6: PARKING LOT, ASPHALT
PAVEMENT
Non-Central Booster Pump EMG PROJECT NO: 122700.17R000-022.366
www.EMGcorp.com p 800.733.0660
#7: PARKING LOT, ASPHALT
PAVEMENT
#8: UNIT HEATER, ELECTRIC
#9: BUILDING AUTOMATION SYSTEM
(HVAC CONTROLS)
#10: EXHAUST FAN, CENTRIFUGAL
#11: BOOSTER PUMP
#12: SUMP PUMP CONTROLLER
Non-Central Booster Pump EMG PROJECT NO: 122700.17R000-022.366
www.EMGcorp.com p 800.733.0660
#13: LIGHTING SYSTEM, INTERIOR
#14: SECONDARY TRANSFORMER,
DRY
#15: DISTRIBUTION PANEL
#16: INTERIOR FLOOR FINISH,
CONCRETE
#17: INTERIOR CEILING FINISH,
CONCRETE
#18: INTERIOR WALL FINISH,
CONCRETE/MASONRY
NON-CENTRAL BOOSTER PUMP EMG PROJECT NO.: 122700.17R000-022.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Non-Central Booster Pump
Project Number:
122700.17R000-022.366
Source:
Google Earth
On-Site Date:
May 24, 2017
NON-CENTRAL BOOSTER PUMP EMG PROJECT NO.: 122700.17R000-022.366
www.EMGcorp.com p 800.733.0660
Appendix C:
ADA Checklist
Page 1 of 4
Date Completed: June 7, 2017
Property Name: Non- Central Booster Pump
EMG Project Number: 122700.17R000-022.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Public Works Office and Garage
610 Tower Lane
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-030.322 September 13, 2017 May 22, 2017
September 11, 2017
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
FACILITY CONDITION ASSESSMENT
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1. Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
1.3. Special Issues and Follow-Up Recommendations ...................................................................... 3
1.4. Opinions of Probable Cost .......................................................................................................... 3
1.4.1. Methodology ................................................................................................................................ 4
1.4.2. Immediate Repairs ...................................................................................................................... 4
1.4.3. Replacement Reserves ............................................................................................................... 4
2. Purpose and Scope .............................................................................................................................. 5
2.1. Purpose ....................................................................................................................................... 5
2.2. Scope .......................................................................................................................................... 6
2.3. Personnel Interviewed ................................................................................................................. 6
2.4. Documentation Reviewed ........................................................................................................... 7
2.5. Pre-Survey Questionnaire ........................................................................................................... 7
2.6. Weather Conditions ..................................................................................................................... 7
3. Accessibility and Property Research ................................................................................................. 8
3.1. ADA Accessibility ........................................................................................................................ 8
3.2. Municipal Information, Flood Zone and Seismic Zone ................................................................ 8
4. Existing Building Assessment ............................................................................................................ 9
4.1. Unit or Space Types .................................................................................................................... 9
4.2. Inaccessible Areas or Key Spaces Not Observed ...................................................................... 9
5. Site Improvements ............................................................................................................................. 10
5.1. Utilities ....................................................................................................................................... 10
5.2. Parking, Paving, and Sidewalks ................................................................................................ 10
5.3. Drainage Systems and Erosion Control .................................................................................... 11
5.4. Topography and Landscaping ................................................................................................... 12
5.5. General Site Improvements ....................................................................................................... 12
6. Building Architectural and Structural Systems ............................................................................... 14
6.1. Foundations ............................................................................................................................... 14
6.2. Superstructure ........................................................................................................................... 14
6.3. Roofing ...................................................................................................................................... 14
6.4. Exterior Walls ............................................................................................................................ 15
6.5. Exterior and Interior Stairs ......................................................................................................... 16
6.6. Exterior Windows and Doors ..................................................................................................... 16
6.7. Patio, Terrace, and Balcony ...................................................................................................... 16
7. Building Mechanical and Plumbing Systems .................................................................................. 17
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC) ..................................................... 17
7.2. Building Plumbing and Domestic Hot Water ............................................................................. 18
7.3. Building Gas Distribution ........................................................................................................... 19
7.4. Building Electrical ...................................................................................................................... 19
7.5. Building Elevators and Conveying Systems .............................................................................. 20
7.6. Fire Protection and Security Systems ....................................................................................... 20
7.7. Life Support Systems ................................................................................................................ 21
8. Interior Spaces .................................................................................................................................... 22
8.1. Interior Finishes ......................................................................................................................... 22
8.2. Commercial Kitchen & Laundry Equipment .............................................................................. 23
9. Other Structures ................................................................................................................................. 24
10. Certification ......................................................................................................................................... 25
11. Appendices ......................................................................................................................................... 26
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
1
www.EMGcorp.com p 800.733.0660
1. Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 610 Tower Lane, Yorkville, IL 60560
Year Constructed/Renovated: 1976 – Office
1996 - Garage
Current Occupants: City of Yorkville
Percent Utilization: 100%.
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Office, Garage
Site Area: 2.0 acres
Building Area: 8,820 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: 9 spaces in open lots
Building Construction: Steel frame with concrete-topped metal decks
Roof Construction: Sloped roofing with metal finish
Exterior Finishes: Metal Siding
Heating, Ventilation & Air Conditioning: Individual package split-system units.
Supplemental components: suspended gas unit heaters and window air conditioning unit.
Fire and Life/Safety: Smoke detectors, strobes, extinguishers, and exit signs.
Dates of Visit: May 22, 2017
On-Site Point of Contact (POC): Eric Dhuse
Assessment and Report Prepared by: Tammy Prusa
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC Fair
Structure Good Plumbing Fair
Roof Fair Electrical Fair
Vertical Envelope Fair Elevators --
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
2
www.EMGcorp.com p 800.733.0660
Systemic Condition Summary
Interiors Fair Fire --
The following bullet points highlight the most significant short term and modernization recommendations:
Repair damage to right elevation exterior wall
Installation of a complete fire alarm system
Mill and overlay asphalt parking lot
Installation of a complete fire suppression system
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in fair overall condition.
The property has had no major capital improvements. The property is less than 32 years old and has not required any major capital
improvements.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
3
www.EMGcorp.com p 800.733.0660
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 6.0% Fair
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 78.4% Poor
Current Replacement Value (CRV) 8,820 SF * $183.24 / SF = $1,616,176.80
Year 0 (Current Year) - Immediate Repairs (IR) $97,079.00
Years 1-10 – Replacement Reserves (RR) $1,267,069.00
Total Capital Needs $1,364,148.00
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Repair damage to right elevation exterior wall
Installation of a complete fire alarm system
Installation of a complete fire suppression system
Add signage and marking for ADA Van accessible parking stall
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
1.3. Special Issues and Follow-Up Recommendations
As part of the FCA, a limited assessment of accessible areas of the building(s) was performed to determine the presence of fungal
growth, conditions conducive to fungal growth, and/or evidence of moisture. Property personnel were interviewed concerning any
known or suspected fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Sampling is not a part of this
assessment.
There are no visual indications of the presence of fungal growth, conditions conducive to fungal growth, or evidence of moisture in
representative readily accessible areas of the property.
1.4. Opinions of Probable Cost
Cost estimates are attached at the front of this report (following the cover page).
These estimates are based on Invoice or Bid Document/s provided either by the Owner/facility and construction costs developed by
construction resources such as R.S. Means and Marshall & Swift, EMG’s experience with past costs for similar properties, city cost
indexes, and assumptions regarding future economic conditions.
Opinions of probable costs should only be construed as preliminary, order of magnitude budgets. Actual costs most probably will vary
from the consultant’s opinions of probable costs depending on such matters as type and design of suggested remedy, quality of
materials and installation, manufacturer and type of equipment or system selected, field conditions, whether a physical deficiency is
repaired or replaced in whole, phasing of the work (if applicable), quality of contractor, quality of project management exercised, market
conditions, and whether competitive pricing is solicited, etc. ASTM E2018-08 recognizes that certain opinions of probable costs cannot
be developed within the scope of this guide without further study. Opinions of probable cost for further study should be included in the
FCA.
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
4
www.EMGcorp.com p 800.733.0660
1.4.1. Methodology
Based upon site observations, research, and judgment, along with referencing Expected Useful Life (EUL) tables from various industry
sources, EMG opines as to when a system or component will most probably necessitate replacement. Accurate historical replacement
records, if provided, are typically the best source of information. Exposure to the elements, initial quality and installation, extent of use,
the quality and amount of preventive maintenance exercised, etc., are all factors that impact the effective age of a system or
component. As a result, a system or component may have an effective age that is greater or less than its actual chronological age.
The Remaining Useful Life (RUL) of a component or system equals the EUL less its effective age. Projections of Remaining Useful Life
(RUL) are based on continued use of the Property similar to the reported past use. Significant changes in occupants and/or usage may
affect the service life of some systems or components.
Where quantities could not be derived from an actual take-off, lump sum costs or allowances are used. Estimated costs are based on
professional judgment and the probable or actual extent of the observed defect, inclusive of the cost to design, procure, construct and
manage the corrections.
1.4.2. Immediate Repairs
Immediate repairs are opinions of probable costs that require immediate action as a result of: (1) material existing or potential unsafe
conditions, (2) material building or fire code violations, or (3) conditions that, if not addressed, have the potential to result in, or
contribute to, critical element or system failure within one year or will most probably result in a significant escalation of its remedial cost.
1.4.3. Replacement Reserves
Replacement Reserves are for recurring probable expenditures, which are not classified as operation or maintenance expenses. The
replacement reserves should be budgeted for in advance on an annual basis. Replacement Reserves are reasonably predictable both
in terms of frequency and cost. However, Replacement Reserves may also include components or systems that have an
indeterminable life but, nonetheless, have a potential for failure within an estimated time period.
Replacement Reserves exclude systems or components that are estimated to expire after the reserve term and are not considered
material to the structural and mechanical integrity of the subject property. Furthermore, systems and components that are not deemed
to have a material effect on the use of the Property are also excluded. Costs that are caused by acts of God, accidents, or other
occurrences that are typically covered by insurance, rather than reserved for, are also excluded.
Replacement costs are solicited from ownership/property management, EMG’s discussions with service companies, manufacturers'
representatives, and previous experience in preparing such schedules for other similar facilities. Costs for work performed by the
ownership’s or property management’s maintenance staff are also considered.
EMG’s reserve methodology involves identification and quantification of those systems or components requiring capital reserve funds
within the assessment period. The assessment period is defined as the effective age plus the reserve term. Additional information
concerning system’s or component’s respective replacement costs (in today's dollars), typical expected useful lives, and remaining
useful lives were estimated so that a funding schedule could be prepared. The Replacement Reserves Schedule presupposes that all
required remedial work has been performed or that monies for remediation have been budgeted for items defined in the Immediate
Repair Cost Estimate.
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
5
www.EMGcorp.com p 800.733.0660
2. Purpose and Scope
2.1. Purpose
EMG was retained by the client to render an opinion as to the Property’s current general physical condition on the day of the site visit.
Based on the observations, interviews and document review outlined below, this report identifies significant deferred maintenance
issues, existing deficiencies, and material code violations of record at municipal offices, which affect the Property’s use. Opinions are
rendered as to its structural integrity, building system condition and the Property’s overall condition. The report also notes building
systems or components that have realized or exceeded their typical expected useful lives.
CONDITIONS:
The physical condition of building systems and related components are typically defined as being in one of five conditions: Excellent,
Good, Fair, Poor, Failed or a combination thereof. For the purposes of this report, the following definitions are used:
Excellent = New or very close to new; component or system typically has been installed within the past year, sound and
performing its function. Eventual repair or replacement will be required when the component or system either
reaches the end of its useful life or fails in service.
Good = Satisfactory as-is. Component or system is sound and performing its function, typically within the first third of its
lifecycle. However, it may show minor signs of normal wear and tear. Repair or replacement will be required
when the component or system either reaches the end of its useful life or fails in service.
Fair = Showing signs of wear and use but still satisfactory as-is, typically near the median of its estimated useful life.
Component or system is performing adequately at this time but may exhibit some signs of wear, deferred
maintenance, or evidence of previous repairs. Repair or replacement will be required due to the component or
system’s condition and/or its estimated remaining useful life.
Poor = Component or system is significantly aged, flawed, functioning intermittently or unreliably; displays obvious
signs of deferred maintenance; shows evidence of previous repair or workmanship not in compliance with
commonly accepted standards; has become obsolete; or exhibits an inherent deficiency. The present condition
could contribute to or cause the deterioration of contiguous elements or systems. Either full component
replacement is needed or repairs are required to restore to good condition, prevent premature failure, and/or
prolong useful life.
Failed
= Component or system has ceased functioning or performing as intended. Replacement, repair, or other
significant corrective action is recommended or required.
Not Applicable
= Assigning a condition does not apply or make logical sense, most commonly due to the item in question not
being present.
Throughout sections 5 through 9 of this report, each report section will typically contain three subsections organized in the following
sequence:
A descriptive table (and/or narrative), which identifies the components assessed, their condition, and other key data points.
A simple bulleted list of Anticipated Lifecycle Replacements, which lists components and assets typically in Excellent, Good, or Fair
condition at the time of the assessment but that will require replacement or some other attention once aged past their estimated
useful life. These listed components are typically included in the associated inventory database with costs identified and budgeted
beyond the first several years.
A bulleted cluster of Actions/Comments, which include more detailed narratives describing deficiencies, recommended repairs, and
short term replacements. The assets and components associated with these bullets are/were typically problematic and in Poor or
Failed condition at the time of the assessment, with corresponding costs included within the first few years.
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
6
www.EMGcorp.com p 800.733.0660
PLAN TYPES:
Each line item in the cost database is assigned a Plan Type, which is the primary reason or rationale for the recommended
replacement, repair, or other corrective action. This is the “why” part of the equation. A cost or line item may commonly have more
than one applicable Plan Type; however, only one Plan Type will be assigned based on the “best” fit, typically the one with the greatest
significance. The following Plan Types are listed in general weighted order of importance:
Safety = An observed or reported unsafe condition that if left unaddressed could result in an injury; a system
or component that presents a potential liability risk.
Performance/Integrity = Component or system has failed, is almost failing, performs unreliably, does not perform as intended,
and/or poses a risk to overall system stability.
Accessibility = Does not meet ADA, UFAS, and/or other handicap accessibility requirements.
Environmental = Improvements to air or water quality, including removal of hazardous materials from the building or
site.
Modernization/Adaptation
= Conditions, systems, or spaces that need to be upgraded in appearance or function to meet current
standards, facility usage, or client/occupant needs.
Lifecycle/Renewal
= Any component or system in which future repair or replacement is anticipated beyond the next
several years and/or is of minimal substantial early-term consequence.
2.2. Scope
The standard scope of the Facility Condition Assessment includes the following:
Visit the Property to evaluate the general condition of the building and site improvements, review available construction documents in
order to familiarize ourselves with, and be able to comment on, the in-place construction systems, life safety, mechanical, electrical,
and plumbing systems, and the general built environment.
Identify those components that are exhibiting deferred maintenance issues and provide cost estimates for Immediate Costs and
Replacement Reserves based on observed conditions, maintenance history and industry standard useful life estimates. This will
include the review of documented capital improvements completed within the last five-year period and work currently contracted for, if
applicable.
Provide a full description of the Property with descriptions of in-place systems and commentary on observed conditions.
Provide a general statement of the subject Property’s compliance to Title III of the Americans with Disabilities Act. This will not
constitute a full ADA survey, but will help identify exposure to issues and the need for further review.
Perform a limited assessment of accessible areas of the building(s) for the presence of fungal growth, conditions conducive to fungal
growth, and/or evidence of moisture. EMG will also interview Project personnel regarding the presence of any known or suspected
fungal growth, elevated relative humidity, water intrusion, or mildew-like odors. Potentially affected areas will be photographed.
Sampling will not be considered in routine assessments.
List the current utility service providers.
Review maintenance records and procedures with the in-place maintenance personnel.
Observe a representative sample of the interior spaces/units, including vacant spaces/units, in order to gain a clear understanding of
the property’s overall condition. Other areas to be observed include the exterior of the property, the roofs, interior common areas,
and the significant mechanical, electrical and elevator equipment rooms.
Provide an Executive Summary at the beginning of this report.
Prepare a mechanical equipment inventory list.
2.3. Personnel Interviewed
The management was interviewed for specific information relating to the physical property, available maintenance procedures, historical
performance of key building systems and components, available drawings and other documentation. The following personnel from the
facility and government agencies were interviewed in the process of conducting the FCA:
Name and Title Organization Phone Number
Eric Dhuse City of Yorkville 630.878.7102
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
7
www.EMGcorp.com p 800.733.0660
The FCA was performed with the assistance of Eric Dhuse, City of Yorkville, the onsite Point of Contact (POC), who was cooperative
and provided information that appeared to be accurate based upon subsequent site observations. The onsite contact is completely
knowledgeable about the subject property and answered most questions posed during the interview process. The POC’s management
involvement at the property has been for the past 23 years.
2.4. Documentation Reviewed
Prior to the FCA, relevant documentation was requested that could aid in the knowledge of the subject property’s physical
improvements, extent and type of use, and/or assist in identifying material discrepancies between reported information and observed
conditions. The review of submitted documents does not include comment on the accuracy of such documents or their preparation,
methodology, or protocol. The Documentation Request Form is provided in Appendix E.
Although Appendix E provides a summary of the documents requested or obtained, the following list provides more specific details
about some of the documents that were reviewed or obtained during the site visit.
No documents available.
2.5. Pre-Survey Questionnaire
A Pre-Survey Questionnaire was sent to the POC prior to the site visit. The questionnaire is included in Appendix E. Information
obtained from the questionnaire has been used in preparation of this report.
2.6. Weather Conditions
May 22, 2017: Clear, with temperatures in the 70’s (°F) and light winds.
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
8
www.EMGcorp.com p 800.733.0660
3. Accessibility and Property Research
3.1. ADA Accessibility
Generally, Title III of the Americans with Disabilities Act (ADA) prohibits discrimination by entities to access and use of “areas of public
accommodations” and “commercial facilities” on the basis of disability. Regardless of its age, these areas and facilities must be
maintained and operated to comply with the Americans with Disabilities Act Accessibility Guidelines (ADAAG).
Buildings completed and occupied after January 26, 1992 are required to comply fully with the ADAAG. Existing facilities constructed
prior to this date are held to the lesser standard of compliance to the extent allowed by structural feasibility and the financial resources
available. As an alternative, a reasonable accommodation pertaining to the deficiency must be made.
During the FCA, a limited visual observation for ADA accessibility compliance was conducted. The scope of the visual observation was
limited to those areas set forth in EMG’s Abbreviated Accessibility Checklist provided in Appendix D of this report. It is understood by
the Client that the limited observations described herein does not comprise a full ADA Compliance Survey, and that such a survey is
beyond the scope of EMG’s undertaking. Only a representative sample of areas was observed and, other than as shown on the
Abbreviated Accessibility Checklist, actual measurements were not taken to verify compliance.
At an office/garage property, the areas considered as a public accommodation besides the site itself and parking, are the exterior
accessible route, the interior accessible route up to the tenant lease lines and the interior common areas, including the common area
restrooms.
The facility does not appear to be accessible with Title III of the Americans with Disabilities Act. Elements as defined by the ADAAG
that are not accessible as stated within the priorities of Title III, are as follows:
Parking
Signage indicating accessible parking spaces for cars and vans are not provided.
Entrances/Exits
Lever action hardware is not provided at all accessible locations.
Restrooms
Lever action hardware is not provided at all accessible locations.
Modify existing lavatory faucets to paddle type faucets.
A full ADA Compliance Survey may reveal additional aspects of the property that are not in compliance.
Corrections of these conditions should be addressed from a liability standpoint, but are not necessarily code violations. The Americans
with Disabilities Act Accessibility Guidelines concern civil rights issues as they pertain to the disabled and are not a construction code,
although many local jurisdictions have adopted the Guidelines as such. The cost to address the achievable items noted above is
included in the cost tables.
3.2. Municipal Information, Flood Zone and Seismic Zone
Not Applicable
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
9
www.EMGcorp.com p 800.733.0660
4. Existing Building Assessment
4.1. Unit or Space Types
All 8,820 square feet of the building are occupied by a single occupant, City of Yorkville. The spaces are mostly a combination of
offices, garages, and supporting restrooms.
4.2. Inaccessible Areas or Key Spaces Not Observed
The interior spaces were observed in order to gain a clear understanding of the property’s overall condition. Other areas accessed
included the site within the property boundaries, exterior of the property and the roof. Areas of note that were either inaccessible or not
observed for other reasons are listed in the table below:
Key Spaces Not Observed
Room Number Area Access Issues
Above bathroom in garage Lack of ladder
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
10
www.EMGcorp.com p 800.733.0660
5. Site Improvements
5.1. Utilities
The following table identifies the utility suppliers and the condition and adequacy of the services.
Site Utilities
Utility Supplier Condition and Adequacy
Sanitary sewer City of Yorkville Good
Storm sewer City of Yorkville Good
Domestic water City of Yorkville Good
Electric service Commonwealth Edison Good
Natural gas service Nicor Gas Good
Actions/Comments:
According to the POC, the utilities provided are adequate for the property. There are no unique, onsite utility systems such as
emergency electrical generators, septic systems, water or waste water treatment plants, or propane gas tanks.
5.2. Parking, Paving, and Sidewalks
Item Description
Main Ingress and Egress Tower Lane
Access from West
Additional Entrances N/A
Additional Access from N/A
Paving and Flatwork
Item Material Last Work Done Condition
Entrance Driveway Apron Asphalt - Fair
Parking Lot Asphalt - Fair
Drive Aisles None - --
Service Aisles None - --
Sidewalks None - --
Curbs None - --
Site Stairs None - --
Pedestrian Ramps None - --
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
11
www.EMGcorp.com p 800.733.0660
Parking Count
Open Lot Carport Private Garage Subterranean Garage Freestanding Parking
Structure
9 - - - -
Total Number of ADA Compliant Spaces 0
Number of ADA Compliant Spaces for Vans 0
Total Parking Spaces 9
Parking Ratio (Spaces/Apartments) -
Method of Obtaining Parking Count Physical count
Anticipated Lifecycle Replacements:
Asphalt seal coating
Asphalt pavement mill and overlay
Signage and marking for ADA Van accessible parking stall
Actions/Comments:
The asphalt pavement exhibits significant areas of failure and deterioration, such as alligator cracking and localized depressions.
The most severely damaged areas of paving must be cut and patched in order to maintain the integrity of the overall pavement
system. Complete milling and overlay of the entire lot is also recommended.
5.3. Drainage Systems and Erosion Control
Drainage System and Erosion Control
System Exists At Site Condition
Surface Flow ☒ Good
Inlets ☐ --
Swales ☐ --
Detention pond ☐ --
Lagoons ☐ --
Ponds ☐ --
Underground Piping ☐ --
Pits ☐ --
Municipal System ☐ --
Dry Well ☐ --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
There is no evidence of storm water runoff from adjacent properties. The storm water system appears to provide adequate runoff
capacity. There is no evidence of major ponding or erosion.
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
12
www.EMGcorp.com p 800.733.0660
5.4. Topography and Landscaping
Item Description
Site Topography Generally flat.
Landscaping
Trees Grass Flower Beds Planters
Drought
Tolerant
Plants
Decorative Stone None
☐ ☐ ☐ ☐ ☐ ☐ ☒
Landscaping Condition --
Irrigation Automatic Underground Drip Hand Watering None
☐ ☐ ☐ ☒
Irrigation Condition --
Retaining Walls
Type Location Condition
None -- --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The topography and adjacent uses do not appear to present conditions detrimental to the property. There are no significant areas of
erosion.
5.5. General Site Improvements
Property Signage
Property Signage Post mounted wood
Street Address Displayed? Yes
Site and Building Lighting
Site Lighting
None Pole Mounted Bollard Lights Ground Mounted Parking Lot Pole
Type
☒ ☐ ☐ ☐ ☐
--
Building Lighting
None Wall Mounted Recessed Soffit
☐ ☒ ☐
Fair
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
13
www.EMGcorp.com p 800.733.0660
Site Fencing
Type Location Condition
Chain link with metal posts Perimeter Fair
Refuse Disposal
Refuse Disposal Means of disposal not apparent
Dumpster Locations Mounting Enclosure Contracted? Condition
None None None No --
Other Site Amenities
Description Location Condition
Playground Equipment None -- --
Tennis Courts None -- --
Basketball Court None -- --
Swimming Pool None -- --
Anticipated Lifecycle Replacements:
Signage
Exterior lighting
Site fencing
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended. Future lifecycle
replacements of the components listed above will be required.
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
14
www.EMGcorp.com p 800.733.0660
6. Building Architectural and Structural Systems
6.1. Foundations
Building Foundation
Item Description Condition
Foundation Slab on grade with integral footings Good
Basement and Crawl Space None --
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
There are no significant signs of settlement, deflection, or movement.
6.2. Superstructure
Building Superstructure
Item Description Condition
Framing / Load-Bearing Walls Steel columns and beams Good
Ground Floor Concrete slab Good
Upper Floor Framing Wood joists Good
Upper Floor Decking Plywood or OSB Fair
Roof Framing Steel beams or girders Good
Roof Decking Metal decking Fair
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The superstructure is exposed in some locations, which allows for limited observation. Walls and floors appear to be plumb, level,
and stable. There are no significant signs of deflection or movement.
6.3. Roofing
Primary Roof
Type / Geometry Gable Roof Finish Metal
Maintenance Outside Contractor Roof Age 21 Yrs
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
15
www.EMGcorp.com p 800.733.0660
Primary Roof
Flashing Sheet metal Warranties None
Parapet Copings None Roof Drains Gutters and downspouts
Fascia Metal Panel Insulation Fiberglass batts
Soffits None Skylights No
Attics Steel beams Ponding No
Ventilation Source-1 Ridge Vents Leaks Observed No
Ventilation Source-2 -- Roof Condition Fair
Anticipated Lifecycle Replacements:
Metal roof
Actions/Comments:
The roof finishes are original. Information regarding roof warranties or bonds was not available. The roofs are maintained by an
outside contractor.
There is no evidence of active roof leaks.
There is no evidence of roof deck or insulation deterioration. The roof substrate and insulation should be inspected during any future
roof repair or replacement work.
Roof drainage appears to be adequate. Clearing and minor repair of drain system components should be performed regularly as part
of the property management’s routine maintenance and operations program.
The attics are not accessible and it could not be determined if there is moisture, water intrusion, or excessive daylight in the attics.
6.4. Exterior Walls
Building Exterior Walls
Type Location Condition
Primary Finish Metal siding Fair
Secondary Finish -- --
Accented with -- --
Soffits Not Applicable --
Building sealants (caulking) are located between dissimilar materials, at joints, and around window and door openings.
Anticipated Lifecycle Replacements:
Metal siding
Actions/Comments:
The metal siding has isolated areas of damaged siding along the north and south elevation of the building. The damaged siding must
be repaired.
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
16
www.EMGcorp.com p 800.733.0660
6.5. Exterior and Interior Stairs
Building Exterior and Interior Stairs
Type Description Riser Handrail Balusters Condition
Building Exterior Stairs None -- -- -- --
Building Interior Stairs Wood-framed Closed Wood Wood Fair
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
No significant actions are identified at the present time. On-going periodic maintenance is highly recommended.
6.6. Exterior Windows and Doors
Building Windows
Window Framing Glazing Location Window
Screen Condition
Aluminum framed, operable Double glaze Exterior Walls ☒ Fair
Building Doors
Main Entrance Doors Door Type Condition
Metal, hollow Fair
Secondary Entrance Doors Solid core wood Fair
Service Doors Metal, hollow Fair
Overhead Doors Aluminium Fair
Anticipated Lifecycle Replacements:
Windows
Exterior metal doors
Actions/Comments:
Damage to double-glazed window on west elevation of building. Outer pane of glass needs to be replaced.
6.7. Patio, Terrace, and Balcony
Not applicable. There are no patios, terraces, or balconies.
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
17
www.EMGcorp.com p 800.733.0660
7. Building Mechanical and Plumbing Systems
See the Mechanical Equipment List in the Appendices for the quantity, manufacturer’s name, model number, capacity and year of
manufacturer of the major mechanical equipment, if available.
7.1. Building Heating, Ventilating, and Air Conditioning (HVAC)
Individual Units
Primary Components Split system furnaces and condensing units
Cooling (if separate from above) performed via components above
Quantity and Capacity Ranges 2 units ranging from 2 tons/BTUH to 5 tons/BTUH
Total Heating or Cooling Capacity 7 tons/BTUH
Heating Fuel Natural gas
Location of Equipment Building exterior
Space Served by System Entire building
Age Ranges All units dated 2000
Primary Component Condition Fair
Supplemental Components
Supplemental Component #1 Suspended unit heaters
Location / Space Served by Suspended Unit Heaters Garage
Suspended Unit Heater Condition Fair
Supplemental Component #2 Window Air Conditioning Unit
Location / Space Served by Window Air Conditioning Unit Small Upper Office Area
Window Air Conditioning Unit Condition Fair
Controls and Ventilation
HVAC Control System Individual programmable thermostats/controls
HVAC Control System Condition Fair
Building Ventilation Roof top exhaust fans
Ventilation System Condition Fair
Anticipated Lifecycle Replacements:
Split system furnaces and condensing units
Suspended gas unit heaters
Through-wall air conditioners
Rooftop exhaust fans
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
18
www.EMGcorp.com p 800.733.0660
Actions/Comments:
The HVAC systems are maintained by the in-house maintenance staff. Records of the installation, maintenance, upgrades, and
replacement of the HVAC equipment at the property have been maintained since the property was first occupied.
The HVAC equipment appears to have been installed in 2000. HVAC equipment is replaced on an "as needed" basis.
The HVAC equipment appears to be functioning adequately overall. No chronic problems were reported and an overall sense of
satisfaction with the systems was conveyed. However, due to the inevitable failure of parts and components over time, some of the
equipment will require replacement.
7.2. Building Plumbing and Domestic Hot Water
Building Plumbing System
Type Description Condition
Water Supply Piping Copper Fair
Waste/Sewer Piping Cast iron Fair
Vent Piping Cast iron Fair
Water Meter Location Bathroom closet in office
Domestic Water Heaters or Boilers
Components Water Heaters
Fuel Natural gas
Quantity and Input Capacity 2 units at approximately 40,000 BTUH each
Storage Capacity 40 gallons
Water Heater Condition Fair
Supplementary Storage Tanks? No
Storage Tank Quantity & Volume --
Quantity of Storage Tanks --
Storage Tank Condition --
Domestic Hot Water Circulation Pumps (3 HP and over) --
Adequacy of Hot Water Adequate
Adequacy of Water Pressure Adequate
Plumbing Fixtures
Water Closets Residential grade
Toilet (Water Closet) Flush Rating 1.6 GPF
Common Area Faucet Nominal Flow Rate 2.0 GPM
Condition Fair
Anticipated Lifecycle Replacements:
Water heaters
Toilets
Sinks
Vanities
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
19
www.EMGcorp.com p 800.733.0660
Actions/Comments:
The plumbing systems appear to be well maintained and functioning adequately. The water pressure appears to be sufficient. No
significant repair actions or short-term replacement costs are required. Routine and periodic maintenance is recommended. Future
lifecycle replacements of the components or systems listed above will be required.
7.3. Building Gas Distribution
Gas service is supplied from the gas main on the adjacent public street. The gas meters and regulators are located along the exterior
walls of the buildings. The gas distribution piping within the building is malleable steel (black iron).
Anticipated Lifecycle Replacements:
No components of significance
Actions/Comments:
The pressure and quantity of gas appear to be adequate.
The gas meters and regulators appear to be functioning adequately and will require routine maintenance.
Only limited observation of the gas distribution piping can be made due to hidden conditions.
7.4. Building Electrical
Building Electrical Systems
Electrical Lines Underground Transformer Pad-mounted
Main Service Size 400 Amps Volts 120/240 Volt, single-phase
Meter & Panel Location North elevation of building Branch Wiring Copper
Conduit Metallic Step-Down Transformers? No
Security / Surveillance System? No Building Intercom System? No
Lighting Fixtures T-12
Main Distribution Condition Fair
Secondary Panel and Transformer
Condition Fair
Lighting Condition Fair
Anticipated Lifecycle Replacements:
Circuit breaker panels
Interior light fixtures
Actions/Comments:
The onsite electrical systems up to the meters are owned and maintained by the respective utility company.
The electrical service and capacity appear to be adequate for the property’s demands.
The panels are mostly original 1976 and 1996 components. The electrical service is reportedly adequate for the facility’s needs.
However, due to the age of the panels and increasing difficulty of obtaining replacement parts over time, lifecycle replacements are
recommended per above.
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
20
www.EMGcorp.com p 800.733.0660
The light fixtures throughout most of the facility utilize older, inefficient T-12 lamps. Replacement with newer fixtures with electronic
ballasts and T-8 lamps is highly recommended to save substantial amounts of energy.
7.5. Building Elevators and Conveying Systems
Not applicable. There are no elevators or conveying systems.
7.6. Fire Protection and Security Systems
Item Description
Type None
Fire Alarm System
Central Alarm Panel ☐ Battery-Operated Smoke
Detectors ☒ Alarm Horns ☐
Annunciator Panels ☐ Hard-Wired Smoke
Detectors ☐ Strobe Light Alarms ☐
Pull Stations ☐ Emergency Battery-Pack
Lighting ☒ Illuminated EXIT Signs ☒
Alarm System
Condition Fair
Sprinkler System
None ☒ Standpipes ☐ Backflow Preventer ☐
Hose Cabinets ☐ Fire Pumps ☐ Siamese Connections ☐
Suppression Condition --
Central Alarm Panel
System
Location of Alarm Panel Installation Date of Alarm Panel
None None
Fire Extinguishers
Last Service Date Servicing Current?
2016 Yes
Hydrant Location North elevation of building by door
Siamese Location --
Special Systems Kitchen Suppression System ☐Computer Room Suppression System ☐
Anticipated Lifecycle Replacements:
Installation of a complete fire alarm system
Installation of a complete fire suppression system
Exit signs
Fire extinguishers
Actions/Comments:
The vast majority of the building is not protected by fire suppression and alarm system. Due to its construction date, the facility is
most likely “grandfathered” by code and the installation of fire sprinklers and alarm system was not required until major renovations
are performed. Regardless of when or if installation of facility-wide fire suppression and alarm system is required by the governing
municipality, EMG recommends a retrofit be performed. A budgetary cost is included.
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
21
www.EMGcorp.com p 800.733.0660
7.7. Life Support Systems
Not Applicable
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
22
www.EMGcorp.com p 800.733.0660
8. Interior Spaces
8.1. Interior Finishes
The facility is used as an office building and garage for the City of Yorkville. The most significant interior spaces include offices and
garages. Supporting areas include hallways, stairs, administrative offices, restrooms, employee break rooms, and utility closets.
The following table generally describes the locations and typical conditions of the interior finishes within the facility:
Typical Floor Finishes
Floor Finish Locations General Condition
Ceramic tile Restrooms Fair
Vinyl tile Office, restrooms, break area Fair
Hardwood Office Fair
Concrete Garage Fair
Typical Wall Finishes
Wall Finish Locations General Condition
Painted drywall Offices, restrooms, break area Fair
Metal Garages Fair
Ceramic tile Restrooms Fair
Typical Ceiling Finishes
Ceiling Finish Locations General Condition
Painted drywall Offices, restrooms, break area Fair
Exposed structure Garages Good
Metal Garages Fair
Interior Doors
Item Type Condition
Interior Doors Steel w/ Glass, Wood Hollow-Core Fair
Door Framing Wood Fair
Fire Doors No --
Anticipated Lifecycle Replacements:
Vinyl tile
Ceramic tile
Metal wall panel
Metal ceiling panel
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
23
www.EMGcorp.com p 800.733.0660
Wood floor
Interior paint
Interior doors
Kitchenette appliances
Laundry room washers
Laundry room dryers
Actions/Comments:
It appears that the interior finishes are original.
The ceilings have isolated areas of water-damaged ceilings in the break area. The damaged ceiling areas need to be repaired. The
cost to replace the damaged finishes is relatively insignificant and the work can be performed as part of the property management’s
routine maintenance program.
8.2. Commercial Kitchen & Laundry Equipment
Not applicable.
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
24
www.EMGcorp.com p 800.733.0660
9. Other Structures
Not applicable. There are no major accessory structures.
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
25
www.EMGcorp.com p 800.733.0660
10. Certification
City of Yorkville retained EMG to perform this Facility Condition Assessment in connection with its continued operation of Public Works
Office and Garage, 610 Tower Lane Yorkville, Illinois, the “Property”. It is our understanding that the primary interest of City of Yorkville
is to locate and evaluate materials and building system defects that might significantly affect the value of the property and to determine
if the present Property has conditions that will have a significant impact on its continued operations.
The conclusions and recommendations presented in this report are based on the brief review of the plans and records made available
to our Project Manager during the site visit, interviews of available property management personnel and maintenance contractors
familiar with the Property, appropriate inquiry of municipal authorities, our Project Manager’s walk-through observations during the site
visit, and our experience with similar properties.
No testing, exploratory probing, dismantling or operating of equipment or in-depth studies were performed unless specifically required
under Section 2 of this report. This assessment did not include engineering calculations to determine the adequacy of the Property’s
original design or existing systems. Although walk-through observations were performed, not all areas were observed (See Section 4.2
for areas observed). There may be defects in the Property, which were in areas not observed or readily accessible, may not have been
visible, or were not disclosed by management personnel when questioned. The report describes property conditions at the time that
the observations and research were conducted.
This report has been prepared on behalf of and exclusively for the use of City of Yorkville for the purpose stated within Section 2 of this
report. The report, or any excerpt thereof, shall not be used by any party other than City of Yorkville or for any other purpose than that
specifically stated in our agreement or within Section 2 of this report without the express written consent of EMG.
This report, or any of the information contained therein, is not for the use or benefit of, nor may it be relied upon by any other person or
entity, for any purpose without the advance written consent of EMG. Any reuse or distribution without such consent shall be at the
client’s or recipient’s sole risk, without liability to EMG.
Prepared by: Tammy Prusa,
Project Manager
Reviewed by:
Paul Prusa P.E., LEED AP,
Technical Report Reviewer For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
26
www.EMGcorp.com p 800.733.0660
11. Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: EMG Accessibility Checklist
Appendix D: Pre-Survey Questionnaire
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
PUBLIC WORKS OFFICE AND GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: FRONT ELEVATION-OFFICE
#3: FRONT ELEVATION-GARAGE
#4: LEFT ELEVATION-GARAGE
#5: LEFT ELEVATION-OFFICE
#6: REAR ELEVATION
PUBLIC WORKS OFFICE AND GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
#7: RIGHT ELEVATION-OFFICE
#8: RIGHT ELEVATION-GARAGE
#9: PARKING LOTS, ASPHALT
PAVEMENT
#10: PARKING LOTS, CRACKING IN
ASPHALT
#11: STRUCTURAL FRAME, STEEL
COLUMNS & BEAMS
#12: FOUNDATIONS, CONCRETE
SLAB-ON-GRADE
PUBLIC WORKS OFFICE AND GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
#13: FOUNDATIONS, CONCRETE
SLAB-ON-GRADE
#14: ROOF, METAL
#15: ROOF, METAL
#16: EXTERIOR WALL, STEEL
#17: EXTERIOR WALL, ALUMINUM
SIDING
#18:
PUNCTURE AND CRACKING TO
ALUMINUM SIDING ON SOUTH
ELEVATION OF BUILDING
PUBLIC WORKS OFFICE AND GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
#19:
PUNCTURE TO ALUMINUM
SIDING ON NORTH ELEVATION
OF BUILDING
#20: INTERIOR STAIRS, WOOD
#21: WINDOW, ALUMINUM DOUBLE-
GLAZED
#22: WINDOW, BROKEN PANE OF
GLASS
#23: OVERHEAD DOOR, ALUMINUM
ROLL-UP
#24: EXTERIOR DOOR, STEEL
PUBLIC WORKS OFFICE AND GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
#25: EXTERIOR DOOR, WOOD SOLID-
CORE W/ GLASS
#26: RESIDENTIAL FIXTURES,
CEILING FAN
#27: CONDENSING UNIT, SPLIT
SYSTEM
#28: AIR CONDITIONER,
WINDOW/THRU-WALL
#29: UNIT HEATER, NATURAL GAS
#30: EXHAUST FAN, PROPELLER
PUBLIC WORKS OFFICE AND GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
#31: TOILET, FLUSH TANK (WATER
CLOSET)
#32:
BATHROOM VANITY CABINET,
WOOD, WITH CULTURED
MARBLE SINK TOP
#33: WATER HEATER, GAS
#34: SINK, PLASTIC
#35: DRINKING FOUNTAIN,
REFRIGERATED
#36: OVERHEAD DOOR, AUTOMATIC
OPENER
PUBLIC WORKS OFFICE AND GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
#37: MAIN DISTRIBUTION PANEL
#38: HIGH PRESSURE SODIUM
LIGHTING FIXTURE
#39: LIGHTING SYSTEM, INTERIOR
#40: HALOGEN LIGHTING FIXTURE
#41: FIRE EXTINGUISHER
#42: EXIT LIGHTING FIXTURE
PUBLIC WORKS OFFICE AND GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
#43: INTERIOR CEILING FINISH,
GYPSUM BOARD
#44: INTERIOR DOOR, STEEL W/
GLASS
#45: INTERIOR WALL FINISH,
CERAMIC TILE
#46: INTERIOR FLOOR FINISH, VINYL
TILE (VCT)
#47: INTERIOR FLOOR FINISH, WOOD
STRIP
#48: INTERIOR FLOOR FINISH,
CERAMIC TILE
PUBLIC WORKS OFFICE AND GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
#49: RESIDENTIAL APPLIANCES,
CLOTHES DRYER
#50: INTERIOR CEILING FINISH,
METAL
#51: INTERIOR DOOR, HOLLOW CORE
WOOD
#52: INTERIOR WALL FINISH,
ALUMINUM
#53: INTERIOR WINDOW
#54: INTERIOR WALL FINISH,
CERAMIC TILE
PUBLIC WORKS OFFICE AND GARAGE
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
#55: RESIDENTIAL APPLIANCES,
CLOTHES WASHER
#56: SINK, STAINLESS STEEL
#57: RESIDENTIAL APPLIANCES,
REFRIGERATOR
#58: KITCHEN CABINET, BASE AND
WALL SECTION, WOOD
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Public Works Office and Garage
Project Number:
122700.17R000-030.322
Source:
Google Earth
On-Site Date:
May 22, 2017
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
Appendix C:
EMG Accessibility Checklist
Page 1 of 4
Date Completed: June 6, 2017
Property Name: Public Works Office and Garage
EMG Project Number: 122700.17R000-030.322
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
Appendix D:
Pre-Survey Questionnaire
PUBLIC WORKS OFFICE AND GARAGE EMG PROJECT NO.: 122700.17R000-030.322
www.EMGcorp.com p 800.733.0660
On the day of the site visit, provide EMG's Field Observer access to all of the available documents listed below.
Provide copies if possible.
INFORMATION REQUIRED
1. All available construction documents (blueprints) for
the original construction of the building or for any tenant
improvement work or other recent construction work.
2. A site plan, preferably 8 1/2" X 11", which depicts the
arrangement of buildings, roads, parking stalls, and other
site features.
3. For commercial properties, provide a tenant list which
identifies the names of each tenant, vacant tenant units,
the floor area of each tenant space, and the gross and
net leasable area of the building(s).
4. For apartment properties, provide a summary of the
apartment unit types and apartment unit type quantities,
including the floor area of each apartment unit as
measured in square feet.
5. For hotel or nursing home properties, provide a
summary of the room types and room type quantities.
6. Copies of Certificates of Occupancy, building permits,
fire or health department inspection reports, elevator
inspection certificates, roof or HVAC warranties, or any
other similar, relevant documents.
7. The names of the local utility companies which serve
the property, including the water, sewer, electric, gas,
and phone companies.
8. The company name, phone number, and contact
person of all outside vendors who serve the property,
such as mechanical contractors, roof contractors, fire
sprinkler or fire extinguisher testing contractors, and
elevator contractors.
9. A summary of recent (over the last 5 years) capital
improvement work which describes the scope of the
work and the estimated cost of the improvements.
Executed contracts or proposals for improvements.
Historical costs for repairs, improvements, and
replacements.
10. Records of system & material ages (roof, MEP,
paving, finishes, furnishings).
11. Any brochures or marketing information.
12. Appraisal, either current or previously prepared.
13. Current occupancy percentage and typical turnover
rate records (for commercial and apartment properties).
14. Previous reports pertaining to the physical condition
of property.
15. ADA survey and status of improvements
implemented.
16. Current / pending litigation related to property
condition.
Your timely compliance with this request is greatly appreciated.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Salt Storage Building
610 Tower Lane
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-033.366 6HSWHPEHU May 22, 2017
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
FACILITY CONDITION ASSESSMENT
SALT STORAGE BUILDING EMG PROJECT NO.: 122700.17R000-033.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
SALT STORAGE BUILDING EMG PROJECT NO.: 122700.17R000-033.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 610 Tower Lane, Yorkville, IL 60560
Year Constructed/Renovated: 1996
Current Occupants: City Of Yorkville
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Storage
Site Area: 0.1 acres
Building Area: 1,600 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: Parking lot has been included in the Public Works Office & Garage Report.
Building Construction: Conventional wood frame structure on concrete slab.
Roof Construction: Gabled roofs with metal siding
Exterior Finishes: Metal Siding
Heating, Ventilation and Air Conditioning: N/A
Fire and Life/Safety: N/A
Dates of Visit: May 22, 2017
On-Site Point of Contact (POC): Eric Dhuse
Assessment and Report Prepared by: Tammy Prusa
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC --
Structure Good Plumbing --
Roof Fair Electrical --
Vertical Envelope Poor Elevators --
Interiors Fair Fire --
SALT STORAGE BUILDING EMG PROJECT NO.: 122700.17R000-033.366
2
www.EMGcorp.com p 800.733.0660
The following bullet points highlight the most significant short term and modernization recommendations:
Full replacement of exterior metal siding
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have not been maintained since it was first occupied and is in fair to poor overall condition.
According to property management personnel, the property has had a limited capital improvement expenditure program over the past
three years.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
SALT STORAGE BUILDING EMG PROJECT NO.: 122700.17R000-033.366
3
www.EMGcorp.com p 800.733.0660
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 7.4% Fair
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 20.3% Poor
Current Replacement Value (CRV) 1,600 SF * $183.24 / SF = $293,184.00
Year 0 (Current Year) - Immediate Repairs (IR) $21,687.00
Years 1-10 – Replacement Reserves (RR) $59,722.00
Total Capital Needs $81,409.00
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Replace exterior metal siding
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
SALT STORAGE BUILDING EMG PROJECT NO.: 122700.17R000-033.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: Pre-Survey Questionnaire
Appendix D: ADA Checklist
SALT STORAGE BUILDING EMG PROJECT NO.: 122700.17R000-033.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
SALT STORAGE BUILDING
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-033.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: LEFT ELEVATION
#3: REAR ELEVATION
#4: RIGHT ELEVATION
#5: FOUNDATIONS, CONCRETE
SLAB-ON-GRADE
#6: ROOF, METAL
SALT STORAGE BUILDING
610 TOWER LANE
YORKVILLE, ILLINOIS 60560 EMG PROJECT NO: 122700.17R000-033.366
www.EMGcorp.com p 800.733.0660
#7: MISSING PIECES OF EXTERIOR
SIDING
#8: DETERIORATED AND RUSTED
SIDING
#9: EXTERIOR WALL, ALUMINUM
SIDING
#10: INTERIOR WALL FINISH,
PLYWOOD
SALT STORAGE BUILDING EMG PROJECT NO.: 122700.17R000-033.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Salt Storage Building
Project Number:
122700.17R000-033.366
Source:
Google Earth
On-Site Date:
May 22, 2017
SALT STORAGE BUILDING EMG PROJECT NO.: 122700.17R000-033.366
www.EMGcorp.com p 800.733.0660
Appendix C:
Pre-Survey Questionnaire
SALT STORAGE BUILDING EMG PROJECT NO.: 122700.17R000-033.366
www.EMGcorp.com p 800.733.0660
Appendix D:
ADA Checklist
Page 1 of 4
Date Completed: June 8, 2017
Property Name: Salt Storage Building
EMG Project Number: 122700.17R000-033.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X Included in separate report.
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Treatment Facility Well 8 and 9
3299 Lehman Crossing
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-036.366 June 29, 2017 May 24, 2017
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
FACILITY CONDITION ASSESSMENT
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO.: 122700.17R000-036.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO.: 122700.17R000-036.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 3299 Lehman Crossing, Yorkville, IL 60560
Year Constructed/Renovated: 2005
Current Occupants: City of Yorkville
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Water Treatment Facility
Site Area: 2.5 acres
Building Area: 3,200 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: 0 marked spaces in open lots
Building Construction: Masonry bearing walls and wood-framed roofs
Roof Construction: Gabled roofs with asphalt shingles
Exterior Finishes: Brick Veneer
Heating, Ventilation and Air Conditioning: Ductless split-systems, suspended electric unit heaters, and ceiling fans
Fire and Life/Safety: Fire sprinklers, hydrants, smoke detectors, alarms, strobes, extinguishers, pull stations,
alarm panel, and exit signs
Dates of Visit: May 24, 2017
On-Site Point of Contact (POC): Eric Dhuse
Assessment and Report Prepared by: Tammy Prusa
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC Fair
Structure Good Plumbing Fair
Roof Fair Electrical Fair
Vertical Envelope Good Elevators --
Interiors Fair Fire Good
The following bullet points highlight the most significant short term and modernization recommendations:
Installation of a complete fire suppression system.
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO.: 122700.17R000-036.366
2
www.EMGcorp.com p 800.733.0660
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in fair overall condition.
The property has had no major capital improvements. The property is less than 12 years old and has not required any major capital
improvements.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 4.4% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 43.3% Poor
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO.: 122700.17R000-036.366
3
www.EMGcorp.com p 800.733.0660
Key Finding Metric
Current Replacement Value (CRV) 3,200 SF * $183.24 / SF = $586,368.00
Year 0 (Current Year) - Immediate Repairs (IR) $25,596.00
Years 1-10 – Replacement Reserves (RR) $253,760.00
Total Capital Needs $279,356.00
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
Installation of a complete fire suppression system.
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO.: 122700.17R000-036.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: ADA Checklist
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO.: 122700.17R000-036.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO: 122700.17R000-036.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: LEFT ELEVATION
#3: REAR ELEVATION
#4: RIGHT ELEVATION
#5: PARKING LOTS, ASPHALT
PAVEMENT
#6: PEDESTRIAN PAVEMENT,
SIDEWALK, CONCRETE
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO: 122700.17R000-036.366
www.EMGcorp.com p 800.733.0660
#7: FENCES & GATES, CHAIN LINK
#8: ROOF, ASPHALT SHINGLE
#9: EXTERIOR WALL, CONCRETE
BLOCK (CMU)
#10: EXTERIOR WALL, BRICK VENEER
#11: OVERHEAD DOOR, ALUMINUM
ROLL-UP
#12: WINDOW, ALUMINUM DOUBLE-
GLAZED
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO: 122700.17R000-036.366
www.EMGcorp.com p 800.733.0660
#13: EXTERIOR DOOR, STEEL
#14: DUCTLESS SPLIT SYSTEM,
SINGLE ZONE
#15: DUCTLESS SPLIT SYSTEM,
SINGLE ZONE
#16: UNIT HEATER, ELECTRIC
#17: RESIDENTIAL FIXTURES,
CEILING FAN
#18: WATER FLOW METER
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO: 122700.17R000-036.366
www.EMGcorp.com p 800.733.0660
#19: EMERGENCY EYE WASH
#20: WATER STORAGE TANK
#21: LAVATORY, VITREOUS CHINA
#22: TOILET, FLUSH TANK (WATER
CLOSET)
#23: SERVICE SINK, FLOOR
#24: WATER FLOW METER
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO: 122700.17R000-036.366
www.EMGcorp.com p 800.733.0660
#25: WATER HEATER, ELECTRIC,
RESIDENTIAL
#26: EMERGENCY SHOWER STATION
#27: BOOSTER PUMP
#28: BACKFLOW PREVENTER
#29: HIGH PRESSURE SODIUM
LIGHTING FIXTURE
#30: TRANSFER SWITCH, AUTOMATIC
(ATS)
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO: 122700.17R000-036.366
www.EMGcorp.com p 800.733.0660
#31: BUILDING/MAIN SWITCHGEAR
#32: INCANDESCENT LIGHTING
FIXTURE, BASIC
#33: DISTRIBUTION PANEL
#34: SECONDARY TRANSFORMER,
DRY
#35: BUILDING AUTOMATION SYSTEM
(HVAC CONTROLS)
#36: GENERATOR, DIESEL
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO: 122700.17R000-036.366
www.EMGcorp.com p 800.733.0660
#37: MOTOR CONTROL CENTER W/
MAIN BREAKER
#38: LIGHTING SYSTEM, INTERIOR
#39: EXIT LIGHTING FIXTURE
#40: FIRE ALARM CONTROL PANEL,
ADDRESSABLE
#41: FIRE EXTINGUISHER
#42: INTERIOR DOOR, STEEL W/
SAFETY GLASS
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO: 122700.17R000-036.366
www.EMGcorp.com p 800.733.0660
#43: INTERIOR CEILING FINISH,
GYPSUM BOARD/PLASTER
#44: INTERIOR WALL FINISH,
CONCRETE/MASONRY
#45: INTERIOR FLOOR FINISH,
CONCRETE
#46: INTERIOR WINDOW
#47: INTERIOR DOOR, STEEL
#48: SINK, EPOXY RESIN,
LABORATORY
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO: 122700.17R000-036.366
www.EMGcorp.com p 800.733.0660
#49: KITCHEN CABINET, BASE AND
WALL SECTION, WOOD
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO.: 122700.17R000-036.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Treatment Facility Well 8 and 9
Project Number:
122700.17R000-036.366
Source:
Google Earth
On-Site Date:
May 24, 2017
TREATMENT FACILITY WELL 8 AND 9 EMG PROJECT NO.: 122700.17R000-036.366
www.EMGcorp.com p 800.733.0660
Appendix C:
ADA Checklist
Page 1 of 4
Date Completed: June 7, 2017
Property Name: Treatment Facility Well 8 and 9
EMG Project Number: 122700.17R000-036.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X No marked parking spaces.
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches? X
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Well 3 – Not Assessed
Alley near Hydraulic Street
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-037.366 June 28, 2017 May 25, 2017
FACILITY CONDITION ASSESSMENT
WELL 3 – NOT ASSESSED EMG PROJECT NO.: 122700.17R000-037.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
WELL 3 – NOT ASSESSED EMG PROJECT NO.: 122700.17R000-037.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: In alley, near Hydraulic Street, Yorkville, Kendall, Illinois 60560
Year Constructed/Renovated: 1950
Current Occupants: City of Yorkville Water Department
Management Point of Contact:
City of Yorkville/Facilities, Erin Willrett, Manager
630.553.8574 phone
ewillrett@Yorkville.il.us e-mail
Property Type: City Building , Pump Building
Site Area: 0.2 acres
Building Area: 600 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: 0 spaces in open lots, street parking only
Building Construction: Painted CMU
Roof Construction: Flat layered asphalt - tar
Exterior Finishes: Painted CMU
Heating, Ventilation and Air Conditioning: Ceiling mounted unit heaters
Fire and Life/Safety: Hydrants
Dates of Visit: May 26, 2017
On-Site Point of Contact (POC): Tony Houle
Assessment and Report Prepared by: George Wozniczka
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC Poor
Structure Fair Plumbing Poor
Roof Fair Electrical Fair
Vertical Envelope Fair Elevators --
Interiors Failed Fire --
The following bullet points highlight the most significant short term and modernization recommendations:
Soil sampling – post demolition
WELL 3 – NOT ASSESSED EMG PROJECT NO.: 122700.17R000-037.366
2
www.EMGcorp.com p 800.733.0660
Building demolition
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied in 1950 and is in fair overall condition. The POC did not request a
detailed assessment for this building.
According to property management personnel, the property has not had an active capital improvement expenditure program over the
past three years. The building is scheduled for demolition in the summer of 2017.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
WELL 3 – NOT ASSESSED EMG PROJECT NO.: 122700.17R000-037.366
3
www.EMGcorp.com p 800.733.0660
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 90.5% Poor
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) NA --
Current Replacement Value (CRV) 600 SF * $183.24 / SF = $18,323.71
Year 0 (Current Year) - Immediate Repairs (IR) $16,578
Years 1-10 – Replacement Reserves (RR) $0.00
Total Capital Needs $16,578
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
None. Building is to be demolished in the summer of 2017
Environmental assessment of site after demolition
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
WELL 3 – NOT ASSESSED EMG PROJECT NO.: 122700.17R000-037.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: Pre-Survey Questionnaire
Appendix D: ADA Checklist
WELL 3 – NOT ASSESSED EMG PROJECT NO.: 122700.17R000-037.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
WELL 3 – NOT ASSESSED EMG PROJECT NO.: 122700.17R000-037.366
www.EMGcorp.com p 800.733.0660
PHOTO
#1:
FRONT ELEVATION PHOTO
#2:
SOUTHERN ELEVATION
PHOTO
#3:
WESTERN ELEVATION PHOTO
#4:
REAR ELEVATION AND ROOF
PHOTO
#5:
LANDSCAPING PHOTO
#6:
FENCING
WELL 3 – NOT ASSESSED EMG PROJECT NO.: 122700.17R000-037.366
www.EMGcorp.com p 800.733.0660
PHOTO
#7:
MASONRY AND SIDEWALK PHOTO
#8:
EXTERIOR ENTRANCE DOOR
PHOTO
#9:
INTERIOR SPACE, PAINTED CMU PHOTO
#10:
PREVIOUS PUMP AREA INTERIOR
PHOTO
#11:
INTERIOR SPACE PHOTO
#12:
INTERIOR SPACE
WELL 3 – NOT ASSESSED EMG PROJECT NO.: 122700.17R000-037.366
www.EMGcorp.com p 800.733.0660
PHOTO
#13:
UNIT HEATER 1 PHOTO
#14:
UNIT HEATER 2
PHOTO
#15:
PLUMBING PHOTO
#16:
WINDOW
PHOTO
#17:
INTERIOR DOOR PHOTO
#18:
ELECTRICAL SERVICE -
TRANSFORMER
WELL 3 – NOT ASSESSED EMG PROJECT NO.: 122700.17R000-037.366
www.EMGcorp.com p 800.733.0660
PHOTO
#19:
ELECTRICAL SERVICE PHOTO
#20:
LIGHT FIXTURE
PHOTO
#21:
OCCUPANCY SENSOR PHOTO
#22:
ELECTRICAL PANEL
PHOTO
#23:
FLOOR FINISH PHOTO
#24:
WALL AND CEILING FINISH
WELL 3 – NOT ASSESSED EMG PROJECT NO.: 122700.17R000-037.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name
Well 3 – Not Assessed
Project Number:
122700.17R000-037.366
Source:
Google Map
On-Site Date:
May 25, 2017
WELL 3 – NOT ASSESSED EMG PROJECT NO.: 122700.17R000-037.366
www.EMGcorp.com p 800.733.0660
Appendix C:
Pre-Survey Questionnaire
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
This questionnaire must be completed by the property owner, the owner's designated representative, or someone
knowledgeable about the subject property. If the form is not completed, EMG’s Project Manager will require additional
time during the on-site visit with such a knowledgeable person in order to complete the questionnaire. During the site visit,
EMG's Field Observer may ask for details associated with selected questions. This questionnaire will be utilized as an
exhibit in EMG's final report.
Name of Institution: Well 3 Building – Not Assessed – To be demolished in 2017
Name of Building: Well 3 Building Building #: Pump Building 3
Name of person completing questionnaire: Tony Houle, G Wozniczka
Length of Association With the Property: 10 years, Phone Number: 630-885-3569
Site Information
Year of Construction? 1950
No. of Stories? 1
Total Site Area? 0.15 acre
Total Building Area? 600 Sq ft
Inspections Date of Last
Inspection List of Any Outstanding Repairs Required
1. Elevators N/A
2. HVAC Mechanical, Electric,
Plumbing? 2016
3. Life-Safety/Fire? N/A
4. Roofs? Annually
Key Questions Response
Major Capital Improvements in Last 3 yrs. None
Planned Capital Expenditure For Next Year? None
Age of the Roof? 1990
What bldg. Systems Are Responsibilities of
Tenants? (HVAC/Roof/Interior/Exterior/Paving) All are city owned
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
ZONING, BUILDING DESIGN & LIFE SAFETY ISSUES
1 Are there any unresolved building,
fire, or zoning code issues? x
2 Is there any pending litigation
concerning the property? x
3 Are there any other significant
issues/hazards with the property? x
4 Are there any unresolved
construction defects at the
property?
x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
ZONING, BUILDING DESIGN & LIFE SAFETY ISSUES
5 Has any part of the property ever
contained visible suspect mold
growth?
x
6 Is there a mold Operations and
Maintenance Plan? x
7 Are there any recalled fire sprinkler
heads (Star, GEM, Central, and
Omega)?
x
8 Have there been indoor air quality
or mold related complaints from
tenants?
x
GENERAL SITE
9 Are there any problems with
erosion, storm water drainage or
areas of paving that do not drain?
x
10 Are there any problems with the
landscape irrigation systems? x
BUILDING STRUCTURE
11 Are there any problems with
foundations or structures? x
12 Is there any water infiltration in
basements or crawl spaces? x
13 Has a termite/wood boring insect
inspection been performed within
the last year?
x
BUILDING ENVELOPE
14 Are there any wall, or window
leaks? x
15 Are there any roof leaks? x
16 Is the roofing covered by a
warranty or bond? x
17 Are there any poorly insulated
areas? x
18 Is Fire Retardant Treated (FRT)
plywood used? x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
BUILDING ENVELOPE
19 Is exterior insulation and finish
system (EIFS) or a synthetic
stucco finish used?
x
BUILDING HVAC AND ELECTRICAL
20 Are there any leaks or pressure
problems with natural gas service? x
21 Does any part of the electrical
system use aluminum wiring? x
22 Do Residential units have a less
than 60-Amp service? x
23 Do Commercial units have less
than 200-Amp service? x
24 Are there any problems with the
utilities, such as inadequate
capacities?
x
ADA
25 Has the management previously
completed an ADA review? x
26 Have any ADA improvements
been made to the property? x
27 Does a Barrier Removal Plan exist
for the property? x
28 Has the Barrier Removal Plan
been approved by an arms-length
third party?
x
29 Has building ownership or
management received any ADA
related complaints?
x
30 Does elevator equipment require
upgrades to meet ADA standards? x
PLUMBING
31 Is the property served by private
water well? x
32 Is the property served by a private
septic system or other waste
treatment systems?
x
33 Is polybutylene piping used? x
FCA (EMG-FacilityDude)
Pre-Survey Questionnaire
October 2016 Update
Mark the column corresponding to the appropriate response. Please provide additional details in the Comments column, or
backup documentation for any Yes responses. (NA indicates “Not Applicable”, Unk indicates “Unknown”)
QUESTION Y N Unk NA COMMENTS
34 Are there any plumbing leaks or
water pressure problems? x
Additional Issues or Concerns That EMG Should Know About?
1. The property is in poor condition
2.
3.
Items Provided to EMG Auditors
Yes No N/A Additional Comments?
Access to All Mechanical Spaces
Access to Roof/Attic Space
Access to Building As-Built Drawings Available
Site plan with bldg., roads, parking and other features
Contact Details for Mech, Elevator, Roof, Fire
Contractors:
List of Commercial Tenants in the property
Previous reports pertaining to the physical condition of
property.
ADA survey and status of improvements implemented.
Current / pending litigation related to property
condition.
Any brochures or marketing information.
________________________________ ___________
Signature of person Interviewed or completing form Date
WELL 3 – NOT ASSESSED EMG PROJECT NO.: 122700.17R000-037.366
www.EMGcorp.com p 800.733.0660
Appendix D:
ADA Checklist
Page 1 of 4
Date Completed: May 25, 2017
Property Name: Well 3 – Not assessed
EMG Project Number: 122700.17R000-037.366
Building History Yes No Unk Comments
1 Has an ADA survey previously been
completed for this property?
2 Have any ADA improvements been made
to the property?
3 Does a Transition Plan / Barrier Removal
Plan exist for the property?
4 Has building ownership or management
received any ADA related complaints that
have not been resolved?
5 Is any litigation pending related to ADA
issues?
Parking Yes No NA Comments
1 Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
No parking at the well, street parking only
2 Are there sufficient van-accessible parking
spaces available?
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
5 Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
6 If required does signage exist directing you
to accessible parking and an accessible
building entrance?
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less)
2
Are ramps that appear longer than 6 ft
complete with railings on both sides?
Page 2 of 4
Ramps (cont.) Yes No NA Comments
3
Does the width between railings appear at
least 36 inches?
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door?
2
If the main entrance is inaccessible, are
there alternate accessible entrances?
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
Door knob
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? Entrance at door is not ADA accessible
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? No restroom
3
Is there a path of travel that does not
require the use of stairs?
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives?
2
Are there visual and audible signals inside
cars indicating floor change?
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons?
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door?
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)?
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication?
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? No toilet
2
Are pull handles push/pull or lever type?
3
Are there audible and visual fire alarm
devices in the toilet rooms?
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)?
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? No toilet
6
In unisex toilet rooms, are there safety
alarms with pull cords?
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)?
8
Are grab bars provided in toilet stalls?
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)?
10
Are sink handles operable with one hand
without grasping, pinching or twisting?
11
Are exposed pipes under sink sufficiently
insulated against contact?
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
Page 4 of 4
Guest Rooms Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section.
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
*Based on visual observation only. The slope was not confirmed through measurements.
EMG Corporate Headquarters 10461 Mill Run Circle, Suite 1100, Owings Mills, MD 21117 www.EMGcorp.com p 800.733.0660
Prepared for:
United City of Yorkville
800 Game Farm Road
Yorkville, Illinois 60560
FACILITY CONDITION ASSESSMENT
Well 4
610 Tower Lane
Yorkville, Illinois 60560
PREPARED BY: EMG CONTACT:
EMG Andrew Hupp
10461 Mill Run Circle, Suite 1100 Senior Engineering Consultant
Owings Mills, Maryland 21117 800.733.0660 x6632
800.733.0660 arhupp@emgcorp.com
www.EMGcorp.com
EMG Project Number: Date of Report: On Site Date:
122700.17R000-038.366 June 26, 2017 May 22, 2017
FACILITY CONDITION ASSESSMENT
WELL 4 EMG PROJECT NO.: 122700.17R000-038.366
www.EMGcorp.com p 800.733.0660
TABLE OF CONTENTS
1 Executive Summary ............................................................................................................................. 1
1.1. Property Information and General Physical Condition ................................................................ 1
1.2. Facility Condition Index (FCI) ...................................................................................................... 2
2 Appendices ........................................................................................................................................... 4
WELL 4 EMG PROJECT NO.: 122700.17R000-038.366
1
www.EMGcorp.com p 800.733.0660
1 Executive Summary
1.1. Property Information and General Physical Condition
The property information is summarized in the table below. More detailed descriptions may be found in the various sections of the
report and in the Appendices.
Property Information
Address: 610 Tower Lane, Yorkville, Illinois 60560
Year Constructed/Renovated: 1996
Current Occupants: City of Yorkville
Management Point of Contact:
City of Yorkville, Mr. Peter Ratos
630.553.8574 phone
pratos@yorkville.il.us email
Property Type: Shed
Site Area: 0.1 acres
Building Area: 115 SF
Number of Buildings: 1
Number of Stories: 1
Parking Type and Number of Spaces: Parking lot was included in the Public Works Office and Garage Report.
Building Construction: Conventional wood frame structure on concrete slab.
Roof Construction: Gabled roofs with Metal Roof.
Exterior Finishes: Metal Siding
Heating, Ventilation and Air Conditioning: N/A
Fire and Life/Safety: N/A
Dates of Visit: May 22, 2017
On-Site Point of Contact (POC): Eric Dhuse
Assessment and Report Prepared by: Tammy Prusa
Reviewed by:
Paul Prusa P.E., LEED AP
Technical Report Reviewer
For
Andrew Hupp
arhupp@emgcorp.com
800.733.0660 x6632
Systemic Condition Summary
Site Fair HVAC --
Structure Good Plumbing --
Roof Fair Electrical --
Vertical Envelope Fair Elevators --
Interiors Fair Fire --
The following bullet points highlight the most significant short term and modernization recommendations:
There were no short term or modernization recommendations.
WELL 4 EMG PROJECT NO.: 122700.17R000-038.366
2
www.EMGcorp.com p 800.733.0660
Generally, the property appears to have been constructed within industry standards in force at the time of construction. The property
appears to have been well maintained since it was first occupied and is in fair overall condition. The building interiors were inaccessible
due to lack of keys.
The property has had no major capital improvements. The property is less than 25 years old and has not required any major capital
improvements.
1.2. Facility Condition Index (FCI)
One of the major goals of the FCA is to calculate the FCI, which gives an indication of a building’s overall condition. Two FCI ratios are
calculated and presented, the Current Year and Ten-Year. The Current Year FCI is the ratio of Immediate Repair Costs to the building’s
Current Replacement Value. Similarly, the Ten-Year FCI is the ratio of anticipated Capital Reserve Needs over the next ten years to
the Current Replacement Value.
FCI Condition
Rating Definition Percentage Value
Good In new or well-maintained condition, with no visual evidence of wear,
soiling or other deficiencies. 0% to 5%
Fair Subjected to wear and soiling but is still in a serviceable and functioning
condition. > than 5% to 10%
Poor Subjected to hard or long-term wear. Nearing the end of its useful or
serviceable life. > than 10% to 60%
Very Poor Has reached the end of its useful or serviceable life. Renewal is now
necessary. > than 60%
The graphs above and tables below represent summary-level findings for the FCA. The deficiencies identified in this assessment can
be combined with potential new construction requirements to develop an overall strategy that can serve as the basis for a portfolio-wide
capital improvement funding strategy. Key findings from the assessment include:
Key Finding Metric
Current Year Facility Condition Index (FCI) FCI = (IR)/(CRV) 0.0% Good
10-Year Facility Condition Index (FCI) FCI = (RR)/(CRV) 9.1% Fair
Current Replacement Value (CRV) 115 SF * $183.24 / SF = $21,072.60
WELL 4 EMG PROJECT NO.: 122700.17R000-038.366
3
www.EMGcorp.com p 800.733.0660
Key Finding Metric
Year 0 (Current Year) - Immediate Repairs (IR) $0.00
Years 1-10 – Replacement Reserves (RR) $1,913.00
Total Capital Needs $1,193.00
The major issues contributing to the Immediate Repair Costs and the Current Year FCI ratio are summarized below:
There were no short term or modernization recommendations
Further detail on the specific costs that make up the Immediate Repair Costs can be found in the cost tables at the beginning of this
report.
WELL 4 EMG PROJECT NO.: 122700.17R000-038.366
4
www.EMGcorp.com p 800.733.0660
2 Appendices
Appendix A: Photographic Record
Appendix B: Site Plan
Appendix C: ADA Checklist
WELL 4 EMG PROJECT NO.: 122700.17R000-038.366
www.EMGcorp.com p 800.733.0660
Appendix A:
Photographic Record
WELL 4 EMG PROJECT NO: 122700.17R000-038.366
www.EMGcorp.com p 800.733.0660
#1: FRONT ELEVATION
#2: LEFT ELEVATION
#3: REAR ELEVATION
#4: RIGHT ELEVATION
#5: ROOF, METAL
#6: EXTERIOR WALL, ALUMINUM
SIDING
WELL 4 EMG PROJECT NO: 122700.17R000-038.366
www.EMGcorp.com p 800.733.0660
#7: EXTERIOR DOOR, WOOD
SOLID-CORE
#8: WINDOW, ALUMINUM DOUBLE-
GLAZED
WELL 4 EMG PROJECT NO.: 122700.17R000-038.366
www.EMGcorp.com p 800.733.0660
Appendix B:
Site Plan
Site Plan
Project Name:
Well 4
Project Number:
122700.17R000-038.366
Source:
Google Earth
On-Site Date:
May 22, 2017
WELL 4 EMG PROJECT NO.: 122700.17R000-038.366
www.EMGcorp.com p 800.733.0660
Appendix C:
ADA Checklist
Page 1 of 4
Date Completed: June 6, 2017
Property Name: Well 4
EMG Project Number: 122700.17R000-038.366
Building History Yes No Unk Comments
1
Has an ADA survey previously been
completed for this property? X
2
Have any ADA improvements been made
to the property? X
3
Does a Transition Plan / Barrier Removal
Plan exist for the property? X
4
Has building ownership or management
received any ADA related complaints that
have not been resolved?
X
5
Is any litigation pending related to ADA
issues? X
Parking Yes No NA Comments
1
Are there sufficient accessible parking
spaces with respect to the total number of
reported spaces?
X
2
Are there sufficient van-accessible parking
spaces available? X
3
Are accessible spaces marked with the
International Symbol of Accessibility? Are
there signs reading “Van Accessible” at van
spaces?
X
4
Is there at least one accessible route
provided within the boundary of the site
from public transportation stops, accessible
parking spaces, passenger loading zones,
if provided, and public streets and
sidewalks?
X
5
Do curbs on the accessible route have
depressed, ramped curb cuts at drives,
paths, and drop-offs?
X
6
If required does signage exist directing you
to accessible parking and an accessible
building entrance?
X
Ramps Yes No NA Comments
1*
Do all ramps along accessible path of
travel appear to meet slope requirements?
( 1:12 or less) X
2
Are ramps that appear longer than 6 ft
complete with railings on both sides? X
3
Does the width between railings appear at
least 36 inches? X
Page 2 of 4
Ramps (cont.) Yes No NA Comments
4
Is there a level landing for approximately
every 30 ft horizontal length of ramp, at the
top and at the bottom of ramps and
switchbacks?
X
Entrances/Exits Yes No NA Comments
1
Do all required accessible entrance
doorways appear at least 32 inches wide
and not a revolving door? X
2
If the main entrance is inaccessible, are
there alternate accessible entrances? X
3
Is the door hardware easy to operate
(lever/push type hardware, no twisting
required and not higher than approximately
48 inches above the floor)?
X
Paths of Travel Yes No NA Comments
1
Are all paths of travel free of obstruction
and wide enough for a wheelchair (appear
at least 36 inches wide)? X
2
Are wheelchair-accessible facilities (toilet
rooms, exits, etc.) identified with signage? X
3
Is there a path of travel that does not
require the use of stairs? X
Elevators Yes No NA Comments
1
Do the call buttons have visual and audible
signals to indicate when a call is registered
and answered when car arrives? X
2
Are there visual and audible signals inside
cars indicating floor change? X
3
Are there standard raised and Braille
marking on both jambs of each hoist way
entrance as well as all cab/call buttons? X
4
Do elevator doors have a reopening device
that will stop and reopen a car door if an
object or a person obstructs the door? X
5
Are elevator controls low enough to be
reached from a wheelchair (appears to be
between 15 and 48 inches)? X
6
If a two-way emergency communication
system is provided within the elevator cab,
is it usable without voice communication? X
Page 3 of 4
Toilet Rooms Yes No NA Comments
1
Are common area public restrooms located
on an accessible route? X
2
Are pull handles push/pull or lever type?
X
3
Are there audible and visual fire alarm
devices in the toilet rooms? X
4
Are toilet room access doors wheelchair-
accessible (appear to be at least 32 inches
wide)? X
5
Are public restrooms large enough to
accommodate a wheelchair turnaround
(appear to have 60” turning diameter)? X
6
In unisex toilet rooms, are there safety
alarms with pull cords? X
7
Are toilet stall doors wheelchair accessible
(appear to be at least 32” wide)? X
8
Are grab bars provided in toilet stalls?
X
9
Are sinks provided with clearance for a
wheelchair to roll under (appear to have
29” clearance)? X
10
Are sink handles operable with one hand
without grasping, pinching or twisting? X
11
Are exposed pipes under sink sufficiently
insulated against contact? X
Guest Rooms Yes No NA Comments
1
How many total accessible sleeping rooms
does the property management report to
have? Provide specific number in
comment field.
Are there sufficient reported accessible
sleeping rooms with respect to the total
number of reported guestrooms? See
attached hot sheet.
X
Page 4 of 4
Guest Rooms (cont.) Yes No NA Comments
2
How many of the accessible sleeping
rooms per property management have roll-
in showers? Provide specific number in
comment field.
Are there sufficient reported accessible
rooms with roll-in showers with respect to
the total number of reported accessible
guestrooms? See attached hot sheet.
X
3
How many assistive listening kits and/or
rooms with communication features are
available per property management?
Provide specific number in comment
field.
Are there sufficient reported assistive
listening devices with respect to the total
number of rooms? See attached hot sheet.
X
Pools Yes No NA Comments
1 Are public access pools provided? If the
answer is no, please disregard this section. X
2
How many accessible access points are
provided to each pool/spa? Provide
number in comment field.
Is at least one fixed lift or sloped entry to
the pool provided?
X
Play Area Yes No NA Comments
1
Has the play area been reviewed for
accessibility? All public playgrounds are
subject to ADAAG standards.
X
Exercise Equipment Yes No NA Comments
1
Does there appear to be adequate clear
floor space around the
machines/equipment (30” by 48”
minimum)?
X
*Based on visual observation only. The slope was not confirmed through measurements.
Have a question or comment about this agenda item?
Call us Monday-Friday, 8:00am to 4:30pm at 630-553-4350, email us at agendas@yorkville.il.us, post at www.facebook.com/CityofYorkville,
tweet us at @CityofYorkville, and/or contact any of your elected officials at http://www.yorkville.il.us/320/City-Council
Agenda Item Summary Memo
Title:
Meeting and Date:
Synopsis:
Council Action Previously Taken:
Date of Action: Action Taken:
Item Number:
Type of Vote Required:
Council Action Requested:
Submitted by:
Agenda Item Notes:
Reviewed By:
Legal
Finance
Engineer
City Administrator
Human Resources
Community Development
Police
Public Works
Parks and Recreation
Agenda Item Number
Old Business #1
Tracking Number
PW 2017-49
Selection of Committee Liaisons
Public Works Committee – September 19, 2017
Selection of liaison to the Yorkville-Bristol Sanitary District.
Bart Olson Administration
Name Department
Summary
Review of YBSD Committee Liaison concerns that was brought up at the June 20, 2017 Public Works
Committee meeting.
Background
I talked to YBSD’s Executive Director, Cyrus McMain on June 22, 2017. He let me know he is in the
process of improving communication and transparency at the district. The new process for packets will
be implemented for the YBSD Board meeting in August. He stated that that they post the agendas at the
gate at their location the Friday prior to the meeting. He is hoping to update the website and post the
agendas online by the end of the calendar year.
Recommendation
Informational item only.
Memorandum
To: Public Works Committee
From: Erin Willrett, Assistant City Administrator
CC:
Date: August 15, 2017
Subject: YBSD Committee Liaison Follow-Up